Det-Tronics Duct-Mounting Kits for PointWatch Eclipse Model PIRECL
The Direct Duct Mount Assembly (p/n 007525-XXX series) (Spec Sheet: 90-1151) is FM approved for use with PointWatch Eclipse model PIRECL to be installed directly within air handling ductwork. The assembly is mounted on the duct wall, with the PIRECL sensing chamber exposed directly to duct airflow, ensuring fast response to Methane. A built-in calibration gas nozzle with an external, self-sealing fitting enables testing and calibration without removal of the detector from the duct. Not recommended for applications where duct air temperatures can exceed 167 °F (75 °C). Price includes all necessary hardware for proper operation, but does not include the PointWatch Eclipse PIRECL gas detector. A factory pre-assembled Direct Duct Mount Kit is available (p/n 007529-XXX series) that provides a PIRECL detector prefit into the Direct Duct Mount kit assembly. Pricing for the 007529-XXX assembly includes the PIRECL gas detector. The Direct Duct Mount Assembly complies to the ANSI/ISA-12.13.01-2000 performance standards. Direct Duct Mount Kits (PIRECL not included) Part Number Mount Material Ship Weight 007525-003 Vertical 316 SS 3.5 lb (1.6 kg) 007525-004 Vertical Aluminum 1 lb (0.46 kg) 007525-005 Horizontal 316 SS 3.5 lb (1.6 kg) 007525-006 Horizontal Aluminum 1 lb (0.46 kg) *Use PIRECL with standard baffle. Direct Duct Mount Assemblies Part Number Mount PIRECL Model PIRECL Output Hart Port Material 014101-410 Vertical PIRECLA11D3T1 4-20 mA X 316 SS 014101-440 Vertical PIRECLB11D3T1 4-20 mA X 316 SS 014101-416 Vertical PIRECLA14D3T1 EQP X 316 SS 014101-417 Vertical PIRECLB14D3T1 EQP X 316 SS 007529-903 Vertical PIRECLA4A3R1 EQP X 316 SS 007529-908 Horizontal PIRECLA4A3R1 EQP X 316 SS 007529-909 Vertical PIRECLB1A3R1 4-20mA X 316 SS Ship Weight 15 lb (6.8 kg) -

Det-Tronics Eagle Quantum Premier Controller EQ30XX
Eagle Quantum Premier Controller EQ30XX (Spec Sheet: 90-1148) The Eagle Quantum Premier Controller is a microprocessor-based module that performs all the communication and control functions for the system. The controller can be configured in a simplex or redundant mode of operation. It includes all the required operator interface controls for a fire alarm and releasing system. Fire detection and alarm Fire suppression control Gas detection and alarm Available in certified enclosures Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to FM 6310/6320 Performance certified to ATEX/IEC 60079-29-1 Simplex or redundant operation Models with SIL 2 certification Programmable logic Optional Dual Ethernet Ports (Modbus TCP/IP) Multiple serial ports (three RS-232 and two RS-485) Transformer isolation of network ports Utilizes Modbus RTU, Modbus TCP/IP, or Allen Bradley protocols ControlNet Interface (Optional DRL Device level ring EtherNet DLR) Eight Programmable Relay Outputs Dedicated Fault Output Eight Digital Inputs Four-line, 20-character alphanumeric display LED status indicators Fault-tolerant communication loop Extensive built-in diagnostics Real-time clock Compact design US Coast Guard type approval. Lloyd’s Register Type Approval. EQ30XX Model Matrix MODEL DESCRIPTION EQ3001 Eagle Quantum Premier Controller - 246 Nodes EQ3016 Eagle Quantum Premier Controller - 16 Nodes TYPE MOUNTING OPTION D Din Rail P Panel TYPE COM BOARD 1 N None C ControlNet D EtherNet DLR TYPE COM BOARD 2 N None D Ethernet IP with DLR E Ethernet IP S Serial Port Expansion TYPE APPROVALS* R VNIIPO/VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/IECEx *Type Approvals can use one or more letters to designate the approvals of the product. EQ3001 Controller - SIL 2 Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port SIL/FM/CSA/ ATEX/IECEx EQ3001PNNT 007609-072 Panel X EQ3001DNNT 007609-073 DIN X EQ3001PCNT 007609-075 Panel X X EQ3001DCNT 007609-076 DIN X X EQ3001PNET 007609-086 Panel X X X EQ3001DNET 007609-087 DIN X X X EQ3001PCET 007609-088 Panel X X X X EQ3001DCET 007609-089 DIN X X X X EQ3001PNST 007609-077 Panel X X EQ3001DNST 007609-078 DIN X X EQ3001PCST 007609-079 Panel X X X EQ3001DCST 007609-080 DIN X X X EQ3001DDET 007609-189 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) EQ3016 Controller - SIL 2 Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port SIL/FM/CSA/ ATEX/IECEx EQ3016PNNT 007609-472 Panel EQ3016DNNT 007609-473 DIN EQ3016PCNT 007609-475 Panel X EQ3016DCNT 007609-476 DIN X X EQ3016PNET 007609-486 Panel X X X EQ3016DNET 007609-487 DIN X X X EQ3016PCET 007609-488 Panel X X X X EQ3016DCET 007609-489 DIN X X X X EQ3016PNST 007609-477 Panel X X EQ3016DNST 007609-478 DIN X X EQ3016PCST 007609-479 Panel X X X EQ3016DCST 007609-480 DIN X X X EQ3016DDET 007609-689 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) EQ3001 Controller Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port FM/CSA/ ATEX/IECEx EQ3001PNNW 007609-062 Panel X EQ3001DNNW 007609-063 DIN X EQ3001PCNW 007609-065 Panel X X EQ3001DCNW 007609-066 DIN X X EQ3001PNEW 007609-082 Panel X X X EQ3001DNEW 007609-083 DIN X X X EQ3001PCEW 007609-084 Panel X X X X EQ3001DCEW 007609-085 DIN X X X X EQ3001PNSW 007609-067 Panel X X EQ3001DNSW 007609-068 DIN X X EQ3001PCSW 007609-069 Panel X X X EQ3001DCSW 007609-070 DIN X X X EQ3001PCSW-C* 007609-269 Panel X X X EQ3001DDEW 007609-185 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) *US Coast Guard type approval under 46 CFR 161.002. For use with USCG approved system only. EQ3016 Controller Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port FM/CSA/ ATEX/IECEx EQ3016PNNW 007609-462 Panel X EQ3016DNNW 007609-463 DIN X EQ3016PCNW 007609-465 Panel X X EQ3016DCNW 007609-466 DIN X X EQ3016PNEW 007609-482 Panel X X X EQ3016DNEW 007609-483 DIN X X X EQ3016PCEW 007609-484 Panel X X X X EQ3016DCEW 007609-485 DIN X X X X EQ3016PNSW 007609-467 Panel X X EQ3016DNSW 007609-468 DIN X X EQ3016PCSW 007609-469 Panel X X X EQ3016DCSW 007609-470 DIN X X X EQ3016PNNW-C* 007609-282 Panel X EQ3016DDEW 007609-685 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) *US Coast Guard type approval under 46 CFR 161.002. For use with USCG approved system only. Redundancy Parts Part Number* Description Ship Weight 008981-001 Controller to Controller High Speed Serial Cable (4 ft) 1.0 lb (0.45 kg) 008982-001 EQ3LTM LON Termination Module (2 required per LON) 1.0 lb (0.45 kg) *Parts can only be used with EQP Controllers with serial port expansion option. Controller Communication Cables Part Number Description Length Ship Weight 15 ft. (4.57 m) 30 ft. (9.14m) 50 ft. (15.24m) 007633-001 Controller RS-232 Cable (DB9 Female PC Connection) X 1.0 lb (0.45 kg) 007633-002 Controller RS-232 Cable (DB9 Female PC Connection) X 1.0 lb (0.45 kg) 007633-003 Controller RS-232 Cable (DB9 Female PC Connection) X 1.6 lb (0.7 kg) Typical Order for a Redundant System Qty Part Number Description 2 007609-078 EQ3001DNST Controller 1 008981-001 Controller to Controller redundancy High Speed Serial Cable (4 ft) 2 008982-001 EQ3LTM LON Termination Module (2 required per LON) Interface Hardware RS 485 and Hart Part Number Description Ship Weight 014008-001 EQ2230RSP Surge Protector RS485 1.0 lb (.45 kg) 008056-001 HIM, HART Interface Module, EQP 1.0 lb (.45 kg) Which other Eagle Quantum Premier Controller EQ30XX part numbers can PE Energy supply?The 8 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description007609-184EQ3001PDEW EQP CONTROLLER007609-262EQ3001PNNW-C EQP CONTROLLER007609-277EQ3001PNST-C EQP CTRL,SIL007609-783EQ3016DNEK EQP CONTROLLER007609-784EQ3001DNEK EQP CONTROLLER007609-909EQ3001DDER EQP CONTROLLER007609-950EQ3016DCSSR,EQP CONTROLLER,SIL007609-963EQ3001DNNR, EQP CONTROLLER -

Det-Tronics 007168-014 PIRECLA4A2W1 GAS Detector – PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector
PIRECLA4A2W1 GAS Detector. Det-Tronics part number 007168-014, model code PIRECLA4A2W1, is part of the Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector product line. Part number 007168-014 is also written 007168014. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 007168-912 PIRECLA4A1R1 GAS Detector – PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector
PIRECLA4A1R1 GAS Detector. Det-Tronics part number 007168-912, model code PIRECLA4A1R1, is part of the Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector product line. Part number 007168-912 is also written 007168912. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 007819-002 W6300B1003, Inspector Connector
W6300B1003, Inspector Connector. Det-Tronics part number 007819-002, model code W6300B1003, is part of the Det-Tronics flame and gas detection range. Part number 007819-002 is also written 007819002. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 009640-001 GTS Sensor MOD., Filter – GTS Toxic Gas Sensor Module (GT3000 Series)
GTS Sensor MOD., Filter. Det-Tronics part number 009640-001 is part of the Det-Tronics GTS Toxic Gas Sensor Module (GT3000 Series) product line. Part number 009640-001 is also written 009640001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics GTS Toxic Gas Sensor Module (GT3000 Series) on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 010254-081 UD10A5M25B2C Display, RLY/4-20 – FlexVu UD10 Universal Display
UD10A5M25B2C Display, RLY/4-20. Det-Tronics part number 010254-081, model code UD10A5M25B2C, is part of the Det-Tronics FlexVu UD10 Universal Display product line. Part number 010254-081 is also written 010254081. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexVu UD10 Universal Display on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 010274-903 GT3000 CAL KIT, H2S 50 PPM, Russ – GT3000 Certified Calibration Kits
GT3000 CAL KIT, H2S 50 PPM, Russ. Det-Tronics part number 010274-903, model code GT3000, is part of the Det-Tronics GT3000 Certified Calibration Kits product line. Part number 010274-903 is also written 010274903. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics GT3000 Certified Calibration Kits on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 011784-001 LS2000 Mounting Adapter 6″ – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000 Mounting Adapter 6". Det-Tronics part number 011784-001, model code LS2000, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 011784-001 is also written 011784001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 012731-803 LS2000SM18SMSK1S Line OF Sight – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000SM18SMSK1S Line OF Sight. Det-Tronics part number 012731-803, model code LS2000SM18SMSK1S, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 012731-803 is also written 012731803. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 014023-011 UD30A3N12SA2
UD30A3N12SA2. Det-Tronics part number 014023-011, model code UD30A3N12SA2, is part of the Det-Tronics flame and gas detection range. Part number 014023-011 is also written 014023011. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 014191-002 UD30A3N12SE2C
UD30A3N12SE2C. Det-Tronics part number 014191-002, model code UD30A3N12SE2C, is part of the Det-Tronics flame and gas detection range. Part number 014191-002 is also written 014191002. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 014255-001 LS2000 Laser Aligner Assembly – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000 Laser Aligner Assembly. Det-Tronics part number 014255-001, model code LS2000, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 014255-001 is also written 014255001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 014256-001 LS2000 Laser Aligner Target – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000 Laser Aligner Target. Det-Tronics part number 014256-001, model code LS2000, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 014256-001 is also written 014256001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 014394-001 CTX10A3N2T
CTX10A3N2T. Det-Tronics part number 014394-001, model code CTX10A3N2T, is part of the Det-Tronics flame and gas detection range. Part number 014394-001 is also written 014394001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 014394-002 CTX10A3F2T
CTX10A3F2T. Det-Tronics part number 014394-002, model code CTX10A3F2T, is part of the Det-Tronics flame and gas detection range. Part number 014394-002 is also written 014394002. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 103363-001 Wrench, HEX, Metric 14, Long ARM
Wrench, HEX, Metric 14, Long ARM. Det-Tronics part number 103363-001 is part of the Det-Tronics flame and gas detection range. Part number 103363-001 is also written 103363001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics C7064E Sensor/Transmitter
C7064E Sensor/Transmitter (Spec Sheet: 90-1079) housing. Two-wire, stainless steel or aluminum toxic gas detector with 3/4” NPT or 20 mm threads. Purchase EC cell separately for monitoring H2S toxic gases. 4-20 mA output is proportional to EC cell measurement range Electrochemical cell sold separately For use with: - FlexVu UD10 Universal Display - U9500 Infiniti Transmitter - STB Sensor Termination Box - DCU Digital Communication Unit - R8471X Toxic Controller Optional measurement ranges available for H2S versions Hydrophobic filter provided on C7064E housings –40°C to 75°C hazardous location temperature rating C7064E H2S Electrochemical Sensor Housings (sensor sold separately) Model Part Number Toxic Gas Enclosure Threads Enclosure Material Measurement Range Approvals Other C7064E4012 004539-009 Hydrogen Sulfide 3/4 NPT SS All FM/CSA Groups C, D C7064E5012 004539-102 Hydrogen Sulfide M20 SS All FM/CSA Groups C, D C7064E6031 004539-103 Hydrogen Sulfide M20 SS All CSA Groups C, D C7064E5014 004539-105 Hydrogen Sulfide 3/4 NPT SS All FM/CSA Groups B, C, D Note: All C7064E housings above require an electrochemical sensor cell (not included) for proper operation. Shipping weight of all C7064E gas detector housings is 2.5 lbs (1.28 kg) -

Det-Tronics CGS Accessories: Rain Shields, Splash Guards, Dust Covers, Remote Calibration Cups
Rain Shields (Spec Sheet: 90-1046) protect combustible sensors from rain and snow. Splash Guards (Spec Sheet: 90-1046) protect combustible sensors from ingress due to rain or splashing water. Dust Covers (Spec Sheet: 90-1046) are recommended to protect sensors in windy, dusty, and oily environments. Porex and stainless steel filters available. Remote Calibration cups provide the means to apply calibration to a CGS gas sensor from a remote location. Tubing not included. Options include barbed fitting or ¼” compression fitting. NOTE: Only one accessory recommended to be fitted per catalytic sensor. Rain Shields Part Number Material Ship Weight 226349-001 AL 6 oz (0.17 kg) Splash Guard Part Number Material Ship Weight 006491-001 AL 2 lb (0.95 kg) Dust Covers Part Number Material Ship Weight 225312-001 SS 2 oz (0.06 kg) 226190-001 Porex* 2 oz (0.06 kg) *Porex not recommended for outdoors or temperatures above 75°C Remote Calibration Cups Part Number Use Filter Material Tube Fitting Type Ship Weight 225777-001 Indoor Porex* Barbed 0.5 lb (0.14 kg) 004996-001 Indoor Porex* Compression 0.5 lb (0.14 kg) 006618-001 Outdoor SS Screen Barbed 0.5 lb (0.14 kg) 006618-002 Outdoor SS Screen Compression 0.5 lb (0.14 kg) *Porex not recommended for outdoors or temperatures above 75°C. -

Det-Tronics CGS Combustible Gas Certified Calibration Kits
Combustible Gas Certified Calibration Kits (Spec Sheet: 90-1059) for combustible gas sensors. Kits include sturdy plastic carrying case containing: Two 3.6 ft3 (103 liters) cylinders of Class 2.2 non-flammable, non-toxic compressed gas Regulator/shutoff valve with gauge, 3-foot tubing and stainless steel CGS calibration cup Regulator provides fixed flow rate of 1 liter per minute designed for CGS sensors 3-foot tube Sturdy plastic carrying case Calibration Kits for CGS Catalytic Sensor Part Number Gas LFL % Vol Standard Balance Ship Weight 225130-002 Ethane 50% 1.5 ISO Air 11.5 lb (5.23 kg) 225130-902* Ethane 50% 1.5 ISO Air 11.5 lb (5.23 kg) 225130-003 Ethylene 50% 1.35 ISO Air 11.5 lb (5.23 kg) 225130-005 Hydrogen 50% 2.0 ISO Air 11.5 lb (5.23 kg) 225130-905* Hydrogen 50% 2.0 ISO Air 11.5 lb (5.23 kg) 225130-006 Methane 20% 1.0 ISO Air 11.5 lb (5.23 kg) 225130-007 Methane 25% 1.25 ISO Air 11.5 lb (5.23 kg) 225130-008 Methane 35% 1.75 ISO Air 11.5 lb (5.23 kg) 225130-014 Methane 50% 2.2 IEC Air 11.5 lb (5.23 kg) 225130-914* Methane 50% 2.2 IEC Air 11.5 lb (5.23 kg) 225130-001 Methane 50% 2.5 ISO Air 11.5 lb (5.23 kg) 225130-901* Methane 50% 2.5 ISO Air 11.5 lb (5.23 kg) 225130-015 Propane 50% 0.85 IEC Air 11.5 lb (5.23 kg) 225130-915* Propane 50% 0.85 IEC Air 11.5 lb (5.23 kg) 225130-004 Propane 50% 1.1 ISO Air 11.5 lb (5.23 kg) 225130-009 Empty kit–no cal gas 10 lb (4.6 kg) *These items are certified for Russian projects. NOTE: Average lead time is 2-3 weeks Replacement Gas Cylinders for Combustible Gas Calibration Kits Part Number Gas %LFL % Vol Standard Balance Ship Weight 226166-006 Zero Air N/A 20.9 N/A Nitrogen 1.5 lb (0.7 kg) 226166-002 Ethane 50% 1.5 ISO Air 1.5 lb (0.7 kg) 226166-902* Ethane 50% 1.5 ISO Air 1.5 lb (0.7 kg) 226166-003 Ethylene 50% 1.35 ISO Air 1.5 lb (0.7 kg) 226166-005 Hydrogen 50% 2.0 ISO Air 1.5 lb (0.7 kg) 226166-905* Hydrogen 50% 2.0 ISO Air 1.5 lb (0.7 kg) 226166-007 Methane 20% 1.0 ISO Air 1.5 lb (0.7 kg) 226166-008 Methane 25% 1.25 ISO Air 1.5 lb (0.7 kg) 226166-009 Methane 35% 1.75 ISO Air 1.5 lb (0.7 kg) 226166-014 Methane 50% 2.2 IEC Air 1.5 lb (0.7 kg) 226166-914* Methane 50% 2.2 IEC Air 1.5 lb (0.7 kg) 226166-001 Methane 50% 2.5 ISO Air 1.5 lb (0.7 kg) 226166-901* Methane 50% 2.5 ISO Air 1.5 lb (0.7 kg) 226166-015 Propane 50% 0.85 IEC Air 1.5 lb (0.7 kg) 226166-915* Propane 50% 0.85 IEC Air 1.5 lb (0.7 kg) 226166-004 Propane 50% 1.1 ISO Air 1.5 lb (0.7 kg) 226166-010 Propylene 50% 1.2 ISO Air 1.5 lb (0.7 kg) *These items are certified for Russian projects. Replacement Kit Replacement Parts Part Number Description Ship Weight 004976-001 Standard calibration cup, SS 8 oz (0.23 kg) 101678-007 Tubing, 3 ft. 8 oz (0.23 kg) 101678-013 Tubing, 100 ft. spool 8 oz (0.23 kg) 162552-001 1 LPM Regulator for CGS sensors 8 oz (0.23 kg) 162553-001 Carrying Case 8 oz (0.23 kg) -

Det-Tronics CGS Combustible Gas Sensor
CGS Combustible Gas Sensor (Spec Sheet: 90-1041). Stainless steel catalytic sensor that provides an accurate measurement of combustible gas concentration in the % LFL range. Requires FlexVu UD10, Model 505, U9500A or DCUEX transmitter. Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to FM 6310/6320, CSA 22.2 #154, and ATEX EN60079-29-1 Performance certified to IEC60079-29-1 when connected to the FlexVu UD10, UD10-DCU Detects hydrogen and hydrocarbon gases Constant current or constant voltage options available Poison resistant construction 3/4” NPT or 20 mm thread option Wire lead options of 6” or 30” Sensor Separation Termination Box (STB) option available Variety of special accessories available FlexVu UD10 universal display provides full digital readout, calibration and user interface Performance approved from –40°C to 75°C for life safety applications Hazardous Location approved from –55°C to 125°C for process control applications SIL2 certified when used with FlexVu UD10 Universal Display Combustible Gas Sensor for Models 505, 500, and K-Series Transmitters Model Part Number Replaces old catalytic sensor p/n Threads Lead Length FM/CSA/ATEX/IECEx Russia CGSS1A6V2R1X 006824-002 225006-002, 225957-001, 226530-001, 226531-001, 226931-001, 226931-002, 226999-002, 226999-004,223106-002 3/4 NPT 6 in X CGSS1A3V2R1X 006824-006 225006-005, 226530-004, 226531-002, 226931-003, 226931-004 3/4 NPT 30 in X CGSS1C3V2R1X 006824-008 M20 30 in X CGSS1C6V2R1X 006824-004 226999-010, 226999-013, 226999-018, 226999-019 M20 6 in X CGSS1C6V2R1R 006824-904 M20 6 in X Shipping Weight = 1 lb. (0.45 kg) NOTES: CGS sensors always require a transmitter (sold separately). Constant voltage Combustible Gas Sensor for UD10, DCUEX, U9500A, U8700, 400, 405, 810, 820, and 880 Transmitters Model Part Number Replaces old catalytic sensor p/n Threads Lead Length FM/CSA/ATEX/IECEx Russia Brazil CGSS1A6C2R1X 006824-001 225006-004, 225957-002, 226530-003, 226531-003, 226931-005, 226931-006, 226999-011, 226999-012 3/4 NPT 6 in X CGSS1A6C2R1B 006824-101 225006-003, 226530-005, 226531-004, 226931-007, 226931-008 3/4 NPT 6 in X CGSS1A3C2R1X 006824-005 3/4 NPT 30 in X CGSS1C3C2R1X 006824-007 225006-003, 226530-005, 226531-004, 226931-007, 226931-008 M20 30 in X CGSS1C6C2R1X 006824-003 226999-008, 226999-020, 226999-014, 226999-021 M20 6 in X CGSS1C6C2R1R 006824-903 M20 6 in X Shipping Weight = 1 lb. (0.45 kg) NOTES: CGS sensors always require a transmitter (sold separately). Constant current Which other CGS Combustible Gas Sensor part numbers can PE Energy supply?The 4 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description006824-011CGSS1C5C2R1X M20,FERRULES,CC006824-020CGSS1A6C2H1X, 3/4, 6LW, CC,H2006824-021CGSS1C3C2H1X, M20, 30LW, CC,H2006824-853CGSS1C6C2R1K,HOLD MCO100846 -

Det-Tronics Duct Mount and Sample Draw Assemblies for CGS
Direct Duct Mount Assembly (Spec Sheet: 90-1046). For mounting combustible sensors to air handling duct work. The Direct Duct Mount CGS assembly enables combustible gas detection in air handling, heating, ventilating, and air conditioning ducts. Designed for flat surface mounting only. Seal gaskets provided to prevent leakage Circular duct wall cutout required Positive pressure ducts only Calibration gas inlet enables in-situ calibration Flexible conduit/cabling recommended to enable sensor removal from assembly Model Q811 Duct Mount Enclosure (Manual: 95-8459) The Q811 provides combustible gas detection in air handling, heating, ventilating, and air conditioning ducts. Designed for flat surface mounting only Stainless steel NEMA 4X enclosure 316 Stainless steel enclosure and sample inlet tube spans the duct’s cross section 1 foot outlet tube returns the sample Requires a 600–4000 fpm velocity Sample Draw Cup Assembly for CGS. The Sample Draw cup assembly for CGS provides a sealed enclosure with compression fittings to enable the CGS to be used as part of an extractive gas sampling system. Aluminum enclosure with seals provides airtight flow chamber Brass compression fittings accept 1/4” OD tubing Threaded cover enables sensor removal Sampling system hardware required for proper operation Direct Duct Mount Assemblies for CGS Part Number Material Ship Weight 226846-001 AL 6 oz (0.17 kg) 226846-008 SS 1 lb (0.46 kg) Model Q811 CGS Duct Mount Enclosure Part Number Material Ship Weight Thread 000811-106 SS 10 lb (4.5 kg) M20 000811-105 SS 1 lb (0.46 kg) 3/4" NOTE: 1 inlet and 1 outlet tube included at no extra cost. Specify length of inlet tube at time of order (1, 3, 6, 10 or 13 ft). Q811 Spare Parts Part Number Description Length Material Ship Weight 000214-281 Inlet Tube 1 ft (0.3 m) 316 SS 8 oz (0.23 kg) 000214-282 Inlet Tube 3 ft (0.9 m) 316 SS 1 lb (0.45 kg) 000214-283 Inlet Tube 6 ft (1.8 m) 316 SS 3 lb (1.35 kg) 000214-284 Inlet Tube 10 ft (3.1 m) 316 SS 6 lb (2.4 kg) 000214-285 Inlet Tube 13 ft (4 m) 316 SS 9 lb (4.0 kg) 000214-419 Inlet Tube 15 ft (4.6 m) 316 SS 11 lb (5.0 kg) 000214-280 Outlet Tube 1 ft (0.3 m) 316 SS 8 oz (0.23 kg) 102359-001 Stopper Plug N/A Rubber <1 lb (<0.45 kg) Sample Draw Cup Assembly for CGS Part Number Material Ship Weight 009171-001 AL 1 lb (0.45 kg) -

Det-Tronics Electrochemical Sensor Cells for use with Model C7064E housings
Electrochemical sensor cells are provided for use with the C7064E (Spec Sheet: 90-1079) gas detector housings. All sensors are shipped in a sealed bag. Store in a cool, dry place until installation/commissioning is required. H2S Electrochemical Sensor Cell Part Number Toxic Gas Measurement Range (PPM) 005434-003 Hydrogen Sulfide 0-20 005434-004 Hydrogen Sulfide 0-50 005434-002 Hydrogen Sulfide 0-100 Shipping weight for sensor cells is 2 oz. (.1 kg) C7064E Calibration Gas Kits Part Number Concentration Gas Balance Ship Weight 227115-001 50 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-002 20 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-014 10 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-015 25 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-008 Empty kit - no cal gas 8.5 lb (3.9 kg) C7064E Calibration Gas Kit Replacement Cylinders Part Number Concentration Gas Balance Ship Weight 227117-001 50 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-002 20 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-011 10 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-012 25 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) C7064E Calibration Kit Replacement Parts Part Number Description Ship Weight 005964-001 C7064E Calibration cup 8 oz (0.23 kg) 101678-007 Tubing, 3 ft. 8 oz (0.23 kg) 101678-013 Tubing 100 ft. spool 8 oz (0.23 kg) 107427-084 C7064E Calibration cup O-ring 8 oz (0.23 kg) 162552-001 Regulator, 1 LPM 8 oz (0.23 kg) 162553-001 Carrying Case 8 oz (0.23 kg) -

Det-Tronics EQ3900G Power Distribution / Monitoring Enclosure Solution
This wall-mounted enclosure accommodates the Power Supply Monitor, terminal blocks, relays, circuit breakers, and fuses as physical space allows. Red Painted (RAL 3020) Steel Enclosure 20”(H) x 20”(W) x 8”(D) (508mm x 508mm x 203mm) Front Access Door with Locking Key Handle Passive Venting NEMA 4, IP66 No Viewing Window or Operators One EQ2100 PSM Power Supply Monitor installed Provides required isolation for high voltage circuitry Backup Battery Enclosure This wall-mounted enclosure holds up to four 12 Volt, sealed lead acid, top-post, 100AH batteries. Red Painted (RAL 3020) Steel Enclosure 30” (H) x 30” (W) x 8” (D) (762mm x 762mm x 203mm) One shelf Latching front access door Filtered vents NEMA 1 Which other EQ3900G Power Distribution / Monitoring Enclosure Solution part numbers can PE Energy supply?The 83 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description000392-0002EQ3900G RIO 2 AIM000392-0011EQ3900G RIO 1 RLY, 1 AIM000392-0101EQ3900G RIO 1 EDIO, 1 AIM000392-0110EQ3900G RIO 1 EDIO, 1 RLY000392-1002EQ3900G 1 EQP, 2 AIM000392-1011EQ3900G 1 EQP, 1 RLY, 1 AIM000392-1020EQ3900G 1EQP, 2 RELAY000392-1101EQ3900G 1 EQP, 1 EDIO, 1 AIM000392-1110EQ3900G 1 EQP 1 EDIO 1 RELAY000392-1200EQ3900G 1 EQP, 2 EDIO000393-0103EQ3900G,RIO,1 EDIO,3 AIM000393-0112EQ3900G,RIO,1 EDIO,1 RM,2 AIM000393-0121EQ3900G,RIO,1 EDIO,2 RM,1 AIM000393-0130EQ3900G,RIO,1 EDIO,3 RM000393-0202EQ3900G,RIO,2 EDIO,2 AIM000393-0211EQ3900G,RIO,2 EDIO,1 RM,1 AIM000393-0220EQ3900G,RIO,2 EDIO,2 RM000393-0301EQ3900G,RIO,3 EDIO,1 AIM000393-0310EQ3900G RIO 3 EDIO 1 RELAY000393-0400EQ3900G,RIO,4 EDIO000393-1103EQ3900G,1 EQP,1 EDIO,3 AIM000393-1112EQ3900G,1EQP,1 EDIO,1 RM,2 AIM000393-1121EQ3900G,1EQP,1 EDIO,2 RM,1 AIM000393-1130EQ3900G,1 EQP,1 EDIO,3 RM000393-1202EQ3900G,1 EQP,2 EDIO,2 AIM000393-1211EQ3900G,1EQP,2 EDIO,1 RM,1 AIM000393-1220EQ3900G,1 EQP,2 EDIO,2 RM000393-1301EQ3900G,1 EQP,3 EDIO,1 AIM000393-1310EQ3900G 1 EQP 3 EDIO 1 RELAY000393-1400EQ3900G,1 EQP,4 EDIO000393-2103EQ3900G,2 EQP,1 EDIO,3 AIM000393-2112EQ3900G,2EQP,1 EDIO,1 RM,2 AIM000393-2121EQ3900G,2EQP,1 EDIO,2 RM,1 AIM000393-2130EQ3900G,2 EQP,1 EDIO,3 RM000393-2202EQ3900G,2 EQP,2 EDIO,2 AIM000393-2211EQ3900G,2EQP,2 EDIO,1 RM,1 AIM000393-2220EQ3900G,2 EQP,2 EDIO,2 RM000393-2301EQ3900G,2 EQP,3 EDIO,1 AIM000393-2310EQ3900G 2 EQP 3 EDIO 1 RELAY000393-2400EQ3900G,2 EQP,4 EDIO000394-0204EQ3900G,RIO,2 EDIO,4 AIM000394-0213EQ3900G,RIO,2 EDIO,1 RM,3 AIM000394-0222EQ3900G,RIO,2 EDIO,2 RM,2 AIM000394-0240EQ3900G,RIO,2 EDIO,4 RM000394-0303EQ3900G,RIO,3 EDIO,3 AIM000394-0312EQ3900G,RIO,3 EDIO,1 RM,2 AIM000394-0321EQ3900G,RIO,3 EDIO,2 RM,1 AIM000394-0330EQ3900G,RIO,3 EDIO,3 RM000394-0402EQ3900G,RIO,4 EDIO,2 AIM000394-0411EQ3900G,RIO,4 EDIO,1 RM,1 AIM000394-0420EQ3900G,RIO,4 EDIO,2 RM000394-0501EQ3900G,RIO,5 EDIO,1 AIM000394-0510EQ3900G 5 EDIO 1 RELAY000394-0600EQ3900G,RIO,6 EDIO000394-1240EQ3900G,1 EQP, 2 EDIO, 4 RLY000394-1303EQ3900G,1EQP,3 EDIO,3 AIM000394-1312EQ3900G,1EQP,3 EDIO,1 RM,2 AIM000394-1321EQ3900G 1EQP,3 EDIO,2 RLY1AIM000394-1330EQ3900G 1 EQP, 3 EDIO. 3 RLY000394-1402EQ3900G 1 EQP, 4 EDIO, 2 AIM000394-1411EQ3900G 1EQP 4EDIO 1RLY 1AIM000394-1420EQ3900G 1 EQP, 4 EDIO, 2 RLY000394-1501EQ3900G 1 EQP, 5 EDIO, 1 AIM000394-1510EQ3900G 1 EQP 5 EDIO 1 RELAY000394-1600EQ3900G 1 EQP, 6 EDIO000394-2204EQ3900G,2 EQP,2 EDIO,4 AIM000394-2213EQ3900G,2EQP,2 EDIO,1 RM,3 AIM000394-2222EQ3900G,2EQP,2 EDIO,2 RM,2 AIM000394-2231EQ3900G,2EQP,2 EDIO,3 RM,1 AIM000394-2240EQ3900G,2 EQP,2 EDIO,4 RM000394-2303EQ3900G,2 EQP,3 EDIO,3 AIM000394-2312EQ3900G,2EQP,3 EDIO,1 RM,2 AIM000394-2321EQ3900G,2EQP,3 EDIO,2 RM,1 AIM000394-2330EQ3900G,2 EQP,3 EDIO,3 RM000394-2402EQ3900G,2 EQP,4 EDIO,2 AIM000394-2411EQ3900G,2EQP,4 EDIO,1 RM,1 AIM000394-2420EQ3900G,2 EQP,4 EDIO,2 RM000394-2501EQ3900G,2 EQP,5 EDIO,1 AIM000394-2510EQ3900G 2 EQP 5 EDIO 1 RELAY000394-2600EQ3900G 2 EQP 6 EDIO000851-001EQ3900G 10AMP PSM000851-002EQ3900G 30AMP PSM000851-003EQ3900G 75AMP PSM -

Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector
The FlexSight LS2000 Line-of-Sight Infrared Gas Detection System (Spec Sheet: 90-1215) is a stainless steel, IR beam-type hydrocarbon gas detection system. The system consists of two modules (transmitter and receiver) offering: Eagle Quantum Premier model Industry Leading Misalignment Tolerance: ±0.8 degrees (~±56cm @ 40m; ~±168cm @ 120m). Patented design. Compliance to ISA-12.13.04 performance standard Third party certified for Methane (default). Factory calibrated to Methane, Propane, and Butane Performance certified to EN60079-29-4 -55°C to +75°C certified temperature range Compliance to FM6325 and ISA-12.13.04 performance standards Certified SIL 2 capable Module separation distance range from 5-120 meters IR source: High performance, long lasting xenon flashlamp - 10 year warranty on IR source 5 year detector warranty Standard 4-20 mA output (configurable), HART communications (on receiver), RS485 Modbus Optional alarm relays (Ex d only) Easy Install / Alignment - Mounting / alignment hardware included with both modules - Built-in locking adjusters deliver fine control of alignment angles - Telescope alignment tool for accurate alignment - No HART or Software Interrogation tool needed Use of ‘Smart’ monitoring and control: maintains device temperature, heater obscuration triggers, drift / beam block tolerance, power supply and 4-20 mA monitoring, event logging, power consumption management Non-intrusive zero calibration options: on-board magnetic switch, HART communication, external switch, or MODBUS communication DNV Maritime approval Globally certified including SIL, FM, CSA, ATEX, IECEx, CE, DNV, INMETRO, and CUTR / KIM approvals Optional communication link provides: dynamic lamp power adjustments, synchronized LEDs, remote configuration read and calibration initiation from the transmitter LS2000 Model Matrix MODEL DESCRIPTION LS2000 Line-of-Sight Infrared Gas Detector TYPE MATERIAL S Stainless Steel TYPE CONDUIT ENTRY THREAD TYPE N 3/4" NPT, 4 Port Receiver, 2 Port Transmitter M Metric M25, 4 Port Receiver, 2 Port Transmitter TYPE OUTPUT 00 None (Transmitter only) 14 Eagle Quantum Premier (EQP) (Receiver or Kit) 18 4-20 mA, RS485, HART (Receiver or Kit) 25 4-20 mA, RS485, HART w/Optional Relays (Receiver or Kit) – Ex d only TYPE RANGE N None (Transmitter only) S Short Range, 5-60 Meters (Receiver or Kit) L Long Range, 30-120 Meters (Receiver or Kit) TYPE FACTORY SET TARGET GAS* N None (Transmitter only) M Methane (Receiver or Kit) P Propane (Receiver or Kit) B Butane (Receiver or Kit) TYPE APPROVALS† A FM/CSA B INMETRO E ATEX/IECEx R VNIIFTRI (RUSSIA) S SIL TYPE CLASSIFICATION 1 Division and/or Ex d e 2 Division and/or Ex d TYPE CONFIGURATION S Transmitter/Receiver/Mounting Hardware T Transmitter Only R Receiver Only TM Spare Transmitter Electronics Module RM Spare Receiver Electronics Module *The LS2000 is factory calibrated to M, P, and B gas types; this selection indicates which gas type the device will be configured to detect upon arrival. Users can change this selection via HART or MODBUS. †Type Approvals can use one or more letters to designate the approvals of the product. Typical LS2000 Customer Proposal Qty Model Part Number Description 1 LS2000SM18SMSE1S 012731-503 Consists of LS2000SM00NNSE1T Transmitter, LS2000SM18SMSE1R Receiver, and two Mounting & Alignment Brackets LS2000 - Complete Gas Detector Systems - SIL/FM/CSA Model Part Number Target Gas Range Threads Relay Output EQP Output DNV·GL Ex d e Ex d LS2000SN18SMSA1S 012731-401 Methane Short 3/4 NPT X X LS2000SM18SMSA1S 012731-403 M25 X X LS2000SN25SMSA2S 012731-426 3/4 NPT X X X LS2000SM25SMSA2S 012731-427 M25 X X X LS2000SN18SMSA2S 012731-402 3/4 NPT X X LS2000SN18LMSA1S 012731-451 Long 3/4 NPT X X LS2000SM18LMSA1S 012731-453 M25 X X LS2000SN25LMSA2S 012731-476 3/4 NPT X X X LS2000SM25LMSA2S 012731-477 M25 X X X LS2000SN18LMSA2S 012731-452 3/4 NPT X X LS2000SN14SMSA1S 011760-401 Methane Short 3/4 NPT X X X LS2000SM14SMSA1S 011760-403 M25 X X X LS2000SN14SMSA2S 011760-426 3/4 NPT X X X LS2000SM14SMSA2S 011760-427 M2511 X X X LS2000SN14LMSA1S 011760-451 Long 3/4 NPT X X X LS2000SM14LMSA1S 011760-453 M25 X X X LS2000SN14LMSA2S 011760-476 3/4 NPT X X X LS2000SM14LMSA2S 011760-477 M25 X X X LS2000SN18SPSA1S 012731-401P Propane Short 3/4 NPT X X LS2000SN25SPSA2S 012731-426P 3/4 NPT X X X LS2000SN18LPSA1S 012731-451P Long 3/4 NPT X X LS2000SN25LPSA2S 012731-476P 3/4 NPT X X X LS2000SN14SPSA1S 011760-401P Propane Short 3/4 NPT X X X LS2000SN14SPSA2S 011760-426P 3/4 NPT X X X LS2000SN14LPSA1S 011760-451P Long 3/4 NPT X X X LS2000SN14LPSA2S 011760-476P 3/4 NPT X X X LS2000SN18SBSA1S 012731-401B Butane Short 3/4 NPT X X LS2000SN25SBSA2S 012731-426B 3/4 NPT X X X LS2000SN18LBSA1S 012731-451B Long 3/4 NPT X X LS2000SN25LBSA2S 012731-476B 3/4 NPT X X X LS2000SN14SBSA1S 011760-401B Butane Short 3/4 NPT X X X LS2000SN14SBSA2S 011760-426B 3/4 NPT X X X LS2000SN14LBSA1S 011760-451B Long 3/4 NPT X X X LS2000SN14LBSA2S 011760-476B 3/4 NPT X X X Ship Weight = 85 lbs (38 kg) LS2000 - Complete Gas Detector Systems - SIL/ATEX/IECEx Model Part Number Target Gas Range Threads Relay Output EQP Output DNV·GL Ex d e Ex d LS2000SN18SMSE1S 012731-501 Methane Short 3/4 NPT X X LS2000SN18SMSE2S 012731-502 3/4 NPT X X LS2000SM18SMSE1S 012731-503 M25 X X LS2000SM18SMSE2S 012731-504 M25 X X LS2000SN25SMSE2S 012731-526 3/4 NPT X X X LS2000SM25SMSE2S 012731-527 M25 X X X LS2000SN18LMSE1S 012731-551 Long 3/4 NPT X X LS2000SN18LMSE2S 012731-552 3/4 NPT X X LS2000SM18LMSE1S 012731-553 M25 X X LS2000SM18LMSE2S 012731-554 M25 X X LS2000SN25LMSE2S 012731-576 3/4 NPT X X X LS2000SM25LMSE2S 012731-577 M25 X X X LS2000SN14SMSE1S 011760-501 Methane Short 3/4 NPT X X X LS2000SM14SMSE1S 011760-503 M25 X X X LS2000SN14SMSE2S 011760-526 3/4 NPT X X X LS2000SM14SMSE2S 011760-527 M25 X X X LS2000SN14LMSE1S 011760-551 Long 3/4 NPT X X X LS2000SM14LMSE1S 011760-553 M25 X X X LS2000SN14LMSE2S 011760-576 3/4 NPT X X X LS2000SM14LMSE2S 011760-577 M25 X X X LS2000SM18SPSE1S 012731-503P Propane Short M25 X X LS2000SM18SPSE2S 012731-504P M25 X X LS2000SM25SPSE2S 012731-527P M25 X X X LS2000SM18LPSE1S 012731-553P Long M25 X X LS2000SM18LPSE2S 012731-554P M25 X X LS2000SN25LPSE2S 012731-576P 3/4 NPT X X X LS2000SM25LPSE2S 012731-577P M25 X X X LS2000SM14SPSE1S 011760-503P Propane Short M25 X X X LS2000SM14SPSE2S 011760-527P M25 X X X LS2000SM14LPSE1S 011760-553P Long M25 X X X LS2000SM14LPSE2S 011760-577P M25 X X X LS2000SN18SBSE1S 012731-501B Butane Short 3/4 NPT X X LS2000SM18SBSE1S 012731-503B M25 X X LS2000SM18SBSE2S 012731-504B M25 X X LS2000SM25SBSE2S 012731-527B M25 X X X LS2000SN18LBSE1S 012731-551B 3/4 NPT X X LS2000SM18LBSE1S 012731-553B Long M25 X X LS2000SM18LBSE2S 012731-554B M25 X X LS2000SM25LBSE2S 012731-577B M25 X X X LS2000SM14SBSE1S 011760-503B Butane Short M25 X X X LS2000SM14SBSE2S 011760-527B M25 X X X LS2000SM14LBSE1S 011760-553B Long M25 X X X LS2000SM14LBSE2S 011760-577B M25 X X X Ship Weight = 85 lbs (38 kg) NOTE: All complete systems have a long range (L) of 30-120 meters or a short range (S) of 5-60 meters (apertures may be needed for shortest 15m of each range). The complete system includes a transmitter, receiver, aperture, and mounting hardware. LS2000 - Complete Gas Detector Systems - SIL/INMETRO Model Part Number Target Gas Range Threads Relay Output DNV Ex d e Ex d LS2000SN18SMSB1S 012731-201 Methane Short 3/4 NPT X X LS2000SN18SMSB2S 012731-202 3/4 NPT X X LS2000SN25SMSB2S 012731-226 3/4 NPT X X X LS2000SN18LMSB1S 012731-251 Long 3/4 NPT X X LS2000SN18LMSB2S 012731-252 3/4 NPT X X LS2000SN25LMSB2S 012731-276 3/4 NPT X X X LS2000SN18SPSB1S 012731-201P Propane Short 3/4 NPT X X LS2000SN18SPSB2S 012731-202P 3/4 NPT X X LS2000SN25SPSB2S 012731-226P 3/4 NPT X X X LS2000SN18LPSB1S 012731-251P Long 3/4 NPT X X LS2000SN18LPSB2S 012731-252P 3/4 NPT X X LS2000SN25LPSB2S 012731-276P 3/4 NPT X X X LS2000SN18SBSB1S 012731-201B Butane Short 3/4 NPT X X LS2000SN18SBSB2S 012731-202B 3/4 NPT X X LS2000SN25SBSB2S 012731-226B 3/4 NPT X X X LS2000SN18LBSB1S 012731-251B Long 3/4 NPT X X LS2000SN18LBSB2S 012731-252B 3/4 NPT X X LS2000SN25LBSB2S 012731-276B 3/4 NPT X X X Ship Weight = 85 lbs (38 kg) NOTE: All complete systems have a long range (L) of 30-120 meters or a short range (S) of 5-60 meters (apertures may be needed for shortest 15m of each range). The complete system includes a transmitter, receiver, aperture, and mounting hardware. LS2000 Transmitter Replacement - SIL/FM/CSA Model Part Number Threads DNV·GL Ex d e Ex d LS2000SN00NNSA1T 012020-401 3/4 NPT X X LS2000SN00NNSA2T 012020-402 3/4 NPT X X LS2000SM00NNSA1T 012020-403 M25 X X LS2000SM00NNSA2T 012020-404 M25 X X Ship Weight = 23 lbs (10.4 kg) NOTE: Spare transmitters do not include mounting hardware LS2000 Transmitter Replacement - SIL/ATEX/IECEx Model Part Number Threads DNV·GL Ex d e Ex d LS2000SN00NNSE1T 012020-501 3/4 NPT X X LS2000SN00NNSE2T 012020-502 3/4 NPT X X LS2000SM00NNSE1T 012020-503 M25 X X LS2000SM00NNSE2T 012020-504 M25 X X Ship Weight = 23 lbs (10.4 kg) NOTE: Spare transmitters do not include mounting hardware LS2000 Transmitter Replacement - SIL/INMETRO Model Part Number Threads DNV·GL Ex d e Ex d LS2000SN00NNSB1T 012020-201 3/4 NPT X X LS2000SN00NNSB2T 012020-202 3/4 NPT X X Ship Weight = 23 lbs (10.4 kg) NOTE: Spare transmitters do not include mounting hardware LS2000 - Receiver Replacement - SIL/FM/CSA Model Part Number Target Gas Range Threads Relay Output EQP Output Relay Output Relay Output Relay Output LS2000SN18SMSA1R 012097-401 Methane Short 3/4 NPT X X LS2000SN18SMSA2R 012097-402 3/4 NPT X X LS2000SM18SMSA1R 012097-403 M25 X X LS2000SN25SMSA2R 012097-426 3/4 NPT X X X LS2000SM25SMSA2R 012097-427 M25 X X X LS2000SN18LMSA1R 012097-451 Long 3/4 NPT X X LS2000SN18LMSA2R 012097-452 3/4 NPT X X LS2000SM18LMSA1R 012097-453 X X LS2000SN25LMSA2R 012097-476 3/4 NPT X X X LS2000SM25LMSA2R 012097-477 X X X LS2000SN14SMSA1R 011758-401 Methane Short 3/4 NPT X X X LS2000SM14SMSA1R 011758-403 X X X LS2000SN14SMSA2R 011758-426 3/4 NPT X X X LS2000SM14SMSA2R 011758-427 X X X LS2000SN14LMSA1R 011758-451 Long 3/4 NPT X X X LS2000SM14LMSA1R 011758-453 X X X LS2000SN14LMSA2R 011758-476 3/4 NPT X X X LS2000SM14LMSA2R 011758-477 X X X LS2000SN18SPSA1R 012097-401P Propane Short 3/4 NPT X X LS2000SN25SPSA2R 012097-426P 3/4 NPT X X X LS2000SN18LPSA1R 012097-451P 3/4 NPT X X LS2000SN25LPSA2R 012097-476P 3/4 NPT X X X LS2000SN14SPSA1R 011758-401P Propane Short 3/4 NPT X X X LS2000SN14SPSA2R 011758-426P 3/4 NPT X X X LS2000SN14LPSA1R 011758-451P Long 3/4 NPT X X X LS2000SN14LPSA2R 011758-476P 3/4 NPT X X X LS2000SN18SBSA1R 012097-401B Butane Short 3/4 NPT X X LS2000SN25SBSA2R 012097-426B 3/4 NPT X X X LS2000SN18LBSA1R 012097-451B Long 3/4 NPT X X LS2000SN25LBSA2R 012097-476B 3/4 NPT X X X LS2000SN14SBSA1R 011758-401B Butane Short 3/4 NPT X X X LS2000SN14SBSA2R 011758-426B 3/4 NPT X X X LS2000SN14LBSA1R 011758-451B Long 3/4 NPT X X X LS2000SN14LBSA2R 011758-476B 3/4 NPT X X X Ship Weight = 20 lbs (9 kg) NOTE: Spare receivers do not include mounting hardware LS2000 - Receiver Replacement - SIL/ATEX/IECEx Model Part Number Target Gas Range Threads Relay Output EQP Output DNV·GL Ex d e Ex d LS2000SN18SMSE1R 012097-501 Methane Short 3/4 NPT X X LS2000SN18SMSE2R 012097-502 3/4 NPT X X LS2000SM18SMSE1R 012097-503 M25 X X LS2000SM18SMSE2R 012097-504 M25 X X LS2000SN25SMSE2R 012097-526 3/4 NPT X X X LS2000SM25SMSE2R 012097-527 M25 X X X LS2000SN18LMSE1R 012097-551 Long 3/4 NPT X X LS2000SN18LMSE2R 012097-552 3/4 NPT X X LS2000SM18LMSE1R 012097-553 M25 X X LS2000SM18LMSE2R 012097-554 M25 X X LS2000SN25LMSE2R 012097-576 3/4 NPT X X X LS2000SM25LMSE2R 012097-577 M25 X X X LS2000SN14SMSE1R 011758-501 Methane Short 3/4 NPT X X X LS2000SM14SMSE1R 011758-503 M25 X X X LS2000SN14SMSE2R 011758-526 3/4 NPT X X X LS2000SM14SMSE2R 011758-527 M25 X X X LS2000SN14LMSE1R 011758-551 Long 3/4 NPT X X X LS2000SM14LMSE1R 011758-553 M25 X X X LS2000SN14LMSE2R 011758-576 3/4 NPT X X X LS2000SM14LMSE2R 011758-577 M25 X X X LS2000SM18SPSE1R 012097-503P Propane Short M25 X X LS2000SM18SPSE2R 012097-504P M25 X X LS2000SM25SPSE2R 012097-527P M25 X X X LS2000SM18LPSE1R 012097-553P Long M25 X X LS2000SM18LPSE2R 012097-554P M25 X X LS2000SN25LPSE2R 012097-576P 3/4 NPT X X X LS2000SM25LPSE2R 012097-577P M25 X X X LS2000SM14SPSE1R 011758-503P Propane Short M25 X X X LS2000SM14SPSE2R 011758-527P M25 X X X LS2000SM14LPSE1R 011758-553P Long M25 X X X LS2000SM14LPSE2R 011758-577P M25 X X X LS2000SM18SBSE1R 012097-503B Butane Short M25 X X LS2000SM18SBSE2R 012097-504B M25 X X LS2000SM25SBSE2R 012097-527B M25 X X X LS2000SM18LBSE1R 012097-553B Long M25 X X LS2000SM18LBSE2R 012097-554B M25 X X LS2000SM25LBSE2R 012097-577B M25 X X X LS2000SM14SBSE1R 011758-503B Butane Short M25 X X X LS2000SM14SBSE2R 011758-527B M25 X X X LS2000SM14LBSE1R 011758-553B Long M25 X X X LS2000SM14LBSE2R 011758-577B M25 X X X Ship Weight = 20 lbs (9 kg) NOTE: Spare receivers do not include mounting hardware LS2000 - Receiver Replacement - SIL/INMETRO Model Part Number Target Gas Range Threads Relay Output DNV Ex d e Ex d LS2000SN18SMSB1R 012097-201 Methane Short 3/4 NPT X X LS2000SN18SMSB2R 012097-202 3/4 NPT X LS2000SN25SMSB2R 012097-226 3/4 NPT X X X LS2000SN18LMSB1R 012097-251 Long 3/4 NPT X X LS2000SN18LMSB2R 012097-252 3/4 NPT X LS2000SN25LMSB2R 012097-276 3/4 NPT X X X LS2000SN18SPSB1R 012097-201P Propane Short 3/4 NPT X X LS2000SN18SPSB2R 012097-202P 3/4 NPT X LS2000SN25SPSB2R 012097-226P 3/4 NPT X X X LS2000SN18LPSB1R 012097-251P Long 3/4 NPT X X LS2000SN18LPSB2R 012097-252P 3/4 NPT X LS2000SN25LPSB2R 012097-276P 3/4 NPT X X X LS2000SN18SBSB1R 012097-201B Butane Short 3/4 NPT X X LS2000SN18SBSB2R 012097-202B 3/4 NPT X LS2000SN25SBSB2R 012097-226B 3/4 NPT X X X LS2000SN18LBSB1R 012097-251B Long 3/4 NPT X X LS2000SN18LBSB2R 012097-252B 3/4 NPT X LS2000SN25LBSB2R 012097-276B 3/4 NPT X X X Ship Weight = 20 lbs (9 kg) NOTE: Spare receivers do not include mounting hardware LS2000 Spare Transmitter Module - SIL/FM/CSA Model Part Number Threads DNV·GL Ex d e Ex d LS2000SN00NNSA1TM 012713-401 3/4 NPT X X LS2000SN00NNSA2TM 012713-402 3/4 NPT X X LS2000SM00NNSA1TM 012713-403 M25 X X LS2000SM00NNSA2TM 012713-404 M25 X X Ship Weight = 10.4 lbs (4.7 kg) NOTE: Includes front electronics module only LS2000 Spare Transmitter Module - SIL/ATEX/IECEx Model Part Number Threads DNV·GL Ex d e Ex d LS2000SN00NNSE1TM 012713-501 3/4 NPT X X LS2000SN00NNSE2TM 012713-502 3/4 NPT X X LS2000SM00NNSE1TM 012713-503 M25 X X LS2000SM00NNSE2TM 012713-504 M25 X X Ship Weight = 10.4 lbs (4.7 kg) NOTE: Includes front electronics module only LS2000 Spare Transmitter Module - SIL/INMETRO Model Part Number Threads DNV·GL Ex d e Ex d LS2000SN00NNSB1TM 012713-201 3/4 NPT X X LS2000SN00NNSB2TM 012713-202 3/4 NPT X X Ship Weight = 10.4 lbs (4.7 kg) NOTE: Includes front electronics module only LS2000 Spare Receiver Modules - SIL/FM/CSA Model Part Number Target Gas Range Threads Relay Output EQP Output DNV·GL Ex d e Ex d LS2000SN18SMSA1RM 012714-401 Methane Short 3/4 NPT X X LS2000SM18SMSA1RM 012714-403 M25 X X LS2000SN25SMSA2RM 012714-426 3/4 NPT X X X LS2000SM25SMSA2RM 012714-427 M25 X X X LS2000SN14SMSA1RM 011759-401 3/4 NPT X X X LS2000SM14SMSA1RM 011759-403 M25 X X X LS2000SN14SMSA2RM 011759-426 3/4 NPT X X X LS2000SM14SMSA2RM 011759-427 M25 X X X LS2000SN18LMSA1RM 012714-451 Long 3/4 NPT X X LS2000SM18LMSA1RM 012714-453 M25 X X LS2000SN25LMSA2RM 012714-476 3/4 NPT X X X LS2000SM25LMSA2RM 012714-477 M25 X X X LS2000SN14LMSA1RM 011759-451 3/4 NPT X X X LS2000SM14LMSA1RM 011759-453 M25 X X X LS2000SN14LMSA2RM 011759-476 3/4 NPT X X X LS2000SM14LMSA2RM 011759-477 M25 X X X LS2000SN18SPSA1RM 012714-401P Propane Short 3/4 NPT X X LS2000SN25SPSA2RM 012714-426P 3/4 NPT X X X LS2000SN14SPSA1RM 011759-401P 3/4 NPT X X X LS2000SN14SPSA2RM 011759-426P 3/4 NPT X X X LS2000SN18LPSA1RM 012714-451P Long 3/4 NPT X X LS2000SN25LPSA2RM 012714-476P 3/4 NPT X X X LS2000SN14LPSA1RM 011759-451P 3/4 NPT X X X LS2000SN14LPSA2RM 011759-476P 3/4 NPT X X X LS2000SN18SBSA1RM 012714-401B Butane Short 3/4 NPT X X LS2000SN25SBSA2RM 012714-426B 3/4 NPT X X X LS2000SN14SBSA1RM 011759-401B 3/4 NPT X X X LS2000SN14SBSA2RM 011759-426B 3/4 NPT X X X LS2000SN18LBSA1RM 012714-451B Long 3/4 NPT X X LS2000SN25LBSA2RM 012714-476B 3/4 NPT X X X LS2000SN14LBSA1RM 011759-451B 3/4 NPT X X X LS2000SN14LBSA2RM 011759-476B 3/4 NPT X X X Ship Weight = 7.8 lbs (3.6 kg) NOTE: Includes front electronics module only LS2000 Spare Receiver Modules - SIL/ATEX/IECEx Model Part Number Target Gas Range Threads Relay Output EQP Output DNV·GL Ex d e Ex d LS2000SN18SMSE1RM 012714-501 Methane Short 3/4 NPT X X LS2000SN18SMSE2RM 012714-502 3/4 NPT X X LS2000SM18SMSE1RM 012714-503 M25 X X LS2000SM18SMSE2RM 012714-504 M25 X X LS2000SN25SMSE2RM 012714-526 3/4 NPT X X X LS2000SM25SMSE2RM 012714-527 M25 X X X LS2000SN14SMSE1RM 011759-501 3/4 NPT X X X LS2000SM14SMSE1RM 011759-503 M25 X X X LS2000SN14SMSE2RM 011759-526 3/4 NPT X X X LS2000SM14SMSE2RM 011759-527 M25 X X X LS2000SN18LMSE1RM 012714-551 Long 3/4 NPT X X LS2000SN18LMSE2RM 012714-552 3/4 NPT X X LS2000SM18LMSE1RM 012714-553 M25 X X LS2000SM18LMSE2RM 012714-554 M25 X X LS2000SN25LMSE2RM 012714-576 3/4 NPT X X X LS2000SM25LMSE2RM 012714-577 M25 X X X LS2000SN14LMSE1RM 011759-551 3/4 NPT X X X LS2000SM14LMSE1RM 011759-553 M25 X X X LS2000SN14LMSE2RM 011759-576 3/4 NPT X X X LS2000SM14LMSE2RM 011759-577 M25 X X X LS2000SM18SPSE1RM 012714-503P Propane Short M25 X X LS2000SM18SPSE2RM 012714-504P M25 X X LS2000SM25SPSE2RM 012714-527P M25 X X X LS2000SM14SPSE1RM 011759-503P M25 X X X LS2000SM14SPSE2RM 011759-527P M25 X X X LS2000SM18LPSE1RM 012714-553P Long M25 X X LS2000SM18LPSE2RM 012714-554P M25 X X LS2000SM25LPSE2RM 012714-577P M25 X X X LS2000SM14LPSE1RM 011759-553P M25 X X X LS2000SM14LPSE2RM 011759-577P M25 X X X LS2000SM18SBSE1RM 012714-503B Butane Short M25 X X LS2000SM18SBSE2RM 012714-504B M25 X X LS2000SM25SBSE2RM 012714-527B M25 X X X LS2000SM14SBSE1RM 011759-503B M25 X X X LS2000SM14SBSE2RM 011759-527B M25 X X X LS2000SM14SBSE1RM 011759-503B M25 X X X LS2000SM14SBSE2RM 011759-527B M25 X X X LS2000SM18LBSE1RM 012714-553B Long M25 X X LS2000SM18LBSE2RM 012714-554B M25 X X LS2000SM25LBSE2RM 012714-577B M25 X X X LS2000SM14LBSE1RM 011759-553B M25 X X X LS2000SM14LBSE2RM 011759-577B M25 X X X Ship Weight = 7.8 lbs (3.6 kg) NOTE: Includes front electronics module only LS2000 Spare Receiver Modules - SIL/INMETRO Model Part Number Target Gas Range Threads Relay Output DNV Ex d e Ex d LS2000SN18SMSB1RM 012714-201 Methane Short 3/4 NPT X X LS2000SN18SMSB2RM 012714-202 3/4 NPT X X LS2000SN25SMSB2RM 012714-226 3/4 NPT X X X LS2000SN18LMSB1RM 012714-251 Long 3/4 NPT X X LS2000SN18LMSB2RM 012714-252 3/4 NPT X X LS2000SN25LMSB2RM 012714-276 3/4 NPT X X X LS2000SN18SPSB1RM 012714-201P Propane Short 3/4 NPT X X LS2000SN18SPSB2RM 012714-202P 3/4 NPT X X LS2000SN25SPSB2RM 012714-226P 3/4 NPT X X X LS2000SN18LPSB1RM 012714-251P Long 3/4 NPT X X LS2000SN18LPSB2RM 012714-252P 3/4 NPT X X LS2000SN25LPSB2RM 012714-276P 3/4 NPT X X X LS2000SN18SBSB1RM 012714-201B Butane Short 3/4 NPT X X LS2000SN18SBSB2RM 012714-202B 3/4 NPT X X LS2000SN25SBSB2RM 012714-226B 3/4 NPT X X X LS2000SN18LBSB1RM 012714-251B Long 3/4 NPT X X LS2000SN18LBSB2RM 012714-252B 3/4 NPT X X LS2000SN25LBSB2RM 012714-276B 3/4 NPT X X X Ship Weight = 7.8 lbs (3.6 kg) NOTE: Includes front electronics module only LS2000 Accessories Part Number Description 012287-002 LS2000 Alignment Tool 012673-001 System Test Film, (set of 5 films) 103922-003 AMS Trex Device Communicator 014020-001 W6300G1006 Gas Inspector II Kit (PC software and connection hardware included) 009246-003 High Range LS2000 Gas Test Cell (0.125) 009246-001 Low Range OPECL Gas Test Cell 009246-002 High Range OPECL Gas Test Cell 009246-004 Gas Test Cell, LS2000 Methane IEC 009246-005 Gas Test Cell, LS2000 Propane ISO 009246-006 Gas Test Cell, LS2000 Propane IEC 009246-007 Gas Test Cell, LS2000 Butane ISO 009246-008 Gas Test Cell, LS2000 Butane IEC 012840-001 Gas Cell Adapter (converts OPECL Test Cell to mount on LS2000 Rx) 012718-003 Flat Surface Adapter Plate (converts OPECL flat surface mounting to LS2000) 012790-001 Thermal Shield for Right Module* 012791-001 Thermal Shield for Left Module* * Two Thermal Shields required per complete LS2000 system (one right and one left) LS2000 Spare Parts Part Number Description 102740-002 Calibration Magnet* 011773-001 Short Range Aperture† 012300-001 Spare Brow, Rx 012312-001 Spare Brow, Tx 400525-023 Spare M8 Flange Bolt for Tx Module 012660-001 Spare Mounting & Alignment Bracket (for one module only) 103578-001 Anti-seize Lubricant Packet 006680-001 Grease Kit, Silicone 104346-154 O-Ring, 3.75” i.d., for wiring compartment cover 104346-046 O-Ring, 4.25", for front flange Transmitter *1 magnet ships with each individual order of an LS2000 Kit or Receiver free of charge. †Qty 1 aperture is provided with each LS2000 Transmitter Which other FlexSight LS2000 Line-of-Sight Infrared Gas Detector part numbers can PE Energy supply?The 19 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description011760-626LS2000SN14SMSB2S LINE OF SIGHT011760-676LS2000SN14LMSB2S LINE OF SIGHT011760-977LS2000SM14LMSR2S LINE OF SIGHT012020-803LS2000SM00NNSK1T TX012020-903LS2000SM00NNSR1T TX012097-803LS2000SM18SMSK1R RX012097-853LS2000SM18LMSK1R RX012097-927LS2000SM25SMSR2R RX012097-953LS2000SM18LMSR1R RX012097-954LS2000SM18LMSR2R RX012713-803LS2000SM00NNSK1TM SPARE TX MOD012714-803LS2000SM18SMSK1RM SPARE RX012714-853LS2000SM18LMSK1RM SPARE RX012731-853LS2000SM18LMSK1S LINE OF SIGHT012731-904LS2000SM18SMSR2S LINE OF SIGHT012731-905LS2000SM18SMSR1S LINE OF SIGHT012731-927LS2000SM25SMSR2S LINE OF SIGHT012731-953LS2000SM18LMSR1S LINE OF SIGHT012731-954LS2000SM18LMSR2S LINE OF SIGHT -

Det-Tronics FlexSonic Acoustic Detector
The FlexSonic® Acoustic Detector – comprised of the AC100 Acoustic Sensor and the ATX10 Acoustic Transmitter (Spec Sheet: 90-1208) is designed to recognize the unique frequency content of events such as gas leaks. When a pressurized gas leak occurs, the frequency content of the sound being generated extends beyond the audible portion of the spectrum into the ultrasonic region (above 20 kHz). The intensity of the sound generated by a leak is determined by several factors including pressure differential, leak rate, gas viscosity, and distance from the leak source. Acoustic detection is less susceptible to environmental factors (such as high winds) that can degrade the ability of traditional sensing technology based on gas concentration to detect the presence of a leak. When combined with line-of-sight and/or point gas detectors, the additional layer of protection provided by the FlexSonic Acoustic Detector offers the ultimate solution for gas leak detection. Analyzes 24 discrete ultrasonic bands Nearly instantaneous response Non-contact gas leak detection 4-20 mA output combined with HART Can detect small gas leaks at or below 6 bar (87 psi) Extensive data logging with removable storage that records the acoustic spectrum Superior false alarm discrimination with patented technology Ideally suited for locations where traditional technologies are challenged, such as outdoor and unmanned operations Large detection coverage area FM, CSA, ATEX, and IECEx Certified SIL 2 Capable for all gas types Globally approved Explosion-proof 316 stainless steel housing Integrated Acoustic Integrity Check (AIC) No routine calibration required Not affected by poisoning FlexSonic AC100/ATX10 Kits Part Number Description Consists of: SIL/FM/CSA/ ATEX/IECEx SIL/ INMETRO SIL/ VNIIFTRI 012152-001 AC100/ATX Kit, 3/4" NPT AC100SNT2 ATX10S5N26T X 012153-001 AC100/ATX Kit, M25 AC100SMT2 ATX10S5M26T X 012152-601 AC100/ATX Kit, 3/4" NPT AC100SNSB2 ATX10S5N26SB X 012153-601 AC100/ATX Kit, M25 AC100SMSB2 ATX10S5M26SB X 012153-901 AC100/ATX Kit, M25 AC100SMSR2 ATX10S5M26SR X Kit includes individually packaged AC100 and ATX10. Typical FlexSonic Customer Proposal Qty Model Part Number Description 1 AC100/ATX10 KIT, M25 012153-001 Consists of AC100SMT2 and ATX10S5M26T Spare Parts Qty Model Part Number Description 1 N/A 104155-001 Micro SDHC Card, 4GB Industrial Temperature Rating 1 N/A 009700-001 Magnetic Tool Accessories Qty Part Number Description 1 104218-001 35mm Socket for use with M25 model 1 012401-001 Acoustic Configurator Package 2 101197-003 Stop Plug, M25, SS, IP66 FlexSonic AC100 Model Matrix MODEL DESCRIPTION AC100 Acoustic Sensor TYPE MATERIAL S Stainless Steel TYPE THREAD TYPE N 3/4" NPT M M25 TYPE APPROVALS* B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx TYPE CLASSIFICATION 2 Division/Zone Ex d *Type Approvals can use one or more letters to designate the approvals of the product. FlexSonic AC100 Acoustic Sensor Model Part Number Threads Ex d SIL/FM/CSA/ATEX/IECEx SIL/INMETRO SIL/VNIIFTRI AC100SNT2 010567-003 3/4" NPT X X AC100SMT2 010567-004 M25 X X AC100SNSB2 010567-603 3/4" NPT X X AC100SMSB2 010567-604 M25 X X AC100SMSR2 010567-904 M25 X X Ship Weight: 6.2 lb (2.8 kg) NOTE: Above part numbers do not include foam insert. AC100 Spare Parts Part Number Description Ship Weight 011355-001 Foam Insert <1lb (<0.45 kg) AC100 Accessories Part Number Description Ship Weight 104218-001 35mm Socket for use with M25 model 1.8 lb (<0.8 kg) 226365-601 STB7A5YW, AL, M25 2.2 lb (1.0 kg) 226365-602 STB7A5NW, AL, 3/4 NPT 2.2 lb (1.0 kg) 226365-603 STB7S5YW, SS, M25 3.0 lb (1.4 kg) 226365-604 STB7S5NW, SS, 3/4 NPT 3.0 lb (1.4 kg) 226365-606 STB7A5NB ,AL, 3/4, INMETRO 2.2 lb (1.0 kg) 226365-607 STB7S5NB, SS, 3/4, INMETRO 3.0 lb (1.4 kg) 226365-963 STB7S5YR,SS,M25,RUSSIA 3.0 lb (1.4 kg) FlexSonic ATX10 Model Matrix MODEL DESCRIPTION ATX10 AC100 Transmitter TYPE MATERIAL S Stainless Steel TYPE # OF OPEN PORTS 5 5 Port TYPE THREAD TYPE N 3/4" NPT M M25 TYPE OUTPUT 26 4-20 mA w/HART Protocol TYPE APPROVALS* B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx *Type Approvals can use one or more letters to designate the approvals of the product. FlexSonic ATX10 Transmitter for AC100 Model Part Number Threads 4-20 RS485 HART Ex d SIL/FM/CSA/ATEX/IECEx SIL/INMETRO SIL/VNIIFTRI ATX10S5N26T 011942-001 3/4 NPT X X X ATX10S5M26T 011942-002 M25 X X X ATX10S5N26SB 011942-601 3/4 NPT X X X ATX10S5M26SB 011942-602 M25 X X X ATX10S5M26SR 011942-902 M25 X X X Ship Weight: 11.5 lb (5.2 kg) ATX10 Spare Parts Part Number Description Ship Weight 010969-001 ATX10 Replacement Module 1 lb (0.45 kg) 011365-102 ATX10 Memory Module Assembly (SD Card not included) 1 lb (0.45 kg) 104155-001 Micro SDHC Card, 4G, Industrial Temperature Rating <1lb (<0.45kg) 103028-027 Plug, 5mm, 4 Position - P1 <1lb (<0.45kg) 103028-028 Plug, 5mm, 5 Position - J3 <1lb (<0.45kg) ATX10 Accessories Part Number Description Ship Weight 012400-001 Acoustic Inspector Package <1lb (<0.45kg) 012401-001 Acoustic Configurator Package <1lb (<0.45kg) 012402-001 W6300G1004 Acoustic Software Connector (software not included) 1 lb (0.45 kg) 009700-001 Magnetic Tool <1lb (<0.45kg) 104218-001 35mm Socket for use with M25 model 1.8 lb (<0.8 kg) Stop Plugs Part Number Description Ship Weight 101197-004* Stop Plug, 3/4" NPT, SS <1 lb (<0.45 kg) 101197-003 Stop Plug, M25, SS, IP66 <1 lb (<0.45 kg) 010817-001* Stop Plug, 20 Pack, 3/4"NPT, SS 2 lb (0.9 kg) 010819-001 Stop Plug, 20 Pack, M25, SS,IP66 3.25 lb (1.5 kg) *NEMA Type 4X/IP66 rating requires Teflon tape. -

Det-Tronics FlexVu UD10 Universal Display (for Toxics)
FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications where a gas detector with digital read-out of detected gas levels are required. The FlexVu UD10 Universal Display Unit is designed for use with various Det-Tronics toxic gas sensor/transmitters such as GT3000, NTMOS or C706x. The display unit is designed and approved as a stand alone controller and performs all the functions of a gas controller. Compliance to ISA-92.0.01 Part 1 performance standard, and EN50104 for oxygen depletion Division Approval Ratings: FM and CSA Zone Approval Ratings: FM, CSA, ATEX, and IECEx DNV type approval - maritime/offshore Eagle Quantum Premier model Universal design supports a variety of Det-Tronics sensors/detectors Non-intrusive menu allows device configuration and calibration without de-classifying the hazardous area Continuously displays gas level, gas type, and units measured Data logger for event time and date stamping Heated backlit display Relay, modbus, and linear isolated/non-isolated 4-20 mA output with HART, configurable 4-20 mA output loop monitoring IP66 rated FlexVu UD10 Model Matrix MODEL DESCRIPTION UD10 Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 25 Relay, 4-20mA, RS485, HART 28 EQP / DCU Emulator TYPE APPROVALS* B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/ICEx TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) TYPE OPTIONAL CONDITIONING BOARD N NTMOS† * Type Approvals can use one or more letters to designate the approvals of the product. † Not required for DCU Emulator model. FlexVu UD10 Universal Display - Toxics Model Part Number Material Threads Relay 4-20 RS485 HART EQP DCU Emulator Cond. Board FM/CSA/ ATEX/ IECEx SIL 2 UD10A5M25T2 010765-001 AL M25 X X X UD10A5N25T2 010765-002 AL 3/4 NPT X X X UD10S5M25T2 010765-003 316 SS M25 X X X UD10S5N25T2 010765-004 316 SS 3/4 NPT X X X UD10A5M28W2 010765-005 AL M25 X X UD10A5N28W2 010765-006 AL 3/4 NPT X X UD10S5M28W2 010765-007 316 SS M25 X X UD10S5N28W2 010765-008 316 SS 3/4 NPT X X UD10A5M25W2N 010252-001 AL M25 X NTMOS X UD10A5N25W2N 010252-002 AL 3/4 NPT X NTMOS X UD10S5M25W2N 010252-003 316 SS M25 X NTMOS X UD10S5N25W2N 010252-004 316 SS 3/4 NPT X NTMOS X Ship Weight: Aluminum = 4.2lb (1.9kg) Stainless Steel = 10.5lb (4.8kg) FlexVu UD10 Spare Modules Part Number Description Output Ship Weight 010569-001 UD10 Display Module Relay/4-20mA 1 lb (0.45 kg) 010535-001 UD10 Display Module EQP-DCU 1 lb (0.45 kg) FlexVu UD10 Accessories Part Number Description Ship Weight 009700-001 Magnetic Tool <1 lb (0.45 kg) 014019-001 Gas Inspector 11 CD <1 lb (0.45 kg) 014020-001 W6300G1006 Gas Inspector 11 Kit (includes CD) <1 lb (0.45 kg) 102988-002 Plug, 5.0mm, 6 Position - P2 <1 lb (0.45 kg) 102988-026 Plug, 5.0mm, 3 Position - P1 (J10, CGS) <1 lb (0.45 kg) 102988-028 Plug, 5.0mm, 5 Position - (J3, CGS) <1 lb (0.45 kg) 103726-002 Plug, 3.5mm, 3 Position - J2 <1 lb (0.45 kg) 103726-004 Plug, 3.5mm, 5 Position - J3 <1 lb (0.45 kg) 103726-011 Plug, 3.5mm, 12 Position - J4 <1 lb (0.45 kg) FlexVu UD10 Miscellaneous Spare Parts Part Number Description Ship Weight 011919-001 UD10/NTMOS REPLACEMENT BOARD <1 lb (<0.45 kg) Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* Stop Plug, 3/4" NPT, AL <1 lb (<0.45 kg) 101197-004* Stop Plug, 3/4" NPT, SS <1 lb (<0.45 kg) 101197-005 Stop Plug, M25, AL, IP66 <1 lb (<0.45 kg) 101197-003 Stop Plug, M25, SS, IP66 <1 lb (<0.45 kg) 010816-001* Stop Plug, 20 Pack, 3/4"NPT, AL 1 lb (0.45 kg) 010817-001* Stop Plug, 20 Pack, 3/4"NPT, SS 2 lb (0.9 kg) 010818-001 Stop Plug, 20 Pack, M25, AL,IP66 1.5 lb (0.7 kg) 010819-001 Stop Plug, 20 Pack, M25, SS,IP66 3.25 lb (1.5 kg) 102804-001 Reducer, M25 to M20, AL <1 lb (<0.45 kg) 102804-003 Reducer, M25 to M20, SS <1 lb (<0.45 kg) *NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape. FlexVu® UD10 Universal Display Repair / Upgrade Kit (Technical Bulletin: 76-1046) The UD10 Repair/Upgrade Kit allows field conversion of an existing U9500 Infiniti®Transmitter, Model 505 Transmitter, or Eagle Quantum Premier® Digital Communication Unit (DCU) to a FlexVu® UD10 Universal Display. The existing junction box base, along with the existing conduit and field wiring, can be left in place and do not need to be replaced. FlexVu UD10 Upgrade Kit - Toxics Model Part Number Material Threads Relay 4-20 RS485 HART EQP DCU Emulator FM/CSA/ ATEX/ IECEx SIL 2 UPGRADE KIT UD10A5M25T2 010970-001 AL M25 X X X UPGRADE KIT UD10A5N25T2 010970-002 AL 3/4 NPT X X X UPGRADE KIT UD10S5M25T2 010970-003 316 SS M25 X X X UPGRADE KIT UD10S5N25T2 010970-004 316 SS 3/4 NPT X X X UPGRADE KIT UD10A5M28W2 010970-005 AL M25 X X UPGRADE KIT UD10A5N28W2 010970-006 AL 3/4 NPT X X UPGRADE KIT UD10S5M28W2 010970-007 316 SS M25 X X UPGRADE KIT UD10S5N28W2 010970-008 316 SS 3/4 NPT X X Ship Weight: Aluminum = 3.5lb (1.6kg) Stainless Steel = 8.7lb (3.9kg) -

Det-Tronics FlexVu UD10 Universal Display
FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications that require a gas detector with digital read-out of detected gas levels. The FlexVu UD10 Universal Display Unit is designed for use with various Det-Tronics gas sensor/transmitters. The display unit is designed and approved as a stand-alone device and performs all the functions of a gas controller. Compliance to ANSI/ISA-12.13.01-2000 performance standard Compliance to ISA-92.0.01 Part 1 performance standard, and EN50104 for oxygen depletion Performance certified to FM 6310/6320, CSA 22.2 #152, ATEX EN60079-29-1, and IEC60079-29-1 Approved as a stand-alone combustible gas and low concentration toxic controller, when using the relay contacts Division Approval Ratings: FM and CSA Zone Approval Ratings: FM, CSA, ATEX, and IECEx Eagle Quantum Premier model Universal design supports a variety of Det-Tronics sensors/detectors Non-intrusive menu allows device configuration and calibration without de-classifying the hazardous area Continuously displays gas level, gas type, and units measured Data logger for event time and date stamping Heated and backlit display Relay, modbus, and linear isolated/non-isolated 4-20 mA output with HART, configurable 4-20 mA output loop monitoring IP66 rated FlexVu UD10 Model Matrix MODEL DESCRIPTION UD10 Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 25 Relay, 4-20mA, RS485, HART 28 EQP / DCU Emulator TYPE APPROVALS* B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) TYPE OPTIONAL CONDITIONING BOARD (Blank) None C CGS N NTMOS† * Type Approvals can use one or more letters to designate the approvals of the product. † Not required for DCU Emulator model. FlexVu UD10 Universal Display Model Part Number Material Threads Relay 4-20 RS485 HART EQP/DCU Emulator Cond. Board FM/CSA/ ATEX/IECEx SIL 2 UD10A5M25T2 010765-001 AL M25 X X X UD10A5N25T2 010765-002 AL 3/4 NPT X X X UD10S5M25T2 010765-003 316 SS M25 X X X UD10S5N25T2 010765-004 316 SS 3/4 NPT X X X UD10A5M28W2 010765-005 AL M25 X X UD10A5N28W2 010765-006 AL 3/4 NPT X X UD10S5M28W2 010765-007 316 SS M25 X X UD10S5N28W2 010765-008 316 SS 3/4 NPT X X UD10A5M25W2C 010254-001 AL M25 X CGS X UD10A5N25W2C 010254-002 AL 3/4 NPT X CGS X UD10S5M25W2C 010254-003 316 SS M25 X CGS X UD10S5N25W2C 010254-004 316 SS 3/4 NPT X CGS X UD10A5M28W2C 010254-005 AL M25 X CGS X UD10A5N28W2C 010254-006 AL 3/4 NPT X CGS X UD10S5M28W2C 010254-007 316 SS M25 X CGS X UD10S5N28W2C 010254-008 316 SS 3/4 NPT X CGS X UD10A5M25W2N 010252-001 AL M25 X NTMOS X UD10A5N25W2N 010252-002 AL 3/4 NPT X NTMOS X UD10S5M25W2N 010252-003 316 SS M25 X NTMOS X UD10S5N25W2N 010252-004 316 SS 3/4 NPT X NTMOS X Ship Weight: Aluminum = 4.2lb (1.9kg) Stainless Steel = 10.5lb (4.8kg) FlexVu UD10 Spare Modules Part Number Description Output Ship Weight 010569-001 UD10 Display Module Relay/4-20mA 1 lb (0.45 kg) 010535-001 UD10 Display Module EQP-DCU 1 lb (0.45 kg) FlexVu UD10 Miscellaneous Spare Parts Part Number Description Ship Weight 011919-001 UD10/NTMOS REPLACEMENT BOARD <1 lb (<0.45 kg) FlexVu UD10 Accessories Part Number Description Ship Weight 009700-001 Magnetic Tool <1 lb (0.45 kg) 014019-001 Gas Inspector 11 CD <1 lb (0.45 kg) 014020-001 W6300G1006 Gas Inspector 11 Kit (includes CD) <1 lb (0.45 kg) 102988-002 Plug, 5.0mm, 6 Position - P2 <1 lb (0.45 kg) 102988-026 Plug, 5.0mm, 3 Position - P1 (J10, CGS) <1 lb (0.45 kg) 102988-028 Plug, 5.0mm, 5 Position - (J3, CGS) <1 lb (0.45 kg) 103726-002 Plug, 3.5mm, 3 Position - J2 <1 lb (0.45 kg) 103726-004 Plug, 3.5mm, 5 Position - J3 <1 lb (0.45 kg) 103726-011 Plug, 3.5mm, 12 Position - J4 <1 lb (0.45 kg) Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* Stop Plug, 3/4" NPT, AL <1 lb (<0.45 kg) 101197-004* Stop Plug, 3/4" NPT, SS <1 lb (<0.45 kg) 101197-005 Stop Plug, M25, AL, IP66 <1 lb (<0.45 kg) 101197-003 Stop Plug, M25, SS, IP66 <1 lb (<0.45 kg) 010816-001* Stop Plug, 20 Pack, 3/4"NPT, AL 1 lb (0.45 kg) 010817-001* Stop Plug, 20 Pack, 3/4"NPT, SS 2 lb (0.9 kg) 010818-001 Stop Plug, 20 Pack, M25, AL,IP66 1.5 lb (0.7 kg) 010819-001 Stop Plug, 20 Pack, M25, SS,IP66 3.25 lb (1.5 kg) 102804-001 Reducer, M25 to M20, AL <1 lb (<0.45 kg) 102804-003 Reducer, M25 to M20, SS <1 lb (<0.45 kg) *NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape. FlexVu® UD10 Universal Display Repair / Upgrade Kit (Technical Bulletin: 76-1046) The UD10 Repair/Upgrade Kit allows field conversion of an existing U9500 Infiniti® Transmitter, Model 505 Transmitter, or Eagle Quantum Premier® Digital Communication Unit (DCU) to a FlexVu® UD10 Universal Display. The existing junction box base, along with the existing conduit and field wiring, can be left in place and do not need to be replaced. FlexVu UD10 Upgrade Kit Model Part Number Material Threads Relay 4-20 RS485 HART EQP/ DCU Emulator Cond. Board FM/ CSA/ ATEX/ IECEx SIL 2 UPGRADE KIT UD10A5M25T2 010970-001 AL M25 X X X UPGRADE KIT UD10A5N25T2 010970-002 AL 3/4 NPT X X X UPGRADE KIT UD10S5M25T2 010970-003 316 SS M25 X X X UPGRADE KIT UD10S5N25T2 010970-004 316 SS 3/4 NPT X X X UPGRADE KIT UD10A5M28W2 010970-005 AL M25 X X UPGRADE KIT UD10A5N28W2 010970-006 AL 3/4 NPT X X UPGRADE KIT UD10S5M28W2 010970-007 316 SS M25 X X UPGRADE KIT UD10S5N28W2 010970-008 316 SS 3/4 NPT X X UPGRADE KIT UD10A5M25W2C 010971-001 AL M25 X CGS X UPGRADE KIT UD10A5N25W2C 010971-002 AL 3/4 NPT X CGS X UPGRADE KIT UD10S5M25W2C 010971-003 316 SS M25 X CGS X UPGRADE KIT UD10S5N25W2C 010971-004 316 SS 3/4 NPT X CGS X UPGRADE KIT UD10A5M28W2C 010971-005 AL M25 X CGS X UPGRADE KIT UD10A5N28W2C 010971-006 AL 3/4 NPT X CGS X UPGRADE KIT UD10S5M28W2C 010971-007 316 SS M25 X CGS X UPGRADE KIT UD10S5N28W2C 010971-008 316 SS 3/4 NPT X CGS X Ship Weight: Aluminum = 3.5 lb (1.6 kg) Stainless Steel = 8.7 lb (3.9 kg) Which other FlexVu UD10 Universal Display part numbers can PE Energy supply?The 46 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description010254-021UD10A5M25T2C DISPLAY, RLY/4-20010254-023UD10S5M25T2C DISPLAY, RLY/4-20010254-024UD10S5N25T2C DISPLAY, RLY/4-20010254-082UD10A5N25B2C DISPLAY,RLY/4-20010254-083UD10S5M25B2C DISPLAY,RLY/4-20010254-084UD10S5N25B2C DISPLAY,RLY/4-20010254-086UD10A5N28B2C DISPLAY,DCU010254-087UD10S5M28B2C DISPLAY,DCU010254-088UD10S5N28B2C DISPLAY,DCU010254-093UD10S5M25SB2C DSPLY,RLY/4-20010254-094UD10S5N25SB2C DSPLY,RLY/4-20010254-095UD10A5M25SB2C DSPLY,RLY/4-20010254-096UD10A5N25SB2C DISPLAY,RLY/4-20010254-853UD10S5M25K2C DISPLAY, RLY/4-20010254-905UD10A5M28R2C DISPLAY, DCU010254-906UD10A5N28R2C DISPLAY, DCU010254-907UD10S5M28R2C DISPLAY, DCU010254-908UD10S5N28R2C DISPLAY, DCU010254-911UD10A5M25SR2C DISPLAY,RLY/4-20010254-912UD10A5N25SR2C DISPLAY,RLY/4-20010254-913UD10S5M25SR2C DISPLAY,RLY/4-20010254-914UD10S5N25SR2C DISPLAY,RLY/4-20010765-081UD10A5M25SB2 DISPLAY, RLY/4-20010765-082UD10A5N25SB2 DISPLAY, RLY/4-20010765-083UD10S5M25SB2 DISPLAY, RLY/4-20010765-084UD10S5N25SB2 DISPLAY, RLY/4-20010765-086UD10A5N28B2 DISPLAY, DCU010765-087UD10S5M28B2 DISPLAY, DCU010765-088UD10S5N28B2 DISPLAY, DCU010765-203UD10S5M25E2 DISPLAY, RLY/4-20010765-300UD10S5M25T2-YO DISPLY,RLY/4-20010765-301UD10S5M25T2-BU DISPLY,RLY/4-20010765-302UD10S5M25T2-G DISPLAY,GREY010765-802UD10A5N25SY2 DISPLAY, RLY/4-20010765-854UD10S5M25SK2 DISPLAY,RLY/4-20010765-857UD10S5M28K2 DISPLAY, DCU010765-901UD10A5M25R2 DISPLAY,RLY/4-20010765-903UD10S5M25R2 DISPLAY,RLY/4-20010765-905UD10A5M28R2 DISPLAY, DCU010765-906UD10A5N28R2 DISPLAY, DCU010765-907UD10S5M28R2 DISPLAY, DCU010765-908UD10S5N28R2 DISPLAY, DCU010765-909UD10A5M25SR2 DISPLAY,RLY/4-20010765-910UD10A5N25SR2 DISPLAY,RLY/4-20010765-911UD10S5M25SR2 DISPLAY,RLY/4-20010765-912UD10S5N25SR2 DISPLAY,RLY/4-20 -

Det-Tronics FlexVu UD10 Universal Display (for Catalytic)
FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications where a gas detector with digital read-out of detected gas levels are required. The FlexVu UD10 Universal Display Unit is designed for use with various Det-Tronics catalytic gas sensor/ transmitters such as Model 505 or CGS. The display unit is designed and approved as a standalone device and performs all the functions of a gas controller. Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to FM 6310/6320, CSA 22.2 #152, ATEX EN60079-29-1, and IEC60079-29-1 Certified as a stand-alone combustible gas controller/detector when used with the CGS sensor Division Approval Ratings: FM and CSA Zone Approval Ratings: FM, CSA, ATEX, and IECEx Eagle Quantum Premier model Non-intrusive menu allows device configuration and calibration without de-classifying the hazardous area Continuously displays gas level, gas type, and units measured Data logger for event time and date stamping Heated and backlit LCD display Relay, modbus, and linear isolated/non-isolated 4-20 mA output with HART, configurable 4-20 mA output loop monitoring IP66 rated SIL2 certified when used with CGS combustible gas sensor FlexVu UD10 Model Matrix - CGS MODEL DESCRIPTION UD10 Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 25 Relay, 4-20mA, RS485, HART 28 EQP / DCU Emulator TYPE APPROVALS B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) TYPE OPTIONAL CONDITIONING BOARD C CGS Typical UD10/CGS Customer Proposal Qty Part Number Description 1 006824-003 Catalytic Combustible Gas Sensor (CGS), M20, CC 1 010254-001 UD10A5M25W2C Universal Display, AL, M25 2 101197-005 Stop plug, M25, AL 1 102804-001 Reducer, M25 to M20, AL Option Qty Part Number Description 1 226365-119 STB1A2MW Sensor Separation Termination Box Accessories Qty Part Number Description 1 225130-001 Methane Gas Calibration Kit, 50% LFL methane 1 226166-001 Spare 103 L gas cylinder, 50% LFL methane FlexVu UD10 Universal Display - CGS - SIL/FM/CSA/ATEX/IECEx Model Part Number Material Threads Relay 4-20 RS485 HART EQP-DCU Emulator Cond. Board SIL/FM/CSA/ ATEX/IECEx FM/CSA/ ATEX/IECEx UD10A5M25W2C 010254-001 AL M25 X CGS X UD10A5N25W2C 010254-002 AL 3/4 NPT X CGS X UD10S5M25W2C 010254-003 316 SS M25 X CGS X UD10S5N25W2C 010254-004 316 SS 3/4 NPT X CGS X UD10A5M25T2C 010254-021 AL M25 X CGS X UD10A5N25T2C 010254-022 AL 3/4 NPT X CGS X UD10S5M25T2C 010254-023 316 SS M25 X CGS X UD10S5N25T2C 010254-024 316 SS 3/4 NPT X CGS X UD10A5M28W2C 010254-005 AL M25 X CGS X UD10A5N28W2C 010254-006 AL 3/4 NPT X CGS X UD10S5M28W2C 010254-007 316 SS M25 X CGS X UD10S5N28W2C 010254-008 316 SS 3/4 NPT X CGS X Ship Weight: Aluminum = 4.2lb (1.9kg) Stainless Steel = 10.5lb (4.8kg) FlexVu UD10 Spare Modules Part Number Description Output Ship Weight 010569-001 UD10 Display Module Relay/4-20mA 1 lb (0.45 kg) 010535-001 UD10 Display Module EQP-DCU 1 lb (0.45 kg) FlexVu UD10 Spare Parts Part Number Description Ship Weight 010973-001 UD10/CGS REPLACEMENT BOARD <1 lb (<0.45 kg) FlexVu UD10 Accessories Part Number Description Ship Weight 009700-001 Magnetic Tool <1 lb (0.45 kg) 014019-001 Gas Inspector 11 CD <1 lb (0.45 kg) 014020-001 W6300G1006 Gas Inspector 11 Kit (includes CD) 1 lb (0.45 kg) 102988-002 Plug, 5.0mm, 6 Position - P2 <1 lb (0.45 kg) 102988-026 Plug, 5.0mm, 3 Position - P1 (J10, CGS) <1 lb (0.45 kg) 102988-028 Plug, 5.0mm, 5 Position - (J3, CGS) <1 lb (0.45 kg) 103726-002 Plug, 3.5mm, 3 Position - J2 <1 lb (0.45 kg) 103726-004 Plug, 3.5mm, 5 Position - J3 <1 lb (0.45 kg) 103726-011 Plug, 3.5mm, 12 Position - J4 <1 lb (0.45 kg) Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* Stop Plug, 3/4" NPT, AL <1 lb (<0.45 kg) 101197-004* Stop Plug, 3/4" NPT, SS <1 lb (<0.45 kg) 101197-005 Stop Plug, M25, AL, IP66 <1 lb (<0.45 kg) 101197-003 Stop Plug, M25, SS, IP66 <1 lb (<0.45 kg) 010816-001* Stop Plug, 20 Pack, 3/4"NPT, AL 1 lb (0.45 kg) 010817-001* Stop Plug, 20 Pack, 3/4"NPT, SS 2 lb (0.9 kg) 010818-001 Stop Plug, 20 Pack, M25, AL,IP66 1.5 lb (0.7 kg) 010819-001 Stop Plug, 20 Pack, M25, SS,IP66 3.25 lb (1.5 kg) 102804-001 Reducer, M25 to M20, AL <1 lb (<0.45 kg) 102804-003 Reducer, M25 to M20, SS <1 lb (<0.45 kg) *NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape. FlexVu® UD10 Universal Display Repair / Upgrade Kit (Technical Bulletin: 76-1046) The UD10 Repair/Upgrade Kit allows field conversion of an existing U9500 Infiniti® Transmitter, Model 505 Transmitter, or Eagle Quantum Premier® Digital Communication Unit (DCU) to a FlexVu® UD10 Universal Display. The existing junction box base, along with the existing conduit and field wiring, can be left in place and do not need to be replaced. FlexVu UD10 Upgrade Kit - CGS Model Part Number Material Threads Relay 4-20 RS485 HART EQPDCU Emulator Cond. Board FM/CSA/ ATEX/ IECEx UPGRADE KIT UD10A5M25W2C 010971-001 AL M25 X CGS X UPGRADE KIT UD10A5N25W2C 010971-002 AL 3/4 NPT X CGS X UPGRADE KIT UD10S5M25W2C 010971-003 316 SS M25 X CGS X UPGRADE KIT UD10S5N25W2C 010971-004 316 SS 3/4 NPT X CGS X UPGRADE KIT UD10A5M28W2C 010971-005 AL M25 X CGS X UPGRADE KIT UD10A5N28W2C 010971-006 AL 3/4 NPT X CGS X UPGRADE KIT UD10S5M28W2C 010971-007 316 SS M25 X CGS X UPGRADE KIT UD10S5N28W2C 010971-008 316 SS 3/4 NPT X CGS X UPGRADE KIT UD10A5M25T2C 010971-011 AL M25 X UPGRADE KIT UD10A5N25T2C 010971-012 AL 3/4 NPT X UPGRADE KIT UD10S5M25T2C 010971-013 316 SS M25 X UPGRADE KIT UD10S5N25T2C 010971-014 316 SS 3/4 NPT X Ship Weight: Aluminum = 3.5lb (1.6kg) Stainless Steel = 8.7lb (3.9kg) -

Det-Tronics FlexVu UD10 Universal Display (for Infrared)
FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications where a gas detector with digital read-out of detected gas levels are required. The FlexVu UD10 Universal Display Unit is designed for use with various Det-Tronics infrared gas sensor/transmitters such as PIRECL, PIR9400, PIRDUCT, or LS2000. The display unit is designed and approved as a stand-alone controller when connected to a certified gas detector and performs all the functions of a gas controller. Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to FM 6310/6320, CSA 22.2 #152, ATEX EN60079-29-1 Division Approval Ratings: FM and CSA Zone Approval Ratings: FM, CSA, ATEX, and IECEx Eagle Quantum Premier model Universal design supports a variety of Det-Tronics sensors/detectors Non-intrusive menu allows device configuration and calibration without de-classifying the hazardous area Continuously displays gas level, gas type, and units measured Data logger for event time and date stamping Heated and backlit display Relay, modbus, and linear isolated/non-isolated 4-20 mA output with HART, configurable 4-20 mA output loop monitoring FDT/DTM capable IP66 rated FlexVu UD10 Model Matrix MODEL DESCRIPTION UD10 Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 25 Relay, 4-20mA, RS485, HART 28 EQP / DCU Emulator TYPE APPROVALS* B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) * Type Approvals can use one or more letters to designate the approvals of the product. FlexVu UD10 Universal Display - Infrared - FM/CSA/ATEX/IECEx Model Part Number Material Threads Relay 4-20 RS485 HART EQP DCU Emulator SIL 2 UD10A5M25T2 010765-001 AL M25 X X UD10A5N25T2 010765-002 AL 3/4 NPT X X UD10S5M25T2 010765-003 316 SS M25 X X UD10S5N25T2 010765-004 316 SS 3/4 NPT X X UD10A5M28W2 010765-005 AL M25 X UD10A5N28W2 010765-006 AL 3/4 NPT X UD10S5M28W2 010765-007 316 SS M25 X UD10S5N28W2 010765-008 316 SS 3/4 NPT X Ship Weight: Aluminum = 4.2lb (1.9kg) Stainless Steel = 10.5lb (4.8kg) FlexVu UD10 Spare Modules Part Number Description Output Ship Weight 010569-001 UD10 Display Module Relay/4-20mA 1 lb (0.45 kg) 010535-001 UD10 Display Module EQP-DCU 1 lb (0.45 kg) FlexVu UD10 Miscellaneous Spare Parts Part Number Description Ship Weight 010973-001 UD10/CGS REPLACEMENT BOARD <1 lb (<0.45 kg) 011919-001 UD10/NTMOS REPLACEMENT BOARD <1 lb (<0.45 kg) FlexVu UD10 Accessories Part Number Description Ship Weight 009700-001 Magnetic Tool <1 lb (0.45 kg) 014019-001 Gas Inspector 11 CD <1 lb (0.45 kg) 014020-001 W6300G1006 Gas Inspector 11 Kit (includes CD) 1 lb (0.45 kg) 102988-002 Plug, 5.0mm, 6 Position - P2 <1 lb (0.45 kg) 102988-026 Plug, 5.0mm, 3 Position - P1 (J10, CGS) <1 lb (0.45 kg) 102988-028 Plug, 5.0mm, 5 Position - (J3, CGS) <1 lb (0.45 kg) 103726-002 Plug, 3.5mm, 3 Position - J2 <1 lb (0.45 kg) 103726-004 Plug, 3.5mm, 5 Position - J3 <1 lb (0.45 kg) 103726-011 Plug, 3.5mm, 12 Position - J4 <1 lb (0.45 kg) Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* Stop Plug, 3/4" NPT, AL <1 lb (<0.45 kg) 101197-004* Stop Plug, 3/4" NPT, SS <1 lb (<0.45 kg) 101197-005 Stop Plug, M25, AL, IP66 <1 lb (<0.45 kg) 101197-003 Stop Plug, M25, SS, IP66 <1 lb (<0.45 kg) 010816-001* Stop Plug, 20 Pack, 3/4"NPT, AL 1 lb (0.45 kg) 010817-001* Stop Plug, 20 Pack, 3/4"NPT, SS 2 lb (0.9 kg) 010818-001 Stop Plug, 20 Pack, M25, AL,IP66 1.5 lb (0.7 kg) 010819-001 Stop Plug, 20 Pack, M25, SS,IP66 3.25 lb (1.5 kg) 102804-001 Reducer, M25 to M20, AL <1 lb (<0.45 kg) 102804-003 Reducer, M25 to M20, SS <1 lb (<0.45 kg) *NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape. FlexVu® UD10 Universal Display Repair / Upgrade Kit (Technical Bulletin: 76-1046) The UD10 Repair/Upgrade Kit allows field conversion of an existing U9500 Infiniti® Transmitter, Model 505 Transmitter, or Eagle Quantum Premier Digital Communication Unit (DCU) to a FlexVu® UD10 Universal Display. The existing junction box base, along with the existing conduit and field wiring, can be left in place and do not need to be replaced. FlexVu UD10 Upgrade Kit - Infrared Model Part Number Material Threads Relay 4-20 RS485 HART EQP DCU Emulator FM/CSA/ATEX/IECEx SIL 2 UPGRADE KIT UD10A5M25T2 010970-001 AL M25 X X X UPGRADE KIT UD10A5N25T2 010970-002 AL 3/4 NPT X X X UPGRADE KIT UD10S5M25T2 010970-003 316 SS M25 X X X UPGRADE KIT UD10S5N25T2 010970-004 316 SS 3/4 NPT X X X UPGRADE KIT UD10A5M28W2 010970-005 AL M25 X X UPGRADE KIT UD10A5N28W2 010970-006 AL 3/4 NPT X X UPGRADE KIT UD10S5M28W2 010970-007 316 SS M25 X X UPGRADE KIT UD10S5N28W2 010970-008 316 SS 3/4 NPT X X Ship Weight: Aluminum = 3.5lb (1.6kg) Stainless Steel = 8.7lb (3.9kg) -

Det-Tronics FlexVu UD20 Universal Display
FlexVu UD20 Universal Display (Spec Sheet: 90-1201 - Explosion-proof Model, 90-1205 - Intrinsically Safe Model) supports the GT3000 Series toxic gas detectors. Compliance to ANSI/ISA-60079-11 and ISA-92.0.01 Part 1 performance standard Division Approval Ratings: FM and CSA Zone Approval Ratings: FM, CSA, ATEX, and IECEx LCD display Non-intrusive automatic calibration Non-intrusive menu system Linear 4-20 mA output with HART Explosion-proof design IP66 rated 2 wire loop powered Certified Non-Interfering with GT3000 SIL model FlexVu UD20 Model Matrix MODEL DESCRIPTION UD20 Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 26 Pass-Through 4-20mA, HART TYPE APPROVALS* B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) 4 Ex ia (intrinsically safe) FlexVu UD20 Universal Display - FM/CSA/ATEX/IECEx Model Part Number Material Threads Pass-Through 4-20 HART Ex d Ex ia FM/CSA/ ATEX/IECEx UD20A5M26W2 009791-001 AL M25 X X X UD20A5N26W2 009791-002 AL 3/4 NPT X X X UD20S5M26W2 009791-003 316 SS M25 X X X UD20S5N26W2 009791-004 316 SS 3/4 NPT X X X UD20A5M26W4 009791-005* AL M25 X X X UD20A5N26W4 009791-006* AL 3/4 NPT X X X UD20S5M26W4 009791-007* SS M25 X X X UD20S5N26W4 009791-008* SS 3/4 NPT X X X Ship Weight: Aluminum = 4.2lb (1.9kg) Stainless Steel = 10.5lb (4.8kg) FlexVu UD20 Spares Part Number Description Pass-Through 4-20 / HART Ship Weight 009793-002 UD20 Display Module X 1 lb (0.45 kg) FlexVu UD20 Accessories Part Number Description Ship Weight 009700-001 Magnetic Tool <1 lb (0.45 kg) 010253-001 Kit, 250Ω Terminating Resistor <1 lb (0.45 kg) Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* Stop Plug, 3/4" NPT, AL <1 lb (<0.45 kg) 101197-004* Stop Plug, 3/4" NPT, SS <1 lb (<0.45 kg) 101197-005 Stop Plug, M25, AL, IP66 <1 lb (<0.45 kg) 101197-003 Stop Plug, M25, SS, IP66 <1 lb (<0.45 kg) 010816-001* Stop Plug, 20 Pack, 3/4"NPT, AL 1 lb (0.45 kg) 010817-001* Stop Plug, 20 Pack, 3/4"NPT, SS 2 lb (0.9 kg) 010818-001 Stop Plug, 20 Pack, M25, AL,IP66 1.5 lb (0.7 kg) 010819-001 Stop Plug, 20 Pack, M25, SS,IP66 3.25 lb (1.5 kg) 102804-001 Reducer, M25 to M20, AL <1 lb (<0.45 kg) 102804-003 Reducer, M25 to M20, SS <1 lb (<0.45 kg) *NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape. Which other FlexVu UD20 Universal Display part numbers can PE Energy supply?The 8 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description009791-081UD20A5M26B2 DISPLAY, BRAZIL009791-082UD20A5N26B2 DISPLAY, BRAZIL009791-083UD20S5M26B2 DISPLAY, BRAZIL009791-084UD20S5N26B2 DISPLAY, BRAZIL009791-901UD20A5M26R2 DISPLAY,RUSSIAN009791-902UD20A5N26R2 DISPLAY,RUSSIAN009791-903UD20S5M26R2 DISPLAY,RUSSIAN009791-904UD20S5N26R2 DISPLAY,RUSSIAN -

Det-Tronics GT3000 Certified Calibration Kits
GT3000 Certified Calibration Kits (Manual: 95-8643) consists of a sturdy carrying case containing: Configuration 1 GT3000 calibration kit with two cylinders of calibration gas Two cylinders of Class 2.2 non-flammable, non-toxic compressed gas A 1 liter/minute regulator and pressure indicator 3-foot tube GT3000 Calibration Cup Configuration 2 GT3000 calibration kit with one cylinder of calibration gas and one humidifier One cylinder of Class 2.2 non-flammable, non-toxic compressed gas One humidifier A 1 liter/minute regulator and pressure indicator 3-foot tube GT3000 Calibration Cup GT3000 Calibration Gas Kits Part Number Concentration Gas Balance Cylinders Humidifier Ship Weight 010274-001 10 ppm Hydrogen Sulfide Nitrogen 2 11.5 lb (5.23 kg) 010274-002 25 ppm Hydrogen Sulfide Nitrogen 2 11.5 lb (5.23 kg) 010274-003* 50 ppm Hydrogen Sulfide Nitrogen 2 11.5 lb (5.23 kg) 010274-004 5 ppm Chlorine Nitrogen 2 11.5 lb (5.23 kg) 010274-005 50 ppm Ammonia Nitrogen 2 11.5 lb (5.23 kg) 010274-006 250 ppm Ammonia Nitrogen 2 11.5 lb (5.23 kg) 010274-008 500 ppm Hydrogen Air 2 11.5 lb (5.23 kg) 010274-009 20.90% Oxygen Nitrogen 2 11.5 lb (5.23 kg) 010274-010 50 ppm Carbon Monoxide Air 2 11.5 lb (5.23 kg) 010274-011 250 ppm Carbon Monoxide Air 2 11.5 lb (5.23 kg) 010274-013 10 ppm Sulfur Dioxide Nitrogen 2 11.5 lb (5.23 kg) 010274-014 50 ppm Sulfur Dioxide Nitrogen 2 11.5 lb (5.23 kg) 010274-016 10 ppm Nitrogen Dioxide Air 2 11.5 lb (5.23 kg) 014059-001 5 ppm Chlorine Nitrogen 1 1 11.5 lb (5.23 kg) *Do not use for NTMOS. GT3000 Calibration Gas Kit Replacement Cylinders Part Number Concentration Gas Balance Cylinders 227117-011 10 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-012 25 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-001* 50 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-006 5 ppm Chlorine Nitrogen 1.5 lb (0.7 kg) 227117-013 50 ppm Ammonia Nitrogen 1.5 lb (0.7 kg) 227117-019 250 ppm Ammonia Nitrogen 1.5 lb (0.7 kg) 227117-018 500 ppm Hydrogen Air 1.5 lb (0.7 kg) 226166-006 20.90% Oxygen Nitrogen 1.5 lb (0.7 kg) 227117-003 50 ppm Carbon Monoxide Air 1.5 lb (0.7 kg) 227117-004 250 ppm Carbon Monoxide Air 1.5 lb (0.7 kg) 227117-016 10 ppm Sulfur Dioxide Nitrogen 1.5 lb (0.7 kg) 227117-008 50 ppm Sulfur Dioxide Nitrogen 1.5 lb (0.7 kg) 227117-010 10 ppm Nitrogen Dioxide Air 1.5 lb (0.7 kg) *Do not use for NTMOS. GT3000 Calibration Kit Replacement Parts Part Number Description Ship Weight 009700-001 Magnetic Tool <1 lb (0.45 kg) 009737-001 GT3000 Calibration Cup 8 oz (0.23 kg) 107427-059 O-ring for Calibration Cup <1 lb (0.45 kg) 010780-003 GT3000 Remote Calibration Adaptor <1 lb (0.45 kg) 101678-007 Tubing, 3 ft. 8 oz (0.23 kg) 101678-013 Tubing, 100 ft. spool 8 oz (0.23 kg) 162552-001 Regulator, 1 LPM 8 oz (0.23 kg) 162553-001 Carrying Case 8 oz (0.23 kg) -

Det-Tronics GTS Toxic Gas Sensor Module (GT3000 Series)
GTS Toxic Gas Sensor Module (Spec Sheet: 90-1199) housings are incorporated into the GTX toxic gas transmitter. The electrochemical cell is embedded in the module. Performance approved models NEW! Plus (+) series sensors with dual reservoir technology and extended temperature range Sensor modules are available in a variety of gas types and concentration ranges Hot-swappable capabilities with the GTX transmitter Easy install and removal with the GTX transmitter Intrinsically safe (IS) design SIL models available for Hydrogen Sulfide and Oxygen sensors DNV models available with Hydrogen Sulfide sensors Suitable for outdoor applications requiring IP66 rating Electrochemical sensor cell for increased accuracy, stability, and reliability Highly specific response reduces the chance of false alarms resulting from the presence of other gases Temperature compensated to ensure consistent performance over entire operating temperature range Hydrophobic filter easily replaced without opening the device or use of tools EMI/RFI hardened Event and calibration logs are stored in non-volatile memory and are accessible using a UD10/UD20, HART device, or AMS software. FDT/DTM capable Real-time clock with battery back-up GTS Model Matrix MODEL DESCRIPTION GTS Toxic Gas Sensor Module TYPE GAS / RANGE H2S+ Hydrogen Sulfide (certified SIL 2 capable) 20P 0 - 20 PPM 50P 0 - 50 PPM 100P 0 - 100 PPM CL2 Chlorine 10P 0 - 10 PPM NH3 Ammonia 100P 0 - 100 PPM 500P 0 - 500 PPM H2 Hydrogen 1000P 0 - 1000 PPM O2 Oxygen (certified SIL 2 capable) 25V 0 - 25 % by Vol CO Carbon Monoxide 100P 0 - 100 PPM 500P 0 - 500 PPM SO2+ Sulfur Dioxide 20P 0 - 20 PPM 100P 0 - 100 PPM NO2 Nitrogen Dioxide 20P 0 - 20 PPM TYPE SAFETY INTEGRITY LEVEL S SIL 2 N NON-SIL TYPE LABEL C CHINESE E ENGLISH K KAZAKH P PORTUGUESE (Brazil) R RUSSIA TYPE HOUSING S STANDARD E ENHANCED SHIELDING GTS Toxic Gas Sensor Module - ENGLISH Model Number Part Number Toxic Gas ppm Range % by Volume GTSH2S+20PSEE1 009471-3411 H2S 0-20 GTSH2S+50PSEE1 009471-3421 H2S 0-50 GTSH2S+100PSES2 009471-3432 H2S 0-100 GTSH2S+100PSEE1 009471-3441 H2S 0-100 GTSCL210PNES3 009471-3043 Cl2 0-10 GTSNH3100PNES2 009471-3052 NH3 0-100 GTSNH3500PNES3 009471-3063 NH3 0-500 GTSH21000PNES3 009471-3083 H2 0-1000 GTSO225VSES3 009471-3093 O2 0-25% GTSCO100PNES2 009471-3102 CO 0-100 GTSCO500PNES2 009471-3112 CO 0-500 GTSSO2+20PNES3 009471-3133 SO2 0-20 GTSSO2+100PNES3 009471-3143 SO2 0-100 GTSNO220PNES3 009471-3163 NO2 0-20 NOTE: Refer to the GT3000 Instruction Manual 95-8616 for details on performance approvals. NOTES: GTS Approval when paired with approriate GTX approval type GTX approval types 1 DNV/FM/CSA/IECEx N 2 FM/CSA/IECEx N 3 CSA/IECEx N Sensor Comparison Gas Range Response Time1 Accuracy of Reading (Whichever is Greater) Operating Temperature Range Zero Drift Performance Approved Standard Hydrogen Sulfide (H2S) 0-20 ppm T20 = ≤7 Sec. T50 = ≤10 Sec. T90 = ≤16 Sec. ±2 ppm or ±10% of Reading –40°C to +50°C ± 1 ppm/Mo. ISA 92.00.014 Hydrogen Sulfide (H2S) 0-50 ppm T20 = ≤4 Sec. T50 = ≤7 Sec. T90 = ≤16 Sec. ±2 ppm or ±10% of Reading –40°C to +50°C ± 1 ppm/Mo. ISA 92.00.014 Hydrogen Sulfide (H2S) 0-100 ppm T20 = ≤5 Sec. T50 = ≤8 Sec. T90 = ≤21 Sec. ±2 ppm or ±10% of Reading –40°C to +50°C ± 2 ppm/Mo. ISA 92.00.014 Hydrogen Sulfide (H2S+) 0-20 ppm T20 = ≤10 Sec. T50 = ≤13 Sec. T90 = ≤23 Sec. ±2 ppm or ±10% of Reading –40°C to +55°C ± 1 ppm/Mo. ISA 92.00.014 Hydrogen Sulfide (H2S+) 0-50 ppm T20 = ≤6 Sec. T50 = ≤9 Sec. T90 = ≤15 Sec. ±2 ppm or ±10% of Reading –40°C to +55°C ± 1 ppm/Mo. ISA 92.00.014 Hydrogen Sulfide (H2S+) 0-100 ppm T20 = ≤6 Sec. T50 = ≤8 Sec. T90 = ≤15 Sec. ±2 ppm or ±10% of Reading –40°C to +55°C ± 2 ppm/Mo. ISA 92.00.014 Ammonia (NH3) 0-100 ppm2 T50 = 24 Sec. T90 = 65 Sec. ±4 ppm or ±10% of Reading –20°C to +40°C ± 2 ppm/Mo. FM63404 Ammonia (NH3) 0-500 ppm2 T50 = 30 Sec. T90 = 120 Sec. ±4 ppm or ±10% of Reading –20°C to +40°C ± 10 ppm/Mo. Det-Tronics Verified Oxygen (O2) 0-25% V/V3 T20 = 7 Sec. T90 = 30 Sec. < 0.5% V/V –20°C to +50°C < 2 %/Mo. Det-Tronics Verified Carbon Monoxide (CO) 0-100 ppm T50 = 15 Sec. T90 = 40 Sec. ±5 ppm or ±10% of Reading –20°C to +50°C ± 2 ppm/Mo. ISA 92.00.014 Carbon Monoxide (CO) 0-500 ppm T50 = 12 Sec. T90 = 25 Sec. ±5 ppm or ±10% of Reading –40°C to +50°C ± 9 ppm/Mo. ISA 92.00.014 Sulfur Dioxide (SO2+) 0-20 ppm T50 = 12 Sec. T90 = 30 Sec. ±0.6 ppm or ±10% of Reading –40°C to +55°C ± 0.4 ppm/Mo. Det-Tronics Verified Sulfur Dioxide (SO2+) 0-100 ppm T50 = 15 Sec. T90 = 35 Sec. ±0.6 ppm or ±10% of Reading –20°C to +55°C ± 0.4 ppm/Mo. Det-Tronics Verified Chlorine (Cl2) 0-10 ppm T50 = ≤14 Sec. T90 = ≤34 Sec. ±0.6 ppm or ±10% of Reading –20°C to +50°C < 0.2 ppm/Mo. Det-Tronics Verified Hydrogen (H2) 0-1000 ppm T50 = 8 Sec. T90 = 60 Sec. ±50 ppm or ±10% of Reading –20°C to +40°C ± 20 ppm/Mo. Det-Tronics Verified Nitrogen Dioxide (NO2) 0-20 ppm T50 = 7 Sec. T90 = 31 Sec. ±2 ppm or ±10% of Reading –20°C to +40°C ± 0.1 ppm/Mo. Det-Tronics VerifiedZ 1 Time to reach percentage of final reading when gas concentration equal to full scale is applied to sensor. 2 Background concentrations of ammonia may shorten lifetime of sensor. 3 Sensor approved for oxygen depletion (< 21% V/V) only. 4 Factory Mutual Performance Approved. Model Q912 Duct Mount Enclosure The Model Q912 Duct Mount Enclosure provides reliable detection of toxic gases within air-handling ductwork. The device mounts directly to the ductwork, and uses a cross-sectional inlet and outlet sampling tube arrangement that allows large volume air sampling. The Q912 is compatible with the entire Det-Tronics GT3000 family of gas detectors, and is suitable for hazardous industrial and commercial applications. Stainless steel NEMA 4X enclosure Stainless steel sample inlet tube spans the duct’s cross section 1, 3, 6, 10 or 13 ft (0.3, 0.9, 1.8, 3.1 or 4 meter) inlet tube options 1 ft (0.3 m) outlet tube returns the sample Requires a 600–4000 fpm velocity Designed for flat surface mounting only Model Q912 Toxic Duct Mount Enclosure Part Number Description* Detector Conduit Inlet Tube Length 012513-001 Q912 Duct Mount M25, 1ft inlet M25 1 ft (0.3m) 012513-003 Q912 Duct Mount M25, 3ft inlet M25 3 ft (0.9m) 012513-006 Q912 Duct Mount M25, 6ft inlet M25 6 ft (1.8m) 012513-010 Q912 Duct Mount M25, 10ft inlet M25 10 ft (3.1m) 012513-013 Q912 Duct Mount M25, 13ft inlet M25 13 ft (4m) 012514-001 Q912 Duct Mount 3/4", 1ft inlet 3/4" 1 ft (0.3m) 012514-003 Q912 Duct Mount 3/4", 3ft inlet 3/4" 3 ft (0.9m) 012514-006 Q912 Duct Mount 3/4", 6ft inlet 3/4" 6 ft (1.8m) 012514-010 Q912 Duct Mount 3/4", 10ft inlet 3/4" 10 ft (3.1m) 012514-013 Q912 Duct Mount 3/4", 13ft inlet 3/4" 13 ft (4m) 012363-001 Spare Diffuser Insert *1 ft outlet tube included with each duct mount. Model Q912 Spare Parts Part Number Description* Length Material Ship Weight 000214-281 Inlet Tube 1 ft (0.3 m) 316 SS 8 oz (0.23 kg) 000214-282 Inlet Tube 3 ft (0.9 m) 316 SS 1 lb (0.45 kg) 000214-283 Inlet Tube 6 ft (1.8 m) 316 SS 3 lb (1.35 kg) 000214-284 Inlet Tube 10 ft (3.1 m) 316 SS 6 lb (2.4 kg) 000214-285 Inlet Tube 13 ft (4 m) 316 SS 9 lb (4.0 kg) 000214-280 Outlet Tube 1 ft (0.3 m) 316 SS 8 oz (0.23 kg) 102359-001 Stopper Plug N/A Rubber <1 lb (<0.45 kg) Which other GTS Toxic Gas Sensor Module (GT3000 Series) part numbers can PE Energy supply?The 38 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description000601-012GTS SENSOR SIMULATOR009471-509GTSO225VTD,SENSOR MOD,O2,0-25009471-601GTSH2S+20PSPE,H2S,0-20009471-602GTSH2S+50PSPE,H2S,0-50009471-603GTSH2S+100PSPE,H2S,0-100009471-604GTSH2S+100PSPS,H2S,0-100009471-605GTSCL210PNPS,CL2,0-10009471-606GTSNH3100PNPS,NH3,0-100009471-607GTSNH3500PNPS,NH3,0-500009471-608GTSO225VSPS,O2,0-25%009471-609GTSCO100PNPS,CO,0-100009471-610GTSCO500PNPS,CO,0-500009471-611GTSH21000PNPS,SENSOR,H2,0-1000009471-812GTSH2S+20PSCE,H2S,0-20009471-813GTSH2S+50PSCE,H2S,0.50009471-814GTSH2S+100PSCE,H2S,0-100009471-815GTSH2S+100PSCS,H2S,0-100009471-816GTSO225VSCS,O2,0-25%009471-817GTSCO100PNCS,CO,0-100009471-818GTSCO500PNCS,CO,0-500009471-819GTSSO2+20PNCS,SO2,0-20009471-820GTSSO2+100PNCS,SO2,0-100009471-859GTSO225VK,SENSOR MOD,O2,0-25%009471-860GTSH2S+20PSKE,H2S,0-20009471-861GTSH2S+50PSKE,H2S,0-50009471-862GTSH2S+100PSKE,H2S,0-100009471-863GTSH2S+100PSKS,H2S,0-100009471-864GTSH21000PNKS,H2,0-1000009471-909GTSO225VR, SENSOR, O2, 0-25%009471-944GTSH2S+20PSRE,H2S,0-20009471-945GTSH2S+50PSRE,H2S,0-50009471-946GTSH2S+100PSRE,H2S,0-100009471-947GTSH2S+100PSRS,H2S,0-100009471-949GTSNH3100PNRS,NH3,0-100009471-951GTSCO100PNRS,CO,0-100009471-952GTSCO500PNRS,CO,0-500009471-953GTSH21000PNRS,H2,0-1000009737-001GTS CALIBRATION CUP ASSEMBLY -

Det-Tronics GTX Toxic Gas Transmitter (GT3000 Series)
GTX Toxic Gas Transmitter (Spec Sheet: 90-1199). Stainless steel, toxic gas transmitter that provides an accurate measurement of toxic gasses. 316 Stainless Steel Approved as a stand-alone device when combined with a GTS toxic gas sensor 4-20 mA output with HART Intrinsically safe (IS) or Explosion-proof design IP66 rated SIL 2 capable sensors are Hydrogen Sulfide and Oxygen Performance approved and verified Self-contained transmitter circuitry Event and calibration logs are stored in non-volatile memory and are accessible using a UD10/UD20, HART device, AMS software, or Gas Inspector. FDT/DTM capable Real-time clock with battery back-up Magnetic switch and LEDs for user interface 2-wire loop powered GTX Model Matrix MODEL DESCRIPTION GTX Toxic Gas Transmitter TYPE MATERIAL S Stainless Steel (316) TYPE THREAD TYPE N 3/4" NPT M Metric M25 TYPE OUTPUTS 26 4-20 mA w/HART (3.5 mA fault) 29 4-20 mA w/HART (2.45 mA fault) TYPE APPROVALS B INMETRO (Brazil) K KAZAKH N FM/CSA/IEXEx R RUSSIA Y CHINA TYPE CLASSIFICATION (Division/Zone) 4 Intrinsically Safe 5 Explosion-proof GTX Toxic Gas Transmitter (for use with FlexVu models UD10/20, and GDTB) Model Number Part Number Threads IS Ex Proof Approvals GTXSN26N4 009480-321 3/4 NPT X FM/CSA/IECEx GTXSM26N4 009480-322 M25 X FM/CSA/IECEx GTXSN26N5 009480-323 3/4 NPT X FM/CSA/IECEx GTXSM26N5 009480-324 M25 X FM/CSA/IECEx GTXSN26B5 009480-305 3/4 NPT X INMETRO GTXSM26B5 009480-306 M25 X INMETRO GTXSM26SK5 009480-866 M25 X KAZAKH GTXSN26R4 009480-905 3/4 NPT X RUSSIA GTXSM26R4 009480-906 M25 X RUSSIA GTXSN26R5 009480-907 3/4 NPT X RUSSIA GTXSM26R5 009480-908 M25 X RUSSIA GTXSN26Y4 009480-805 3/4 NPT X CHINA GTXSM26Y4 009480-806 M25 X CHINA Ship Weight: <1lb (<0.45kg) NOTE: Refer to the GT3000 Instruction Manual 95-8616 for details on performance approvals. GTX Toxic Gas Transmitter (for use with U9500) Model Number Part Number Threads IS Ex Proof Approvals GTXSN29N4 009480-325 3/4 NPT X FM/CSA/IECEx GTXSM29N4 009480-326 M25 X FM/CSA/IECEx GTXSN29N5 009480-327 3/4 NPT X FM/CSA/IECEx GTXSM29N5 009480-328 M25 X FM/CSA/IECEx GTXSN29B5 009480-307 3/4 NPT X INMETRO GTXSM29B5 009480-308 M25 X INMETRO Ship Weight: <1lb (<0.45kg) NOTE: Refer to the GT3000 Instruction Manual 95-8616 for details on performance approvals. Which other GTX Toxic Gas Transmitter (GT3000 Series) part numbers can PE Energy supply?The 1 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description009480-902GTXSM26R4 TX,M25,IS,RUSSIAN -

Det-Tronics Model 505 Combustible Transmitter
(Includes junction box, sensor ordered separately) Model 505 Combustible Transmitter (Spec Sheet: 90-1114). Designed for use with CGS sensor, the 505 provides an analog signal output representing detected gas concentration. The 505 is always used with a gas controller. Compliance to ANSI/ISA-12.13.01-2000 performance standards when connected to a standalone gas controller Performance certified to ATEX EN60079-29-1 4-20 mA output Sensor sensitivity check function One person calibration Includes a variety of j-box options Model 505 Retrofit Kits are available to upgrade an existing K-Series or Model 500 transmitter to the Model 505 transmitter using existing junction boxes and field wiring. The kit consists of: A transmitter board A label with calibration instructions for the junction box cover Instruction manual Junction box not included. Model 505 Model Matrix MODEL DESCRIPTION 505 Catalytic Combustible Gas Transmitter TYPE MATERIAL A Aluminum S Stainless Steel TYPE CONDUIT ENTRIES AND ORIENTATION 2 2-ports, ST-straight-through configuration (180 degree orientation) 3 2-ports, L-configuration (90 degree orientation) 4 3-ports, T-configuration 5 5-ports TYPE THREAD TYPE A 3/4" NPT C M20/M25 TYPE OUTPUT 2 4-20 mA TYPE SIGNAL LOOP IMPEDANCE A 0-125 ohms (replaces K series) B 100-500 ohms (replaces Model 500) TYPE CLASSIFICATION 1 Explosion-proof TYPE APPROVALS W FM/CSA/ATEX/IECEx Model 505 Combustible Transmitter and Junction Box Model Part Number Replaces Material Conduit Entry* Ports† Ohm Output FM/CSA/ ATEX/ IECEx 505A2A2A1W 006748-001 226585-001, 226555-113 AL 3/4 NPT 2 (ST) 125 X 505A3A2A1W 006748-002 226585-001, 226555-101 AL 3/4 NPT 2 (L) 125 X 505A2C2A1W 006748-003 AL M20 2 (ST) 125 X 505A3C2A1W 006748-004 226585-001, 226555-107 AL M20/M25 2 (L) 125 X 505A2A2B1W 006748-005 226673-001, 226555-113 AL 3/4 NPT 2 (ST) 500 X 505A3A2B1W 006748-006 226673-001, 226555-101 AL 3/4 NPT 2 (L) 500 X 505A2C2B1W 006748-007 AL M20 2 (ST) 500 X 505A3C2B1W 006748-008 226673-001, 226555-107 AL M20/M25 2 (L) 500 X 505S3A2A1W 006748-009 226585-001, 226555-111 SS 3/4 NPT 2 (L) 125 X 505S3C2A1W 006748-010 226585-001, 226555-112 SS M20 2 (L) 125 X 505S3A2B1W 006748-011 226673-001, 226555-111 SS 3/4 NPT 2 (L) 500 X 505S3C2B1W 006748-012 226673-001, 226555-112 SS M20 2 (L) 500 X 505A4A2A1W 006748-013 AL 3/4 NPT 3 (T) 125 X 505A4C2A1W 006748-014 AL M20 3 (T) 125 X Ship Weight: Aluminum = 3.8 lb (1.7 kg) Stainless Steel = 8.7 lb (4 kg) *If 2 numbers are listed, the first number is sensor entry, and second number is for field cable entry(ies) †"L" designates 90 degree conduit entry orientation. "ST" designates straight-thru or 180 degree orientation Model 505 Spare Parts Part Number Description Output Load Ship Weight 006817-001 505 pc board 125 ohms 8 oz (0.23 kg) 006817-002 505 pc board 500 ohms 8 oz (0.23 kg) 102883-001 505 Sensor Wiring Terminal Block n/a 8 oz (0.23 kg) Model 505 Retrofit Kits Part Number Description Output Load 006818-001 K series-125 ohms 8 oz (0.23 kg) 006818-002 500 model-500 ohms 8 oz (0.23 kg) -

Det-Tronics Model PIRTB PointWatch Termination Box
Use for stand-alone PointWatch Model PIR9400 Required for remote separation from U9500H transmitter Use with PIRECL Eclipse or PIR9400 when remote calibration initiation is required Magnetic reed switch calibration and LED gives calibration feedback Tall cover boxes with window enable one person, non-intrusive calibration Short cover boxes without window require two people to accomplish non-intrusive calibration PIRTB Junction Box Model Matrix (for use with PIRECL and PIR9400) MODEL DESCRIPTION PIRTB PointWatch Termination Box TYPE MATERIAL A Aluminum S Stainless Steel TYPE # OF OPEN PORTS 2 2 Port 5 5 Port TYPE THREAD TYPE L Metric M25 N 3/4" NPT M Metric M20/M25 TYPE APPROVALS B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) W FM/CSA/ATEX/IECEx TYPE COVER TYPE 1 Short without window 3 Tall with window TYPE CABLE ENTRIES I Ports 2 and 6 open (aluminum only) L Ports 2 and 4 open V Ports 2 thru 6 open Model PIRTB PointWatch Termination Boxes - short cover Model Part Number Material Threads FM/CSA/ATEX/IECEx VNIIFTRI Ports PIRTBA2NW1L 006414-001 AL 3/4 NPT X 2 PIRTBA2MW1L 006414-002 AL M20/25 X 2 PIRTBS2NW1L 006414-007 SS 3/4 NPT X 2 PIRTBA2NW1I 006414-009 AL 3/4 NPT X 2 PIRTBA5NW1V 006414-016 AL 3/4 NPT X 5 PIRTBS5NW1V 006414-017 SS 3/4 NPT X 5 PIRTBA5LW1V 006414-018 AL M25 X 5 PIRTBS5LW1V 006414-019 SS M25 X 5 PIRTBA2MR1L 006414-902 AL M20/25 X 2 Ship Weight: Aluminum = 2 lb (0.95 kg) Stainless Steel = 9 lb (4.1 kg) Model PIRTB PointWatch Termination Boxes - tall cover Model Part Number Material Threads FM/CSA/ATEX/IECEx INMETRO VNIIFTRI Ports PIRTBA2NW3L 006414-003 AL 3/4 NPT X 2 PIRTBA2MW3L 006414-004 AL M20/25 X 2 PIRTBS2NW3L 006414-014 SS 3/4 NPT X 2 PIRTBA2NB3L 006414-015 AL 3/4 NPT X 2 PIRTBA5NW3V 006414-020 AL 3/4 NPT X 5 PIRTBS5NW3V 006414-021 SS 3/4 NPT X 5 PIRTBA5LW3V 006414-022 AL M25 X 5 PIRTBS5LW3V 006414-023 SS M25 X 5 PIRTBA2MR3L 006414-904 AL M20/25 X 2 Ship Weight: Aluminum = 2.2 lb (1kg) Stainless Steel = 9.5 lb (4.3 kg) Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* Stop Plug, 3/4" NPT, AL <1 lb (<0.45 kg) 101197-004* Stop Plug, 3/4" NPT, SS <1 lb (<0.45 kg) 101197-005 Stop Plug, M25, AL, IP66 <1 lb (<0.45 kg) 101197-003 Stop Plug, M25, SS, IP66 <1 lb (<0.45 kg) 010816-001* Stop Plug, 20 Pack, 3/4"NPT, AL 1 lb (0.45 kg) 010817-001* Stop Plug, 20 Pack, 3/4"NPT, SS 2 lb (0.9 kg) 010818-001 Stop Plug, 20 Pack, M25, AL,IP66 1.5 lb (0.7 kg) 010819-001 Stop Plug, 20 Pack, M25, SS,IP66 3.25 lb (1.5 kg) 102804-001 Reducer, M25 to M20, AL <1 lb (<0.45 kg) 102804-003 Reducer, M25 to M20, SS <1 lb (<0.45 kg) *NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape. Which other Model PIRTB PointWatch Termination Box part numbers can PE Energy supply?The 5 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description006414-008PIRTBS2KW1L, SS,M20,2L,SHORT006414-010PIRTBS2KW3L, SS,M20,2L,TALL006414-011PIRTBA3NW3T, AL,3/4,3T,TALL006414-012PIRTBA3MW3T, AL,M20/25,3T,TALL006414-310PIRTBS2KW3L-YO, SS,M20,2L,TALL -

Det-Tronics Model STB Sensor Termination Box / Separation Kit
Model STB Sensor Termination Box / Separation Kit includes a junction box, proper connector board required hardware. Enables remote installation of sensor for optimum gas detection while offering easy calibration access to transmitter One sensor separation kit per sensor is required Optional remote calibration cups must be ordered separately (see CGS Accessories) Transmitter Sensor separation wiring terminal block (part number 102883-001) is sold separately Temperature approved models from –55°C to 125°C for process control applications STB Model Matrix MODEL DESCRIPTION STB Sensor Termination Box TYPE COMPATIBILITY 1 CGS for FlexVu Model UD10 or Model 505 Transmitter 2 CGS for U9500A Transmitter or DCUEX 5 12 terminal TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE # OF PORTS, THREAD TYPE 2M 2 PORT, M20/25 at 90 degree orientation 2N 2 PORT, 3/4" NPT at 90 degree orientation 2S 2 PORT, M20 AT 180 degree vertical 2U 2 PORT, 3/4" NPT at 180 degree vertical 2X 2 PORT, M20 at 90 degree orientation 2Y 2 PORT, M25 at 90 degree orientation 3n 3 PORT, 3/4" NPT 3Y 3 PORT, M25 5Y 5 PORT, M25 5N 5 PORT, 3/4" NPT 6Y 6 PORT, M25 6N 6 PORT, 3/4" NPT TYPE APPROVALS R VNIIFTRI (RUSSIA) W FM/CSA/ATEX/IECEx Model STB Sensor Termination Boxes / Separation Kits Model Part Number Use With Material Ports* Threads† FM/CSA/ ATEX/IECEx VNIIFTRI STB1A2MW 226365-119 UD10/Model 505 AL 2 (L) M20/M25 X STB1A2NW 226365-131 UD10/Model 505 AL 2 (L) 3/4 NPT X STB1A2SW 226365-123 UD10/Model 505 AL 2 (ST) M20 X STB1A2UW 226365-137 UD10/Model 505 AL 2 (ST) 3/4 NPT X STB1S2NW 226365-140 UD10/Model 505 SS 2 (L) 3/4 NPT X STB1S2XW 226365-121 UD10/Model 505 SS 2 (L) M20 X N/A 102883-001 Spare terminal block for use with Model 505 (included with STB1) STB2A2MR 226365-927 U9500A/DCUEX AL 2 (L) M20/M25 X STB2A2MW 226365-127 U9500A/DCUEX AL 2 (L) M20/M25 X STB2A2NW 226365-132 U9500A/DCUEX AL 2 (L) 3/4 NPT X S6B2A2UW 226365-136 U9500A/DCUEX AL 2 (ST) 3/4 NPT X STB2A5NW 226365-144 U9500A/DCUEX AL 5 3/4 NPT X STB2S2MW 226365-135 U9500A/DCUEX SS 2 (L) M20/M25 X STB2S2NW 226365-142 U9500A/DCUEX SS 2 (L) 3/4 NPT X N/A 006470-001 Harness for use with CGS and U9500A (included with STB2) STB5A6YR 226365-928 12 terminal AL 6 M25 X STB5S5YR 226365-929 12 terminal SS 5 M25 X STB5A2NW 226365-520 12 terminal AL 2 (L) 3/4/NPT X STB5A2YW 226365-510 12 terminal AL 2 (L) M25 X STB5A3NW 226365-521 12 terminal AL 3 (T) 3/4 NPT X STB5A3YW 226365-511 12 terminal AL 3 (T) M25 X STB5A5NW 226365-522 12 terminal AL 5 3/4 NPT X STB5A5YW 226365-512 12 terminal AL 5 M25 X STB5A6NW 226365-523 12 terminal AL 6 3/4 NPT X STB5A2YW 226365-513 12 terminal AL 6 M25 X STB5S2NW 226365-540 12 terminal SS 2 (L) 3/4 NPT X STB5S2YW 226365-530 12 terminal SS 2 (L) M25 X STB5S3NW 226365-541 12 terminal SS 3 (T) 3/4 NPT X STB5S3YW 226365-531 12 terminal SS 3 (T) M25 X STB5S5NW 226365-542 12 terminal SS 5 3/4 NPT X STB5S5YW 226365-532 12 terminal SS 5 M25 X Ship Weight: Aluminum = 2.2lb (1.0kg) Stainless Steel = 3lb (1.4kg) *"L" designates 90 degree conduit entry orientation, "ST" designates straight-thru orientation, "T" designates 3-port orientation † If two numbers are listed, the first number is for detector entry and the second number is for field cabling NOTE: Compatibility Type 5 models approved from -55˚C to +125˚C for process control applications Which other Model STB Sensor Termination Box / Separation Kit part numbers can PE Energy supply?The 18 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description226365-133STB3A2NW,AL,3/4 ,QUAD, TOXIC226365-138STB3A2MW,AL,M20/25,QUAD, TOXIC226365-143STB3S5YW,SS,M25,QUAD,TOXIC226365-146STB1S2MW SS M20/M25 QUAD 505226365-147STB1A5NW,AL,3/4 ,QUAD226365-601STB7A5YW,AL,M25 ,QUAD, 5PT226365-602STB7A5NW,AL,3/4 ,QUAD, 5PT226365-603STB7S5YW,SS,M25 ,QUAD, 5PT226365-604STB7S5NW,SS,3/4 ,QUAD, 5PT226365-605STB7A2NW,AL,3/4 ,QUAD, 2PT226365-606STB7A5NB,AL,3/4 ,INMETRO,5PT226365-607STB7S5NB,SS,3/4 ,INMETRO,5PT226365-608STB1S2NB,SS,3/4 ,QUAD, INMETRO226365-651STB7S2YW,SS,M25,QUAD,2PT226365-851STB7S2YK,SS,M25,KAZAKH,2PT226365-901STB7A5YR,AL,M25,RUSS,5PT226365-911STB3A2MR,AL,M20/25,RUS , TOXIC226365-963STB7S5YR,SS,M25,RUSSIA -

Det-Tronics Model STB Sensor Termination Box and Separation Kit
Model STB Series Sensor Termination Box / Separation Kit (Manual: 95-8655) includes a junction box, proper connector board, required hardware to enable proper mounting, and wiring of models GT3000, NTMOS, and C706x series detectors, or any 4-20 mA device. Enables remote installation of sensor for optimum gas detection while offering easy calibration access to FlexVu UD10, GDTB (NTMOS), or U9500 Infiniti One Sensor Termination Box per sensor is required STB Model Matrix MODEL DESCRIPTION STB Sensor Termination Box TYPE COMPATIBILITY 3 Model C706x electrochmical gas sensor/transmitter 7 6 Terminal (for use with GT3000 and NTMOS) TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE # OF PORTS, THREAD TYPE 2M 2 PORT, M20/25 at 90 degree orientation 2N 2 PORT, 3/4" NPT at 90 degree orientation 5Y 5 PORT, M25 5N 5 PORT, 3/4" NPT TYPE APPROVALS* B INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) W FM/CSA/ATEX/IECEx Model STB Sensor Termination Boxes / Separation Kits Model Part Number Use With Material Ports* Threads† FM/CSA/ ATEX/ IECEx VNIIFTRI INMETRO STB7A5YW 226365-601 GT3000/NTMOS AL 5 M25 X STB7A5NW 226365-602 GT3000/NTMOS AL 5 3/4 NPT X STB7S5YW 226365-603 GT3000/NTMOS SS 5 M25 X STB7S5NW 226365-604 GT3000/NTMOS SS 5 3/4 NPT X STB7A2NW 226365-605 GT3000/NTMOS AL 2 3/4 NPT X STB7A5NB 226365-606 GT3000/NTMOS AL 5 3/4 NPT X STB7S5NB 226365-607 GT3000/NTMOS SS 5 3/4 NPT X STB3A2NW 226365-133 C706x toxics AL 2 (L) 3/4 NPT X STB3S5YW 226365-143 C706x toxics SS 5 M25 X STB3A2MW 226365-138 C706x toxics AL 2 (L) M20/M25 X STB3A2MR 226365-911 C706x toxics AL 2 (L) M20/M25 X Ship Weight: Aluminum = 2.2lb (1.0kg) Stainless Steel = 3lb (1.4kg) *"L" designates 90 degree conduit entry orientation, "ST" designates straight-thru orientation, "T" designates 3-port orientation †If two numbers are listed, the first number is for detector entry and the second number is for field cabling -

Det-Tronics PIRDUCT IR Gas Monitor
The Model PIRDUCT DuctWatch (Spec Sheet: 90-1188) is an infrared (IR) based flammable gas detection/monitoring solution ideal for combustion turbine enclosure detection/monitoring and sample air handling ductwork applications. The DuctWatch is easy to install and commission, and does not require expensive extractive sampling system hardware. Providing a full scale measurement range of 0 to 15% LFL (7500 ppm) methane vapor concentration, the DuctWatch delivers a new level of flammable hydrocarbon gas protection for high airflow environments. PIRDUCT is compatible for mounting on any flat mounting surface, and is provided with a solid mounting plate with seal gasket to prevent air leakage. Minimum internal duct width of 3 feet (1 meter) is required for proper instrument clearance and installation. Air movement is required for proper device performance. Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to ATEX EN60079-29-1, FM 6310/6320, and CSA 22.2. PIRDUCT is available in the following configurations: Factory-fit with an aluminum 5-port Det-Tronics PIRTB wiring termination box Factory-fit with a Det-Tronics aluminum 2-port Eagle Quantum Premier DCU No junction box provided on type “5” models Fully compatible with FlexVu UD10 (sold separately), for display readout and calibration capabilities PIRDUCT Model Matrix MODEL DESCRIPTION PIRDUCT Point Infrared DuctWatch Gas Monitor TYPE THREAD TYPE A 3/4" NPT S M25 TYPE SIGNAL OUTPUT 2 4-20 mA with Hydrophobic filter TYPE WIRING TERMINATION JUNCTION BOX 1 Factory-fit with PIRTBA5NW3V (std 4-20 mA), AL, 3/4"NPT cable entry 2 Factory-fit with PIRTBA5LW3V (std 4-20 mA), AL, M25 cable entry 3 Factory-fit with EQ2253DCU (EQP sys only), AL, 3/4"NPT cable entry 4 Factory-fit with EQ2207DCU (EQP sys only), AL, M25 cable entry 5 No factory-fit wiring j-box provided PIRDUCT Models Model Part Number Output w/Hydro Filter Wiring Enclosure Entry thread type # of ports Approvals Ship Weight PIRDUCTB2W2 008945-007 4-20 mA X PIRTBA5LW3V M25 5 FM CSA ATEX IECEx 14.8 lb (6.7 kg) PIRDUCTA2W1 008945-008 4-20 mA X PIRTBA5NW3V 3/4 NPT 5 14.8 lb (6.7 kg) PIRDUCTB2W4 008945-009 EQP only X EQ2207DCU M25 5 14.8 lb (6.7 kg) PIRDUCTA2W3 008945-010 EQP only X EQ2253DCU 3/4 NPT 5 14.8 lb (6.7 kg) PIRDUCTA2W5 008945-011 4-20 mA X none 3/4 NPT na 10.6 lb (4.8 kg) PIRDUCTB2W5 008945-012 4-20 mA X none M25 na 10.6 lb (4.8 kg) PIRDUCT Miscellaneous Accessories Part Number Description Ship Weight 006468-007 7.5% LFL methane gas calibration kit 11.5 lb (5.2 kg) 226166-012 7.5% LFL methane cylinder 1.5 lb (0.7 kg) 006876-002 Hydrophobic Filter Replacement Kit (2 filters) <1.0 lb (< 0.45 kg) -

Det-Tronics PIRECL Accessories and Sample Draw
The AMS TREX Device Communicator is available from Det-Tronics. The intrinsically safe AMS TREX Communicator enable connection to the PIRECL via the onboard optional HART port connection. Features include a 5.7 inch (14.5 cm) resistive touchscreen display, loop power to power a device, and loop diagnostics. The Remote HART Port Kit and Remote HART cable kit (Manual: 95-8553) are used with the Model PIRECL PointWatch Eclipse IR gas detector to provide access to the Eclipse’s optional onboard, intrinsically-safe HART port for a distance up to 20 meters. Cable set is 20 meter long, 2-core, shielded 20 AWG conductors with overall PVC-jacket, and is IEC332 approved. The standard factory-installed Weather Baffle (Spec Sheet: 90-1155) for the PIRECL Eclipse comes with a 3/16” (4.8 mm) barb fitted inlet tube. A special replacement weather baffle is available with a 1/16” FNPT, internally-threaded calibration gas opening. It enables users to install a threaded compression fitting (not supplied) into the baffle for use with plastic or metal tubing, and is 007529-XXX Direct Duct compatible. The Q300A Sample Draw Cup (Manual: 95-8706) enables the Model PIRECL Eclipse to function within a gas sampling system. It consists of an outer cup assembly with stainless-steel, inlet/outlet compression fittings for 0.25 inch diameter tubing, a special inner baffle assembly with external threaded extension, and silicon gaskets to ensure proper cup assembly seal is provided. AMS TREX Device Communicator Part Number Description Ship Weight 103922-003* AMS TREX Device Communicator 7.5 lb (3.4 kg) *Discount does not apply. Remote HART Replicator Kits for use with PIRECL Part Number Description Ship Weight 000118-010 Remote HART Port Kit, includes 20 meter prefab cable set 7.5 lb (3.4 kg) 000118-020* Remote HART Cable Kit, includes 20 meter prefab cable set 7.5 lb (3.4 kg) *Kit requires the use of a Communicator-to-Cable Connector (p/n 000118-021) for connection to the HART field communicator. Spare Parts for HART Port Replicator Kit Part Number Description Ship Weight 000118-011 Cordset, 20 meters intrinsically safe cable with prefab connectors 6 lb (2.7 kg) 000118-012 Stainless steel adapter for PIRECL HART connector <1 lb (<0.45 kg) 000118-013 HART port connector box, IP67 rated, w/stainless connectors <1 lb (<0.45 kg) 000118-016 SS Cap, Male <1 lb (<0.45 kg) 000118-021* Extension cordset, TREX Communicator to 000118-011 1 lb (0.45 kg) *Qty 1 required per each TREX Communicator. PIRECL Weather Baffles Part Number Description Ship Weight 007165-002* Weatherbaffle with std inlet nozzle, w/hydrophobic filter (standard) <1 lb (<0.45 kg) 007165-005 Weatherbaffle w/ 7/16-20 ext threads <1 lb (<0.45 kg) *Inlet nozzle is removeable to provide a 1/16" FNPT inlet. PIRECL Sample Draw Cup Part Number Description Ship Weight 012200-001 Q300A Sample Draw Cup for PIRECL (not included), 1/4" fitting 8 oz (0.23 kg) PIRECL Miscellaneous Parts Part Number Description Ship Weight 006682-002 PIRECL windshield calibration bag <1 lb (<0.45 kg) 009192-001 Cover, calibration nozzle, tethered, clear* <1 lb (<0.45 kg) 102740-002 Calibration magnet† <1 lb (<0.45 kg) 007145-101 Relay Board <1 lb (<0.45 kg) 107427-040 O-ring, 3.75" I.D., j-box cover <1 lb (<0.45 kg) 107427-052 O-ring, 2.43" I.D., weathershield <1 lb (<0.45 kg) 107427-053 O-ring, 3.25" I.D., front flange (internal) <1 lb (<0.45 kg) *Replaces discontinued calibration cap p/n's 102823-001 and 103035-001 †Calibration magnet is provided on the order with a PIRECL -

Det-Tronics PIRECL, PIR9400, and PIRDUCT Certified Calibration Kits
PIRECL, PIR9400, and PIRDUCT Certified Calibration Kits (Spec Sheet: 90-1214) are high accuracy compressed gas calibration kits provided for field calibration of all PointWatch IR detectors. Each kit includes: Two 3.6 ft3 (103 liters) cylinders of Class 2.2 non-flammable, non-toxic compressed gas A 2.5 liter/minute regulator and pressure indicator 3-foot tube Sturdy plastic carrying case The Windshield Calibration Bag enables calibration to be performed in abnormally high wind conditions. The bag is slipped over the gas detector and secured with a Velcro sealing strap. Gas is applied to the detector through the calibration nozzle on the end of the detector. NOTE: PointWatch PIR9400, and PointWatch Eclipse each require their own unique calibration bag model (not included in Calibration Kit). PIRECL, PIR9400, and PIRDUCT Calibration Kits Part Number Gas %LFL % Vol Standard Balance Ship Weight 006468-006 Butane 50% 0.95 ISO Air 11.5 lb (5.23 kg) 006468-022 Butane 50% 0.7 IEC Air 11.5 lb (5.23 kg) 006468-002 Ethane 50% 1.5 ISO Air 11.5 lb (5.23 kg) 006468-021 Ethane 50% 1.2 IEC Air 11.5 lb (5.23 kg) 006468-003 Ethylene 50% 1.35 ISO Air 11.5 lb (5.23 kg) 006468-020 Ethylene 50% 1.15 IEC Air 11.5 lb (5.23 kg) 006468-007* Methane 7.5% 0.375 ISO Air 11.5 lb (5.23 kg) 006468-917† Methane 7.5% 0.33 ISO Air 11.5 lb (5.23 kg) 006468-014 Methane 50% 2.2 IEC Air 11.5 lb (5.23 kg) 006468-914*† Methane 50% 2.2 IEC Air 11.5 lb (5.23 kg) 006468-001 Methane 50% 2.5 ISO Air 11.5 lb (5.23 kg) 006468-906† Methane 50% 2.5 ISO Air 11.5 lb (5.23 kg) 006468-015 Propane 50% 0.85 IEC Air 11.5 lb (5.23 kg) 006468-915† Propane 50% 0.85 IEC Air 11.5 lb (5.23 kg) 006468-004 Propane 50% 1.1 ISO Air 11.5 lb (5.23 kg) 006468-005 Propylene 50% 1 ISO Air 11.5 lb (5.23 kg) 006468-019 Propylene 50% 1 IEC Air 11.5 lb (5.23 kg) 006468-016 Empty kit - no cal gas 11.5 lb (5.23 kg) Replacement Gas Cylinders for Combustible Gas Calibration Kits Part Number Gas %LFL % Vol Standard Balance Ship Weight 226166-006 Zero Air N/A 20.9 Oxygen N/A Nitrogen 1.5 lb (0.7 kg) 226166-011 Butane 50% 0.95 ISO Air 1.5 lb (0.7 kg) 226166-022 Butane 50% 0.7 IEC Air 1.5 lb (0.7 kg) 226166-002 Ethane 50% 1.5 ISO Air 1.5 lb (0.7 kg) 226166-021 Ethane 50% 1.2 IEC Air 1.5 lb (0.7 kg) 226166-902† Ethane 50% 1.5 ISO Air 1.5 lb (0.7 kg) 226166-003 Ethylene 50% 1.35 ISO Air 1.5 lb (0.7 kg) 226166-020 Ethylene 50% 1.15 IEC Air 1.5 lb (0.7 kg) 226166-005 Hydrogen 50% 2.0 ISO Air 1.5 lb (0.7 kg) 226166-012* Methane 7.5% 0.38 ISO Air 1.5 lb (0.7 kg) 226166-917*† Methane 7.5% 0.33 ISO Air 1.5 lb (0.7 kg) 226166-007 Methane 20% 1.0 ISO Air 1.5 lb (0.7 kg) 226166-008 Methane 25% 1.25 ISO Air 1.5 lb (0.7 kg) 226166-009 Methane 35% 1.75 ISO Air 1.5 lb (0.7 kg) 226166-014 Methane 50% 2.2 IEC Air 1.5 lb (0.7 kg) 226166-914† Methane 50% 2.2 IEC Air 1.5 lb (0.7 kg) 226166-001 Methane 50% 2.5 ISO Air 1.5 lb (0.7 kg) 226166-901† Methane 50% 2.5 ISO Air 1.5 lb (0.7 kg) 226166-015 Propane 50% 0.85 IEC Air 1.5 lb (0.7 kg) 226166-915† Propane 50% 0.85 IEC Air 1.5 lb (0.7 kg) 226166-004 Propane 50% 1.1 ISO Air 1.5 lb (0.7 kg) 226166-010 Propylene 50% 1 ISO Air 1.5 lb (0.7 kg) 226166-019 Propylene 50% 1 IEC Air 1.5 lb (0.7 kg) *PIRDUCT †These items are certified for Russian projects Cylinders have an accuracy of +/- 2% with a cylinder size of 6D PIR Calibration Kit Replacement Parts Part Number Description Ship Weight 162552-002 Regulator, 2.5 LPM 8 oz (0.23 kg) 162553-001 Replacement carrying case 8 oz (0.23 kg) 101678-007 Tubing, 3 ft. 8 oz (0.23 kg) 101678-013 Tubing, 100 ft. spool 8 oz (0.23 kg) PIR Calibration Bags Part Number Description Ship Weight 006682-002 PIRECL Windshield calibration bag 8 oz (0.23 kg) 006682-001 PIR9400 Windshield calibration bag 8 oz (0.23 kg) -

Det-Tronics PointWatch Eclipse PIRECL Infrared Carbon Dioxide (CO2) Gas Detector
The PointWatch Eclipse PIRECL Carbon Dioxide Detector (Spec Sheet: 90-1207) is our rugged stainless steel, point infrared gas detector providing detection of carbon dioxide. Standard signal outputs include isolated 4-20 mA output, HART communication protocol, and RS-485 serial communication supporting Modbus. An optional 2-alarm and 1-fault relay package is available. A tri-color LED provides visual display of operating status. The weather baffle provides excellent optics protection with an easy twist-lock removal. Additional features include: Internal wiring compartment saves money and time Heated optics Non-intrusive calibration Handheld communicator capability Ex d, e, ib protection designs CSA, ATEX, CE, IECEx hazardous location certifications DNV type approval - maritime/offshore Remote calibration capability using PIRTB 0-2%/volume (0-20000) full scale range PIRECL CO2 Model Matrix MODEL DESCRIPTION PIRECL PointWatch Eclipse Point Infrared CO2 Gas Detector TYPE THREAD TYPE A 3/4" NPT B Metric M25 TYPE OUTPUT AND MEASUREMENT OPTIONS 3 4-20 mA with HART Protocol & RS-485: CO2 0-2%/vol Full Scale Range TYPE OPTIONAL OUTPUTS A HART Communication Port B HART Communication Port and Relay Board Ex d only D No Optional Outputs E Relay Board Ex d only TYPE WEATHER PROTECTION 1 Weather Baffle with Hydrophobic filter TYPE APPROVALS B INMETRO (Brazil) C CSA/IECEx E ATEX/IECEx R VNIIPO/VNIIFTRI (Russian) TYPE CLASSIFICATION 1 Division/Zone Ex d e 2 Division/Zone Ex d PointWatch Eclipse PIRECL Infrared CO2 Gas Detector - CSA/IECEx Model Part Number Entry thread type Output HART Port Relays Weather protection Div/Zone Ex d e Div/Zone Ex d CSA/ IECEx PIRECLA3A1C1 011904-001 3/4 NPT 4-20 mA X No w/ hydrophobic X X PIRECLA3A1C2 011904-041 3/4 NPT 4-20 mA X No w/ hydrophobic X X PIRECLA3B1C2 011904-005 3/4 NPT 4-20 mA X Yes w/ hydrophobic X X PIRECLB3A1C1 011904-002 M25 4-20 mA X No w/ hydrophobic X X PIRECLB3A1C2 011904-045 M25 4-20 mA X No w/ hydrophobic X X PIRECLB3B1C2 011904-006 M25 4-20 mA X Yes w/ hydrophobic X X PIRECLA3D1C1 011906-001 3/4 NPT 4-20 mA No w/ hydrophobic X X PIRECLA3D1C2 011906-041 3/4 NPT 4-20 mA No w/ hydrophobic X X PIRECLA3E1C2 011906-005 3/4 NPT 4-20 mA Yes w/ hydrophobic X X PIRECLB3D1C1 011906-002 M25 4-20 mA No w/ hydrophobic X X PIRECLB3D1C2 011906-045 M25 4-20 mA No w/ hydrophobic X X PIRECLB3E1C2 011906-006 M25 4-20 mA Yes w/ hydrophobic X X Ship Weight: 11.5 lb (5.2 kg) PointWatch Eclipse PIRECL Infrared CO2 Gas Detector - ATEX/IECEx Model Part Number Entry thread type Output HART Port Relays Weather protection Ex d e Ex d ATEX/ IECEx PIRECLA3A1E1 011904-501 3/4 NPT 4-20 mA X No w/ hydrophobic X X PIRECLA3A1E2 011904-541 3/4 NPT 4-20 mA X No w/ hydrophobic X X PIRECLA3B1E2 011904-505 3/4 NPT 4-20 mA X Yes w/ hydrophobic X X PIRECLB3A1E1 011904-502 M25 4-20 mA X No w/ hydrophobic X X PIRECLB3A1E2 011904-545 M25 4-20 mA X No w/ hydrophobic X X PIRECLB3B1E2 011904-506 M25 4-20 mA X Yes w/ hydrophobic X X PIRECLA3D1E1 011906-501 3/4 NPT 4-20 mA No w/ hydrophobic X X PIRECLA3D1E2 011906-541 3/4 NPT 4-20 mA No w/ hydrophobic X X PIRECLA3E1E2 011906-505 3/4 NPT 4-20 mA Yes w/ hydrophobic X X PIRECLB3D1E1 011906-502 M25 4-20 mA No w/ hydrophobic X X PIRECLB3D1E2 011906-545 M25 4-20 mA No w/ hydrophobic X X PIRECLB3E1E2 011906-506 M25 4-20 mA Yes w/ hydrophobic X X Ship Weight: 11.5 lb (5.2 kg) PIRECL CO2 Calibration Kit Part Number Gas Symbol % Vol PPM Balance Volume (liters) Ship Weight 006468-017 Carbon Dioxide CO2 1 10000 N2 103 11.5 lb (5.23 kg) Nitrogen N2 100 Pure N/A 103 PIRECL CO2 Kit Replacement Cylinders Part Number Gas Symbol % Vol PPM Balance Volume (liters) Ship Weight 227117-020 Carbon Dioxide CO2 1 10000 N2 103 1 lb (0.45 kg) 227117-022 Nitrogen N2 100 Pure N/A 103 1 lb (0.45 kg) -

Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector
The PointWatch Eclipse PIRECL Hydrocarbon Detector (Spec Sheet: 90-1138) is our most rugged stainless steel, point infrared gas detector providing detection of methane, propane, butane and ethylene, among other flammable hydrocarbon gases in the LFL range. Standard signal outputs include isolated 4-20 mA, HART communication protocol, and RS 485 serial communication supporting Modbus. An Eagle Quantum Premier (EQP) version, and optional 2-alarm plus 1-fault relay package are also available. A tri-color LED provides visual display of operating status. The weather baffle provides excellent optics protection with an easy twist-lock removal. Additional features include: Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to ATEX EN60079-29-1, FM 6310/6320, and CSA 22.2 #152 Eagle Quantum Premier model Models available with SIL 2 certification Internal wiring compartment saves money and time spent on installation Heated optics Non-intrusive calibration Immune to poisoning Handheld communicator capability FDT/DTM capable Ex d, e, ib protection designs FM, CSA, ATEX, and IECEx hazardous location certifications DNV and MED offshore certifications Conforms to global life safety requirements for combustible gas when connected through: - Internal relays, EQP Controller, FlexVu UD10, UD10-DCU, - Infiniti U9500, EQ3710 Analog Input Module (AIM) Remote calibration capability using UD10 or model PIRTB junction box Sample draw and duct mount accessories available LON configurations are certified as NFPA 72 Class X devices Fast response output options available PIRECL Model Matrixlex MODEL DESCRIPTION PIRECL PointWatch Eclipse Point Infrared Gas Detector TYPE THREAD TYPE A 3/4" NPT B Metric M25 TYPE OUTPUT AND MEASUREMENT OPTIONS 1 4-20 mA with HART Protocol and RS-485: 0-100% LFL Full Scale Range 4 Eagle Quantum Premier Compatible Only: 0-100% LFL Full Scale Range 11* 4-20 mA with HART Protocol and RS-485: 0-100% LFL Full Scale Range, FAST RESPONSE 14* Eagle Quantum Premier Compatible Only: 0-100% LFL Full Scale Range, FAST RESPONSE TYPE OPTIONAL OUTPUTS A HART Communication Port B HART Communication Port and Relay Board (not compatible with EQP) Ex d only D No Optional Outputs E Relay Board (not compatible with EQP) Ex d only TYPE WEATHER PROTECTION 1 Weather Baffle with Hydrophobic filter 3 Weather Baffle with Hydrophobic filter and 1/16" threaded calibration port 5 No Weather Protection installed TYPE APPROVALS† B INMETRO (BRAZIL) BT SIL/INMETRO (BRAZIL) R VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/IECEx Y CCCF (CHINA) TYPE CLASSIFICATION 1 Division/Zone Ex d e 2 Division/Zone Ex d *FAST RESPONSE Outputs only available with “T” Approval †Type Approvals can use one or more letters to designate the approvals of the product. Typical PIRECL Customer Proposal Qty Model Part Number Description 1 PIRECLA11B1T2 014046-205 3/4 NPT, 4-20 mA, w/relays, w/hydrophobic filter, SIL/FM/CSA/ATEX/IECEx approvals Spare Parts Qty Model Part Number Description 1 NA 007165-002 Weather baffle with standard inlet nozzle w/hydrophobic filter 1 NA 009862-001 PIRECL Module, 4-20 mA, Standard Response 1 NA 009862-001P PIRECL Module, 4-20 mA, Standard Response, Propane Calibration 1 NA 009862-002 PIRECL Module, LON, Standard Response 1 NA 009862-003 PIRECL Module, 4-20 mA, SIL, Standard Response 1 NA 009862-004 PIRECL Module, LON, SIL, Standard Response 1 NA 009862-901 PIRECL Module, 4-20 mA, Russian, Standard Response 1 NA 009862-902 PIRECL Module, LON, Russian, Standard Response 1 NA 009862-903 PIRECL Module, 4-20 mA, SIL, Russian, Standard Response 1 NA 009862-904 PIRECL Module, LON, SIL, Russian, Standard Response 1 NA 009862-005 PIRECL Module, 4-20 mA, SIL, Fast Response 1 NA 009862-006 PIRECL Module, LON, SIL, Fast Response PIRECL PointWatch Eclipse Models - SIL/FM/CSA/ATEX/IECEx -- Fast Response Model Part Number* Threads Output HART Port Relays Weather Protection† Div/Zone Ex d e Div/Zone Ex d Color PIRECLA11A1T1 014046-201 3/4 NPT 4-20 mA X No w/ hydrophobic X PIRECLA11A1T2 014046-241 3/4 NPT 4-20 mA X No w/ hydrophobic X PIRECLA11B1T2 014046-205 3/4 NPT 4-20 mA X Yes w/ hydrophobic X PIRECLA11A3T1 014046-210 3/4 NPT 4-20 mA X No 1/16 NPT w/hydro X PIRECLA11A3T2 014046-242 3/4 NPT 4-20 mA X No 1/16 NPT w/hydro X PIRECLA14A1T1 014046-212 3/4 NPT EQP X No w/ hydrophobic X PIRECLA14A1T2 014046-243 3/4 NPT EQP X No w/ hydrophobic X PIRECLA14A3T1 014046-216 3/4 NPT EQP X No 1/16 NPT w/hydro X PIRECLA14A3T2 014046-244 3/4 NPT EQP X No 1/16 NPT w/hydro X PIRECLB11A1T1 014046-202 M25 4-20 mA X No w/ hydrophobic X PIRECLB11A1T2 014046-245 M25 4-20 mA X No w/ hydrophobic X PIRECLB11B1T2 014046-206 M25 4-20 mA X Yes w/ hydrophobic X PIRECLB11A3T1 014046-240 M25 4-20 mA X No 1/16 NPT w/hydro X PIRECLB11A3T2 014046-246 M25 4-20 mA X No 1/16 NPT w/hydro X PIRECLB14A1T1 014046-213 M25 EQP X No w/ hydrophobic X PIRECLB14A1T2 014046-247 M25 EQP X No w/ hydrophobic X PIRECLB14A3T1 014046-217 M25 EQP X No 1/16 NPT w/hydro X PIRECLB14A3T2 014046-248 M25 EQP X No 1/16 NPT w/hydro X PIRECLA11D1T1 014048-201 3/4 NPT 4-20 mA No w/ hydrophobic X PIRECLA11D1T2 014048-241 3/4 NPT 4-20 mA No w/ hydrophobic X PIRECLA11E1T2 014048-205 3/4 NPT 4-20 mA Yes w/ hydrophobic X PIRECLA11D3T1 014048-210 3/4 NPT 4-20 mA No 1/16 NPT w/hydro X PIRECLA11D3T2 014048-242 3/4 NPT 4-20 mA No 1/16 NPT w/hydro X PIRECLA14D1T1 014048-212 3/4 NPT EQP No w/ hydrophobic X PIRECLA14D1T2 014048-243 3/4 NPT EQP No w/ hydrophobic X PIRECLA14D3T1 014048-216 3/4 NPT EQP No 1/16 NPT w/hydro X PIRECLA14D3T2 014048-244 3/4 NPT EQP No 1/16 NPT w/hydro X PIRECLB11D1T1 014048-202 M25 4-20 mA No w/ hydrophobic X PIRECLB11D1T2 014048-245 M25 4-20 mA No w/ hydrophobic X PIRECLB11E1T2 014048-206 M25 4-20 mA Yes w/ hydrophobic X PIRECLB11D1T2 014048-245-LG M25 4-20 mA No w/ hydrophobic X Light Gray PIRECLB11D3T1 014048-240 M25 4-20 mA No 1/16 NPT w/hydro X PIRECLB11D3T2 014048-246 M25 4-20 mA No 1/16 NPT w/hydro X PIRECLB14D1T1 014048-213 M25 EQP No w/ hydrophobic X PIRECLB14D1T2 014048-247 M25 EQP No w/ hydrophobic X PIRECLB14D3T1 014048-217 M25 EQP No 1/16 NPT w/hydro X PIRECLB14D3T2 014048-248 M25 EQP No 1/16 NPT w/hydro X Ship Weight: 11.5lb (5.2kg) *Part numbers listed are factory calibrated to methane. Add a "P" to the end of the part number for propane (example: 014046-201P). Add "E" for ethylene or "B" for butane. †Units with 1/16 NPT are 007529-XXX Duct Kit compatible Which other PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector part numbers can PE Energy supply?The 168 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description000118-012PIRECL ADAPTER, HART PORT007168-003PIRECLA1A2W1 GAS DETECTOR007168-013PIRECLB4A1W1 GAS DETECTOR007168-015PIRECLB4A2W1 GAS DETECTOR007168-016PIRECLA4A3W1 GAS DETECTOR007168-017PIRECLB4A3W1 GAS DETECTOR007168-020PIRECLA1A1B2 GAS DETECTOR007168-021PIRECLA1B1B2 GAS DETECTOR007168-022PIRECLA1A5W1 GAS DETECTOR007168-023PIRECLA1B5W2 GAS DETECTOR007168-024PIRECLB1A5W1 GAS DETECTOR007168-027PIRECLB1B2W2 GAS DETECTOR007168-038PIRECLA1B3W2 GAS DETECTOR007168-039PIRECL KDS PN 422082007168-040PIRECLB1A3W1 GAS DETECTOR007168-044PIRECLA4A3W2 GAS DETECTOR007168-046PIRECLB1A3W2 GAS DETECTOR007168-047PIRECLB4A1W2 GAS DETECTOR007168-048PIRECLB4A3W2 GAS DETECTOR007168-051PIRECLA4A1B2 GAS DETECTOR007168-101PIRECLA1A1Y1 GAS DETECTOR007168-102PIRECLB1A1Y1 GAS DETECTOR007168-103PIRECLA1A2Y1 GAS DETECTOR007168-104PIRECLB1A2Y1 GAS DETECTOR007168-105PIRECLA1B1Y2 GAS DETECTOR007168-106PIRECLB1B1Y2 GAS DETECTOR007168-107PIRECLA1B2Y2 GAS DETECTOR007168-108PIRECLB1A1Y2 GAS DETECTOR007168-110PIRECLA1A3Y1 GAS DETECTOR007168-112PIRECLA4A1Y1 GAS DETECTOR007168-113PIRECLB4A1Y1 GAS DETECTOR007168-114PIRECLA4A2Y1 GAS DETECTOR007168-115PIRECLB4A2Y1 GAS DETECTOR007168-116PIRECLA4A3Y1 GAS DETECTOR007168-117PIRECLB4A3Y1 GAS DETECTOR007168-203PIRECLA1A2T1 GAS DETECTOR007168-204PIRECLB1A2T1 GAS DETECTOR007168-212PIRECLA4A1T1 GAS DETECTOR EQP007168-213PIRECLB4A1T1 GAS DETECTOR EQP007168-214PIRECLA4A2T1 GAS DETECTOR EQP007168-215PIRECLB4A2T1 GAS DETECTOR EQP007168-216PIRECLA4A3T1 GAS DETECTOR EQP007168-217PIRECLB4A3T1 GAS DETECTOR EQP007168-218PIRECLB1A2T2 GAS DETECTOR007168-220PIRECLA1A1BT2 GAS DETECTOR007168-221PIRECLA1B1BT2 GAS DETECTOR007168-227PIRECLB1B2T2 GAS DETECTOR007168-240PIRECLB1A3T1 GAS DETECTOR007168-243PIRECLA4A1T2 GAS DETECTOR007168-244PIRECLA4A3T2 GAS DETECTOR007168-246PIRECLB1A3T2 GAS DETECTOR007168-248PIRECLB4A3T2 GAS DETECTOR007168-251PIRECLA4A1BT2 GAS DETECTOR007168-601PIRECLB1A1BT2 GAS DETECTOR007168-841PIRECLA1A1SK2 GAS DETECTOR007168-845PIRECLB1A1K2 GAS DETECTOR007168-862PIRECLB1A1SK1 GAS DETECTOR007168-865PIRECLB1A1SK2 GAS DETECTOR007168-866PIRECLB1B1SK2 GAS DETECTOR007168-873PIRECLB4A1SK2 GAS DETECTOR007168-902PIRECLB1A1R1 GAS DETECTOR007168-904PIRECLB1A2R1 GAS DETECTOR007168-905PIRECLB1A1R2 GAS DETECTOR007168-906PIRECLB1B1R2 GAS DETECTOR007168-907PIRECLB1A2R2 GAS DETECTOR007168-908PIRECLB1B2R2 GAS DETECTOR007168-910PIRECLA1A3R1 GAS DETECTOR007168-913PIRECLB4A1R2 GAS DETECTOR007168-915PIRECLB4A2R2 GAS DETECTOR,RUSS007168-916PIRECLA4A3R1 GAS DETECTOR007168-925PIRECLB1B5R2 GAS DETECTOR007168-940PIRECLB1A3R1 GAS DETECTOR007168-946PIRECLB1A3R2 GAS DETECTOR007168-965PIRECLB1A1SR2 GAS DETECTOR007168-968PIRECLB1B2SR2 GAS DETECTOR007168-973PIRECLB4A1SR2 GAS DETECTOR007168-975PIRECLB4A2SR2 GAS DETECTOR007168-985PIRECLA1B1SR2 GAS DETECTOR010195-002PIRECLB1D1W1 GAS DETECTOR010195-007PIRECLA1E2W2 GAS DETECTOR010195-010PIRECLA1D3W1 GAS DETECTOR010195-016PIRECLA4D3W1 GAS DETECTOR010195-020PIRECLA1D1B2 GAS DETECTOR010195-022PIRECLA1D5W1 GAS DETECTOR010195-023PIRECLA1E5W2 GAS DETECTOR010195-038PIRECLA1E3W2 GAS DETECTOR010195-040PIRECLB1D3W1 GAS DETECTOR010195-042PIRECLA1D3W2 GAS DETECTOR010195-046PIRECLB1D3W2 GAS DETECTOR010195-051PIRECLA4D1B2 GAS DETECTOR010195-055PIRECLB4D5W2 GAS DETECTOR010195-101PIRECLA1D1Y1 GAS DETECTOR010195-105PIRECLA1E1Y2 GAS DETECTOR010195-106PIRECLB1E1Y2 GAS DETECTOR010195-112PIRECLA4D1Y1 GAS DETECTOR010195-141PIRECLA1D1Y2 GAS DETECTOR010195-143PIRECLA4D1Y2 GAS DETECTOR010195-145PIRECLB1D1Y2 GAS DETECTOR010195-147PIRECLB4D1Y2 GAS DETECTOR010195-202PIRECLB1D1T1 GAS DETECTOR010195-203PIRECLA1D2T1 GAS DETECTOR010195-204PIRECLB1D2T1 GAS DETECTOR010195-212PIRECLA4D1T1 GAS DETECTOR EQP010195-214PIRECLA4D2T1 GAS DETECTOR EQP010195-215PIRECLB4D2T1 GAS DETECTOR EQP010195-216PIRECLA4D3T1 GAS DETECTOR EQP010195-217PIRECLB4D3T1 GAS DETECTOR EQP010195-218PIRECLB1D2T2 GAS DETECTOR010195-220PIRECLA1D1BT2 GAS DETECTOR010195-222PIRECLA1D5T2 GAS DETECTOR010195-227PIRECLB1E2T2 GAS DETECTOR010195-238PIRECLA1E3T2 GAS DETECTOR010195-240PIRECLB1D3T1 GAS DETECTOR010195-242PIRECLA1D3T2 GAS DETECTOR010195-243PIRECLA4D1T2 GAS DETECTOR010195-244PIRECLA4D3T2 GAS DETECTOR010195-246PIRECLB1D3T2 GAS DETECTOR010195-247PIRECLB4D1T2 GAS DETECTOR010195-248PIRECLB4D3T2 GAS DETECTOR010195-251PIRECLA4D1BT2 GAS DETECTOR010195-252PIRECLB1D5T2 GAS DETECTOR010195-843PIRECLA4D1K2 GAS DETECTOR010195-856PIRECLB1E1SK2 GAS DETECTOR010195-942PIRECLA1D3SR2 GAS DETECTOR010195-945PIRECLB1D1SR2 GAS DETECTOR011904-001PIRECLA3A1C1 GAS DETECTOR011904-002PIRECLB3A1C1 GAS DETECTOR011904-005PIRECLA3B1C2 GAS DETECTOR011904-006PIRECLB3B1C2 GAS DETECTOR011904-007PIRECLB3A1B1 GAS DETECTOR011904-020PIRECLA3A1B2 GAS DETECTOR011904-041PIRECLA3A1C2 GAS DETECTOR011904-045PIRECLB3A1C2 GAS DETECTOR011904-501PIRECLA3A1E1 GAS DETECTOR011904-502PIRECLB3A1E1 GAS DETECTOR011904-505PIRECLA3B1E2 GAS DETECTOR011904-506PIRECLB3B1E2 GAS DETECTOR011904-541PIRECLA3A1E2 GAS DETECTOR011904-545PIRECLB3A1E2 GAS DETECTOR011904-605PIRECLA3B1B2 GAS DETECTOR011906-001PIRECLA3D1C1 GAS DETECTOR011906-002PIRECLB3D1C1 GAS DETECTOR011906-005PIRECLA3E1C2 GAS DETECTOR011906-006PIRECLB3E1C2 GAS DETECTOR011906-020PIRECLA3D1B2 GAS DETECTOR011906-041PIRECLA3D1C2 GAS DETECTOR011906-045PIRECLB3D1C2 GAS DETECTOR011906-501PIRECLA3D1E1 GAS DETECTOR011906-502PIRECLB3D1E1 GAS DETECTOR011906-505PIRECLA3E1E2 GAS DETECTOR011906-506PIRECLB3E1E2 GAS DETECTOR011906-541PIRECLA3D1E2 GAS DETECTOR011906-545PIRECLB3D1E2 GAS DETECTOR011906-945PIRECLB3D1R2 GAS DETECTOR014046-245-LGPIRECLB11A1T2-LG DETECTOR014046-605PIRECLA11B1BT2 GAS DETECTOR014046-641PIRECLA11A1BT2 GAS DETECTOR014046-642PIRECLB11A1BT2 GAS DETECTOR014046-643PIRECLA14A1BT2 GAS DETECTOR014046-644PIRECLA14A3BT2 DETECTOR EQP014046-646PIRECLA11A1BT1 GAS DETECTOR014048-223PIRECLA11E5T2 DETECTOR014048-345PIRECLB11D1T2-YO DETECTOR014048-346PIRECLB11D1T2-LG GAS DETECTOR014048-347PIRECLB11D1T2-B DETECTOR014048-633PIRECLB11D2T2 GAS DETECTOR014048-641PIRECLA11D1BT2 DETECTOR014048-643PIRECLA14D1BT2 DETECTOR -

Det-Tronics Ultra-High Speed Flame Detection and Releasing System Remote Input Output (Ultra FDRS RIO)
The Ultra FDRS RIOmodel allows for the remote installation of high speed deluge modules (HSDM) and enhanced discreet input output modules (EDIO). This concept allows for installation of the Ultra FDRS 2400, 3600, or 4800 models in a given area while the Ultra FDRS RIO is installed in a different area that is located physically closer to individual work areas. The Ultra FDRS RIO cabinet is ordered as needed in a quantity that is sized to the needs of the particular application. Ultra FDRS Model RIO Red Painted (RAL 3020) Steel Enclosure, locking key handle door, mounting feet, NEMA 4 36”(H) x 24”(W) x 8”(D) (914mm x 610mm x 203mm) Accommodates up to eighteen (18) inputs from flame detectors (Class B) Provides up to eighteen (18) 24VDC ultra-high-speed outputs (Class B) Provides up to seven (7) non-high speed inputs or outputs Lockable Physical Solenoid Disconnect Switches Interposing terminals to accommodate field wiring FM/CSA and SIL2 approved for indoor, non-hazardous areas Permits compliance with NFPA 72 and NFPA 15 (Chapter 12) Ultra-High-Speed Flame Detection and Releasing System (Ultra FDRS) Model Enclosure Size (mm) Door Window EQP Controller Quantity HSDM Quantity EDIO Quantity Physical Disconnect Switch Quantity Flame Detector Inputs Ultra High Speed 24VDC Outputs Non High Speed I/O Ultra FDRS 2400 24"x20"x8" (610mm x 508mm x 203mm) Yes 1 1 1 2 6 6 7 Ultra FDRS 3600 36"x24"x8" (914mm x 610mm x 203mm) Yes 1 3 1 6 18 18 7 Ultra FDRS 4800 48"x24"x10" (1219mm x 610mm x 254mm) Yes 1 5 1 10 30 30 7 Ultra FDRS RIO 36”x24”x8” (914mm x 610mm x 203mm) No 0 3 1 6 18 18 7 *Other non-standard Ultra FDRS options are available. These non-standard options may incur higher costs and longer lead times. Contact Det-Tronics for additional information on building a system that meets your requirements. Det-Tronics Ultra FDRS systems are listed—an official designation that means the Authority Having Jurisdiction (AHJ) recognizes the systems as acceptable and the installed systems pass regular inspections. -

Det-Tronics Ultra-High-Speed Flame Detection and Releasing System (Ultra FDRS)
As part of providing a listed flame detection and releasing system to the ultra-high-speed market segment, Detector Electronics Corporation offers several pre-engineered certified system options. Three standardized models are available to meet the needs of the small, medium, and large ultra-high-speed system user. These models utilize the proven EQ3900 Approved Fire and Gas Releasing Cabinet solution. The Det-Tronics Ultra-High-Speed Flame Detection and Releasing System (Ultra FDRS) is an Eagle Quantum Premier® (EQP) based safety solution certified SIL 2 capable to function in challenging, high-hazard applications. Each model includes an appropriately sized cabinet that houses an Eagle Quantum Premier Controller, High Speed Deluge Module(s), Enhanced Discreet Input Output Module(s), physical solenoid disconnect switches, and field wiring termination terminals. Ultra FDRS Model 2400 Red Painted (RAL 3020) Steel Enclosure, locking key handle door, fixed window, mounting feet, NEMA 4 24”(H) x 20”(W) x 8”(D) (610mm x 508mm x 203mm) Includes one (1) Eagle Quantum Premier Safety System Controller Accommodates up to six (6) inputs from flame detectors (Class B) Provides up to six (6) 24VDC ultra-high-speed outputs (Class B) Provides up to seven (7) non-high speed inputs or outputs Lockable Physical Solenoid Disconnect Switches Interposing terminals to accommodate field wiring FM/CSA and SIL2 approved for indoor, non-hazardous areas Permits compliance with NFPA 72 and NFPA 15 (Chapter 12) Ultra FDRS Model 3600 Red Painted (RAL 3020) Steel Enclosure, locking key handle door, fixed window, mounting feet, NEMA 4 36”(H) x 24”(W) x 8”(D) (914mm x 610mm x 203mm) Includes one (1) Eagle Quantum Premier Safety System Controller Accommodates up to eighteen (18) inputs from flame detectors (Class B) Provides up to eighteen (18) 24VDC ultra-high-speed outputs (Class B) Provides up to seven (7) non-high speed inputs or outputs Lockable Physical Solenoid Disconnect Switches Interposing terminals to accommodate field wiring FM/CSA and SIL2 approved for indoor, non-hazardous areas Permits compliance with NFPA 72 and NFPA 15 (Chapter 12) Ultra FDRS Model 4800 Red Painted (RAL 3020) Steel Enclosure, locking key handle door, fixed window, mounting feet, NEMA 4 48”(H) x 24”(W) x 10”(D)(1219mm x 610mm x 254mm) Includes one (1) Eagle Quantum Premier Safety System Controller Accommodates up to thirty (30) inputs from flame detectors (Class B) Provides up to thirty (30) 24VDC ultra-high-speed outputs (Class B) Provides up to seven (7) non-high speed inputs or outputs Lockable Physical Solenoid Disconnect Switches Interposing terminals to accommodate field wiring FM/CSA and SIL2 approved for indoor, non-hazardous areas Permits compliance with NFPA 72 and NFPA 15 (Chapter 12)