Design for commercial applications, OLC and OLCT10 detectors perfectly suit the protection of equipment and personnel in boiler or charging rooms where atmosphere may contain flammable gases.
Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements.
Features:
- Catalytic sensors
- 4-20mA output signal with OLCT 10
- Dust and humidity resistant
- Fast and accurate response
- ATEX Approval for use in hazardous areas (zone 2 and 22) OLC10 and OLC10 TWIN
- OLC 10 TWIN allows connection of 2 sensors with a single channel without any additional junction box.
Applications:
- Boiler rooms
- Charging rooms
Wiring arrangement between OLC(T) 10 and MX 32 control unit
Wiring arrangement between OLC 10 TWIN and MX 32 control unit
Dimensions:
Technical features:
OLC 10 / OLC 10 TWIN | OLCT 10 (Catalytic) | |
Range | Combustible gases – 0 to 100% LEL , Methane, Butane, Propane, LPG, Natural Gas or H2 | Combustible Gases – 0 to 100% LEL Methane, Butane, Propane, GPL, Natural Gas or H2 |
Signal output | Wheatstone Bridge | Normal operation 4-20 mA (Fault < 0.5 mA or > 23.2 mA) |
Settings | Managed by control unit | Without opening the enclosure by means of 2 petentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Set to 23.2 mA if value > 100% LEL according to European standard EN 61779-4 Disable on request when managed by a suitable controller |
Consumption | See on the manual of the controller | 100 mA max |
Cabling | OLC 10 : 3 Wire, shielded, core size 1,5 mm2 max. cable length 300 m 1 cable-gland M16 (outer \ 4 to 8 mm)OLC10 TWIN : shielded, core size 1,5 mm2, 3-wire to control unit, 4-wire between both sensors, max. cable length 300 m, 2 cable-glands M16 (outer \ 4 to 8 mm) |
3-wire, shielded, core size 1,5 mm2, max. cable length 1km if connected with control unit (32 W max un loop) 1 cable gland M16 (outer \ 4 to 8 mm) |
Dimensions (LxHxP) | 118 x 126 x 63 mm | 118 x 126 x 63 mm |
Material | ABS | ABS |
IP Rating | IP65 | IP65 |
Expected lifespan | 36 to 48 months (sensor) | 36 to 48 months (sensor) |
Operating temperature | -10 to + 45 °C | -10 to + 45 °C |
Operating humidity range | -20 to +55°C | -20 to +55°C |
Pressure Range | 1 bar ± 20 % | 1 bar ± 20 % |
Response Time | Flammable gas : < 10s | Flammable gas : < 10s |
Accuracy | +/- 3% LEL | +/- 3% LEL |
Certification | EN 50270:2015 (type2) ATEX II 3 GD / Ex ec dc IIC T6 Gc Ex tc IIIC T85°C Dc |
EN 50270:2015 (type2) |
Be the first to review “Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector” Cancel reply
Related products
-
Oldham Simtronics DG-TT7-S Solid-State (MOS) Gas Detector
The MultiTox DG-TT7-S is a solid state (MOS) based smart gas detector for the detection of Hydrogen Sulphide. The device has been designed to withstand harsh environment and provide easy operation The unit is fully configurable using a wireless hand-held terminal TLU, using a magnet or by using HART protocol option. The configuration of the outputs is adjustable using the TLU or the magnet that can be used in areas classified as potentially explosive. The MultiTox DG-TT7-S is SIL2 certified, 3 on board relays in option, plug and play sensors and a high visible display that changes colour depending on the status mode. The unit may be interfaced directly with a wide range of centrals and PLC’s. The device supports HART 7 protocol option for full configuration and diagnostics over non-proprietary interface. This new version also offers automatic calibration, TELECAPTEUR Calibration Management Software. It allows loading, comparison and logging of the last calibrations carried out and this can be done by one person only. (one man calibration) Features High visible display Display color is status dependent Ideal for Desert & Artic Environments Technical data General: Technology Solid-state Metal Oxide Semiconductor Detects Hydrogen Sulphide Range 0-20 ppm H2S 0-50 ppm H2S Performance: Accuracy +/- 2 ppm or +/- 10% reading Zero drift <1 ppm Sensor life Better than 5 years (environment dependant) Output signal: Standard 0-22mA encoded: * 0-4mA: fault mode, calibration, inhibit (current values are user configurable) * 4-20 mA: measurement * 22mA: overange Max. load impedance 700 Ohms Options HART Protocol (Version 7) 3 configurable dry contact relay outputs, max 1A / 30V Lonworks (Syntel) Local display 4 digit, ultrabright LED display, color change background according to the status (green=normal operation, amber=Fault mode, red=Gas Alarm, purple=Inhibit/Warm-Up mode), self adjust backlight depending on luminosity Electrical: Power supply 24V DC, range (18 - 35V DC) Power consumption 2W normal (5W max) Connection 0.3 mm2 (22 AWG) - 2.5 mm2 (14 AWG) 3 wire shielded cable Environmental: Storage -40°C to +65°C (-40°F to +149°F) Operation -40°C to +65°C (-40°F to +149°F) Option Sunshade, max. temp. 85°C (185°F) Humidity 99% RH (non-condensing) Pressure Atmospheric pressure +/- 10% Ingress IP66 RFI /EMI Complies with EN50270 Housing: Material 316L stainless steel Weight 4 Kg (8Lbs) Approvals: ATEX II 2 G Ex d IIC T6 Gb or Ex db IIC T6 (-40°C to +65°C / -40°F to +149°F) IECEx Ex d IIC T6 Gb or Ex db IIC T6 SIL SIL2 approved by 3rd party Accessories: TLU600 Infrared remote control unit AS056-250 Sun shade AS005 Calibration cup AS047 Display protection AS011-2 Sample flow housing AS019 Splash guard CAL-K1C-xxAE-1 A1 -00 Calibration kit 20ppm H2S CAL-K1C-31AF-1A1-00 Calibration kit 50ppm H2S CAL-TUBE-H2S-MOS In-line humidifying tube for calibration Other products (stainless steel range): DG-TT7-E MultiTox, Toxic Gas Detector DF-TV7 or -V MultiFlame, Flame Detector DG-TX7-X MultiXplo, Flammable Gas Detector Product Data Sheet -
Teledyne Detcon IR-700-CH Combustible Gas Sensor
Model IR-700-CH is a non-intrusive “Smart” sensor designed to detect and monitor combustible hydrocarbon gases in air over the range of 0-100% LEL using miniature non-dispersive Infrared Optical (NDIR) sensor technology. As compared to catalytic bead sensors, with NDIR there is no risk of sensor poisoning, no risk of high concentration saturation, and no need for O2 to be present. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The IR-700-CH’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CH is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR-700-CH is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 5-year warranty. Order Guide Specify junction box options (below) PN 967-215520-100 - IR-700-CH Sensor Assembly (no junction box) PN 967-211520-100 - IR-700-CH Sensor Assembly with Aluminum Junction Box PN 967-214520-100 - IR-700-CH Sensor Assembly with 316 SS Junction Box PN 9H7-211520-100 - IR-700-CH Sensor Assembly with HART, Alumium Junction Box PN 9H7-214520-100 - IR-700-CH Sensor Assembly with HART, 316 SS Junction Box PN 9R7-211520-100 - IR-700-CH Sensor Assembly with RAM, Aluminum Junction Box PN 9R7-214520-100 - IR-700-CH Sensor Assembly with RAM, 316 SS Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants GAS DETECTED: Methane Ethane Propane Butane Pentane Hexane Ethylene Gasoline Vapor Diesel Fuel Vapor Jet Fuel Vapor For other gases consult the factory FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Non-dispersive Infrared Optical (NDIR) - Combustible Gas Sub-miniature plug-in field replaceable Sensor Life 5 years typical Measurement Range 0-100% LEL (lower explosive limit) 0-100% by volume Accuracy ±2% F.S. (0-50% LEL) Repeatability ±2% F.S. Response Time* T50 < 6 seconds, T90 < 10 seconds Zero Drift (typical) ≤2% per 2 years Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUS Performance to ISA 12.13.01-2000 and CSA 22.2 #152 ATEX CE Marking SIL2 Certified to IEC 61508 (ATEX version only) Warranty Plug-in detector - 5 years Transmitter - 2 Years * As tested with 1 lpm flowrate ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 0.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) HART Integration Module (HART Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon DM-700 Toxic Gas Detector
Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port APPLICATIONS: Oil & Gas Chemical Plants Food & Beverage Steel Mills Pulp and Paper Refineries Wastewater Treatment Plants Utilities PART NUMBER GAS MEASURING ACCURACY RESPONSE TIME 967-12EG91-100 Acetylene 0-100 ppm ±2% FS T90≤140 seconds 967-505091-100 Ammonia 0-100 ppm ±2% FS T90≤90 seconds 967-191991-001 Arsine 0-1 ppm ±2% FS T90≤60 seconds 967-747591-005 Bromine 0-5 ppm ±2% FS T90≤60 seconds 967-12EB91-100 Butadiene 0-100 ppm ±2% FS T90≤140 seconds 967-444491-100 Carbon Monoxide 0-100 ppm ±2% FS T50≤10 sec./ T90≤30 sec. 967-747491-010 Chlorine 0-10 ppm ±2% FS T90≤60 seconds 967-747691-050 Chlorine Dioxide 700 0-50 ppm ±2% FS T90≤120 seconds 967-777791-001 Chlorine Dioxide 701 0-1 ppm ±2% FS T90≤60 seconds 967-192191-005 Diborane 0-5 ppm ±2% FS T90≤60 seconds 967-12EO91-100 Ethanol 0-100 ppm ±2% FS T90≤140 seconds 967-12ED91-100 Ethylene (*See Note 2) 0-100 ppm ±2% FS T90≤140 seconds 967-12EJ91-100 Ethylene Oxide 0-100 ppm ±2% FS T90≤140 seconds 967-272791-001 Fluorine 0-1 ppm ±2% FS T90≤80 seconds 967-12EP91-100 Formaldehyde 0-100 ppm ±2% FS T90≤140 seconds 967-232591-002 Germane 0-2 ppm ±2% FS T90≤60 seconds 967-070791-01P Hydrogen (1%) 0-1% volume ±2% FS T90≤60 seconds 967-050591-04P Hydrogen (4%) 0-4% ±2% FS T90≤60 seconds 967-848491-100 Hydrogen PPM 0-100 ppm ±2% FS T90≤30 seconds 967-090891-030 Hydrogen Bromide 0-30 ppm ±2% FS T90≤70 seconds 967-090991-030 Hydrogen Chloride 0-30 ppm ±2% FS T90≤70 seconds 967-131391-030 Hydrogen Cyanide 0-30 ppm ±2% FS T90≤40 seconds 967-333391-010 Hydrogen Fluoride 0-10 ppm ±2% FS T90≤90 seconds 967-242491-100 Hydrogen Sulfide 0-100 ppm ±2% FS T50≤10 sec./ T80≤30 sec. 967-303091-100 Hydrogen Sulfide (DC)* 0-100 ppm ±10% applied gas concentration or ±3 ppm, whichever is greater T20 ≤ 20sec 967-303091-050 T50 ≤ 45 sec 967-303091-025 T90 ≤ 60 sec 967-12EE91-100 Methanol 0-100 ppm ±2% FS T90≤140 seconds 967-12EK91-100 Methyl Mercaptan 0-100 ppm ±2% FS T90≤45 seconds 967-949491-100 Nitric Oxide 0-100 ppm ±2% FS T90≤10 seconds 967-646491-010 Nitrogen Dioxide 0-10 ppm ±2% FS T90≤40 seconds 967-341520-025 Oxygen 0-25% volume ±1% FS T90≤10 seconds 967-393991-001 Ozone 0-1 ppm ±2% FS T90≤120 seconds 967-192091-005 Phosphine 0-5 ppm ±2% FS T90≤30 seconds 967-232391-050 Silane 0-50 ppm ±2% FS T90≤60 seconds 967-555591-020 Sulfur Dioxide 0-20 ppm ±2% FS T90≤20 seconds *Note: Acetylene can only be used with a Group A enclosure. *Note2: This product is a safety device to detect hazardous conditions, and is not intended for process control application in fruit ripening operations. *Note3: DC=Desert Climate Sensors are 3rd-party test report to ISA 92.00.01 2010 standard SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption 3-electrode electrochemical cell Plug-in field replaceable Intelligent Type Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CCSAUS Class I, Division 1, Groups B, C, D () Class I, Zone 1, Group IIC ATEX II 2 G Ex d ib IIB + H2 T4 GB Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUS ATEX CE Marking SIL2 Certified to IEC 61508 MECHANICAL SPECIFICATIONS: Dimensions 7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5"; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11 - 30 VDC Power Consumption Normal operation = 30mA @ 24V (<0.75 watt) Maximum = 50mA @ 24V (1.2 watts) Inrush Current 500mA @ 24V (typical) RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600, N, 8, 1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over -voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Oldham Simtronics CTX 300 Fixed Toxic Gas Detector
Presentation The CTX 300 can detect O2, CO2, toxic and refrigerant gases. TELEDYNE Gas & Flame Detection offers a detector version with a wide range of sensors (infrared, electrochemical, semiconductor) according to your application needs. It is also available with or without display. Simplicity Sensor replacement does not require any special menu access. Just replace the sensor without even powering down the transmitter! Reduced maintenance As the only consumable element, the CTX 300 sensor is easily replaceable. New sensors come pre-calibrated from the factory. So during the sensor ex-change, no calibration gas is required, nor adjustments to the detector, or remote central controller are required. FEATURES: Detection of toxic gases or oxygen Interchangeable and pre-calibrated sensor modules Local display (optional) Durable in harsh environments Up to 5 years of life for O2 sensor PART NUMBER GAS TYPE OF SENSOR RANGE (ppm) OPERATING TEMPERATURE WC3oO2F O2 Electrochimic 30.0 % -20 °C la +50 °C WC30O2G 30.0 % -40 °C to +50 °C WC3AO2G 30.0 % -20 °C to +50 °C WC3oO2S 100 % +5 °C to +40 °C WC3oCOA CO Electrochimic 100 -20 °C to +50 °C WC3oCOB 300 -20 °C to +50 °C WC3oCOC 1000 -20 °C to +50 °C WC3oCOD 1.00 % -20 °C to +50 °C WC3oCO2A CO2 Infrarosu 0.50% (5000ppm) -40 °C to +50 °C WC3oCO2B 5.00 % -40 °C to +50 °C WC3oCO2C 100 % -40 °C to +50 °C WC3oHSA H2S Electrochimic 30.0 -20 °C to +50 °C WC3oHSB 100 -20 °C to +50 °C WC3oHSC 1000 -20 °C to +50 °C WC3oNOA NO Electrochimic 100 -20 °C to +50 °C WC3oNOB 300 -20 °C to +50 °C WC3oNOC 1000 -20 °C to +50 °C WC3oN2A NO2 Electrochimic 10.0 -20 °C to +50 °C WC3oN2B 30.0 -20 °C to +50 °C WC3oSOA SO2 Electrochimic 10.0 -20 °C to +50 °C WC3oSOB 30.0 -20 °C to +50 °C WC3oSOC 30.0 -20 °C to +50 °C WC3oCL2 Cl2 Electrochimic 10.0 -20 °C to +50 °C WC3oH2A H2 Electrochimic 2000 -20 °C to +50 °C WC3oH2B 2 % -20 °C to +50 °C WC3oHLA HCl Electrochimic 30.0 -20 °C to +50 °C WC3oHLB 100 -20 °C to +50 °C WC3oHNA HCN Electrochimic 10.0 -20 °C to +50 °C WC3oHNB 30.0 -20 °C to +50 °C WC3oNH3 NH3 Electrochimic 100 -20 °C to +40 °C WC30NH3F 100 -40 °C to +40 °C WC3oNH1 1000 -20 °C to +40 °C WC30NH1F 1000 -40 °C to +40 °C WC30NH2 5000 -20 °C to +40 °C WC3oOET ETO/PO Electrochimic 30.0 -20 °C to +50 °C WC3oHFA HF Electrochimic 10.0 -10 °C to +30 °C WC3oO3A O3 Electrochimic 1.00 -20 °C to +50 °C WC3oPH3 PH3 Electrochimic 1.00 -20 °C to +50 °C WC3oCLO ClO2 Electrochimic 3.00 -20 °C to +50 °C WC3oCCL COCl2 Electrochimic 1.00 -20 °C to +40 °C CTX300-507 Methylene chloride Semiconductor 500 -20 °C to +55 °C CTX300-508 Methyl chloride Semiconductor 500 -20 °C to +60 °C CTX300-657 Toluene Semiconductor 500 -20 °C to +50 °C CTX300-660 Xylene Semiconductor 500 -20 °C to +55 °C CTX300-656 Ethanol Semiconductor 500 -20 °C to +50 °C CTX300-500 R12 Semiconductor 10000 -20 °C to +55 °C CTX300-501 R22 Semiconductor 2000 -20 °C to +55 °C CTX300-509 R123 Semiconductor 2000 -20 °C to +55 °C CTX300-502 R134a Semiconductor 2000 -20 °C to +55 °C CTX300-505 R11 Semiconductor 10000 -20 °C to +55 °C CTX300-506 R23 Semiconductor 10000 -20 °C to +55 °C CTX300-511 R143a Semiconductor 2000 -20 °C to +55 °C CTX300-521 R245fa Semiconductor 1000 -20 °C to +55 °C CTX300-512 R404a Semiconductor 2000 -20 °C to +55 °C CTX300-513 R507 Semiconductor 2000 -20 °C to +55 °C CTX300-514 R410a Semiconductor 1000 -20 °C to +55 °C CTX300-515 R32 Semiconductor 1000 -20 °C to +55 °C CTX300-525 HFO-1234ze Semiconductor 1000 -20 °C to +55 °C CTX300-662 HFO-1234yf Semiconductor 1000 -20 °C to +55 °C PART NUMBER ACCURACY (% at PA FULL SCALE) LIFE SPAN (IN MONTHS) T(50) (SECONDS) WC3oO2F +/- 1.5 % 28 10 WC30O2G +/- 1.5 % 60 10 WC3AO2G +/- 1.5 % 60 10 WC3oO2S +/- 1.5 % 36 < 20 WC3oCOA +/- 1.5 % 48 15 WC3oCOB +/- 1.5 % 48 15 WC3oCOC +/- 1.5 % 48 15 WC3oCOD +/- 1.5 % 48 < 20 WC3oCO2A +/- 2 % 60 <20 WC3oCO2B +/- 2 % 60 <20 WC3oCO2C +/- 2 % 60 <20 WC3oHSA +/- 1.5 % 36 15 WC3oHSB +/- 1.5 % 36 15 WC3oHSC +/- 1.5 % 36 15 WC3oNOA +/- 1.5 % 36 15 WC3oNOB +/- 1.5 % 36 15 WC3oNOC +/- 1.5 % 36 15 WC3oN2A +/- 1.5 % 24 20 WC3oN2B +/- 1.5 % 24 20 WC3oSOA +/- 1.5 % 36 15 WC3oSOB +/- 1.5 % 36 15 WC3oSOC +/- 1.5 % 36 15 WC3oCL2 +/- 1.5 % 24 50 WC3oH2A +/- 1.5 % 24 50 WC3oH2B +/- 1.5 % 24 50 WC3oHLA +/- 1.5 % 24 50 WC3oHLB +/- 1.5 % 24 50 WC3oHNA +/- 2 % 18 30 WC3oHNB +/- 2 % 18 30 WC3oNH3 +/- 3 % 24 <20 WC30NH3F +/- 3 % 24 <20 WC3oNH1 +/- 3 % 24 <20 WC30NH1F +/- 3 % 24 - WC30NH2 +/- 3 % 24 <20 WC3oOET +/- 3 % 36 50 WC3oHFA +/- 3 % 12 50 WC3oO3A +/- 3 % 18 40 WC3oPH3 +/- 3 % 12 40 WC3oCLO +/- 2 % 24 50 WC3oCCL +/- 1.5 % 18 50 CTX300-507 +/- 15 % relative to alarm threshold 36 40 CTX300-508 36 40 CTX300-657 36 20 CTX300-660 36 20 CTX300-656 36 20 CTX300-500 36 30 CTX300-501 36 30 CTX300-509 36 30 CTX300-502 36 30 CTX300-505 36 30 CTX300-506 36 30 CTX300-511 36 30 CTX300-521 36 30 CTX300-512 36 30 CTX300-513 36 30 CTX300-514 36 20 CTX300-515 36 20 CTX300-525 36 30 CTX300-662 36 30 Clear readability Highly sensitive, lighted display allows local reading Effective power-up indication by indicator lights Indication of maintenance or fault function by LED High-Level technology Pre-calibrated sensor avoiding the need to use unstable gases on site for calibration purposes High-performance semiconductor type detector (detection of freon gas, etc.) Available in an infrared version for CO2 Advanced design Highly resistant to environmental elements Avoids having to use protective covers Heavy-duty Use of polycarbonate and stainless steel mounting hardware Resistant to corrosive agents (H2S, HCl, sea spray,…) Durable housing Specifically adapted options Removable filters, interchangeable without opening the housing (which is dust-proof, condensation-proof and water resistant) Splash guard Gas collector cone Mounting brackets Pitot tubes, floats, heating protective device, etc. Remote calibration cup Enclosure: Polycarbonate housing Function: 4-20 mA output analog transmitter Display: Highly visible backlight LCD display unit (optional, gas dependent) Indicator lights: In operation: green color: Failure / maintenance: orange color Wiring: 2 wires shielded cable for CTX300 without display 3 wires shielded cable for CTX300 with display Cable entry: M16 cable gland (outer diameter 4 to 10 mm) Power supply: 15 to 32 V DC Maximum Power Consumption: CTX 300 without display unit: 60 mA, CTX 300 with display unit: 110 mA, CTX 300 without display semiconductor versions: 100mA Operating temperature: without display: -40°C to +50°C (-40°F to +122°F), sensor dependent with display: -20°C to +50°C (-4°F to +122°F), sensor dependent Sealing: IP 54, NEMA 3 & 3R Weight: 520 g (18.2 oz) Certification: EMC according to EN 50270:06 CSA CLASS 812 86, CLASS 4812 06 (SIGNAL APPLIANCES) all versions exept CO2 versions Impedance: 32 ohms max loop for CTX 300 with display unit and for semiconductors sensor versions, 64 ohms max loop for CTX 300 without display unit Product Data Sheet
Reviews
There are no reviews yet.