Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.

Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty

APPLICATIONS:

  • Oil and Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Waste Water Treatment Plants
  • Utilities

FEATURES:

  • XP-intrinsically Safe
  • Class I, Div. 1, Groups B, C & D
  • 2 Wire Loop powered
  • Field Replaceable Electrochemical Sensor
  • Non-intrusive Magnetic Interface
  • Built-in Diagnostics
  • Fully Encapsulated ITM Electronics
  • Electropolished 316SS Construction ITM
  • Quick Thread Release (for sensor replacement)
  • Integral Calibration Port
PART NUMBER GAS MEASURING ACCURACY RESPONSE TIME
961-500022-100 Ammonia 0-100 ppm ±2% FS T90≤90 seconds
961-190022-001 Arsine 0-1 ppm ±2% FS T90≤60 seconds
961-750022-005 Bromine 0-5 ppm ±2% FS T90≤60 seconds
961-EB0022-100 Butadiene 0-100 ppm ±2% FS T90≤140 seconds
961-440022-100 Carbon Monoxide 0-100 ppm ±2% FS T50≤10 sec./ T90≤30 sec.
961-740022-010 Chlorine 0-10 ppm ±2% FS T90≤60 seconds
961-760022-050 Chlorine Dioxide 700 0-50 ppm ±2% FS T90≤120 seconds
961-770022-001 Chlorine Dioxide 701 0-1 ppm ±2% FS T90≤60 seconds
961-210022-005 Diborane 0-5 ppm ±2% FS T90≤60 seconds
961-EO0022-100 Ethanol 0-100 ppm ±2% FS T90≤140 seconds
961-ED0022-100 Ethylene (*See Note 2) 0-100 ppm ±2% FS T90≤140 seconds
961-EJ0022-100 Ethylene Oxide 0-100 ppm ±2% FS T90≤140 seconds
961-270022-001 Fluorine 0-1 ppm ±2% FS T90≤80 seconds
961-EP0022-100 Formaldehyde 0-100 ppm ±2% FS T90≤140 seconds
961-250022-002 Germane 0-2 ppm ±2% FS T90≤60 seconds
961-070022-01P Hydrogen (1%) 0-1%
volume
±2% FS T90≤60 seconds
961-840022-100 Hydrogen PPM 0-100 ppm ±2% FS T90≤30 seconds
961-080022-030 Hydrogen Bromide 0-30 ppm ±2% FS T90≤70 seconds
961-090022-030 Hydrogen Chloride 0-30 ppm ±2% FS T90≤70 seconds
961-130022-030 Hydrogen Cyanide 0-30 ppm ±2% FS T90≤40 seconds
961-330022-010 Hydrogen Fluoride 0-10 ppm ±2% FS T90≤90 seconds
961-240022-100 Hydrogen Sulfide 0-100 ppm ±2% FS T50≤10 sec./ T80≤30 sec.
961-EE0022-100 Methanol 0-100 ppm ±2% FS T90≤140 seconds
961-EK0022-100 Methyl Mercaptan 0-100 ppm ±2% FS T90≤45 seconds
961-940022-100 Nitric Oxide 0-100 ppm ±2% FS T90≤10 seconds
961-640022-010 Nitrogen Dioxide 0-10 ppm ±2% FS T90≤40 seconds
961-340022-025 Oxygen 0-25%
volume
±1% FS T90≤10 seconds
961-390022-001 Ozone 0-1 ppm ±2% FS T90≤120 seconds
961-200022-005 Phosphine 0-5 ppm ±2% FS T90≤30 seconds
961-230022-050 Silane 0-50 ppm ±2% FS T90≤60 seconds
961-550022-020 Sulfur Dioxide 0-20 ppm ±2% FS T90≤20 seconds

*Note2: This product is a safety device to detect hazardous conditions, and is not intended for process control application in fruit ripening operations.

SYSTEM SPECIFICATIONS:

Sensor Type
Continuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type

Span Drift
<5% signal loss per year (in first 2 years)

Outputs
Linear 4-20 mA DC

Electrical Classification
Explosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)

Safety Approvals
cCSAus

Sensor Life/Warranty
See sensor detail table above for specific sensor warranty

ENVIRONMENTAL SPECIFICATIONS:

Operating Temperature Range
Refer to chart on prior page per gas type.

Storage Temperature Range
Refer to chart on prior page per gas type.

Operating Humidity Range
0% to 99% RH non-condensing (continuous)
0%-100% RH (intermittent)

Operating Pressure Range
Atmospheric ±10%

ACCESSORIES:

Junction Box
(aluminum with Transient Protection Terminal Board)

Loop Powered Digital Display
(Provides a Direct Display of Sensor Readings)

MECHANICAL SPECIFICATIONS:

Dimensions
7″H x 2.2″ Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11″H x 6.1″W x 3.75″D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5″; 140mm center to center

Weight
2 lbs; 0.907 kg (sensor only)
6 lbs; 2.72 kg (w/aluminum j-box)
9 lbs; 4.08 kg (w/stainless steel j-box)

ELECTRICAL SPECIFICATIONS:

Power Input
11 – 30 VDC

Power Consumption
Normal operation = 30mA @ 24V (<0.75 watt)
Maximum = 50mA @ 24V (1.2 watts)

Inrush Current
500mA @ 24V (typical)

Analog Output
Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA All Fault Diagnostics
2mA In-Calibration
4-20mA 0-100% full-scale
22mA Over-range condition

Status Indicators
Optional 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan,
Set-up Options, and Fault Reporting

Faults Monitored
Loop, Input Voltage,
Missing Sensor, Zero,
Processor, Memory, Calibration

Cable Requirements
Power/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG

Serial Output
2-wire twisted-pair with ground, shielded communication
cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor

I/O Protection
Over -voltage, Miswiring

Product Data Sheet

Reviews

There are no reviews yet.