pesales@pe-energy.com +1 ( 281 ) 310 – 0628

Oldham Simtronics CTX 300 Fixed Toxic Gas Detector

SKU: CTX-300
Manufacturer:
Oldham Simtronics

Bulk Orders

Competitive Pricing
Short Lead Times
Consolidated Shipping
Prompt Response
Request a Quote

Presentation
The CTX 300 can detect O2, CO2, toxic and refrigerant gases. TELEDYNE Gas & Flame Detection offers a detector version with a wide range of sensors (infrared, electrochemical, semiconductor) according to your application needs. It is also available with or without display.

Simplicity
Sensor replacement does not require any special menu access. Just replace the sensor without even powering down the transmitter!

Reduced maintenance
As the only consumable element, the CTX 300 sensor is easily replaceable. New sensors come pre-calibrated from the factory. So during the sensor ex-change, no calibration gas is required, nor adjustments to the detector, or remote central controller are required.

FEATURES:

  • Detection of toxic gases or oxygen
  • Interchangeable and pre-calibrated sensor modules
  • Local display (optional)
  • Durable in harsh environments
  • Up to 5 years of life for O2 sensor

 

PART NUMBER GAS TYPE OF SENSOR RANGE (ppm) OPERATING TEMPERATURE
WC3oO2F O2 Electrochimic 30.0 % -20 °C la +50 °C
WC30O2G 30.0 % -40 °C to +50 °C
WC3AO2G 30.0 % -20 °C to +50 °C
WC3oO2S 100 % +5 °C to +40 °C
WC3oCOA CO Electrochimic 100 -20 °C to +50 °C
WC3oCOB 300 -20 °C to +50 °C
WC3oCOC 1000 -20 °C to +50 °C
WC3oCOD 1.00 % -20 °C to +50 °C
WC3oCO2A CO2 Infrarosu 0.50% (5000ppm) -40 °C to +50 °C
WC3oCO2B 5.00 % -40 °C to +50 °C
WC3oCO2C 100 % -40 °C to +50 °C
WC3oHSA H2S Electrochimic 30.0 -20 °C to +50 °C
WC3oHSB 100 -20 °C to +50 °C
WC3oHSC 1000 -20 °C to +50 °C
WC3oNOA NO Electrochimic 100 -20 °C to +50 °C
WC3oNOB 300 -20 °C to +50 °C
WC3oNOC 1000 -20 °C to +50 °C
WC3oN2A NO2 Electrochimic 10.0 -20 °C to +50 °C
WC3oN2B 30.0 -20 °C to +50 °C
WC3oSOA SO2 Electrochimic 10.0 -20 °C to +50 °C
WC3oSOB 30.0 -20 °C to +50 °C
WC3oSOC 30.0 -20 °C to +50 °C
WC3oCL2 Cl2 Electrochimic 10.0 -20 °C to +50 °C
WC3oH2A H2 Electrochimic 2000 -20 °C to +50 °C
WC3oH2B 2 % -20 °C to +50 °C
WC3oHLA HCl Electrochimic 30.0 -20 °C to +50 °C
WC3oHLB 100 -20 °C to +50 °C
WC3oHNA HCN Electrochimic 10.0 -20 °C to +50 °C
WC3oHNB 30.0 -20 °C to +50 °C
WC3oNH3 NH3 Electrochimic 100 -20 °C to +40 °C
WC30NH3F 100 -40 °C to +40 °C
WC3oNH1 1000 -20 °C to +40 °C
WC30NH1F 1000 -40 °C to +40 °C
WC30NH2 5000 -20 °C to +40 °C
WC3oOET ETO/PO Electrochimic 30.0 -20 °C to +50 °C
WC3oHFA HF Electrochimic 10.0 -10 °C to +30 °C
WC3oO3A O3 Electrochimic 1.00 -20 °C to +50 °C
WC3oPH3 PH3 Electrochimic 1.00 -20 °C to +50 °C
WC3oCLO ClO2 Electrochimic 3.00 -20 °C to +50 °C
WC3oCCL COCl2 Electrochimic 1.00 -20 °C to +40 °C
CTX300-507 Methylene chloride Semiconductor 500 -20 °C to +55 °C
CTX300-508 Methyl chloride Semiconductor 500 -20 °C to +60 °C
CTX300-657 Toluene Semiconductor 500 -20 °C to +50 °C
CTX300-660 Xylene Semiconductor 500 -20 °C to +55 °C
CTX300-656 Ethanol Semiconductor 500 -20 °C to +50 °C
CTX300-500 R12 Semiconductor 10000 -20 °C to +55 °C
CTX300-501 R22 Semiconductor 2000 -20 °C to +55 °C
CTX300-509 R123 Semiconductor 2000 -20 °C to +55 °C
CTX300-502 R134a Semiconductor 2000 -20 °C to +55 °C
CTX300-505 R11 Semiconductor 10000 -20 °C to +55 °C
CTX300-506 R23 Semiconductor 10000 -20 °C to +55 °C
CTX300-511 R143a Semiconductor 2000 -20 °C to +55 °C
CTX300-521 R245fa Semiconductor 1000 -20 °C to +55 °C
CTX300-512 R404a Semiconductor 2000 -20 °C to +55 °C
CTX300-513 R507 Semiconductor 2000 -20 °C to +55 °C
CTX300-514 R410a Semiconductor 1000 -20 °C to +55 °C
CTX300-515 R32 Semiconductor 1000 -20 °C to +55 °C
CTX300-525 HFO-1234ze Semiconductor 1000 -20 °C to +55 °C
CTX300-662 HFO-1234yf Semiconductor 1000 -20 °C to +55 °C

 

PART NUMBER ACCURACY (% at PA FULL SCALE) LIFE SPAN (IN MONTHS) T(50) (SECONDS)
WC3oO2F +/- 1.5 % 28 10
WC30O2G +/- 1.5 % 60 10
WC3AO2G +/- 1.5 % 60 10
WC3oO2S +/- 1.5 % 36 < 20
WC3oCOA +/- 1.5 % 48 15
WC3oCOB +/- 1.5 % 48 15
WC3oCOC +/- 1.5 % 48 15
WC3oCOD +/- 1.5 % 48 < 20
WC3oCO2A +/- 2 % 60 <20
WC3oCO2B +/- 2 % 60 <20
WC3oCO2C +/- 2 % 60 <20
WC3oHSA +/- 1.5 % 36 15
WC3oHSB +/- 1.5 % 36 15
WC3oHSC +/- 1.5 % 36 15
WC3oNOA +/- 1.5 % 36 15
WC3oNOB +/- 1.5 % 36 15
WC3oNOC +/- 1.5 % 36 15
WC3oN2A +/- 1.5 % 24 20
WC3oN2B +/- 1.5 % 24 20
WC3oSOA +/- 1.5 % 36 15
WC3oSOB +/- 1.5 % 36 15
WC3oSOC +/- 1.5 % 36 15
WC3oCL2 +/- 1.5 % 24 50
WC3oH2A +/- 1.5 % 24 50
WC3oH2B +/- 1.5 % 24 50
WC3oHLA +/- 1.5 % 24 50
WC3oHLB +/- 1.5 % 24 50
WC3oHNA +/- 2 % 18 30
WC3oHNB +/- 2 % 18 30
WC3oNH3 +/- 3 % 24 <20
WC30NH3F +/- 3 % 24 <20
WC3oNH1 +/- 3 % 24 <20
WC30NH1F +/- 3 % 24
WC30NH2 +/- 3 % 24 <20
WC3oOET +/- 3 % 36 50
WC3oHFA +/- 3 % 12 50
WC3oO3A +/- 3 % 18 40
WC3oPH3 +/- 3 % 12 40
WC3oCLO +/- 2 % 24 50
WC3oCCL +/- 1.5 % 18 50
CTX300-507 +/- 15 %
relative
to alarm threshold
36 40
CTX300-508 36 40
CTX300-657 36 20
CTX300-660 36 20
CTX300-656 36 20
CTX300-500 36 30
CTX300-501 36 30
CTX300-509 36 30
CTX300-502 36 30
CTX300-505 36 30
CTX300-506 36 30
CTX300-511 36 30
CTX300-521 36 30
CTX300-512 36 30
CTX300-513 36 30
CTX300-514 36 20
CTX300-515 36 20
CTX300-525 36 30
CTX300-662 36 30
Oldham Simtronics CTX 300 Fixed Toxic Gas DetectorOldham Simtronics CTX 300 Fixed Toxic Gas Detector

 

Clear readability

  • Highly sensitive, lighted display allows local reading
  • Effective power-up indication by indicator lights
  • Indication of maintenance or fault function by LED

High-Level technology

  • Pre-calibrated sensor avoiding the need to use unstable gases on site for calibration purposes
  • High-performance semiconductor type detector (detection of freon gas, etc.)
  • Available in an infrared version for CO2

Advanced design

  • Highly resistant to environmental elements
  • Avoids having to use protective covers

Heavy-duty

  • Use of polycarbonate and stainless steel mounting hardware
  • Resistant to corrosive agents (H2S, HCl, sea spray,…)
  • Durable housing

Specifically adapted options

  • Removable filters, interchangeable without opening the housing (which is dust-proof, condensation-proof and water resistant)
  • Splash guard
  • Gas collector cone
  • Mounting brackets
  • Pitot tubes, floats, heating protective device, etc.
  • Remote calibration cup

Enclosure: Polycarbonate housing
Function: 4-20 mA output analog transmitter
Display: Highly visible backlight LCD display unit (optional, gas dependent)
Indicator lights: In operation: green color: Failure / maintenance: orange color
Wiring: 2 wires shielded cable for CTX300 without display 3 wires shielded cable for CTX300 with display
Cable entry: M16 cable gland (outer diameter 4 to 10 mm)
Power supply: 15 to 32 V DC
Maximum Power Consumption: CTX 300 without display unit: 60 mA, CTX 300 with display unit: 110 mA, CTX 300 without display semiconductor versions: 100mA
Operating temperature: without display: -40°C to +50°C (-40°F to +122°F), sensor dependent with display: -20°C to +50°C (-4°F to +122°F), sensor dependent
Sealing: IP 54, NEMA 3 & 3R
Weight: 520 g (18.2 oz)
Certification: EMC according to EN 50270:06 CSA CLASS 812 86, CLASS 4812 06 (SIGNAL APPLIANCES) all versions exept CO2 versions
Impedance: 32 ohms max loop for CTX 300 with display unit and for semiconductors sensor versions, 64 ohms max loop for CTX 300 without display unit

Oldham Simtronics CTX 300 Fixed Toxic Gas Detector

Product Data Sheet

Reviews

There are no reviews yet.

Be the first to review “Oldham Simtronics CTX 300 Fixed Toxic Gas Detector”

Popular Brands