Oldham Simtronics
Established in 1848, Teledyne Oldham Simtronics designs and manufactures a wide range of gas detectors, control systems, flame detectors, and wireless technology.
With continuous product development over the past 70 years, Teledyne Oldham Simtronics has always been a worldwide benchmark in gas and flame detection.
Showing all 16 results
-
Oldham Simtronics CTX 300 Fixed Toxic Gas Detector
Presentation The CTX 300 can detect O2, CO2, toxic and refrigerant gases. TELEDYNE Gas & Flame Detection offers a detector version with a wide range of sensors (infrared, electrochemical, semiconductor) according to your application needs. It is also available with or without display. Simplicity Sensor replacement does not require any special menu access. Just replace the sensor without even powering down the transmitter! Reduced maintenance As the only consumable element, the CTX 300 sensor is easily replaceable. New sensors come pre-calibrated from the factory. So during the sensor ex-change, no calibration gas is required, nor adjustments to the detector, or remote central controller are required. FEATURES: Detection of toxic gases or oxygen Interchangeable and pre-calibrated sensor modules Local display (optional) Durable in harsh environments Up to 5 years of life for O2 sensor PART NUMBER GAS TYPE OF SENSOR RANGE (ppm) OPERATING TEMPERATURE WC3oO2F O2 Electrochimic 30.0 % -20 °C la +50 °C WC30O2G 30.0 % -40 °C to +50 °C WC3AO2G 30.0 % -20 °C to +50 °C WC3oO2S 100 % +5 °C to +40 °C WC3oCOA CO Electrochimic 100 -20 °C to +50 °C WC3oCOB 300 -20 °C to +50 °C WC3oCOC 1000 -20 °C to +50 °C WC3oCOD 1.00 % -20 °C to +50 °C WC3oCO2A CO2 Infrarosu 0.50% (5000ppm) -40 °C to +50 °C WC3oCO2B 5.00 % -40 °C to +50 °C WC3oCO2C 100 % -40 °C to +50 °C WC3oHSA H2S Electrochimic 30.0 -20 °C to +50 °C WC3oHSB 100 -20 °C to +50 °C WC3oHSC 1000 -20 °C to +50 °C WC3oNOA NO Electrochimic 100 -20 °C to +50 °C WC3oNOB 300 -20 °C to +50 °C WC3oNOC 1000 -20 °C to +50 °C WC3oN2A NO2 Electrochimic 10.0 -20 °C to +50 °C WC3oN2B 30.0 -20 °C to +50 °C WC3oSOA SO2 Electrochimic 10.0 -20 °C to +50 °C WC3oSOB 30.0 -20 °C to +50 °C WC3oSOC 30.0 -20 °C to +50 °C WC3oCL2 Cl2 Electrochimic 10.0 -20 °C to +50 °C WC3oH2A H2 Electrochimic 2000 -20 °C to +50 °C WC3oH2B 2 % -20 °C to +50 °C WC3oHLA HCl Electrochimic 30.0 -20 °C to +50 °C WC3oHLB 100 -20 °C to +50 °C WC3oHNA HCN Electrochimic 10.0 -20 °C to +50 °C WC3oHNB 30.0 -20 °C to +50 °C WC3oNH3 NH3 Electrochimic 100 -20 °C to +40 °C WC30NH3F 100 -40 °C to +40 °C WC3oNH1 1000 -20 °C to +40 °C WC30NH1F 1000 -40 °C to +40 °C WC30NH2 5000 -20 °C to +40 °C WC3oOET ETO/PO Electrochimic 30.0 -20 °C to +50 °C WC3oHFA HF Electrochimic 10.0 -10 °C to +30 °C WC3oO3A O3 Electrochimic 1.00 -20 °C to +50 °C WC3oPH3 PH3 Electrochimic 1.00 -20 °C to +50 °C WC3oCLO ClO2 Electrochimic 3.00 -20 °C to +50 °C WC3oCCL COCl2 Electrochimic 1.00 -20 °C to +40 °C CTX300-507 Methylene chloride Semiconductor 500 -20 °C to +55 °C CTX300-508 Methyl chloride Semiconductor 500 -20 °C to +60 °C CTX300-657 Toluene Semiconductor 500 -20 °C to +50 °C CTX300-660 Xylene Semiconductor 500 -20 °C to +55 °C CTX300-656 Ethanol Semiconductor 500 -20 °C to +50 °C CTX300-500 R12 Semiconductor 10000 -20 °C to +55 °C CTX300-501 R22 Semiconductor 2000 -20 °C to +55 °C CTX300-509 R123 Semiconductor 2000 -20 °C to +55 °C CTX300-502 R134a Semiconductor 2000 -20 °C to +55 °C CTX300-505 R11 Semiconductor 10000 -20 °C to +55 °C CTX300-506 R23 Semiconductor 10000 -20 °C to +55 °C CTX300-511 R143a Semiconductor 2000 -20 °C to +55 °C CTX300-521 R245fa Semiconductor 1000 -20 °C to +55 °C CTX300-512 R404a Semiconductor 2000 -20 °C to +55 °C CTX300-513 R507 Semiconductor 2000 -20 °C to +55 °C CTX300-514 R410a Semiconductor 1000 -20 °C to +55 °C CTX300-515 R32 Semiconductor 1000 -20 °C to +55 °C CTX300-525 HFO-1234ze Semiconductor 1000 -20 °C to +55 °C CTX300-662 HFO-1234yf Semiconductor 1000 -20 °C to +55 °C PART NUMBER ACCURACY (% at PA FULL SCALE) LIFE SPAN (IN MONTHS) T(50) (SECONDS) WC3oO2F +/- 1.5 % 28 10 WC30O2G +/- 1.5 % 60 10 WC3AO2G +/- 1.5 % 60 10 WC3oO2S +/- 1.5 % 36 < 20 WC3oCOA +/- 1.5 % 48 15 WC3oCOB +/- 1.5 % 48 15 WC3oCOC +/- 1.5 % 48 15 WC3oCOD +/- 1.5 % 48 < 20 WC3oCO2A +/- 2 % 60 <20 WC3oCO2B +/- 2 % 60 <20 WC3oCO2C +/- 2 % 60 <20 WC3oHSA +/- 1.5 % 36 15 WC3oHSB +/- 1.5 % 36 15 WC3oHSC +/- 1.5 % 36 15 WC3oNOA +/- 1.5 % 36 15 WC3oNOB +/- 1.5 % 36 15 WC3oNOC +/- 1.5 % 36 15 WC3oN2A +/- 1.5 % 24 20 WC3oN2B +/- 1.5 % 24 20 WC3oSOA +/- 1.5 % 36 15 WC3oSOB +/- 1.5 % 36 15 WC3oSOC +/- 1.5 % 36 15 WC3oCL2 +/- 1.5 % 24 50 WC3oH2A +/- 1.5 % 24 50 WC3oH2B +/- 1.5 % 24 50 WC3oHLA +/- 1.5 % 24 50 WC3oHLB +/- 1.5 % 24 50 WC3oHNA +/- 2 % 18 30 WC3oHNB +/- 2 % 18 30 WC3oNH3 +/- 3 % 24 <20 WC30NH3F +/- 3 % 24 <20 WC3oNH1 +/- 3 % 24 <20 WC30NH1F +/- 3 % 24 - WC30NH2 +/- 3 % 24 <20 WC3oOET +/- 3 % 36 50 WC3oHFA +/- 3 % 12 50 WC3oO3A +/- 3 % 18 40 WC3oPH3 +/- 3 % 12 40 WC3oCLO +/- 2 % 24 50 WC3oCCL +/- 1.5 % 18 50 CTX300-507 +/- 15 % relative to alarm threshold 36 40 CTX300-508 36 40 CTX300-657 36 20 CTX300-660 36 20 CTX300-656 36 20 CTX300-500 36 30 CTX300-501 36 30 CTX300-509 36 30 CTX300-502 36 30 CTX300-505 36 30 CTX300-506 36 30 CTX300-511 36 30 CTX300-521 36 30 CTX300-512 36 30 CTX300-513 36 30 CTX300-514 36 20 CTX300-515 36 20 CTX300-525 36 30 CTX300-662 36 30 Clear readability Highly sensitive, lighted display allows local reading Effective power-up indication by indicator lights Indication of maintenance or fault function by LED High-Level technology Pre-calibrated sensor avoiding the need to use unstable gases on site for calibration purposes High-performance semiconductor type detector (detection of freon gas, etc.) Available in an infrared version for CO2 Advanced design Highly resistant to environmental elements Avoids having to use protective covers Heavy-duty Use of polycarbonate and stainless steel mounting hardware Resistant to corrosive agents (H2S, HCl, sea spray,…) Durable housing Specifically adapted options Removable filters, interchangeable without opening the housing (which is dust-proof, condensation-proof and water resistant) Splash guard Gas collector cone Mounting brackets Pitot tubes, floats, heating protective device, etc. Remote calibration cup Enclosure: Polycarbonate housing Function: 4-20 mA output analog transmitter Display: Highly visible backlight LCD display unit (optional, gas dependent) Indicator lights: In operation: green color: Failure / maintenance: orange color Wiring: 2 wires shielded cable for CTX300 without display 3 wires shielded cable for CTX300 with display Cable entry: M16 cable gland (outer diameter 4 to 10 mm) Power supply: 15 to 32 V DC Maximum Power Consumption: CTX 300 without display unit: 60 mA, CTX 300 with display unit: 110 mA, CTX 300 without display semiconductor versions: 100mA Operating temperature: without display: -40°C to +50°C (-40°F to +122°F), sensor dependent with display: -20°C to +50°C (-4°F to +122°F), sensor dependent Sealing: IP 54, NEMA 3 & 3R Weight: 520 g (18.2 oz) Certification: EMC according to EN 50270:06 CSA CLASS 812 86, CLASS 4812 06 (SIGNAL APPLIANCES) all versions exept CO2 versions Impedance: 32 ohms max loop for CTX 300 with display unit and for semiconductors sensor versions, 64 ohms max loop for CTX 300 without display unit Product Data Sheet -
Oldham Simtronics DG-TT7-S Solid-State (MOS) Gas Detector
The MultiTox DG-TT7-S is a solid state (MOS) based smart gas detector for the detection of Hydrogen Sulphide. The device has been designed to withstand harsh environment and provide easy operation The unit is fully configurable using a wireless hand-held terminal TLU, using a magnet or by using HART protocol option. The configuration of the outputs is adjustable using the TLU or the magnet that can be used in areas classified as potentially explosive. The MultiTox DG-TT7-S is SIL2 certified, 3 on board relays in option, plug and play sensors and a high visible display that changes colour depending on the status mode. The unit may be interfaced directly with a wide range of centrals and PLC’s. The device supports HART 7 protocol option for full configuration and diagnostics over non-proprietary interface. This new version also offers automatic calibration, TELECAPTEUR Calibration Management Software. It allows loading, comparison and logging of the last calibrations carried out and this can be done by one person only. (one man calibration) Features High visible display Display color is status dependent Ideal for Desert & Artic Environments Technical data General: Technology Solid-state Metal Oxide Semiconductor Detects Hydrogen Sulphide Range 0-20 ppm H2S 0-50 ppm H2S Performance: Accuracy +/- 2 ppm or +/- 10% reading Zero drift <1 ppm Sensor life Better than 5 years (environment dependant) Output signal: Standard 0-22mA encoded: * 0-4mA: fault mode, calibration, inhibit (current values are user configurable) * 4-20 mA: measurement * 22mA: overange Max. load impedance 700 Ohms Options HART Protocol (Version 7) 3 configurable dry contact relay outputs, max 1A / 30V Lonworks (Syntel) Local display 4 digit, ultrabright LED display, color change background according to the status (green=normal operation, amber=Fault mode, red=Gas Alarm, purple=Inhibit/Warm-Up mode), self adjust backlight depending on luminosity Electrical: Power supply 24V DC, range (18 - 35V DC) Power consumption 2W normal (5W max) Connection 0.3 mm2 (22 AWG) - 2.5 mm2 (14 AWG) 3 wire shielded cable Environmental: Storage -40°C to +65°C (-40°F to +149°F) Operation -40°C to +65°C (-40°F to +149°F) Option Sunshade, max. temp. 85°C (185°F) Humidity 99% RH (non-condensing) Pressure Atmospheric pressure +/- 10% Ingress IP66 RFI /EMI Complies with EN50270 Housing: Material 316L stainless steel Weight 4 Kg (8Lbs) Approvals: ATEX II 2 G Ex d IIC T6 Gb or Ex db IIC T6 (-40°C to +65°C / -40°F to +149°F) IECEx Ex d IIC T6 Gb or Ex db IIC T6 SIL SIL2 approved by 3rd party Accessories: TLU600 Infrared remote control unit AS056-250 Sun shade AS005 Calibration cup AS047 Display protection AS011-2 Sample flow housing AS019 Splash guard CAL-K1C-xxAE-1 A1 -00 Calibration kit 20ppm H2S CAL-K1C-31AF-1A1-00 Calibration kit 50ppm H2S CAL-TUBE-H2S-MOS In-line humidifying tube for calibration Other products (stainless steel range): DG-TT7-E MultiTox, Toxic Gas Detector DF-TV7 or -V MultiFlame, Flame Detector DG-TX7-X MultiXplo, Flammable Gas Detector Product Data Sheet -
Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector
The MultiXplo DG-TX7 is an intelligent catalytic sensor based flammable gas detector used to detect a wide range of gases, including hydrogen (H2). The device has been designed for ease of installation, operation and maintenance in testing environments. The MultiXplo DG-TX7 employs a pair of OXYCOL catalytic sensors in a compensated circuitry in order to provide reliable flammable gas detection in harsh environments, as long as oxygen is present. The intelligent microprocessor driven unit is fully configurable using a wireless handheld terminal (TLU) or optionally via HART giving true flexibility to the installer. Parameters such as relay operation and alarm levels are all set via the TLU; a hazardous area approved handheld unit. In addition, the sensor element is protected by the onboard electronics to prevent exposure to over-range LEL gas concentrations. This helps reduce on-going maintenance and service costs. Users can select between 4-20 and 0-22mA depending on system requirements. The unit may be interfaced directly with a wide range of panels, controllers and PLC’s etc. Device status, including measured gas level is indicated on a colour coded 4 digit LED display. Features High visible display On board relays Display color is status dependent Technical data General: Technology Low temperature oxidation process, Oxycol Detects Flammable Gases Range 0 to 100% LEL Calibration with calibration gas Performance: Response time T90 < 15 s (Methane) Zero drift +/- 3% Full scale deflection Accuracy +/- 5% Full scale deflection Repeatability +/- 1% Full scale deflection Sensor life Better than 5 years Output signal: Standard 4-20mA, max. load impedance 700M (Std. ) 2 x configurable Relays max 1 A / 30V option HART (R) HART Protocol (7th edition) option 0-22mA (User configurable) option Lonworks (Syntel) Local display 4 digit led display and backlight color status with automatic intensity adjustment Electrical: Power supply 24V DC, range (18 - 28V DC) Power consumption 2W normal, 5W max (backlight at max) Connection 0.3 mm2 (22 AWG) - 1.5 mm2 (16 AWG) Shielded cable recommended Environmental: Storage -40°C TO +70°C (-40°F TO 1 58°F) Operation -40°C TO +60°C (-4°F TO 1 40°F) Option Sunshade, max. temp. 85°C (185°F) Humidity 99% RH (non-condensing) Pressure Atmospheric pressure +/- 10% Ingress IP66 RFI /EMI Complies with EN50270 Housing: Material 316L stainless steel Weight 4 Kg (8Lbs) Approvals: ATEX II 2 G Ex d IIC T6 Gb (-40°C to +65°C) (-40°F to +149°F) IECEx Ex d IIC T6 Gb IECEx LCI 11.0060X Conformities: EN60079-29-1 Accessories: TLU600 Infrared remote control unit AS056-250 shade AS005 Calibration cup AS047 Display protection AS011 -2 Sample flow housing AS019 Splash guard CAL-K1 C-xxDF-1 A1 -00 Calibration kit 20ppm H2S Other products (stainless steel range): DGi-TT7-E MultiTox, Toxic (EC Cell) Gas Detector DG-TT7-S MultiTox, Solid-State (MOS) Gas Detector DG-TV7 MultiFlame, Flame Detector Product Data Sheet -
Oldham Simtronics DGi-TT7-E Electrochemical Toxic Gas Detector
The MultiTox DGi-TT7-E is an intelligent gas detector employing an array of sensor types. The device has been designed for ease of operation and maintenance. All DGi-TT7-E are constructed from a common housing and electronics with the detection properties being determined by the type of sensor (cartridge) used. A wide range of cells are available, these cells are intrisically safe protected, and may be replaced with the detector powered which minimises the system down time. The intelligent, microprocessor driven unit is fully configurable using a wireless hand-held terminal (TLU) or by using the hard wired HART option giving true flexibility to the installer and reduced service costs. Elements such as relay operation and alarm levels are all set via the TLU, a hazardous area approved hand-held unit. The unit may be interfaced directly with a wide range of panels, controllers and PLC’s etc. Its integral daylight readable alphanumeric display indicates local status and alarm level. Thanks to the hot swat field cabling technology, the sensor can be changed in a hazardous area without requiring area declassification. The device offers HART Protocol 7th edition output as an option which allows full configuration and diagnostics over nonproprietary interface. Features High visible display On board relays Display color is status dependent Technical data General: Technology Auto heating of electrochemical cell Output signal: Standard 4-20mA, max. load impedance 700 (Std. ) 2 x configurable Relays max 1 A / 30V Option HART(R) HART Protocol (7th edition) (pending) Option 0-22mA (User configurable) Option Lonworks (Syntel) Local display 4 digit LED display with automatic intensity adjustment Electrical: Power supply 24V DC, RANGE (18 - 28V DC) Power consumption 2W NOMINAL, 7.8W MAX. HEATING Connection 0.3 mm2 (22 AWG) - 1.5 mm2 (1 6 AWG) Shielded cable recommended Environmental: Storage -40°C to +70°C (-40°F to +158°F) Transmitter 0°C to +20°C (0°F to +68°F) Cartridge / Cell Operation See above table of gases Humidity 99% RH (non-condensing) Pressure Atmospheric pressure +/- 10% Ingress IP66 RFI /EMI Complies with EN50270 Housing: Material 316 L stainless steel Weight 4 Kg (8Lbs) Approvals: ATEX II 2 G Ex d ia I IC T6 Gb (-20°C to +60°C) Certificate number LCIE 13 ATEX 3024 X IECEx Ex d ia I IC T6 Gb - IECEx LCIE 13.001 X Accessories: TLU600 Infrared remote control unit AS056-250 Sun shade AS005 Calibration cup AS051 Calibration cup for breakable ampoules AS011 -2 Sample flow housing AS019 Splash guard CAL-K1 C-xxAE-1 A1 -00 Calibration kit (xx = gas to be specified) CAL-A00-xxAF-000-00 Box of 10 breakable gas ampoule (xx = 31 for1 00ppm NH3, 39 for 50ppm H2S) For use with AS051 cup AS047 Display protection Other products (stainless steel range): DG-TT7-S MultiTox, Solid-State (MOS) Gas Detector DF-TV7 MultiFlame, Flame Detector DG-TX7 MultiXplo, Flammable Gas Detector Product Data Sheet -
Oldham Simtronics GD1 Laser Open Path H2S Gas Detector
The GD1 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from offshore production facilities to wastewater treatment plants. At the heart of the detector is a tunable laser diode that eliminates environmental effects from sun, rain, sand, and fog. The laser scans single absorption lines where there is no interference from other gases. Unlike traditional methods for detecting H2S (MOS or EC cell), the GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk. The complete optomechanical design and construction is so stable that an ultra fast response time can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. The detector is supplied with worldwide hazardous area approvals, is suitable for SIL2 applications and comes with a 5 year warranty. Features Fail safe Fast response time Calibration free Operates up to 98% of obscuration Technical data: General Detection method IR- New IR laser scanning Source Tunable laser diode Laser Class 1, eye safe Detected gas H2S Range 0-200 ppm*m 0-500 ppm*m 0-1000 ppm*m 0-2000 ppm*m 0-5000 ppm*m 0-20000 ppm*m Path length 5 - 75 m Self test Continuous Calibration Factory set, no field recalibration Performance: Accuracy <±4% of full range Repeatability <±4% of full range Response time <5 sec Optics: Alignment ±0.30 Degree Optics Heated (transmitter and receiver) Tolerable obscuration 98% (Allowable signal loss) Output signal: Standard 4-20mA source or sink HART® Fault signals Fault 1 mA Beam block 2 mA Warning 3 mA (optional) Electrical: Power supply 24V DC, range (18 - 32V DC) Power consumption <15 W Cable entry M25 Temperature range: Storage -55°C to +65°c (-67°f to + 149°f) Operating -55°C TO + 65°C (-67°F TO +149°F) Atex flameproof -55°C to + 75°c (-67°f to +167°f) Humidity (operation) 100% RH Material: Tx and rx housing Stainless steel (ASTM 316) Junction box Grp Weight: Approx. 5.5 Kg (12 lbs) per tx or rx Approx. 2.0 Kg (4.4 Lbs) per tx or rx junction box Dimensions: Tx and rx housing Ref. Outline drawing Warranty: 5 Years full warranty on detector system Approvals: Atex rating tx/rx II 2 g Ex d [op is] IIC T6/T5 Gb Atex rating jb II 2 g Ex e IIC T5 Gb Iecex Ingress Sil Suitable for use in SIL2 systems Accessories: GD1-X00-TT01 Alignment kit GD1-X00-TT02 Test cell Product Data Sheet -
Oldham Simtronics GD10P CO2 IR Point Gas Detector
The GD10P-CO2 uses state of the art IR gas measurement, to give a fast, reliable response. The GD10P has set the standard for gas detection in the areas of safety, stability and low maintenance. The GD10P comes wi th 5 years warranty The GD10P-CO2 has been designed with features that provide an effective response to the detection of CO2 in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations. The GD10P-CO2 differs from all other point infrared gas detectors, because they utilise silicon based solid-state sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. We offer the longest combined detector and IR source warranty on the market. Supplied with worldwide hazardous area approvals. Certified for use in SIL 2 system. An industry standard HART® interface is used for configuration of special fault levels as well as access to extended maintenance data. Features and benefits include an integral termination compartment for reduced installation time: the unit is ready out of the box, low power consumption which reduces load on UPS and independently heated mirror and lens for high performance detection in rough environmental conditions. Features Solid state IR sources (SimSourceTM) for superior long term performance compared to filament lamps No recalibration, monitors and accounts for all changes in optical path thanks to true dual path, double compensation optical design Selectable response rate Dual layer weather protector (No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand) Early dirty optics warning for improved preventative maintenance Technical data General: Detection method Ir-absorption, dual wavelength, dual path Ir-source Solid state ir source, 50hz flash Gases detected Co2 Self-test Continuous Calibration Factory set, no field recalibration Configuration Hart (response time, fault levels) Performance: Accuracy ±5% Fs between 0-50 % reading ±7% Fs between 50-80 % reading Response time Configurable T20 = 1 sec. (0.3 Sec) T50 = 2.5 Sec (0.7 Sec) T90 = 6 sec (1.6 Sec) Output signal: Standard Current source 4 – 20 mA, max. Load Impedance 500 ohm Option Current sink 4 – 20 mA HART® Maintenance and configuration Detector Faults (HART configurable) - Early clean optics - Dirty optics - Detector failure Configurable (HART) Pre warning (2 mA) Dirt accumulation (1 mA) Internal fault (0 mA) Electrical: Power supply 24V dc, range (18 - 32v dc) Power consumption Approx. 3.5 W Connection 3 Wires (0.5mm2- 2.5 mm2) Cable entry M20 exe cable gland Temperature range: Storage -40°C to + 70°c (-40°f to +158°F) Operating -40°C to + 60°C (-40°F to +140°F) Humidity (Operation) 100% RH Explosion proof housing: Protection category IP66/IP67 din 40050 Housing material Stainless steel sis2343 (astm316) Weight Approx. 2.9 Kg Dimensions (LxWxH) 251 X 1 04 x 1 05 (mm) 9.89 X 4.1 X 4.13 (Inches) Warranty: 5 Years full warranty on a complete instrument 15 Years warranty on the ir-sources Approvals: ATEX / IECEX / INMETRO II 2G Ex de IIC T6 Gb CSA Ex de IIC T6 (Canada only) Class I, Division 2, Groups A, B, C, and D (USA and Canada) Other SIL2 (Software SIL3), ABS, MED Versions: Standard ranges (volume) : 10000Ppm (1%) , 3%, 5% 10% and 100% The 0-100% volume is also compensated for Methane interference. Front cover: Required, select one - Weather protection For standard point detector - Sample flow housing For sampling systems and testing - Duct mount kit For through wall installation Accessories: Mosquito net Extra insect protection Sun shade Shielding for extreme radiation exposure Product Data Sheet -
Oldham Simtronics GD10P IR Point Gas Detector
The GD10P infrared gas detector is the market reference for combustible gas detection. It has set the standard for gas detectors in the areas of performance, response time, stability and low maintenance. GD10P comes with a 5 year warranty. The GD10P differs from all other infrared gas detectors because it uses a solid-state infrared source. The optical block is so robust that it comes with a 15 year warranty and provides an unparalleled detector stability and an unmatched service life. The GD10P also features heated optics to prevent condensation, a HART interface, fail-safe operation and global approvals. Features 5 years warranty 15 years warranty semiconductor IR source (Simtronics patent) Zero maintenance Response Time T90 < 1.0 s SIL 2 certified (SIL3 software) Early dirty optics warning for improved preventative maintenance Technical data General: Technology IR-absorption, dual wavelength, dual path IR-source Solid state IR source Gases detected Hydrocarbons (for CO2 see separate data sheet) Self-test Continuous Calibration Factory set, no field recalibration Configuration HART protocol Performance: Accuracy Refers to -20°c to +45°c ±3% FS between 0-50 % reading ±5% FS between 50-100 % reading Response time All gases T20 = 0,7 sec T50 = 1,7 sec T90 = 4 sec Output signal: Standard Current source 4 – 20 mA, max. Load Impedance 500 ohm Option Current sink 4 – 20 mA HART® Maintenance and configuration HART 7 Detector Faults (HART configurable) - Early clean optics - Dirty optics - Detector failure Pre warning 2 mA Dirt accumulation 1 mA Internal fault 0 mA Electrical: Power supply 24V DC (18 - 32V DC) Power consumption Approx. 3.5 W Connection 3-wire shielded cable (0.5-2.5mm²) Cable entry M20 Ex e cable gland Temperature range: Storage -40°C to +70°C (-40°F to +158°F) Operating -40°C to +60°C (-40°F to +140°F) Humidity (Operation) 0- 100% RH Explosion proof housing: Ingress Protection IP66/IP67 Housing material Stainless Steel SIS2343 (ASTM316) Weight Approx. 2.9 Kg Dimensions (LxWxH) 264 X 104 x 106 mm Warranty: 5 years full warranty on a complete instrument 15 years warranty on the infrared sources Approvals: ATEX / IECEx / INMETRO II 2 G / Ex db eb IIC T6 Gb CSA C22.2 No 152-M984 and ANSI 12.13.01-2000 Ex d e IIC T6 (for Canada only) Class I, Division 2, Groups A, B, C and D (USA and Canada) Various SIL 2 certified (software is SIL 3), ABS, MED Versions: Gas Ranges Methane 0-100%LEL, 0-100%vol Propane 0-100%LEL, 0-100%Vol Front cover: Required, select one Weather protection Supplied as standard Sample flow housing For sampling systems and bump test Duct mount kit For duct monitoring Accessories: Mosquito net Extra insect protection Sun shade Shielding for extreme solar radiation exposure or snow deposit Product Data Sheet -
Oldham Simtronics GD10PE IR Extended Point Gas Detector
The GD10PE is designed for critical applications involving large volumes of air with high velocity. In places where you need fast reliable detection of low gas concentrations. GD10PE is in a class of its own. The versatile GD10PE is suitable for monitoring, among others, the HVAC air intakes of living quarters, temporary refuges and local equipment rooms. In addition the ventilation air and combustion air intakes of gas turbines can be monitored along with the ventilation air extract duct, the only location where you can guarantee to detect a gas leak on a turbine package. With a measuring range of 0-20% LEL the GD10PE is 5 times more sensitive than standard point detectors. The GD10 range of infrared gas detectors differ from all other models, because they utilise si licon based solid-state infrared sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. An industry standard HART® interface is used for configuration of the levels as well as access to maintenance data. Features and benefits include an independently heated mirror and lens for high performance detection in rough environmental conditions and guaranteed continuous operations at 85°C which make this instrument suitable for turbine ventilation extract ducts. Features Solid state IR sources (SimSourceTM) for superior long term performance compared to filament lamps No recalibration, monitors and accounts for all changes in optical path thanks to true dual path, double compensation optical design Selectable response rate Dual layer weather protector (No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand) Early dirty optics warning for improved preventative maintenance Technical data General: Detection method Ir-absorption, dual wavelength, dual path Ir-source Solid state ir source, 50hz flash Detection range 0-20% Lel (0-1% vol. ) Methane Gases detected Hydrocarbons Self-test Continuous Calibration Factory set, no field recalibration Performance: Accuracy Refers to -20°c to +60°c (-4°f to +140°f) ±1,4% Lel full scale ±1% Lel (0-10% lel reading) ±1.4% Lel (10-20% lel reading) Response time Detector reading: 100% Lel test gas: 20% Lel test gas: T20 0.5 Sec. 0.8 Sec. T50 0.8 Sec. 2.1 Sec. T90 1.1 Sec. 5 Sec. Output signal: Standard Current source 4 – 20 mA, max. Load Impedance 500 ohm Option Current sink 4 – 20 mA HART® Maintenance and configuration Detector warnings: - Early clean optics - Dirty optics - Detector failure 2 mA 1 mA 0 mA Electrical: Power supply 24V DC, range (18 - 32V DC) Power consumption Approx. 3.5 W Connection 3 Wires (0.5mm2 - 2.5 mm2) Cable entry M20 exe cable gland Environment: Storage -40°C to + 70°c (-40°f to +158°f) Operating -40°C to + 60°C (-40°F to +140°F) Probe, inside duct Up to +85°c (185°f) Humidity (operation) 100% RH Explosion proof housing: Main compartment Exd IIC T6 Terminal comp. Exe Protection category IP66/IP67 din 40050 Housing material Stainless steel SIS2343 (ASTM316) Dimensions (lxwxh) 805x104x106 (mm) 31.7x4.1x4.2 (Inches) overall Weight (detector) Approx. 6.5 Kg (14.3 Lbs) Weather protection Approx. 0.3 Kg (0.7 Ibs) Duct mount kit Approx. 2. 1 Kg (4.6 Ibs) Warranty: 5 Years full warranty on a complete instrument 15 Years warranty on the IR-sources Approvals: ATEX / IECEX / INMETRO II 2 G EX db eb IIC T6 Gb CSA C22.2 No 152-M1984 and ANSI 12.13.01-2000 ex de IIC T6 (Canada) Class I, Division 2, groups A, B, C and D (US and Canada) Other SIL2 (Software SIL3), ABS, MED Versions: Gas Ranges Methane 0-20% LEL Ethylene 5,000 ppm Accessories: Weather protection Required for standard installation Sample flow housing For sampling systems and testing Duct mount kit For through wall installation Product Data Sheet -
Oldham Simtronics iTrans 2 Fixed Gas detector
Characteristics Large Sensor Offering – Electrochemical, Catalytic and Infrared Non-Intrusive Calibration Smart Sensor HART (optional) RS-485 Modbus Programmable Relays (optional) Dual Gas Sensing (optional) Features Oil and Gas Industry Offshore Drilling Utilities and Power Petrochemical Industry Water and Waste Treatment Food and Beverage Production Other features and benefits Dual Gas Sensing The iTrans 2 can detect and display up to two gases on certain models. Both gas sensors may be mounted directly to the transmitter, or may be mounted remotely Wide Sensor Offering The iTrans 2 supports Electrochemical, Catalytic Bead and Infrared sensors. The iTrans 2 is available for most common industrial gases, allowing of standardization for your gas detection equipment. Smart Sensors The iTrans 2‘s smart sensors come factory pre-calibrated and automatically send sensor information, such as sensor life, to the transmitter. A sensor life indicator is displayed immediately after each calibration. Dual-channel split-screen LED display For optimum visibility in dark places Non-Intrusive Calibration The iTrans 2‘s non-intrusive interface keys operate with a simple magnetic wand and allow for full transmitter configuration and calibration without opening the unit’s explosion-proof housing. Programmable Relays The microprocessor-controlled transmitters are capable of independent operation or multi-point system configuration. With optional on-board relays, the monitor has the added ability of stand-alone operation, activating alarms, horns or fans, and can also shut down a system without the need to wire back to a central control panel. Multiple Wiring Options The iTrans 2 can be configured to meet almost any installation application. Common configurations includes: 3-Wire (4-20mA) Models - Allow for full utilization of the iTrans 2‘s features and options and can be used with all of the iTrans 2‘s sensors. 4-Wire (Digital ModBus) Models - Allows for full utilization of the iTrans 2‘s features and options and can be used with all of the iTrans 2‘s sensors. HART™ Communication Protocol With the optional HART Communication Protocol, the iTrans 2 offers remote diagnostics, set-up or calibration by super - imposing a high-frequency current across the industry standard 4-20mA analog line. Stainless Steel Enclosure An optional stainless steel enclosure for corrosive environments Sensors The iTrans 2 is available with sensors for most common gases including: Infrared, CO2 , Catalytic Bead Combustible and electrochemical sensors. It can support simultaneous detection from two sensors, either directly attached to the display, or remote sensors. Versatile The iTrans 2 can be configured to meet nearly any application through its state-of-the art features and options. Explosion-proof HART (optional) RS-485 Modbus Stainless Steel Enclosure (optional) Programmable Relays (optional) 3-wire, 4-wire Installations Dual Gas Sensing (optional) Remote Sensing (optional) Large Sensor Offering – Electrochemical, Catalytic and Infrared Easy to use Smart Sensor Non-Intrusive Calibration Dual-channel split-screen LED display Ordering information: iTrans 2 offers a wide variety of sensor configurations and relay options for maximum flexibility and affordability. Use the following guide to select the options that best fit your monitoring needs and applications. Oldham recommends that a fixed system application survey be completed to help provide the most accurate assessment of your equipment requirements. iTrans 2 Base Part Number : iTrans 2-ABCDEFG (sensor options listed below) Magnetic calibration tool, and calibration cup are standard items with all iTrans 2 monitors. Accessories Part number Image code By-Pass / Flow-thru Kit P/N 77014579 a Splash guard / remote Cal Cup for Toxic, O2, and LEL P/N. 77015303 b iTrans 2 Calibration Wand P/N. 77024065 c iTrans 2 Splash guard P/N. 77023588 d iTrans 2 Calibration Cup P/N. 77023513 e Measuring ranges: Combustible Gases 0-100% LEL in 1% increments Hydrogen 0-999 ppm in 1 ppm increments Oxygen 0-30% by Volume in 0.1% increments Ammonia 0-500 ppm in 1 ppm increments Carbon Monoxide 0-999 ppm in 1 ppm increments Hydrogen Sulfide 0-500 ppm in 1 ppm increments Sulfur Dioxide 0.2-99.9 ppm in 0.1 ppm increments Hydrogen Cyanide 0.2-30 ppm in 0.1 ppm increments Hydrogen Chloride 0.2-30 ppm in 0.1 ppm increments Phosphine 0-1 ppm in 0.01 ppm increments Nitrogen Dioxide 0.2-99.9 ppm in 0.1 ppm increments Nitric Oxide 0-999 ppm in 1 ppm increments Chlorine 0.2-99.9 ppm in 0.1 ppm increments Chlorine Dioxide 0.02-1.00 ppm in 0.1 ppm increments Carbon Dioxide 0-100% by Volume in 1% increments Carbon Dioxide 0-0.5% by Volume in 0.01% increments Carbon Dioxide 0.2-30 ppm in 0.1 ppm increments Technical specifications: Sensors Combustible Gases: Catalytic Toxic / Oxygen: Electrochemical, Infrared (CO2) Warranty from date of shipment 2 years on electronics 3 years on infrared sensors (CO2) 2 years on catalytic (LEL), CO and H2S sensors 18 months on O2 sensors 12 months on other sensors Detected Gases See Ordering Guide Material Epoxy Coated Aluminium or 316 Stainless Steel Display Dual-channel split-screen LED display (4 digit, 7 segment arrangement per channel) provides simultaneous display of one or two gases. Input voltage 12-28VDC operating range (24VDC typical) Power Consumption 150mA@24VDC (Electrochemical sensor) 250mA@24VDC (Combustible gases catalytic) 0.8A peak (single gas) 170mA@24VDC (Infrared) 0.5A peak (single gas) 350mA@24VDC (Combined catalytic/Infrared) 1,2A peak (two gas) Ingress Protection NEMA 4X, IP66 Response Time (catalytic methane) T50: < 10 seconds T90: < 30 seconds Humidity Range 10-90% RH (non-condensing), typical Temperature range (sensor specific) -40°C to +75°C (-40°F to +167°F) Dimensions 127 x 153 x 129 mm (5.0” x 6.0” x 5.1”), 2.9 Kg (6.4 lbs) Cable 3-wire or 4-wire Maximum Cable Loop 15 Ohm (3-wire configs) 10 Ohm (4-wire configs) Output Signal Standard: 4-20mA (source) + RS-485 Modbus (9600 baud) Optional: HART Protocol Alarm relays (opt) 3 alarm relays (5 / Two user-programmable relays, SPST, N.O. Amps at 30VDC) Homologations Sensor Specific CCSAUS* One fault relay, SPST, N.C. Class I, Div 1, Groups B, C, D Ex d IIB + H2 T5 AEx d llB + H2T5 (1) Class I, Div 2, Groups A, B, C, D (2) ATEX and IECEx II 2G - Ex db IIB + H2 T5 Gb (1) NEPSI GYB15.1621X - Ex d IIB + H2 T5 Gb GB15322.1-2003 Fire protection INMETRO Ex db IIB+H2 T5 Gb(1) (1) Combustible gases, Hydrogen, Oxygen, Carbon Monoxide, Hydrogen Sulfide, Sulfur Dioxide, Hydrogen Cyanide, Phosphine, Nitrogen Dioxide, Nitric Oxide, Carbon Dioxide Product Data Sheet -
Oldham Simtronics OLC(T) 100 Fixed Gas Detector
The OLC/OLCT 100 range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions, the OLCT 100 is suitable for detection of all gases in ATEX zones. The OLCT 100 is available in a stainless steel version, offering increased resistance to corrosive elements (ideal for marine, wastewater treatment plants, food processing activities, etc). This stainless steel intrinsically safe version is certified for use in zones 0 (gas) and 20 (dust), whereas all other versions of the OLCT 100 are certified for use in zones 1 (gas) and 21 (dust). Features Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Applications Steel mills Petrochemical facilities Chemical industry Pharmaceutical industry Food industry Refrigeration industry Water treatment Our products are always application-driven, solution-oriented. Options include: OLCT 100 transmitter with 4-20 mA output OLC 100 detector with a Wheatstone bridge output for detection of combustible gases IR Sensor The infrared sensor provides detection of CO2 and refrigerant gases and is warranty 2 years. OLCT 100 XP Explosion-proof version is equipped with a catalytic, electrochemical or semiconductor sensor, for detection of combustible, toxic gases or oxygen. OLCT 100 IS Intrinsically safe version is equipped with an electrochemical sensor for detection of toxic gases or oxygen. OLCT 100 XP IR Explosion-proof IR version is equipped with an infrared sensor for detection of CO2 , SF6 and some freons. OLCT 100 XP HT High temperature explosion-proof version for detection of combustible gases up to 200°C. High temperature cable included: 5, 10, 15 meter lengths. Reliability The OLC(T) 100 is SIL 2 certified by INERIS, according to the EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors. Unique advantages providing the solution you need Design advantages Pre-calibrated sensors for detection of: combustible gases: LEL catalytic and IR toxic gases oxygen Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Inputs Series 80 sensors have up to 9 glands dedicated to cable wiring Design advantages: The minimum configuration includes: 1 electrical input dedicated to a sensor. two 4-20 mA or binary inputs. This configuration allows any other sensor from the network to be recognized (e.g temperature sensor, emergency stop, flame detector, smoke detector). Outputs 4/20 mA with smart signal processing analog signal 4-20 mA data signals between 0 and 4 - 20 and 25mA The transmitted signal, between 0 and 3.2 mA and above 20 mA, can be processed to interpret and identify a wide range of trouble parameters such as: line faults, sensor faults, embedded electronics faults, ambiguity resolution, inhibition of calibration, maintenance call (initial drift or drift over time). RS485 (1200 bauds, 38kb Modbus ASCII for MX 62). The RS485 link gives access to : - sensor measurement - status and default - internal relay management Relays The relays are 2A / 250 VAC type with potential free SPDT contacts. Two types of relays: 2 gas alarm relays or supplementary inputs 1 fault relay The relays are actuated either directly by the sensor electronics or supplementary inputs, or from the MX62 central unit or the control system to which the sensor is connected. The relays can be in safety mode or not, triggered on increasing or decreasing alarms, manually* or automatically acknowledged. * By remote control, by pressing an external pushbutton connected to the dedicated binary input, by acknowledging on the MX 62 unit or the control system to which the sensor is connected. Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Technical advantages Stand-alone central unit For relay control, the OLCT 80 can operate as a standalone unit: an indisputable advantage in a classified explosion risk zone. Flexibility of connection modes OLCT 80 sensors can be connected either: in loop (opto-isolated - up to 16 sensors), 4-20 mA, under direct power and operate as a central unit. Operation traceability The operator can check records locally for the most recent time-date stamped events. Communication Remote dialogue with the sensor using IR remote control. Measurement power supply redundancy Independent ports allow a redundant connection to the measurement unit. Low power requirements The leading edge technology used in the OLCT80 transmitter makes it very energy efficient. This major advantage means that more sensors can be connected, with smaller wire cross-sections and over greater distances. Logistic advantages Loop arrangement The transmitter is perfectly adapted to mounting and connection to the digital fieldbus loop of the MX 62 unit. Supporting 1 to 3 digital addresses: the sensor block (detection element), the two 4-20 mA auxiliary inputs. Certification The OLCT80 Series is certified to the specifications required by standards EN 50054, 45544 and 50104 (environmental standards, explosive and toxic gases and oxygen) and to the specifications of standards EN 50270, EN 6052 (electromagnetic compatibility, ingress protection). OLCT 80 uses digital logic and software technologies. The sensors are protected and in compliance with the specifications of standard EN 51271: analog and digital values track each other homogeneity of digital resolution and response time with the specifications required internal self-diagnostics Ordering Information Accessories A Calibration cup (6331141) allows introduction of calibration gas on the sensor B Bypass adapter (6327910) allows measurement of samples C Splash guard system (6329004) protects the detector from liquid projections D Remote gas introduction head (6327911) allows introduction of gas without opening the detector E Removable protective filter (6335975) protects the sensor against projections and dust F Duct measurement kit (6793322) allows gas monitoring in a duct G Mounting bracket (6322420) allows the mounting of the detector to the ceiling H Protective cover (6123716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6793718) allows the replacement of another OLDHAM detector without redrilling J Wall mounted collecting cone (6331169) for use with lighter-than-air gases K Ceiling mount collecting cone (6331168) for use with lighter-than-air gases Product Data Sheet -
Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector
Design for commercial applications, OLC and OLCT10 detectors perfectly suit the protection of equipment and personnel in boiler or charging rooms where atmosphere may contain flammable gases. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Catalytic sensors 4-20mA output signal with OLCT 10 Dust and humidity resistant Fast and accurate response ATEX Approval for use in hazardous areas (zone 2 and 22) OLC10 and OLC10 TWIN OLC 10 TWIN allows connection of 2 sensors with a single channel without any additional junction box. Applications: Boiler rooms Charging rooms Wiring arrangement between OLC(T) 10 and MX 32 control unit Wiring arrangement between OLC 10 TWIN and MX 32 control unit Dimensions: Technical features: OLC 10 / OLC 10 TWIN OLCT 10 (Catalytic) Range Combustible gases - 0 to 100% LEL , Methane, Butane, Propane, LPG, Natural Gas or H2 Combustible Gases - 0 to 100% LEL Methane, Butane, Propane, GPL, Natural Gas or H2 Signal output Wheatstone Bridge Normal operation 4-20 mA (Fault < 0.5 mA or > 23.2 mA) Settings Managed by control unit Without opening the enclosure by means of 2 petentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Set to 23.2 mA if value > 100% LEL according to European standard EN 61779-4 Disable on request when managed by a suitable controller Consumption See on the manual of the controller 100 mA max Cabling OLC 10 : 3 Wire, shielded, core size 1,5 mm2 max. cable length 300 m 1 cable-gland M16 (outer \ 4 to 8 mm)OLC10 TWIN : shielded, core size 1,5 mm2, 3-wire to control unit, 4-wire between both sensors, max. cable length 300 m, 2 cable-glands M16 (outer \ 4 to 8 mm) 3-wire, shielded, core size 1,5 mm2, max. cable length 1km if connected with control unit (32 W max un loop) 1 cable gland M16 (outer \ 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP Rating IP65 IP65 Expected lifespan 36 to 48 months (sensor) 36 to 48 months (sensor) Operating temperature -10 to + 45 °C -10 to + 45 °C Operating humidity range -20 to +55°C -20 to +55°C Pressure Range 1 bar ± 20 % 1 bar ± 20 % Response Time Flammable gas : < 10s Flammable gas : < 10s Accuracy +/- 3% LEL +/- 3% LEL Certification EN 50270:2015 (type2) ATEX II 3 GD / Ex ec dc IIC T6 Gc Ex tc IIIC T85°C Dc EN 50270:2015 (type2) Product Data Sheet -
Oldham Simtronics OLCT 10N Fixed Digital Gas Detector
The OLCT 10N is a digital gas detector designed for detection of the most common gases in commercial and light industrial applications. Intended for use in combination with the MX 16, MX 32, MX43 or MX 256, the OLCT 10N provides a fast and accurate response. Up to 32 detectors can be connected on the same digital line or distributed on 8 lines. All transmitter information is received by the controller in less than 1 second. Non-intrusive operator interface requires only a simple magnetic wand and allows one man calibration without opening the enclosure, and calibration information, such as span reserve, is stored in the station. Certified IP65 and ATEX 3 GD for its explosive version, it is authorized for use in ATEX zones 2 and 22 and is waterproof and dustproof. Accessories Shock guard protector (2123717) OLCT 10N calibration tool kit (6331163) The OLCT 10N is the ideal solution for safe areas or zone 2 (22) ATEX locations. Configuration example Features: Detection of combustible gases, toxic gases or oxygen Digital technology Non-intrusive calibration Cost savings on wiring installation Applications: Cold rooms Car parks Technical features: Détecteur numérique OLCT 10N Range CH4, C3 H8, C4 H10, H2 O2 (> 2 years) O2 (5 years) CO H2S NO NO2 NH3 CO2 0-100 % LIE (-20°C à + 55°C) 0-30 % vol (-20°C à + 50°C) 0-30 % vol (-40°C à + 50°C) 0-300 ppm / 0-1000 ppm (-20°C à + 50°C) 0-30 ppm / 0-100 ppm (-20°C à + 50°C) 0-100 ppm / 0-300 ppm (-20°C à + 50°C) 0-10 ppm / 0-30 ppm (-20°C à + 50°C) 0-100 ppm / 0-1000 ppm (-20°C à + 40°C) 0-5000ppm / 0-5% vol / 0-100% vol (-40 à + 50°C) Output RS485 Modbus, proprietary protocol Power supply 12-30 Vcc Consumption Electrochemical sensor: Catalytic sensor : CO2 Infrared sensor: 2.5 mA in normal operation @ 24 Vdc 50 mA in normal operation @ 24 Vdc 20mA in normal operation @24Vdc Calibration Non-intrusive Cable inlet 2 PE M16, diamètre 4 à 8 mm Cable inlet With MX 32 (24 Vdc version): Up to 8 toxic or oxygen gas detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Up to 8 explosive gas detectors at 225 m with a 0.9 mm² (AWG 18) core size cable With MX 43: 2 x M16 cable entries, outer diameter 4 to 8 mm Up to 32 detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Dimensions (LxHxW) 118x110x60 mm Materials ABS, UV and shocks resistant Ingress protection IP65 Approvals for ATEX explosive versions II 3 GD Ex nA nC IIC T4 Gc for explosimetric versions Ex tc IIIC T135°C Dc -20°C<Ta<+55°C Electromagnetic compatibility according to EN50270 Ordering Information Part Number Description OLCT10N-001 Digital transmitter OLCT 10N, range 0-100% LEL CH4 OLCT10N-003 Digital transmitter OLCT 10N, range 0-100% LEL H2 OLCT10N-004 Digital transmitter OLCT 10N, range 0-100% LEL C4 H10 OLCT10N-005 Digital transmitter OLCT 10N, range 0-100% LEL C3 H8 OLCT10N-200 Digital transmitter OLCT 10N, range 0-30% vol O2 (2 year O2 sensor) OLCT10N-272 Digital transmitter OLCT 10N, range 0-30% vol O2 (5 year O2 sensor) OLCT10N-204 Digital transmitter OLCT 10N, range 0-300 ppm CO OLCT10N-205 Digital transmitter OLCT 10N, range 0-1000 ppm CO OLCT10N-213 Digital transmitter OLCT 10N, range 0-30 ppm H2S OLCT10N-214 Digital transmitter OLCT 10N, range 0-100 ppm H2S OLCT10N-216 Digital transmitter OLCT 10N, range 0-100 ppm NO OLCT10N-217 Digital transmitter OLCT 10N, range 0-300 ppm NO OLCT10N-219 Digital transmitter OLCT 10N, range 0-10 ppm NO2 OLCT10N-220 Digital transmitter OLCT 10N, range 0-30 ppm NO2 OLCT10N-231 Digital transmitter OLCT 10N, range 0-100 ppm NH3 OLCT10N-232 Digital transmitter OLCT 10N, range 0-1000 ppm NH3 OLCT10N-252 Digital transmitter OLCT 10N, range 0-5000 ppm CO2 OLCT10N-239 Digital transmitter OLCT 10N, range 0-5% vol CO2 OLCT10N-241 Digital transmitter OLCT 10N, range 0-100% vol CO2 Product Data Sheet -
Oldham Simtronics OLCT 20 Fixed Gas Detector
The OLCT 20 series sensors are designed for initial assembly applications, which can be installed in shelters, on skids, for monitoring in very small spaces or for on-board applications. They are mounted via M25 or 3/4" NPT threads or a special accessory to ensure a robust mounting without the need for an additional junction box. The OLCT 20 transmitters provide a 4-20mA output that can be directly connected to PLCs with a maximum current consumption of 100mA at 24VDC. They are certified ATEX explosion-proof by INERIS. Their IIC T6, makes them perfectly suited for the detection of hydrogen. The stainless steel detectors offer protection and resistance to corrosive agents. IP 66 rated, they are resistant to dust and water splashes. The OLCT 20's pre-calibrated sensors can be disconnected from the holder by rotation. These "smart" sensors can be calibrated on a workbench, outside of hazardous areas. Catalytic oxidation sensors for combustible gases are specially treated to resist poisons. They benefit from extremely fast response times and total reliability. Features Stainless steel base Small size Atex certification for H2 applications Pre-calibrated sensor Applications Machine Shelter Small spaces Mobility Refrigeration industry Water treatment Sensor specifications Accessories: 1 Tool kit (6147869) 2 Calibration cup (6331141) allows introduction of calibration gas on the sensor 3 Bypass adapter (6327910) allows measurement of samples 4 Splash guard system (6329004) protects the detector from liquid projections 5 Remote gas introduction head (6327911) allows gas injection without having to access the sensor 6 Removable protective filter (6335975) protects the sensor against projections and dust 7 Wall mounted collecting cone (6331169) for use with lighter-than-air gases 8 Pitot tube (6793322) Specifications Type XP transmitter Gas detection principle Catalytic/Electrochemical / Catharometric Detected gases Flammable, toxics and oxygen Measuring range see chart Sensor housing Stainless steel type 316L Precalibrated sensor YES Power supply at the detector 15 to 30 VDC Maximum power consumption 100 mA (catalytic) Output signal 4-20 mA Wiring 3 reinforced wires (catalytic) Load impedance 250 Ω (catalytic) Depending on power supply (chemical) Wiring connection delivered with a 6 mm-diameter cable Mounting M25 thread or 3/4" NPT or via accessory Ingress protection IP66 Certification II 2 GD Ex db IIC T6 Gb Ex tb IIIC T85°C Db T.Amb: -20°C to 70°C INERIS 01 ATEX 0004X EMC Marking EN 50270:2015 (type 2) Weight 800 g Dimensions L 130 x D 60 Operating temperature (for electronics) -25°C to +60°C Product Data Sheet -
Oldham Simtronics OLCT 60 Fixed Gas Detector
The generation of high quality gas detectors designed for the detection of flammable, toxic gases or oxygen. The OLCT 60 Series is available in several versions: Explosion-proof XP or intrinsically safe IS sensor (combustible, toxic or oxygen versions). Remote or on-board sensor. The OLCT 60 can be remotely mounted, allowing detection in inaccessible locations or in Zone 0 or 20 in the case of the intrinsically safe (IS) version. The OLCT 60 is equipped with a local display and non-intrusive access to a safe menu. In hazardous areas, calibration can be done without the need of a hot work permit. The detector units are made of 316L stainless steel, and are rugged and resistant to corrosion. Certified IP66, the OLCT 60 is sealed against dust and splash water. The versatile instrument is the ideal solution for gas detection covering all industrial needs for a wide variety of applications. Features Pre-calibrated sensors Non-intrusive calibration Infrared Version Infrared sensor available An infrared sensor is already available for CO2, SF6 and refrigerant gases detection. Sensors technical specifications: XP Transmitter with XP sensor: Sensor Catalytic / Electrochemical / Semi conductor / Infrared Detected gases Explosive or toxic gases, O2, VOC and refrigerant Material Epoxy coated aluminium + 316 stainless steel sensor Pre-calibrated block Yes Power supply 16 to 30 V DC Average consumption 140 mA (catalytic) 80 mA (electrochemical) 120 mA (infrared sensor) Output signal 0 - 23 mA (4-20 mA reserved for measurement) Cable 3 active wires, shielded cable Max. cable loop resistance / length Catalytic: 32 Ω / 1 km at 1.5 mm2 (16 AWG) Electrochemical and XP IR: 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) Ingress protection IP 66 Approvals OLCT60D (with integrated cell): ATEX II 2 GD Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 60°C OLCT60D d (with remote cell): ATEX II 2 GD Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 70°C (for the detector) ATEX II 2 GD - Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 70°C (for the remote cell) Electromagnetic compatibility according to EN50270 Weight 2.1 kg Dimensions 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches Operating temperature -20°C to +60°C XP transmitter with IS sensor: Sensor Electrochemical Detected gases Toxic gases or O2 Material Epoxy coated aluminium + 316 stainless steel sensor Pre-calibrated block Yes Power supply 16 to 30 V DC Average consumption 80 mA Output signal 0 - 23 mA (4-20 mA reserved for measurement) Cable 3 active wires, shielded cable Max. cable loop resistance / length with OLDHAM controller 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) Ingress protection IP 66 Approvals OLCT60id (with integrated cell): ATEX II 2 GD - Ex db [ia Ga] ia IIC T4 Gb - Ex tb [ia Da] ia IIIC T135°C Db Ambient temperature: -20°C to 60°C OLCT60D id: (with remote cell) ATEX II 2 (1) GD - Ex db [ia Ga] IIC T4 Gb - Ex tb [ia Da] IIIC T135°C Db Ambient temperature: -20°C to 60°C (for the detector) ATEX II 1 GD - Ex ia IIC T4 Ga - Ex ia IIIC T135°C Da Ambient temperature: -20°C to 70°C (for the remote cell) Electromagnetic compatibility according to EN 50270 Weight 2.1 kg Dimensions 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches Operating temperature -20°C to +60°C Accessories: A Calibration cup (6331141) allows introduction of calibration gas on the sensor B Bypass adapter (6327910) allows measurement of samples C Splash guard system (6329004) protects the detector from liquid projections D Remote gas introduction head (6327911) allows introduction of gas without opening the detector E Removable protective filter (6335975) protects the sensor against projections and dust F Duct measurement kit (6793322) allows gas monitoring in a duct G Mounting bracket (6322420) allows the mounting of the detector to the ceiling H Protective cover (6123716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6793718) allows the replacement of another OLDHAM detector without re-drilling J Wall mounted collecting cone (6331169) for use with lighter-than-air gases K Ceiling mount collecting cone (6331168) for use with lighter-than-air gases L Tool kit (6147877) Product Data Sheet -
Oldham Simtronics OLCT 80 Fixed Gas Detector
Features Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Remote versions available XP, IS Integrated relays Direct link, 4-20 mA, loop and isolated sensor mode Unique advantages providing the solution you need Design advantages Pre-calibrated sensors for detection of: combustible gases: LEL catalytic and IR toxic gases oxygen Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Inputs Series 80 sensors have up to 9 glands dedicated to cable wiring Design advantages: The minimum configuration includes: 1 electrical input dedicated to a sensor. two 4-20 mA or binary inputs. This configuration allows any other sensor from the network to be recognized (e.g temperature sensor, emergency stop, flame detector, smoke detector). Outputs 4/20 mA with smart signal processing analog signal 4-20 mA data signals between 0 and 4 - 20 and 25mA The transmitted signal, between 0 and 3.2 mA and above 20 mA, can be processed to interpret and identify a wide range of trouble parameters such as: line faults, sensor faults, embedded electronics faults, ambiguity resolution, inhibition of calibration, maintenance call (initial drift or drift over time). RS485 (1200 bauds, 38kb Modbus ASCII for MX 62). The RS485 link gives access to : - sensor measurement - status and default - internal relay management Relays The relays are 2A / 250 VAC type with potential free SPDT contacts. Two types of relays: 2 gas alarm relays or supplementary inputs 1 fault relay The relays are actuated either directly by the sensor electronics or supplementary inputs, or from the MX62 central unit or the control system to which the sensor is connected. The relays can be in safety mode or not, triggered on increasing or decreasing alarms, manually* or automatically acknowledged. * By remote control, by pressing an external pushbutton connected to the dedicated binary input, by acknowledging on the MX 62 unit or the control system to which the sensor is connected. Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Technical advantages Stand-alone central unit For relay control, the OLCT 80 can operate as a standalone unit: an indisputable advantage in a classified explosion risk zone. Flexibility of connection modes OLCT 80 sensors can be connected either: in loop (opto-isolated - up to 16 sensors), 4-20 mA, under direct power and operate as a central unit. Operation traceability The operator can check records locally for the most recent time-date stamped events. Communication Remote dialogue with the sensor using IR remote control. Measurement power supply redundancy Independent ports allow a redundant connection to the measurement unit. Low power requirements The leading edge technology used in the OLCT80 transmitter makes it very energy efficient. This major advantage means that more sensors can be connected, with smaller wire cross-sections and over greater distances. Logistic advantages Loop arrangement The transmitter is perfectly adapted to mounting and connection to the digital fieldbus loop of the MX 62 unit. Supporting 1 to 3 digital addresses: the sensor block (detection element), the two 4-20 mA auxiliary inputs. Certification The OLCT80 Series is certified to the specifications required by standards EN 50054, 45544 and 50104 (environmental standards, explosive and toxic gases and oxygen) and to the specifications of standards EN 50270, EN 6052 (electromagnetic compatibility, ingress protection). OLCT 80 uses digital logic and software technologies. The sensors are protected and in compliance with the specifications of standard EN 51271: analog and digital values track each other homogeneity of digital resolution and response time with the specifications required internal self-diagnostics Configuration Options Stand Alone Version Standard Version Stand Alone Version Specifications Type Transmitter-sensor Detected gases Explosive, toxic and oxygen Detection principles Catalytic, Electrochemical, IR, Semiconductor Sensor block Pre-calibrated Device Aluminium enclosure and stainless steel 316Lfor sensor housing Visualisation 4-digit LCD display for measurement and one alphanumeric line for texts, Pictograms - backlighting 4 indicator lamps : one green : "OperationOK", one yellow : "Fault", red : "Alarm 1" and "Alarm 2" Power supply From 16 to 28 VDC at transmitter entry Maximum power with digital link - 0.2 W (electrochemical cell) - 1.3 W ( catalytic / SM ) with I output at 25 mA - 0.9 W (electrochemical cell) - 2 W ( catalytic / SM ) with I output at 25 mA and relays activated - 2.4 W (electrochemical cell) - 3.5 W ( catalytic / SM ) Power supply to sensor terminals Two independent inputs : 16 to 28 VDC (catalytic / IR / SM cells) 12 to 28 VDC (electrochemical cell) Inputs Two analog inputs 4-20 mA (load resistance 120 Ω, can be used as binary) Signal outputs Logic (relay contacts) Relay Analog Standardised 4-20 mA output Digital Two independent opto-isolated RS 485 ports Signal faults I < 0.5 mA Alarms 2 programmable thresholds per channel Relays Type SPDT Number 3 Contact RCT changer-over Breaking capacity 2A / 250 VAC / 30 VDC Wiring / connection Basic version, 6 inputs : 4 M20 and 2 M25 On request : 3 additional, 2 M20 and 1 M25 Load resistance on the 4-20 mA 500 Ω Loop resistance Under central unit 21 VDC: 128 ohms ( electrochemical cell ) - 32 Ω ( catalytic / SM ) - 16 Ω (IR) Protection number IP 66 Operating temperatures - 20 °C to + 60 °C ( electronics, see table for detection cells ) Dimensions See drawings Weight OLCT 80 : 3,5 kg, OLCT80 version IR : 5,3 kg Accessories A Infrared remote control B Tool kit C Bypass adapter D Cover key E Calibration cup F Remote gas introduction device G Gas collector H Splash guard Homologations Certification Atex OLCT 80 d OLCT 80 id ATEX II 2GD ATEX II 2GD Ex d IIC T6...T5 Gb Ex d ia IIC T4 Gb Ex tb IIIC T85°C...T100°C Db Ex tb ia IIIC T135°C Db INERIS 03ATEX0240X INERIS 03ATEX0240X Chine OLCT 80 d OLCT 80 id GYJ17.1201X - Ex d IIC T6/T5 Gb GYJ17.1202X - Ex d ia IIC T4 Gb Electromagnetic compatibility Complies with EN 50270 Product Data Sheet -
Oldham Simtronics OLCT10 Toxic Gas Detector
Designed for commercial applications, OLCT 10 detector perfectly suit the protection of equipment and personnel in presence of combustion and exhaust gases or refrigerants (freons) in ambient air. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Electrochemical and semiconductor sensors 4-20 mA output signal Dust and humidity resistant (IP65) Fast and accurate response Up to 5 detectors on same line (CO, NO, NO2) Applications: Cold rooms Car parks Wiring of 1 OLCT 10 detector Wiring in parallel of 2 OLCT 10 detecting same gas (CO, NO or NO2) Wiring of 1 OLCT 10 SC (with a semi-conductor cell) Dimensions: Technical features: Electrochemical sensor Semiconductor sensor Range CO (0-300 ppm), NO (0-100 ppm), NO2 (0-30 ppm) R134a, R404a, R22, R410a etc. Signal output Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Settings Without opening the enclosure by means of 2 potentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Power Supply 15 to 30 Vdc (nominal 24 Vdc) 15 to 30 Vdc (nominal 24 Vdc) Consumption 30 mA max. 100 mA max. Cabling 2-wire, shielded, core size 0.9mm2 2 cable gland M16 (outer 4 to 8 mm) 3-wire, shielded, core size 0.9mm2 1 cable gland M16 (outer 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP rating IP65 IP65 Expected Lifespan 24 to 48 month, depending gas to detect > 24 months Operating temperature -20 to +55°C -20 to +55°C Operating humidity 15% HR to 90% HR 20% HR to 90% HR Pressure range 1 bar ± 10 % 1 bar ± 10 % Response Time NO2: T90 < 60s, NO : T90 < 120 CO : T50 < 15s, Fréon R134A : T50 < 30s Certification Electromagnetic compatibility according to EN 50270:2015 (type2) Complies with EN 14624 for freon Product Data Sheet