Teledyne Detcon FP-700 Combustible Gas Sensor
Bulk Orders
Model FP-700 is a non-intrusive “Smart” sensor designed to detect and monitor combustible gases in air over the range of 0-100% LEL using catalytic bead sensor technology. The plug-in, field replaceable detector is poison-resistant and features over-sized gold-plated connections that help prevent corrosion. The FP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model FP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model FP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), and HART. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty.
Order Guide Specify junction box options (below)
PN 967-525520-100 – FP-700 Sensor Assembly (no junction box)
PN 967-521520-100 – FP-700 Sensor Assembly with Aluminum Junction Box
PN 967-524520-100 – FP-700 Sensor Assembly with 316 SS Junction Box
PN 9H7-521520-100 – FP-700 Sensor Assembly with HART in Aluminum Junction Box
PN 9H7-524520-100 – FP-700 Sensor Assembly with HART in 316 SS Junction Box
PN 9R7-524520-100 – FP-700 Sensor Assembly with RAM in Aluminum Junction Box
PN 9R7-524520-100 – FP-700 Sensor Assembly with HART in 316SS Junction Box
APPLICATIONS:
- Oil and Gas Drilling Rigs
- Oil and Gas Production Sites
- Offshore Production Platforms
- FPSOs
- LNG/CNG Plants
- Refining and Petrochemical
- Pulp and Paper Mills
- Waste Water Treatment Plants
FEATURES:
Failsafe User-Friendly Interface
- LED Display (With Antiglare Cover)
- Full Text Display Method
- Non-intrusive Interface
- Auto Zero/Auto Span
- Pre-emptive Fault Diagnostics
Environmentally Bulletproof
- Electropolished 316SS Construction
- 100% Epoxy Encapsulated Circuitry
- Bulletproof I/O Protection
- Water-proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
- Modular Design
- Plug and Play Components
- Quick Thread Release Sensor Endcap (Allen Wrench only required)
- Integral Calibration Port
SYSTEM SPECIFICATIONS:
Sensor Type
Continuous diffusion/adsorption
Matched-pair catalytic bead detector
Plug-in field replaceable
Sensor Life
3 to 5 years typical
Measurement Range
0-100% LEL (lower explosive limit)
Accuracy/Repeatability
±3% 0-50% LEL; ±5% 50-100% LEL
Response/Clearing Time
T50 <10 seconds; T90 <30 seconds
Zero Drift
<5% per year
Outputs
Linear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical Classification
Explosion proof
CCSAUS
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C)
Class I, Zone 1, Group IIB+H2
ATEX
II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C)
Ingress Protection
NEMA 4X, IP66
Safety Approvals
CCSUS Performance to ANSI/ISA 60079-29-1
(12.13.01)-2013 and CSA 22.2 #152
ATEX
CE Marking
SIL2 Certified to IEC 61508
Warranty
Plug-in detector – 2 years
Transmitter – 2 Years
Environmental Specifications
Operating Temperature Range
-40°F to +167°F; -40°C to +75°C
Storage Temperature Range
-40°F to +167°F; -40°C to +75°C
Operating Humidity Range
0-99% RH non-condensing
MECHANICAL SPECIFICATIONS:
Dimensions
7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5”; 140mm center to center
Weight
2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
ELECTRICAL SPECIFICATIONS:
Power Input
11-30 VDC
Power Consumption
Normal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)
Inrush Current
1.0A @ 24V
RFI/EMI Protection
Complies with EN50270
Analog Output
Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA All Fault Diagnostics
2mA In-Calibration
4-20mA 0-100% full-scale
22mA Over-range condition
Serial RS-485 Output
RS-485 Modbus™ RTU
Baud Rate
9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators
4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan,
Set-up Options, and Fault Reporting
Faults Monitored
Operating Temperature, Loop, Input Voltage,
Bridge Voltage, Zero, Sensor,
Processor, Memory, Calibration
Cable Requirements
Power/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair shielded cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O Protection
Over-voltage, Miswiring, EMI/RFI Immunity
INTEGRATION OPTIONS
Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault)
Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered)
Wireless Integration Module (Detcon Model RXT-320 SmartWireless® Transceivers
Reviews