Detcon
PE Energy is the reliable Detcon distributor in Houston TX. You can visit our store to buy extreme quality industrial equipment at reasonable prices.
Showing all 17 results
-
Teledyne Detcon DM-700 Toxic Gas Detector
Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port APPLICATIONS: Oil & Gas Chemical Plants Food & Beverage Steel Mills Pulp and Paper Refineries Wastewater Treatment Plants Utilities PART NUMBER GAS MEASURING ACCURACY RESPONSE TIME 967-12EG91-100 Acetylene 0-100 ppm ±2% FS T90≤140 seconds 967-505091-100 Ammonia 0-100 ppm ±2% FS T90≤90 seconds 967-191991-001 Arsine 0-1 ppm ±2% FS T90≤60 seconds 967-747591-005 Bromine 0-5 ppm ±2% FS T90≤60 seconds 967-12EB91-100 Butadiene 0-100 ppm ±2% FS T90≤140 seconds 967-444491-100 Carbon Monoxide 0-100 ppm ±2% FS T50≤10 sec./ T90≤30 sec. 967-747491-010 Chlorine 0-10 ppm ±2% FS T90≤60 seconds 967-747691-050 Chlorine Dioxide 700 0-50 ppm ±2% FS T90≤120 seconds 967-777791-001 Chlorine Dioxide 701 0-1 ppm ±2% FS T90≤60 seconds 967-192191-005 Diborane 0-5 ppm ±2% FS T90≤60 seconds 967-12EO91-100 Ethanol 0-100 ppm ±2% FS T90≤140 seconds 967-12ED91-100 Ethylene (*See Note 2) 0-100 ppm ±2% FS T90≤140 seconds 967-12EJ91-100 Ethylene Oxide 0-100 ppm ±2% FS T90≤140 seconds 967-272791-001 Fluorine 0-1 ppm ±2% FS T90≤80 seconds 967-12EP91-100 Formaldehyde 0-100 ppm ±2% FS T90≤140 seconds 967-232591-002 Germane 0-2 ppm ±2% FS T90≤60 seconds 967-070791-01P Hydrogen (1%) 0-1% volume ±2% FS T90≤60 seconds 967-050591-04P Hydrogen (4%) 0-4% ±2% FS T90≤60 seconds 967-848491-100 Hydrogen PPM 0-100 ppm ±2% FS T90≤30 seconds 967-090891-030 Hydrogen Bromide 0-30 ppm ±2% FS T90≤70 seconds 967-090991-030 Hydrogen Chloride 0-30 ppm ±2% FS T90≤70 seconds 967-131391-030 Hydrogen Cyanide 0-30 ppm ±2% FS T90≤40 seconds 967-333391-010 Hydrogen Fluoride 0-10 ppm ±2% FS T90≤90 seconds 967-242491-100 Hydrogen Sulfide 0-100 ppm ±2% FS T50≤10 sec./ T80≤30 sec. 967-303091-100 Hydrogen Sulfide (DC)* 0-100 ppm ±10% applied gas concentration or ±3 ppm, whichever is greater T20 ≤ 20sec 967-303091-050 T50 ≤ 45 sec 967-303091-025 T90 ≤ 60 sec 967-12EE91-100 Methanol 0-100 ppm ±2% FS T90≤140 seconds 967-12EK91-100 Methyl Mercaptan 0-100 ppm ±2% FS T90≤45 seconds 967-949491-100 Nitric Oxide 0-100 ppm ±2% FS T90≤10 seconds 967-646491-010 Nitrogen Dioxide 0-10 ppm ±2% FS T90≤40 seconds 967-341520-025 Oxygen 0-25% volume ±1% FS T90≤10 seconds 967-393991-001 Ozone 0-1 ppm ±2% FS T90≤120 seconds 967-192091-005 Phosphine 0-5 ppm ±2% FS T90≤30 seconds 967-232391-050 Silane 0-50 ppm ±2% FS T90≤60 seconds 967-555591-020 Sulfur Dioxide 0-20 ppm ±2% FS T90≤20 seconds *Note: Acetylene can only be used with a Group A enclosure. *Note2: This product is a safety device to detect hazardous conditions, and is not intended for process control application in fruit ripening operations. *Note3: DC=Desert Climate Sensors are 3rd-party test report to ISA 92.00.01 2010 standard SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption 3-electrode electrochemical cell Plug-in field replaceable Intelligent Type Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CCSAUS Class I, Division 1, Groups B, C, D () Class I, Zone 1, Group IIC ATEX II 2 G Ex d ib IIB + H2 T4 GB Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUS ATEX CE Marking SIL2 Certified to IEC 61508 MECHANICAL SPECIFICATIONS: Dimensions 7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5"; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11 - 30 VDC Power Consumption Normal operation = 30mA @ 24V (<0.75 watt) Maximum = 50mA @ 24V (1.2 watts) Inrush Current 500mA @ 24V (typical) RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600, N, 8, 1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over -voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon DM-700-O2 Oxygen Sensor
Model DM-700-O2 is a non-intrusive "Smart" sensor designed to detect and monitor Oxygen in air over the range of 0-25% by volume using electrochemical sensor technology. The plug-in, field replaceable sensor cell is temperature compensated and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), and HART. Detcon’s oxygen sensors have a long shelf life and are supported by an industry-leading warranty. Order Guide Specify junction box options (below) PN 967-343490-25P_ - DM-700-O2 Sensor Assembly (no junction box) PN 967-343491-25P_ - DM-700-O2 Sensor Assembly with Aluminum J-Box PN 967-343494-25P_ - DM-700-O2 Sensor Assembly with 316 SS J-Box APPLICATIONS: Petrochemical Refineries Chemical plants Confined Space Monitoring Analyzer Shelters Wastewater treatment plants Wet wells-dry wells Pulp and paper Food and beverage Utilities FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption 3-electrode electrochemical cell Plug-in field replaceable Intelligent Type Sensor Life 2 1/2 to 3 years typical Measurement Range 0-25% Oxygen by volume Accuracy/Repeatability ±1% FS Response/Clearing Time T90 ≤ 10 seconds Span Drift <5% of signal per year (in first two years) Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C) Class I, Zone 1, Group IIC ATEX II 2 G Ex d ib IIB + H2 T4 Gb (Tamb = -40°C to +50°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUSA ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in Cell - 2 years; Transmitter - 2 Years Environmental Specifications Operating Temperature Range -40°F to +122°F; -40°C to +50°C Storage Temperature Range -40°F to +122°F; -40°C to +50°C Operating Humidity Range 0-99% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/ aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 30mA (<0.75 watt) Maximum = 50mA (1.2 watts) Inrush Current 1.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Wireless Integration Module (Detcon Model RXT-320 SmartWireless® Transceivers) Product Data Sheet -
Teledyne Detcon FP-524D Combustible Gas Sensor
Model FP-524D is a "Smart" gas detection sensor designed to detect and monitor combustible gas in air over the range of 0-100% LEL (lower explosive limit) using matched-pair catalytic bead technology. Model FP-524D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon matched-pair catalytic bead sensors dating back more than 20 years. The sensor assembly includes the detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups C and D). Model FP-524D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault and calibration status. A HART communications option is also available. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty Order Guide PN 965-525420-100 - Model FP-524D in Aluminum Junction Box PN 965-52542B-100 - Model FP-524D-316SS in Stainless Steel Junction Box PN 9H5-525420-100 - Model FP-524D with HART in Aluminum Junction Box PN 9H5-52542B-100 - Model FP-524D-316SS with HART in Stainless Steel Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Certified to ISA performance standards cCSAus approved for for Class I, Division 1, Groups C & D Transmitter design fits all existing Detcon Catalytic Bead Sensors dating back 20 years Simple menu driven calibration - less than 3 minutes LED display and LED indicators for FAULT and CAL status Plug-in field-replaceable transmitter Long sensor life: average +5 years in harsh offshore drilling/production environments High resistance to poisons such as sulfides, chlorides, silicon-based contaminants etc. Low power consumption (less than 3.5 watts versus 8+ watts on competitive brands) Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Matched-pair catalytic bead Sensor Life 3 to 5 years typical Measurement Range 0-100% LEL (lower explosive limit) Accuracy/Repeatability ±3% 0-50% LEL ±5% 50-100% LEL Response/Clearing Time T50 <10 seconds; T90 <30 seconds Zero Drift <5% per year Outputs Linear 4-20 mA DC HART (optional) Electrical Classification Explosion proof CSAus Class I, Division 1, Groups C, D (Tamb = -25°C to +40°C) Class I, Zone 1, Group IIB cCSA Class I, Division 1, Groups C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB Performance Approvals CSA C22.2 #152-M1984, ISA 12.13.01-2003 Safety Approvals cCSAus Ingress Protection NEMA 4X, IP66 Warranty Sensor: 2 year warranty Transmitter: 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -40°C to +75°C; -40°F to +167°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10"H (including splashguard) x 6.1"W x 4.3"D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5"; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 87mA (2 watts) RFI/EMI Protection Complies with ISO 92.0.01 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators 4-digital LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Faults Monitored Loop, Input Voltage, Zero Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon FP-624D Combustible Gas Sensor
Model FP-624D is a “Smart” gas detection sensor designed to detect and monitor combustible gas in air over the range of 0-100% LEL (lower explosive limit) using matched-pair catalytic bead technology. Model FP-624D features Detcon’s MicroSafeTM intelligent electronics, nonintrusiveoperator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon matched-pair catalytic bead sensors dating back more than 20 years. The sensor assembly includes the detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups C & D). Model FP-624D is equiped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, 2 alarm relays and 1 fault relay, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault, alarm, and calibration status. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty. Order Guide Specify junction box options (below) PN 966-524520-100 - Model FP-624D in Aluminum Junction Box PN 966-52452B-100 - Model FP-624D-316SS in Stainless Steel Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Performance Certified to CSA 152 cCSAus for Class I, Division 1, Groups C & D Transmitter design fits all existing Detcon Catalytic Bead Sensors dating back 20 years Compatible with PLCs, SCADA, DCS, via 4-20 mA, and/or RS485, and/or alarm relays Sensor status and parameters accessible via RS-485 (Modbus™) Menu programmable relays standard (two alarms plus fault) Simple menu driven calibration - less than 3 minutes LED display and LED indicators for FAULT and CAL status Plug-in field-replaceable transmitter Long sensor life: averaging +5 years in harsh offshore drilling/production environments High resistance to poisons such as sulfides, chlorides, silicon-based contaminants etc. Low power consumption (less than 3.5 watts versus 8+ watts on competitive brands) Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Matched-pair catalytic bead Sensor Life 3 to 5 years typical Measurement Range 0-100% LEL (lower explosive limit) Accuracy/Repeatability ±3% 0-50% LEL ±5% 50-100% LEL Response/Clearing Time T50 <10 seconds; T90 <30 seconds Zero Drift <5% per year Outputs Linear 4-20 mA DC HART (optional) 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Electrical Classification Explosion proof CSAus Class I, Division 1, Groups C, D (Tamb = -25°C to +40°C) Class I, Zone 1, Group IIB cCSA Class I, Division 1, Groups C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB Performance Approvals CSA C22.2 #152 Safety Approvals cCSAus Ingress Protection NEMA 4X, IP66 Warranty Sensor: 2 year warranty Transmitter: 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -40°C to +75°C; -40°F to +167°F Operating Humidity Range 0-99% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12 - 28 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 87mA (2 watts) RFI/EMI Protection Complies with ISO 92.0.01 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators 4-digital LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Relay Outputs Alarm 1, Alarm 2, and Fault 5A @ 250VAC 5A @ 30VDC Faults Monitored Loop, Input Voltage, Zero Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon FP-700 Combustible Gas Sensor
Model FP-700 is a non-intrusive "Smart" sensor designed to detect and monitor combustible gases in air over the range of 0-100% LEL using catalytic bead sensor technology. The plug-in, field replaceable detector is poison-resistant and features over-sized gold-plated connections that help prevent corrosion. The FP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model FP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model FP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), and HART. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty. Order Guide Specify junction box options (below) PN 967-525520-100 - FP-700 Sensor Assembly (no junction box) PN 967-521520-100 - FP-700 Sensor Assembly with Aluminum Junction Box PN 967-524520-100 - FP-700 Sensor Assembly with 316 SS Junction Box PN 9H7-521520-100 - FP-700 Sensor Assembly with HART in Aluminum Junction Box PN 9H7-524520-100 - FP-700 Sensor Assembly with HART in 316 SS Junction Box PN 9R7-524520-100 - FP-700 Sensor Assembly with RAM in Aluminum Junction Box PN 9R7-524520-100 - FP-700 Sensor Assembly with HART in 316SS Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Matched-pair catalytic bead detector Plug-in field replaceable Sensor Life 3 to 5 years typical Measurement Range 0-100% LEL (lower explosive limit) Accuracy/Repeatability ±3% 0-50% LEL; ±5% 50-100% LEL Response/Clearing Time T50 <10 seconds; T90 <30 seconds Zero Drift <5% per year Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CCSAUS Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSUS Performance to ANSI/ISA 60079-29-1 (12.13.01)-2013 and CSA 22.2 #152 ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in detector - 2 years Transmitter - 2 Years Environmental Specifications Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-99% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 1.0A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Operating Temperature, Loop, Input Voltage, Bridge Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Wireless Integration Module (Detcon Model RXT-320 SmartWireless® Transceivers Product Data Sheet -
Teledyne Detcon IR-700-CH Combustible Gas Sensor
Model IR-700-CH is a non-intrusive “Smart” sensor designed to detect and monitor combustible hydrocarbon gases in air over the range of 0-100% LEL using miniature non-dispersive Infrared Optical (NDIR) sensor technology. As compared to catalytic bead sensors, with NDIR there is no risk of sensor poisoning, no risk of high concentration saturation, and no need for O2 to be present. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The IR-700-CH’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CH is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR-700-CH is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 5-year warranty. Order Guide Specify junction box options (below) PN 967-215520-100 - IR-700-CH Sensor Assembly (no junction box) PN 967-211520-100 - IR-700-CH Sensor Assembly with Aluminum Junction Box PN 967-214520-100 - IR-700-CH Sensor Assembly with 316 SS Junction Box PN 9H7-211520-100 - IR-700-CH Sensor Assembly with HART, Alumium Junction Box PN 9H7-214520-100 - IR-700-CH Sensor Assembly with HART, 316 SS Junction Box PN 9R7-211520-100 - IR-700-CH Sensor Assembly with RAM, Aluminum Junction Box PN 9R7-214520-100 - IR-700-CH Sensor Assembly with RAM, 316 SS Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants GAS DETECTED: Methane Ethane Propane Butane Pentane Hexane Ethylene Gasoline Vapor Diesel Fuel Vapor Jet Fuel Vapor For other gases consult the factory FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Non-dispersive Infrared Optical (NDIR) - Combustible Gas Sub-miniature plug-in field replaceable Sensor Life 5 years typical Measurement Range 0-100% LEL (lower explosive limit) 0-100% by volume Accuracy ±2% F.S. (0-50% LEL) Repeatability ±2% F.S. Response Time* T50 < 6 seconds, T90 < 10 seconds Zero Drift (typical) ≤2% per 2 years Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUS Performance to ISA 12.13.01-2000 and CSA 22.2 #152 ATEX CE Marking SIL2 Certified to IEC 61508 (ATEX version only) Warranty Plug-in detector - 5 years Transmitter - 2 Years * As tested with 1 lpm flowrate ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 0.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) HART Integration Module (HART Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon IR-700-CO2 Carbon Dioxide Sensor
Model IR-700-CO2 is a non-intrusive “Smart” sensor designed to detect and monitor carbon dioxide gas in air using miniature non-dispersive Infrared Optical (NDIR) sensor technology. Available in a low and a high range version, ranges of detection (by volume) are 0-0.3%, 0-1%, 0-3%, 0-5% (low range version) and 0-10%, 0-25%, 0-50%, and 0-100% (high range version). The plug-in, field replaceable detector provides a selective response to CO2 and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CO2 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR700-CO2 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Additional integration options include a Remote Alarm Module (RAM) & HART. Detcon’s carbon dioxide gas sensor has an infinite shelf life and is supported by a 5-year pro-rated warranty. Order Guide Specify junction box options (below) PN 967-405520-005 - IR-700-CO2 (5% Range) Sensor Assembly (no J-box) PN 967-401520-005 - IR-700-CO2 (5% Range) Sensor Assembly with Aluminum J-Box PN 967-404520-005 - IR-700-CO2 (5% Range) Sensor Assembly with 316 SS J-Box PN 967-425520-025 - IR-700-CO2 (25% Range) Sensor Assembly (no J-box) PN 967-421520-025 - IR-700-CO2 (25% Range) Sensor Assembly with Aluminum J-Box PN 967-424520-025 - IR-700-CO2 (25% Range) Sensor Assembly with 316 SS J-Box APPLICATIONS: Chemicals Pesticides Agriculture & Horticulture Food & Beverage Bottling Plants Sewer Entry Waste Water Treatment Plants Coal Gasification Pulp & Paper Mills Enhanced Oil Recovery FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry I/O Protection Water-Resistant, Corrosion-Resistant, Vibration-Resistant Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Non-dispersive Infrared Optical (NDIR) - CO2 Sub-miniature plug-in field replaceable Sensor Life 5 years typical Measurement Range (% by volume) 0-0.3, 0-0.5, 0-1, 0-3, 0-5 (low range version) 0-10, 0-15, 0-20, 0-25, 0-50, 0-100 (high range version) Accuracy/Repeatability ±5% of range Response Time T50 < 15 seconds, T90 < 40 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus ATEX CE Marking Warranty Plug-in detector - 5 year pro-rated Transmitter - 2 Years ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 0.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon Model 100 Toxic Gas Sensor
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality. Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty APPLICATIONS: Oil and Gas Chemical Plants Food and Beverage Steel Mills Pulp and Paper Refineries Waste Water Treatment Plants Utilities FEATURES: XP-intrinsically Safe Class I, Div. 1, Groups B, C & D 2 Wire Loop powered Field Replaceable Electrochemical Sensor Non-intrusive Magnetic Interface Built-in Diagnostics Fully Encapsulated ITM Electronics Electropolished 316SS Construction ITM Quick Thread Release (for sensor replacement) Integral Calibration Port PART NUMBER GAS MEASURING ACCURACY RESPONSE TIME 961-500022-100 Ammonia 0-100 ppm ±2% FS T90≤90 seconds 961-190022-001 Arsine 0-1 ppm ±2% FS T90≤60 seconds 961-750022-005 Bromine 0-5 ppm ±2% FS T90≤60 seconds 961-EB0022-100 Butadiene 0-100 ppm ±2% FS T90≤140 seconds 961-440022-100 Carbon Monoxide 0-100 ppm ±2% FS T50≤10 sec./ T90≤30 sec. 961-740022-010 Chlorine 0-10 ppm ±2% FS T90≤60 seconds 961-760022-050 Chlorine Dioxide 700 0-50 ppm ±2% FS T90≤120 seconds 961-770022-001 Chlorine Dioxide 701 0-1 ppm ±2% FS T90≤60 seconds 961-210022-005 Diborane 0-5 ppm ±2% FS T90≤60 seconds 961-EO0022-100 Ethanol 0-100 ppm ±2% FS T90≤140 seconds 961-ED0022-100 Ethylene (*See Note 2) 0-100 ppm ±2% FS T90≤140 seconds 961-EJ0022-100 Ethylene Oxide 0-100 ppm ±2% FS T90≤140 seconds 961-270022-001 Fluorine 0-1 ppm ±2% FS T90≤80 seconds 961-EP0022-100 Formaldehyde 0-100 ppm ±2% FS T90≤140 seconds 961-250022-002 Germane 0-2 ppm ±2% FS T90≤60 seconds 961-070022-01P Hydrogen (1%) 0-1% volume ±2% FS T90≤60 seconds 961-840022-100 Hydrogen PPM 0-100 ppm ±2% FS T90≤30 seconds 961-080022-030 Hydrogen Bromide 0-30 ppm ±2% FS T90≤70 seconds 961-090022-030 Hydrogen Chloride 0-30 ppm ±2% FS T90≤70 seconds 961-130022-030 Hydrogen Cyanide 0-30 ppm ±2% FS T90≤40 seconds 961-330022-010 Hydrogen Fluoride 0-10 ppm ±2% FS T90≤90 seconds 961-240022-100 Hydrogen Sulfide 0-100 ppm ±2% FS T50≤10 sec./ T80≤30 sec. 961-EE0022-100 Methanol 0-100 ppm ±2% FS T90≤140 seconds 961-EK0022-100 Methyl Mercaptan 0-100 ppm ±2% FS T90≤45 seconds 961-940022-100 Nitric Oxide 0-100 ppm ±2% FS T90≤10 seconds 961-640022-010 Nitrogen Dioxide 0-10 ppm ±2% FS T90≤40 seconds 961-340022-025 Oxygen 0-25% volume ±1% FS T90≤10 seconds 961-390022-001 Ozone 0-1 ppm ±2% FS T90≤120 seconds 961-200022-005 Phosphine 0-5 ppm ±2% FS T90≤30 seconds 961-230022-050 Silane 0-50 ppm ±2% FS T90≤60 seconds 961-550022-020 Sulfur Dioxide 0-20 ppm ±2% FS T90≤20 seconds *Note2: This product is a safety device to detect hazardous conditions, and is not intended for process control application in fruit ripening operations. SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption 2-electrode electrochemical cell Plug-in field replaceable Type Span Drift <5% signal loss per year (in first 2 years) Outputs Linear 4-20 mA DC Electrical Classification Explosion proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C) Safety Approvals cCSAus Sensor Life/Warranty See sensor detail table above for specific sensor warranty ENVIRONMENTAL SPECIFICATIONS: Operating Temperature Range Refer to chart on prior page per gas type. Storage Temperature Range Refer to chart on prior page per gas type. Operating Humidity Range 0% to 99% RH non-condensing (continuous) 0%-100% RH (intermittent) Operating Pressure Range Atmospheric ±10% ACCESSORIES: Junction Box (aluminum with Transient Protection Terminal Board) Loop Powered Digital Display (Provides a Direct Display of Sensor Readings) MECHANICAL SPECIFICATIONS: Dimensions 7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5"; 140mm center to center Weight 2 lbs; 0.907 kg (sensor only) 6 lbs; 2.72 kg (w/aluminum j-box) 9 lbs; 4.08 kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11 - 30 VDC Power Consumption Normal operation = 30mA @ 24V (<0.75 watt) Maximum = 50mA @ 24V (1.2 watts) Inrush Current 500mA @ 24V (typical) Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators Optional 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over -voltage, Miswiring Product Data Sheet -
Teledyne Detcon Model 1000 Carbon Dioxide Analyzer
Detcon Model 1000-CO2 Analyzer is designed to provide continuous, accurate, real-time measurement of carbon dioxide gas concentrations in a wide variety of process gas streams. Available ranges are from 0-1.0% up to 0-15.0%. All CO2 analyzers in the Model 1000 Series employ Detcon’s sub-miniature NDIR optical sensor element and feature a microprocessor-based signal-conditioning transmitter with local digital display, fault supervision, calibration mode indicator, 4-20mA, alarm relays and an RS-485 serial port. The instrument package is rated for Non-Hazardous areas. APPLICATIONS: Continuous Measurement with Superior Uptime Readily Field Replaceable Sensors Simple Operation and Field Calibraton Standard Outputs: 4-20 mA, RS-485, 3 Relays FEATURES: Ranges from 1%, 3%, 5% and 15% by Volume Readily Field Replaceable Sensors Simple Operation and Field Calibraton Standard Outputs: 4-20 mA, RS-485, 3 Relays Non-Hazardous area rated Sensor Type Non-dispersive Infrared Measurement Range - High Range 0-1.0/3.0/5.0/15.0% Accuracy/Repeatability The greater of: ±10% of reading or ±2.5% of range Response/Clearing Time T50 <30 seconds T80 <60 seconds Operating Temperature Range -40°F to +167°F; -40°C to +75°C Operating Pressure Requirements Inlet: 10 ±2 psig Vent: Atmospheric ±1 psig Outputs Linear 4-20 mA DC RS-485 Modbus™ 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Power Input 117/220 VAC 18-36 VDC Electrical Classification Non-Hazardous areas Warranty Sensor: 2 years Transmitter: 2 years Analyzer Weight 80 lbs. Shipping Weight 140 lbs Dimensions 29” x 29” x 8” Product Data Sheet -
Teledyne Detcon Model 1000 Hydrogen Sulfide Analyzer
Model 1000-H2S Analyzer is designed to provide continuous, accurate, real-time measurement of hydrogen sulfide gas concentrations in a wide variety of process gas streams. With new technology and design, the Process Analyzer has a measurement range of 0-500 ppm. All H2 S analyzers in the Model 1000 Series employ Detcon’s 3-Electrode Electrochemical sensor element and feature a microprocessor-based signal-conditioning transmitter with local digital display, fault supervision, calibration mode indicator, 4-20mA, alarm relays and an RS-485 serial port. The lowest range for this unit is 0-10 ppm. The instrument package is rated for Non-Hazardous areas. APPLICATIONS: Gas Well Testing & Analysis Gas Well Production Sites Gas Treatment Plants Gas Transmission Custody Transfer Compliance FEATURES: Continuous Measurement with Superior Uptime Ranges from 0-500 ppm Readily Field Replaceable Sensors Simple Operation and Field Calibraton Standard Outputs: 4-20 mA, RS-485, 3 Relays Non-Hazardous Areas rated Sensor Type 3-Electrode Electrochemical Measurement Range Low Range 0-10/20/50/100/150/250/500 ppm Accuracy/Repeatability ±10% of reading or ±2.5% of range whichever is greater Response/Clearing Time T50 <30 seconds T90 <1 minute Max output to over-range gas: <10 seconds Operating Temperature Range -40°F to +122°F; -40°C to +50°C Operating Pressure Requirements Inlet: 10 ±2 psig Vent: Atmospheric ±1 psig Outputs Linear 4-20 mA DC RS-485 Modbus™ 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Power Input 117/220 VAC 18-36 VDC Electrical Classification Non-Hazardous Areas Warranty Sensor: 6 months Transmitter: 2 year Analyzer Weight 80 lbs. Shipping Weight 140 lbs Dimensions 29" x 29" x 8" Product Data Sheet -
Teledyne Detcon Model X40 Integrated Alarm And Control System
Model X40 is a low power alarm and control system designed to monitor multiple gas detection sensors and/or a wide range of other field devices. The versatile control system is designed to receive and supervise inputs using either 4-20mA DC or Serial RS-485 Modbus™ and is available in two packages: Model X40-8 and Model X40-32. Both packages function as a Modbus™ Master and can be customized and expanded based on individual application needs using the stackable din-rail mounted I/O modules. All I/O modules are individually addressable and operate on 11.5-30VDC. The X40-8 provides power for up to eight field devices and can house up to six 4-channel I/O modules. The Model X40-32 provides power for up to 32 field devices and can house up to 12 4-channel I/O modules. The I/O modules available for use with the Model X40 include a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). The modules can be mounted within the main system enclosure or installed remotely to simplify field wiring. The Model X40 is completely field programmable using a small handheld magnet and offers advanced technology with intuitive, embedded intelligence. The control system displays real-time readings and field device status on a backlit LCD screen. During normal operation, the screen displays the alarm status and current reading (i.e., channel number, gas type, and gas concentration) for up to eight field devices simultaneously. The display is sequential and during normal operation it auto cycles through each of the active channel screens. Among the system’s unique features is a wireless option that can be used with RXT-320 SmartWireless® transceivers. Enclosure options include: NEMA 4X, NEMA 1 panel mount, and NEMA 7. Features 8 to 32 channel capacity Backlit LCD screen display Analog or RS-485 input options Easy intuitive field configuration Wire or distributed I/O Extensive event data logging SmartWireless® capable Applications Oil and gas drilling rigs Oil and gas production sites Offshore production platforms Wastewater treatment plants Food and beverage processing Pulp and paper mills Refining and petrochemical SYSTEM SPECIFICATIONS System Capacity Model X40-32-N1P: Up to 32 field devices Model X40-8-N4X: Up to 8 field devices Model X40-32-N4X: Up to 32 field devices Model X40-32-N7: Up to 32 field devices (analog or serial) Indicators 1 1/8” by 5 3/4” backlit LCD Alarm status LEDs Display Accuracy ±1% of full scale value Input Options Analog 4-20 mA DC RS-485 Modbus™ *(Only compatible with other Detcon products) Relay Contacts Output Options 4-20 mA DC RS-485 Modbus™ Relay Contacts Safety Approvals CE Marking (Models X40-N4X & X40-SS) Warranty One Year ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -4ºF to + 158ºF, -20ºC to + 70ºC Storage Temperature Range -40ºF to + 185ºF, -40ºC to + 85ºC Operating Humidity Range 0-99% RH non-condensing MECHANICAL SPECIFICATIONS Dimensions Model X40-32-N1P: 10.5”W x 8”H x 12”D Model X40-8-N4X: 12”W x 14”H x 7.75”D Model X40-32-N4X: 16”W x 17.85”H x 9.5”D Model X40-32-N7: 11”W x 9.15”H x 2.75”D Weight Model X40-32-N1P: 10 lbs Model X40-8-N4X: 10 lbs Model X40-32-N4X: 20 lbs Model X40-32-N7: 10 lbs ELECTRICAL OPTIONS Power Input 115-230 VAC* or 11.5-30 VDC * Option for Model X40-32-N7 Power Consumption <0.25 Watt (I/O module power consumption not included) (Field device power consumption not included) Electrical Classification Model X40-32-N1P: NEMA 1 Panel Mount Model X40-8-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N7: NEMA 7 Class I; Division 1, Group C, D Order Guide PN 95P-X32000-000 Model X40-32-N1P, General purpose panel mount hardware assembly 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 954-X08000-000 Model X40-8-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 8 active channels). PN 954-X32000-000 Model X40-32-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 957-X32000-000 Model X40-32-N7, Div 1 weatherproof enclosure 24 VDC power* for use in distributed I/O installations only (up to 32 active channels). Product Data Sheet -
Teledyne Detcon OLCT 700 / 710 Fixed Gas Detection
Model Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% encapsulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The gas detector sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Model Series OLCT 700/710 intelligent sensor modules feature dual outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output. It is becoming increasingly important that safety systems meet the Safety Integrity Level (SIL) requirements of IEC 61508 and IEC 61511. The SIL rating can only be determined by considering the complete safety system. FEATURES: 316 SS Construction IP 66 Multi-Layer Surge Protection SIL2 Certified Environmentally Bulletproof Series OLCT 700/710 The SERIES OLCT 700/710 sensor modules are designed with this in mind and feature a new and unmatched level of pre-emptive fault diagnostics. Application variables like input voltage range, operating temperature range, maintenance schedule, detector reliability and output integrity are all monitored and reported via the 4-20 mA and RS-485 serial output. As a component of a SIL rated system, the Safe Failure Fraction (SFF) of SERIES OLCT 700/710 sensors are designed to meet the requirements for any SIL 2 rated system. SERIES OLCT 700's sensors utilize distinctive gas detection technologies to satisfy a wide range of industrial applications that require monitoring of, toxic and flammable gases. Sensors for Hydrogen Sulfide CHEMFET MOS Solid State Technology Harsh and Extreme Locations Wide Temperature & Humidity Range 5-year Sensor Warranty Sensors for Combustible Gas Catalytic Technology Non-selective Combustible Gas Sensor 2-year Sensor Warranty Rugged Construction Infrared Technology Combustible Hydrocarbon Gas Sensor 2-year Sensor Warranty Sensors for Carbon Dioxide Infrared Technology Selective CO2 Gas Sensor 2-year Sensor Warranty Scrolling Full Message/Text Display ANATOMY of the OLCT 700/710 SPECIFICATIONS: Combustible Hydrocarbon & Carbon Dioxide Gas Detectors Model OLCT 700/710 IR Gas Combustible Hydrocarbons or CO2 Range 0-100 % LEL* or 0-5% vol.* CO2 Temperature -40°C to +75°C Warranty 2 years on electronics, 2 years on sensor *Standard Range Hydrogen Sulfide Gas Detector (solid state metal oxide semiconductor) Model OLCT 700/710 TP Gas / Symbol Hydrogen Sulfide/H2S Range 0-20 ppm, 0-50 ppm, 0-100 ppm*, 0-200 ppm Temperature -40°C to +75°C Warranty 2 years on electronics, 5 years on sensor Combustible Gas Detector (matched pair catalytic bead) Model OLCT 700/710 FP Gas / Symbol Combustible Gas Range 0-100 % LEL Temperature -40°C to +75°C Warranty 2 years on electronics, 2 years on sensor OLCT 700 OLCT 710 Input Voltage 11.5 - 28 VDC standard Power Consumption < 2 watts typical Outputs Linear 4-20 mA DC RS - 485 ModbusTM RTU Dimensions 178mm (7") Height x 65mm (2.2") Ø 349mm (13.74") Height x 127 mm (5") Width x 130 mm (5.12") Depth Weight 1.14 kg (2.5 lbs) Aluminun 3,36 kg (7.40 lbs) Stainless steel version 7.44 kg (16.40 lbs) Approvals ATEX II 2G Ex d IIB+H2 T4 Gb Functional Safety SIL2 as per IEC 61508 (except CO2) Performance Approvals OLCT 700 IR, OLCT 700 FP to ISA 12.13, CSA #152 Accuracy / Repeatability OLCT 700/710 FP and IR: ±3% LEL 0-50% LEL; ±5% LEL 50-100% LEL OLCT 700 TP: ±10% of reading or ±2 ppm (greater of) OLCT 700 IR-CO2 : ±5% full scale Response / Clearing Time OLCT 700/710 FP and IR-CH: T50 <10 s; T90 <30s (respectively 6s and 10s as tested with 1 LPM flow rate) OLCT 700 TP: T50 <30 s; T80 <60 s OLCT 700 IR-CO2 : T50 <15 s; T90 <40 s Operating Humidity Range (Continuous) OLCT 700 FP: 0-99% RH non-condensing OLCT 700 TP: 15-100% RH non-condensing OLCT 700 IR: 0-99% RH non-condensing Product Data Sheet -
Teledyne Detcon PI-700 Universal VOC Gas Sensor
Model PI-700 is a non-intrusive “Smart” sensor that use photo-ionization detector technology to monitor VOC gases over ranges from 0-10 ppm to 0-5,000 ppm. In the PI-700 sensor design, Detcon has successfully converted the sensitive laboratory style PID technology into a rugged, environmentally insensitive, and long-life industrial gas sensor. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The PI-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model PI-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model PI-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s PID sensors have a long shelf life and are supported by an industry leading warranty. Order Guide Specify junction box options (below) PN 967-P15520-010 - PI-700-VOC Sensor Assembly (no junction box) PN 967-P11520-010 - PI-700-VOC Sensor Assembly with Aluminum Junction Box PN 967-P14520-010 - PI-700-VOC Sensor Assembly with 316 SS Junction Box PN 967-P25520-01K - PI-701-VOC Sensor Assembly (no junction box) PN 967-P21520-01K - PI-701-VOC Sensor Assembly with Aluminum Junction Box PN 967-P24520-01K - PI-701-VOC Sensor Assembly with 316 SS Junction Box PN 967-P15520-0X5 - PI-700-VOC Special Low Range Sensor Assembly with 316 SS Junction Box APPLICATIONS: Pharmaceutical industry Power plants Chemical industry Air quality Refineries and petrochemical plants Solvent recovery systems Waste water treatment plants Marine and off-shore oil wells Pulp and paper industry Painting and coating operations FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-Proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Photo Ionization Detector (PID) Plug-in replaceable intelligent type (with replacement lamp) Sensor Life 2 years typical Measurement Range Gas Dependent, ranges as low as 0-10 ppm or as high as 0-5,000ppm (consult Detcon) Accuracy/Repeatability ±10% of reading or ±2% of range (greater of ) Response Time T50 <30 seconds; T90 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -20°C to +50°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d ib IIB + H2 T4 Gb (Tamb = -20°C to +50°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus ATEX CE Marking Warranty PLUG-IN DETECTOR - 1 YEAR TRANSMITTER - 2 YEARS ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -4°F to +122°F; -20°C to +50°C Storage Temperature Range -4°F to +122°F; -20°C to +50°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Maximum = 65mA (1.6 watts) Inrush Current 1.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Missing Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon Remote/Alarm Module
The Remote Sensor/Alarm Relay Module (known as the Remote/Alarm Module or RAM) is sold separately as an accessory for Model 700 and 100 Series gas sensors. It is a universal design and can be used with any of the Model 700 or 100 gas sensors. The RAM is provided in an explosion-proof junction box constructed of either epoxy-painted aluminum or 316 stainless steel, and includes a glass-viewing window. The RAM has two main functions. The first function is used to set gas alarm levels and to configure the three local relay contacts. The second function is used to operate a the gas sensor remotely. The remote sensor function is typically used when the sensor must be mounted in a position where it cannot be viewed or accessed readily. Both functions can be used at the same time. The RAM provides the 4-20 mA output directly from the gas sensor (Model 700 only). The RAM acts as a Modbus™ master to the gas sensor in order to display the reading and execute the remote control functions. It acts as a Modbus™ slave to any master control device and simply repeats the Modbus™ output from the gas sensor it is connected to. Order Guide PN 975-70000A-00A - Remote/Alarm Module in Aluminum Enclosure PN 975-70000A-00S - Remote/Alarm Module in 316 SS Enclosure SPECIFICATIONS: Inputs Model 100 or 700 Gas Sensor Outputs 4-20mA signal (Model 700 only) RS-485 Modbus™ Relay Contacts - Three Form C Rated 5A @ 30 VDC/250 VAC Input Voltage 11-30VDC Power Consumption* < 0.5 Watts at 24VDC (Normal) <1.5 watt at 24VDC (Maximum) * Excluding Gas Sensor Operating Temperature -40°C to 70°C Electrical Classification Class I, Division 1 Groups BCD Class I, Zone 1, Group IIC Ex d IIb +H2 T4 Gb cCSAus DEKRA 15ATEX0025 X FEATURES Mimics Gas Sensor Display emote calibration of Gas Sensor Remote setting capability Complete Diagnostic Information RS-485 Connection to Sensor Module 2 Alarm Relays & 1 Fault Relay Product Data Sheet -
Teledyne Detcon TP-524D Hydrogen Sulfide Sensor
Model TP-524D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the ranges of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidityperformance. Model TP-524D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D). Model TP-524D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, self-adjusting zero and span, and LED indicators for fault and calibration status. A HART communications option is also available. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty Order Guide Specify junction box options (below) PN 965-015420-100 - Model TP-524D in Aluminum Junction Box PN 965-01542B-100 - Model TP-524D-316SS in Stainless Steel Junction Box PN 9H5-015420-100 - Model TP-524D with HART in Aluminum Junction Box PN 9H5-01542B-100 - Model TP-524D-316SS with HART in Stainless Steel Junction Box Note above part numbers are for 0-100 ppm range. For 0-20 ppm or 0-50 ppm range replace -100 with -020 or -050 respectively APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S Sensors dating back 20 years Simple menu driven calibration - less than 3 minutes LED display and LED indicators for FAULT and CAL status Plug-in field-replaceable transmitter Response similar to electrochemical sensors: T-50 <30 sec., T-90 <60 sec. 10 year conditional sensor warranty Direct response constant temperature control Withstands exposure to high range concentrations of H2S and other acid gases Impervious to high moisture environments in both powered and non-powered mode Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of ) Response/Clearing Time T50 <30 seconds; T90 <60 seconds Outputs Linear 4-20 mA DC HART (optional) Electrical Classification Explosion proof CSAus Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C) ) Class I, Zone 1, Group IIB+H2 cCSA Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB+H2 FM Class I, Division 1, Groups B, C, D (Tamb = -40°C to +60°C) Complies with ANSI/ISA 92.00.01-2010 ATEX Ex d IIB+H2 T4 (Tamb = -40°C to +60°C) Ingress Protection NEMA 4X, IP66 Warranty Plug-in detector - 10 year conditional Transmitter - 2 year ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -35°C to +55°C; -13°F to +131°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) RFI/EMI Protection Complies with EN 50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting LEDs for Fault and Calibration Faults Monitored Heater, Loop, Input Voltage Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon TP-624D Hydrogen Sulfide Sensor
Model TP-624D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the ranges of of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidity performance. Model TP-624D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D). Model TP-624D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, one-man remote calibration, self-adjusting zero and span, and LED indicators for 2 alarm relays and 1 fault relay and calibration status. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty. Order Guide Specify junction box options (below) PN 966-014520-100 - TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet PN 966-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-014520-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly 316SS condulet with Hart Note above part numbers are for 0-100 ppm range. For 0-20 ppm or 0-50 ppm range replace -100 with -020 or -050 respectively. APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S sensors dating back 20 years Compatible with PLCs, SCADA, DCS, via 0-20 mA, and /or RS-485, and/ or alarm relays Sensor status ad parameters accessible via RS-485 (Modbus) Menu programmable relays standard (two alarms plus fault) Simple menu driven calibration- less than 3 minutes LED display and LED indicators for FAULT and CAL ststus Plug-in field-replaceable transmitter Response similar to electrochemical sensor:T50 <30sec., T80 <60 sec. 10 year conditional sensor warranty Direct response constant temperature control Withstands exposure to high range concentrations of H2S and other acid gases Impervious to high moisture environments in both powered and non-powered mode Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of ) Response/Clearing Time T50 <30 seconds; T80 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Electrical Classification Explosion proof CSAus Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C) ) Class I, Zone 1, Group IIB+H2 cCSA Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB+H2 ATEX Ex d IIB+H2 T4 (Tamb = -40°C to +60°C) Safety Approvals cCSAus ATEX CE Marking SIL2 FMEDA Rating Ingress Protection IP66 Warranty Plug-in detector - 10 year conditional Transmitter - 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -35°C to +55°C; -13°F to +131°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC* * 12 VDC available by special order Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) RFI/EMI Protection Complies with EN 50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Relay Outputs Alarm 1, Alarm 2, and Fault 5A @ 250VAC 5A @ 30VDC Faults Monitored Heater, Loop, Input Voltage Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon TP-700 Hydrogen Sulfide Sensor
Model TP-700 is a non-intrusive “Smart” sensor designed to detect and monitor H2S in air over the range of 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The TP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model TP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model TP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s solid state MOS H2S gas sensor has an infinite shelf life and is supported by a 10-year conditional warranty. Order Guide Specify junction box options (below) PN 967-015520-100 - TP-700 Sensor Assembly (no junction box) PN 967-011520-100 - TP-700 Sensor Assembly with Aluminum Junction Box PN 967-014520-100 - TP-700 Sensor Assembly with 316 SS Junction Box PN 9H7-011520-100 - TP-700 with HART in Aluminum Junction Box PN 9R7-011520-100 - TP-700 with RAM in Aluminum Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-Proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Plug-in field replaceable Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of) Response/Clearing Time T50 <30 seconds; T80 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus Complies with ISA 92.01 Part 1-1998; Performance Requirements for H2S ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in detector - 10 year conditional Transmitter - 2 Years ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -31°F to +131°F; -35°C to +55°C Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 1.0A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Heater, Loop, Input Voltage, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet