Det-Tronics FlexVu UD10 Universal Display
Bulk Orders
FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications that require a gas detector with digital read-out of detected gas levels. The FlexVu UD10 Universal Display Unit is designed for use with various Det-Tronics gas sensor/transmitters. The display unit is designed and approved as a stand-alone device and performs all the functions of a gas controller.
- Compliance to ANSI/ISA-12.13.01-2000 performance standard
- Compliance to ISA-92.0.01 Part 1 performance standard, and EN50104 for oxygen depletion
- Performance certified to FM 6310/6320, CSA 22.2 #152, ATEX EN60079-29-1, and IEC60079-29-1
- Approved as a stand-alone combustible gas and low concentration toxic controller, when using the relay contacts
- Division Approval Ratings: FM and CSA
- Zone Approval Ratings: FM, CSA, ATEX, and IECEx
- Eagle Quantum Premier model
- Universal design supports a variety of Det-Tronics sensors/detectors
- Non-intrusive menu allows device configuration and calibration without de-classifying the hazardous area
- Continuously displays gas level, gas type, and units measured
- Data logger for event time and date stamping
- Heated and backlit display
- Relay, modbus, and linear isolated/non-isolated 4-20 mA output with HART, configurable 4-20 mA output loop monitoring
- IP66 rated
FlexVu UD10 Model Matrix
MODEL | DESCRIPTION |
UD10 | Universal Display Unit |
TYPE | MATERIAL |
A | Aluminum |
S | Stainless Steel (316) |
TYPE | THREAD TYPE |
5M | 5 Port, Metric M25 |
5N | 5 Port, 3/4″ NPT |
TYPE | OUTPUTS |
25 | Relay, 4-20mA, RS485, HART |
28 | EQP / DCU Emulator |
TYPE | APPROVALS* |
B | INMETRO (BRAZIL) |
R | VNIIFTRI (RUSSIA) |
S | SIL |
T | SIL/FM/CSA/ATEX/IECEx |
W | FM/CSA/ATEX/IECEx |
TYPE | CLASSIFICATION (Div/Zone) |
2 | Ex d (Flameproof) |
TYPE | OPTIONAL CONDITIONING BOARD |
(Blank) | None |
C | CGS |
N | NTMOS† |
* Type Approvals can use one or more letters to designate the approvals of the product.
† Not required for DCU Emulator model.
FlexVu UD10 Universal Display
Model | Part Number | Material | Threads | Relay 4-20 RS485 HART |
EQP/DCU Emulator |
Cond. Board |
FM/CSA/ ATEX/IECEx |
SIL 2 |
UD10A5M25T2 | 010765-001 | AL | M25 | X | X | X | ||
UD10A5N25T2 | 010765-002 | AL | 3/4 NPT | X | X | X | ||
UD10S5M25T2 | 010765-003 | 316 SS | M25 | X | X | X | ||
UD10S5N25T2 | 010765-004 | 316 SS | 3/4 NPT | X | X | X | ||
UD10A5M28W2 | 010765-005 | AL | M25 | X | X | |||
UD10A5N28W2 | 010765-006 | AL | 3/4 NPT | X | X | |||
UD10S5M28W2 | 010765-007 | 316 SS | M25 | X | X | |||
UD10S5N28W2 | 010765-008 | 316 SS | 3/4 NPT | X | X | |||
UD10A5M25W2C | 010254-001 | AL | M25 | X | CGS | X | ||
UD10A5N25W2C | 010254-002 | AL | 3/4 NPT | X | CGS | X | ||
UD10S5M25W2C | 010254-003 | 316 SS | M25 | X | CGS | X | ||
UD10S5N25W2C | 010254-004 | 316 SS | 3/4 NPT | X | CGS | X | ||
UD10A5M28W2C | 010254-005 | AL | M25 | X | CGS | X | ||
UD10A5N28W2C | 010254-006 | AL | 3/4 NPT | X | CGS | X | ||
UD10S5M28W2C | 010254-007 | 316 SS | M25 | X | CGS | X | ||
UD10S5N28W2C | 010254-008 | 316 SS | 3/4 NPT | X | CGS | X | ||
UD10A5M25W2N | 010252-001 | AL | M25 | X | NTMOS | X | ||
UD10A5N25W2N | 010252-002 | AL | 3/4 NPT | X | NTMOS | X | ||
UD10S5M25W2N | 010252-003 | 316 SS | M25 | X | NTMOS | X | ||
UD10S5N25W2N | 010252-004 | 316 SS | 3/4 NPT | X | NTMOS | X | ||
Ship Weight: Aluminum = 4.2lb (1.9kg) Stainless Steel = 10.5lb (4.8kg) |
FlexVu UD10 Spare Modules
Part Number | Description | Output | Ship Weight |
010569-001 | UD10 Display Module | Relay/4-20mA | 1 lb (0.45 kg) |
010535-001 | UD10 Display Module | EQP-DCU | 1 lb (0.45 kg) |
FlexVu UD10 Miscellaneous Spare Parts
Part Number | Description | Ship Weight |
011919-001 | UD10/NTMOS REPLACEMENT BOARD | <1 lb (<0.45 kg) |
FlexVu UD10 Accessories
Part Number | Description | Ship Weight |
009700-001 | Magnetic Tool | <1 lb (0.45 kg) |
014019-001 | Gas Inspector 11 CD | <1 lb (0.45 kg) |
014020-001 | W6300G1006 Gas Inspector 11 Kit (includes CD) | <1 lb (0.45 kg) |
102988-002 | Plug, 5.0mm, 6 Position – P2 | <1 lb (0.45 kg) |
102988-026 | Plug, 5.0mm, 3 Position – P1 (J10, CGS) | <1 lb (0.45 kg) |
102988-028 | Plug, 5.0mm, 5 Position – (J3, CGS) | <1 lb (0.45 kg) |
103726-002 | Plug, 3.5mm, 3 Position – J2 | <1 lb (0.45 kg) |
103726-004 | Plug, 3.5mm, 5 Position – J3 | <1 lb (0.45 kg) |
103726-011 | Plug, 3.5mm, 12 Position – J4 | <1 lb (0.45 kg) |
Stop Plugs and Reducers
Part Number | Description | Ship Weight |
101197-001* | Stop Plug, 3/4″ NPT, AL | <1 lb (<0.45 kg) |
101197-004* | Stop Plug, 3/4″ NPT, SS | <1 lb (<0.45 kg) |
101197-005 | Stop Plug, M25, AL, IP66 | <1 lb (<0.45 kg) |
101197-003 | Stop Plug, M25, SS, IP66 | <1 lb (<0.45 kg) |
010816-001* | Stop Plug, 20 Pack, 3/4″NPT, AL | 1 lb (0.45 kg) |
010817-001* | Stop Plug, 20 Pack, 3/4″NPT, SS | 2 lb (0.9 kg) |
010818-001 | Stop Plug, 20 Pack, M25, AL,IP66 | 1.5 lb (0.7 kg) |
010819-001 | Stop Plug, 20 Pack, M25, SS,IP66 | 3.25 lb (1.5 kg) |
102804-001 | Reducer, M25 to M20, AL | <1 lb (<0.45 kg) |
102804-003 | Reducer, M25 to M20, SS | <1 lb (<0.45 kg) |
*NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape.
FlexVu® UD10 Universal Display Repair / Upgrade Kit
(Technical Bulletin: 76-1046) The UD10 Repair/Upgrade Kit allows field conversion of an existing U9500 Infiniti® Transmitter, Model 505 Transmitter, or Eagle Quantum Premier® Digital Communication Unit (DCU) to a FlexVu® UD10 Universal Display. The existing junction box base, along with the existing conduit and field wiring, can be left in place and do not need to be replaced.
FlexVu UD10 Upgrade Kit
Model | Part Number | Material | Threads | Relay 4-20 RS485 HART |
EQP/ DCU Emulator |
Cond. Board |
FM/ CSA/ ATEX/ IECEx |
SIL 2 |
UPGRADE KIT UD10A5M25T2 | 010970-001 | AL | M25 | X | X | X | ||
UPGRADE KIT UD10A5N25T2 | 010970-002 | AL | 3/4 NPT | X | X | X | ||
UPGRADE KIT UD10S5M25T2 | 010970-003 | 316 SS | M25 | X | X | X | ||
UPGRADE KIT UD10S5N25T2 | 010970-004 | 316 SS | 3/4 NPT | X | X | X | ||
UPGRADE KIT UD10A5M28W2 | 010970-005 | AL | M25 | X | X | |||
UPGRADE KIT UD10A5N28W2 | 010970-006 | AL | 3/4 NPT | X | X | |||
UPGRADE KIT UD10S5M28W2 | 010970-007 | 316 SS | M25 | X | X | |||
UPGRADE KIT UD10S5N28W2 | 010970-008 | 316 SS | 3/4 NPT | X | X | |||
UPGRADE KIT UD10A5M25W2C | 010971-001 | AL | M25 | X | CGS | X | ||
UPGRADE KIT UD10A5N25W2C | 010971-002 | AL | 3/4 NPT | X | CGS | X | ||
UPGRADE KIT UD10S5M25W2C | 010971-003 | 316 SS | M25 | X | CGS | X | ||
UPGRADE KIT UD10S5N25W2C | 010971-004 | 316 SS | 3/4 NPT | X | CGS | X | ||
UPGRADE KIT UD10A5M28W2C | 010971-005 | AL | M25 | X | CGS | X | ||
UPGRADE KIT UD10A5N28W2C | 010971-006 | AL | 3/4 NPT | X | CGS | X | ||
UPGRADE KIT UD10S5M28W2C | 010971-007 | 316 SS | M25 | X | CGS | X | ||
UPGRADE KIT UD10S5N28W2C | 010971-008 | 316 SS | 3/4 NPT | X | CGS | X | ||
Ship Weight: Aluminum = 3.5 lb (1.6 kg) Stainless Steel = 8.7 lb (3.9 kg) |
Related products
-
Teledyne Detcon IR-700-CO2 Carbon Dioxide Sensor
Model IR-700-CO2 is a non-intrusive “Smart” sensor designed to detect and monitor carbon dioxide gas in air using miniature non-dispersive Infrared Optical (NDIR) sensor technology. Available in a low and a high range version, ranges of detection (by volume) are 0-0.3%, 0-1%, 0-3%, 0-5% (low range version) and 0-10%, 0-25%, 0-50%, and 0-100% (high range version). The plug-in, field replaceable detector provides a selective response to CO2 and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CO2 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR700-CO2 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Additional integration options include a Remote Alarm Module (RAM) & HART. Detcon’s carbon dioxide gas sensor has an infinite shelf life and is supported by a 5-year pro-rated warranty. Order Guide Specify junction box options (below) PN 967-405520-005 - IR-700-CO2 (5% Range) Sensor Assembly (no J-box) PN 967-401520-005 - IR-700-CO2 (5% Range) Sensor Assembly with Aluminum J-Box PN 967-404520-005 - IR-700-CO2 (5% Range) Sensor Assembly with 316 SS J-Box PN 967-425520-025 - IR-700-CO2 (25% Range) Sensor Assembly (no J-box) PN 967-421520-025 - IR-700-CO2 (25% Range) Sensor Assembly with Aluminum J-Box PN 967-424520-025 - IR-700-CO2 (25% Range) Sensor Assembly with 316 SS J-Box APPLICATIONS: Chemicals Pesticides Agriculture & Horticulture Food & Beverage Bottling Plants Sewer Entry Waste Water Treatment Plants Coal Gasification Pulp & Paper Mills Enhanced Oil Recovery FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry I/O Protection Water-Resistant, Corrosion-Resistant, Vibration-Resistant Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Non-dispersive Infrared Optical (NDIR) - CO2 Sub-miniature plug-in field replaceable Sensor Life 5 years typical Measurement Range (% by volume) 0-0.3, 0-0.5, 0-1, 0-3, 0-5 (low range version) 0-10, 0-15, 0-20, 0-25, 0-50, 0-100 (high range version) Accuracy/Repeatability ±5% of range Response Time T50 < 15 seconds, T90 < 40 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus ATEX CE Marking Warranty Plug-in detector - 5 year pro-rated Transmitter - 2 Years ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 0.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon FP-700 Combustible Gas Sensor
Model FP-700 is a non-intrusive "Smart" sensor designed to detect and monitor combustible gases in air over the range of 0-100% LEL using catalytic bead sensor technology. The plug-in, field replaceable detector is poison-resistant and features over-sized gold-plated connections that help prevent corrosion. The FP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model FP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model FP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), and HART. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty. Order Guide Specify junction box options (below) PN 967-525520-100 - FP-700 Sensor Assembly (no junction box) PN 967-521520-100 - FP-700 Sensor Assembly with Aluminum Junction Box PN 967-524520-100 - FP-700 Sensor Assembly with 316 SS Junction Box PN 9H7-521520-100 - FP-700 Sensor Assembly with HART in Aluminum Junction Box PN 9H7-524520-100 - FP-700 Sensor Assembly with HART in 316 SS Junction Box PN 9R7-524520-100 - FP-700 Sensor Assembly with RAM in Aluminum Junction Box PN 9R7-524520-100 - FP-700 Sensor Assembly with HART in 316SS Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Matched-pair catalytic bead detector Plug-in field replaceable Sensor Life 3 to 5 years typical Measurement Range 0-100% LEL (lower explosive limit) Accuracy/Repeatability ±3% 0-50% LEL; ±5% 50-100% LEL Response/Clearing Time T50 <10 seconds; T90 <30 seconds Zero Drift <5% per year Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CCSAUS Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSUS Performance to ANSI/ISA 60079-29-1 (12.13.01)-2013 and CSA 22.2 #152 ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in detector - 2 years Transmitter - 2 Years Environmental Specifications Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-99% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 1.0A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Operating Temperature, Loop, Input Voltage, Bridge Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Wireless Integration Module (Detcon Model RXT-320 SmartWireless® Transceivers Product Data Sheet -
Oldham Simtronics OLCT 10N Fixed Digital Gas Detector
The OLCT 10N is a digital gas detector designed for detection of the most common gases in commercial and light industrial applications. Intended for use in combination with the MX 16, MX 32, MX43 or MX 256, the OLCT 10N provides a fast and accurate response. Up to 32 detectors can be connected on the same digital line or distributed on 8 lines. All transmitter information is received by the controller in less than 1 second. Non-intrusive operator interface requires only a simple magnetic wand and allows one man calibration without opening the enclosure, and calibration information, such as span reserve, is stored in the station. Certified IP65 and ATEX 3 GD for its explosive version, it is authorized for use in ATEX zones 2 and 22 and is waterproof and dustproof. Accessories Shock guard protector (2123717) OLCT 10N calibration tool kit (6331163) The OLCT 10N is the ideal solution for safe areas or zone 2 (22) ATEX locations. Configuration example Features: Detection of combustible gases, toxic gases or oxygen Digital technology Non-intrusive calibration Cost savings on wiring installation Applications: Cold rooms Car parks Technical features: Détecteur numérique OLCT 10N Range CH4, C3 H8, C4 H10, H2 O2 (> 2 years) O2 (5 years) CO H2S NO NO2 NH3 CO2 0-100 % LIE (-20°C à + 55°C) 0-30 % vol (-20°C à + 50°C) 0-30 % vol (-40°C à + 50°C) 0-300 ppm / 0-1000 ppm (-20°C à + 50°C) 0-30 ppm / 0-100 ppm (-20°C à + 50°C) 0-100 ppm / 0-300 ppm (-20°C à + 50°C) 0-10 ppm / 0-30 ppm (-20°C à + 50°C) 0-100 ppm / 0-1000 ppm (-20°C à + 40°C) 0-5000ppm / 0-5% vol / 0-100% vol (-40 à + 50°C) Output RS485 Modbus, proprietary protocol Power supply 12-30 Vcc Consumption Electrochemical sensor: Catalytic sensor : CO2 Infrared sensor: 2.5 mA in normal operation @ 24 Vdc 50 mA in normal operation @ 24 Vdc 20mA in normal operation @24Vdc Calibration Non-intrusive Cable inlet 2 PE M16, diamètre 4 à 8 mm Cable inlet With MX 32 (24 Vdc version): Up to 8 toxic or oxygen gas detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Up to 8 explosive gas detectors at 225 m with a 0.9 mm² (AWG 18) core size cable With MX 43: 2 x M16 cable entries, outer diameter 4 to 8 mm Up to 32 detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Dimensions (LxHxW) 118x110x60 mm Materials ABS, UV and shocks resistant Ingress protection IP65 Approvals for ATEX explosive versions II 3 GD Ex nA nC IIC T4 Gc for explosimetric versions Ex tc IIIC T135°C Dc -20°C<Ta<+55°C Electromagnetic compatibility according to EN50270 Ordering Information Part Number Description OLCT10N-001 Digital transmitter OLCT 10N, range 0-100% LEL CH4 OLCT10N-003 Digital transmitter OLCT 10N, range 0-100% LEL H2 OLCT10N-004 Digital transmitter OLCT 10N, range 0-100% LEL C4 H10 OLCT10N-005 Digital transmitter OLCT 10N, range 0-100% LEL C3 H8 OLCT10N-200 Digital transmitter OLCT 10N, range 0-30% vol O2 (2 year O2 sensor) OLCT10N-272 Digital transmitter OLCT 10N, range 0-30% vol O2 (5 year O2 sensor) OLCT10N-204 Digital transmitter OLCT 10N, range 0-300 ppm CO OLCT10N-205 Digital transmitter OLCT 10N, range 0-1000 ppm CO OLCT10N-213 Digital transmitter OLCT 10N, range 0-30 ppm H2S OLCT10N-214 Digital transmitter OLCT 10N, range 0-100 ppm H2S OLCT10N-216 Digital transmitter OLCT 10N, range 0-100 ppm NO OLCT10N-217 Digital transmitter OLCT 10N, range 0-300 ppm NO OLCT10N-219 Digital transmitter OLCT 10N, range 0-10 ppm NO2 OLCT10N-220 Digital transmitter OLCT 10N, range 0-30 ppm NO2 OLCT10N-231 Digital transmitter OLCT 10N, range 0-100 ppm NH3 OLCT10N-232 Digital transmitter OLCT 10N, range 0-1000 ppm NH3 OLCT10N-252 Digital transmitter OLCT 10N, range 0-5000 ppm CO2 OLCT10N-239 Digital transmitter OLCT 10N, range 0-5% vol CO2 OLCT10N-241 Digital transmitter OLCT 10N, range 0-100% vol CO2 Product Data Sheet -
Teledyne Detcon TP-624D Hydrogen Sulfide Sensor
Model TP-624D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the ranges of of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidity performance. Model TP-624D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D). Model TP-624D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, one-man remote calibration, self-adjusting zero and span, and LED indicators for 2 alarm relays and 1 fault relay and calibration status. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty. Order Guide Specify junction box options (below) PN 966-014520-100 - TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet PN 966-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-014520-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly 316SS condulet with Hart Note above part numbers are for 0-100 ppm range. For 0-20 ppm or 0-50 ppm range replace -100 with -020 or -050 respectively. APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S sensors dating back 20 years Compatible with PLCs, SCADA, DCS, via 0-20 mA, and /or RS-485, and/ or alarm relays Sensor status ad parameters accessible via RS-485 (Modbus) Menu programmable relays standard (two alarms plus fault) Simple menu driven calibration- less than 3 minutes LED display and LED indicators for FAULT and CAL ststus Plug-in field-replaceable transmitter Response similar to electrochemical sensor:T50 <30sec., T80 <60 sec. 10 year conditional sensor warranty Direct response constant temperature control Withstands exposure to high range concentrations of H2S and other acid gases Impervious to high moisture environments in both powered and non-powered mode Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of ) Response/Clearing Time T50 <30 seconds; T80 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Electrical Classification Explosion proof CSAus Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C) ) Class I, Zone 1, Group IIB+H2 cCSA Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB+H2 ATEX Ex d IIB+H2 T4 (Tamb = -40°C to +60°C) Safety Approvals cCSAus ATEX CE Marking SIL2 FMEDA Rating Ingress Protection IP66 Warranty Plug-in detector - 10 year conditional Transmitter - 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -35°C to +55°C; -13°F to +131°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC* * 12 VDC available by special order Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) RFI/EMI Protection Complies with EN 50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Relay Outputs Alarm 1, Alarm 2, and Fault 5A @ 250VAC 5A @ 30VDC Faults Monitored Heater, Loop, Input Voltage Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet
Reviews