Det-Tronics FlexVu UD20 Universal Display
SKU: UD20
Manufacturer:
Det-Tronics
Bulk Orders
Competitive Pricing
Short Lead Times
Consolidated Shipping
Prompt Response
Request a Quote
FlexVu UD20 Universal Display (Spec Sheet: 90-1201 – Explosion-proof Model, 90-1205 – Intrinsically Safe Model) supports the GT3000 Series toxic gas detectors.
- Compliance to ANSI/ISA-60079-11 and ISA-92.0.01 Part 1 performance standard
- Division Approval Ratings: FM and CSA
- Zone Approval Ratings: FM, CSA, ATEX, and IECEx
- LCD display
- Non-intrusive automatic calibration
- Non-intrusive menu system
- Linear 4-20 mA output with HART
- Explosion-proof design
- IP66 rated
- 2 wire loop powered
- Certified Non-Interfering with GT3000 SIL model
FlexVu UD20 Model Matrix
MODEL | DESCRIPTION |
UD20 | Universal Display Unit |
TYPE | MATERIAL |
A | Aluminum |
S | Stainless Steel (316) |
TYPE | THREAD TYPE |
5M | 5 Port, Metric M25 |
5N | 5 Port, 3/4″ NPT |
TYPE | OUTPUTS |
26 | Pass-Through 4-20mA, HART |
TYPE | APPROVALS* |
B | INMETRO (BRAZIL) |
R | VNIIFTRI (RUSSIA) |
W | FM/CSA/ATEX/IECEx |
TYPE | CLASSIFICATION (Div/Zone) |
2 | Ex d (Flameproof) |
4 | Ex ia (intrinsically safe) |
FlexVu UD20 Universal Display – FM/CSA/ATEX/IECEx
Model | Part Number | Material | Threads | Pass-Through 4-20 HART |
Ex d | Ex ia | FM/CSA/ ATEX/IECEx |
UD20A5M26W2 | 009791-001 | AL | M25 | X | X | X | |
UD20A5N26W2 | 009791-002 | AL | 3/4 NPT | X | X | X | |
UD20S5M26W2 | 009791-003 | 316 SS | M25 | X | X | X | |
UD20S5N26W2 | 009791-004 | 316 SS | 3/4 NPT | X | X | X | |
UD20A5M26W4 | 009791-005* | AL | M25 | X | X | X | |
UD20A5N26W4 | 009791-006* | AL | 3/4 NPT | X | X | X | |
UD20S5M26W4 | 009791-007* | SS | M25 | X | X | X | |
UD20S5N26W4 | 009791-008* | SS | 3/4 NPT | X | X | X | |
Ship Weight: Aluminum = 4.2lb (1.9kg) Stainless Steel = 10.5lb (4.8kg) |
FlexVu UD20 Spares
Part Number | Description | Pass-Through 4-20 / HART |
Ship Weight |
009793-002 | UD20 Display Module | X | 1 lb (0.45 kg) |
FlexVu UD20 Accessories
Part Number | Description | Ship Weight |
009700-001 | Magnetic Tool | <1 lb (0.45 kg) |
010253-001 | Kit, 250Ω Terminating Resistor | <1 lb (0.45 kg) |
Stop Plugs and Reducers
Part Number | Description | Ship Weight |
101197-001* | Stop Plug, 3/4″ NPT, AL | <1 lb (<0.45 kg) |
101197-004* | Stop Plug, 3/4″ NPT, SS | <1 lb (<0.45 kg) |
101197-005 | Stop Plug, M25, AL, IP66 | <1 lb (<0.45 kg) |
101197-003 | Stop Plug, M25, SS, IP66 | <1 lb (<0.45 kg) |
010816-001* | Stop Plug, 20 Pack, 3/4″NPT, AL | 1 lb (0.45 kg) |
010817-001* | Stop Plug, 20 Pack, 3/4″NPT, SS | 2 lb (0.9 kg) |
010818-001 | Stop Plug, 20 Pack, M25, AL,IP66 | 1.5 lb (0.7 kg) |
010819-001 | Stop Plug, 20 Pack, M25, SS,IP66 | 3.25 lb (1.5 kg) |
102804-001 | Reducer, M25 to M20, AL | <1 lb (<0.45 kg) |
102804-003 | Reducer, M25 to M20, SS | <1 lb (<0.45 kg) |
*NEMA/TYPE 4 and IP66 rating requires addition of Teflon tape.
Be the first to review “Det-Tronics FlexVu UD20 Universal Display” Cancel reply
Related products
-
Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector
Design for commercial applications, OLC and OLCT10 detectors perfectly suit the protection of equipment and personnel in boiler or charging rooms where atmosphere may contain flammable gases. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Catalytic sensors 4-20mA output signal with OLCT 10 Dust and humidity resistant Fast and accurate response ATEX Approval for use in hazardous areas (zone 2 and 22) OLC10 and OLC10 TWIN OLC 10 TWIN allows connection of 2 sensors with a single channel without any additional junction box. Applications: Boiler rooms Charging rooms Wiring arrangement between OLC(T) 10 and MX 32 control unit Wiring arrangement between OLC 10 TWIN and MX 32 control unit Dimensions: Technical features: OLC 10 / OLC 10 TWIN OLCT 10 (Catalytic) Range Combustible gases - 0 to 100% LEL , Methane, Butane, Propane, LPG, Natural Gas or H2 Combustible Gases - 0 to 100% LEL Methane, Butane, Propane, GPL, Natural Gas or H2 Signal output Wheatstone Bridge Normal operation 4-20 mA (Fault < 0.5 mA or > 23.2 mA) Settings Managed by control unit Without opening the enclosure by means of 2 petentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Set to 23.2 mA if value > 100% LEL according to European standard EN 61779-4 Disable on request when managed by a suitable controller Consumption See on the manual of the controller 100 mA max Cabling OLC 10 : 3 Wire, shielded, core size 1,5 mm2 max. cable length 300 m 1 cable-gland M16 (outer \ 4 to 8 mm)OLC10 TWIN : shielded, core size 1,5 mm2, 3-wire to control unit, 4-wire between both sensors, max. cable length 300 m, 2 cable-glands M16 (outer \ 4 to 8 mm) 3-wire, shielded, core size 1,5 mm2, max. cable length 1km if connected with control unit (32 W max un loop) 1 cable gland M16 (outer \ 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP Rating IP65 IP65 Expected lifespan 36 to 48 months (sensor) 36 to 48 months (sensor) Operating temperature -10 to + 45 °C -10 to + 45 °C Operating humidity range -20 to +55°C -20 to +55°C Pressure Range 1 bar ± 20 % 1 bar ± 20 % Response Time Flammable gas : < 10s Flammable gas : < 10s Accuracy +/- 3% LEL +/- 3% LEL Certification EN 50270:2015 (type2) ATEX II 3 GD / Ex ec dc IIC T6 Gc Ex tc IIIC T85°C Dc EN 50270:2015 (type2) Product Data Sheet -
Teledyne Detcon Model 1000 Hydrogen Sulfide Analyzer
Model 1000-H2S Analyzer is designed to provide continuous, accurate, real-time measurement of hydrogen sulfide gas concentrations in a wide variety of process gas streams. With new technology and design, the Process Analyzer has a measurement range of 0-500 ppm. All H2 S analyzers in the Model 1000 Series employ Detcon’s 3-Electrode Electrochemical sensor element and feature a microprocessor-based signal-conditioning transmitter with local digital display, fault supervision, calibration mode indicator, 4-20mA, alarm relays and an RS-485 serial port. The lowest range for this unit is 0-10 ppm. The instrument package is rated for Non-Hazardous areas. APPLICATIONS: Gas Well Testing & Analysis Gas Well Production Sites Gas Treatment Plants Gas Transmission Custody Transfer Compliance FEATURES: Continuous Measurement with Superior Uptime Ranges from 0-500 ppm Readily Field Replaceable Sensors Simple Operation and Field Calibraton Standard Outputs: 4-20 mA, RS-485, 3 Relays Non-Hazardous Areas rated Sensor Type 3-Electrode Electrochemical Measurement Range Low Range 0-10/20/50/100/150/250/500 ppm Accuracy/Repeatability ±10% of reading or ±2.5% of range whichever is greater Response/Clearing Time T50 <30 seconds T90 <1 minute Max output to over-range gas: <10 seconds Operating Temperature Range -40°F to +122°F; -40°C to +50°C Operating Pressure Requirements Inlet: 10 ±2 psig Vent: Atmospheric ±1 psig Outputs Linear 4-20 mA DC RS-485 Modbus™ 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Power Input 117/220 VAC 18-36 VDC Electrical Classification Non-Hazardous Areas Warranty Sensor: 6 months Transmitter: 2 year Analyzer Weight 80 lbs. Shipping Weight 140 lbs Dimensions 29" x 29" x 8" Product Data Sheet -
Teledyne Detcon TP-624D Hydrogen Sulfide Sensor
Model TP-624D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the ranges of of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidity performance. Model TP-624D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D). Model TP-624D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, one-man remote calibration, self-adjusting zero and span, and LED indicators for 2 alarm relays and 1 fault relay and calibration status. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty. Order Guide Specify junction box options (below) PN 966-014520-100 - TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet PN 966-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-014520-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly 316SS condulet with Hart Note above part numbers are for 0-100 ppm range. For 0-20 ppm or 0-50 ppm range replace -100 with -020 or -050 respectively. APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S sensors dating back 20 years Compatible with PLCs, SCADA, DCS, via 0-20 mA, and /or RS-485, and/ or alarm relays Sensor status ad parameters accessible via RS-485 (Modbus) Menu programmable relays standard (two alarms plus fault) Simple menu driven calibration- less than 3 minutes LED display and LED indicators for FAULT and CAL ststus Plug-in field-replaceable transmitter Response similar to electrochemical sensor:T50 <30sec., T80 <60 sec. 10 year conditional sensor warranty Direct response constant temperature control Withstands exposure to high range concentrations of H2S and other acid gases Impervious to high moisture environments in both powered and non-powered mode Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of ) Response/Clearing Time T50 <30 seconds; T80 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Electrical Classification Explosion proof CSAus Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C) ) Class I, Zone 1, Group IIB+H2 cCSA Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB+H2 ATEX Ex d IIB+H2 T4 (Tamb = -40°C to +60°C) Safety Approvals cCSAus ATEX CE Marking SIL2 FMEDA Rating Ingress Protection IP66 Warranty Plug-in detector - 10 year conditional Transmitter - 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -35°C to +55°C; -13°F to +131°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC* * 12 VDC available by special order Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) RFI/EMI Protection Complies with EN 50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Relay Outputs Alarm 1, Alarm 2, and Fault 5A @ 250VAC 5A @ 30VDC Faults Monitored Heater, Loop, Input Voltage Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Oldham Simtronics CTX 300 Fixed Toxic Gas Detector
Presentation The CTX 300 can detect O2, CO2, toxic and refrigerant gases. TELEDYNE Gas & Flame Detection offers a detector version with a wide range of sensors (infrared, electrochemical, semiconductor) according to your application needs. It is also available with or without display. Simplicity Sensor replacement does not require any special menu access. Just replace the sensor without even powering down the transmitter! Reduced maintenance As the only consumable element, the CTX 300 sensor is easily replaceable. New sensors come pre-calibrated from the factory. So during the sensor ex-change, no calibration gas is required, nor adjustments to the detector, or remote central controller are required. FEATURES: Detection of toxic gases or oxygen Interchangeable and pre-calibrated sensor modules Local display (optional) Durable in harsh environments Up to 5 years of life for O2 sensor PART NUMBER GAS TYPE OF SENSOR RANGE (ppm) OPERATING TEMPERATURE WC3oO2F O2 Electrochimic 30.0 % -20 °C la +50 °C WC30O2G 30.0 % -40 °C to +50 °C WC3AO2G 30.0 % -20 °C to +50 °C WC3oO2S 100 % +5 °C to +40 °C WC3oCOA CO Electrochimic 100 -20 °C to +50 °C WC3oCOB 300 -20 °C to +50 °C WC3oCOC 1000 -20 °C to +50 °C WC3oCOD 1.00 % -20 °C to +50 °C WC3oCO2A CO2 Infrarosu 0.50% (5000ppm) -40 °C to +50 °C WC3oCO2B 5.00 % -40 °C to +50 °C WC3oCO2C 100 % -40 °C to +50 °C WC3oHSA H2S Electrochimic 30.0 -20 °C to +50 °C WC3oHSB 100 -20 °C to +50 °C WC3oHSC 1000 -20 °C to +50 °C WC3oNOA NO Electrochimic 100 -20 °C to +50 °C WC3oNOB 300 -20 °C to +50 °C WC3oNOC 1000 -20 °C to +50 °C WC3oN2A NO2 Electrochimic 10.0 -20 °C to +50 °C WC3oN2B 30.0 -20 °C to +50 °C WC3oSOA SO2 Electrochimic 10.0 -20 °C to +50 °C WC3oSOB 30.0 -20 °C to +50 °C WC3oSOC 30.0 -20 °C to +50 °C WC3oCL2 Cl2 Electrochimic 10.0 -20 °C to +50 °C WC3oH2A H2 Electrochimic 2000 -20 °C to +50 °C WC3oH2B 2 % -20 °C to +50 °C WC3oHLA HCl Electrochimic 30.0 -20 °C to +50 °C WC3oHLB 100 -20 °C to +50 °C WC3oHNA HCN Electrochimic 10.0 -20 °C to +50 °C WC3oHNB 30.0 -20 °C to +50 °C WC3oNH3 NH3 Electrochimic 100 -20 °C to +40 °C WC30NH3F 100 -40 °C to +40 °C WC3oNH1 1000 -20 °C to +40 °C WC30NH1F 1000 -40 °C to +40 °C WC30NH2 5000 -20 °C to +40 °C WC3oOET ETO/PO Electrochimic 30.0 -20 °C to +50 °C WC3oHFA HF Electrochimic 10.0 -10 °C to +30 °C WC3oO3A O3 Electrochimic 1.00 -20 °C to +50 °C WC3oPH3 PH3 Electrochimic 1.00 -20 °C to +50 °C WC3oCLO ClO2 Electrochimic 3.00 -20 °C to +50 °C WC3oCCL COCl2 Electrochimic 1.00 -20 °C to +40 °C CTX300-507 Methylene chloride Semiconductor 500 -20 °C to +55 °C CTX300-508 Methyl chloride Semiconductor 500 -20 °C to +60 °C CTX300-657 Toluene Semiconductor 500 -20 °C to +50 °C CTX300-660 Xylene Semiconductor 500 -20 °C to +55 °C CTX300-656 Ethanol Semiconductor 500 -20 °C to +50 °C CTX300-500 R12 Semiconductor 10000 -20 °C to +55 °C CTX300-501 R22 Semiconductor 2000 -20 °C to +55 °C CTX300-509 R123 Semiconductor 2000 -20 °C to +55 °C CTX300-502 R134a Semiconductor 2000 -20 °C to +55 °C CTX300-505 R11 Semiconductor 10000 -20 °C to +55 °C CTX300-506 R23 Semiconductor 10000 -20 °C to +55 °C CTX300-511 R143a Semiconductor 2000 -20 °C to +55 °C CTX300-521 R245fa Semiconductor 1000 -20 °C to +55 °C CTX300-512 R404a Semiconductor 2000 -20 °C to +55 °C CTX300-513 R507 Semiconductor 2000 -20 °C to +55 °C CTX300-514 R410a Semiconductor 1000 -20 °C to +55 °C CTX300-515 R32 Semiconductor 1000 -20 °C to +55 °C CTX300-525 HFO-1234ze Semiconductor 1000 -20 °C to +55 °C CTX300-662 HFO-1234yf Semiconductor 1000 -20 °C to +55 °C PART NUMBER ACCURACY (% at PA FULL SCALE) LIFE SPAN (IN MONTHS) T(50) (SECONDS) WC3oO2F +/- 1.5 % 28 10 WC30O2G +/- 1.5 % 60 10 WC3AO2G +/- 1.5 % 60 10 WC3oO2S +/- 1.5 % 36 < 20 WC3oCOA +/- 1.5 % 48 15 WC3oCOB +/- 1.5 % 48 15 WC3oCOC +/- 1.5 % 48 15 WC3oCOD +/- 1.5 % 48 < 20 WC3oCO2A +/- 2 % 60 <20 WC3oCO2B +/- 2 % 60 <20 WC3oCO2C +/- 2 % 60 <20 WC3oHSA +/- 1.5 % 36 15 WC3oHSB +/- 1.5 % 36 15 WC3oHSC +/- 1.5 % 36 15 WC3oNOA +/- 1.5 % 36 15 WC3oNOB +/- 1.5 % 36 15 WC3oNOC +/- 1.5 % 36 15 WC3oN2A +/- 1.5 % 24 20 WC3oN2B +/- 1.5 % 24 20 WC3oSOA +/- 1.5 % 36 15 WC3oSOB +/- 1.5 % 36 15 WC3oSOC +/- 1.5 % 36 15 WC3oCL2 +/- 1.5 % 24 50 WC3oH2A +/- 1.5 % 24 50 WC3oH2B +/- 1.5 % 24 50 WC3oHLA +/- 1.5 % 24 50 WC3oHLB +/- 1.5 % 24 50 WC3oHNA +/- 2 % 18 30 WC3oHNB +/- 2 % 18 30 WC3oNH3 +/- 3 % 24 <20 WC30NH3F +/- 3 % 24 <20 WC3oNH1 +/- 3 % 24 <20 WC30NH1F +/- 3 % 24 - WC30NH2 +/- 3 % 24 <20 WC3oOET +/- 3 % 36 50 WC3oHFA +/- 3 % 12 50 WC3oO3A +/- 3 % 18 40 WC3oPH3 +/- 3 % 12 40 WC3oCLO +/- 2 % 24 50 WC3oCCL +/- 1.5 % 18 50 CTX300-507 +/- 15 % relative to alarm threshold 36 40 CTX300-508 36 40 CTX300-657 36 20 CTX300-660 36 20 CTX300-656 36 20 CTX300-500 36 30 CTX300-501 36 30 CTX300-509 36 30 CTX300-502 36 30 CTX300-505 36 30 CTX300-506 36 30 CTX300-511 36 30 CTX300-521 36 30 CTX300-512 36 30 CTX300-513 36 30 CTX300-514 36 20 CTX300-515 36 20 CTX300-525 36 30 CTX300-662 36 30 Clear readability Highly sensitive, lighted display allows local reading Effective power-up indication by indicator lights Indication of maintenance or fault function by LED High-Level technology Pre-calibrated sensor avoiding the need to use unstable gases on site for calibration purposes High-performance semiconductor type detector (detection of freon gas, etc.) Available in an infrared version for CO2 Advanced design Highly resistant to environmental elements Avoids having to use protective covers Heavy-duty Use of polycarbonate and stainless steel mounting hardware Resistant to corrosive agents (H2S, HCl, sea spray,…) Durable housing Specifically adapted options Removable filters, interchangeable without opening the housing (which is dust-proof, condensation-proof and water resistant) Splash guard Gas collector cone Mounting brackets Pitot tubes, floats, heating protective device, etc. Remote calibration cup Enclosure: Polycarbonate housing Function: 4-20 mA output analog transmitter Display: Highly visible backlight LCD display unit (optional, gas dependent) Indicator lights: In operation: green color: Failure / maintenance: orange color Wiring: 2 wires shielded cable for CTX300 without display 3 wires shielded cable for CTX300 with display Cable entry: M16 cable gland (outer diameter 4 to 10 mm) Power supply: 15 to 32 V DC Maximum Power Consumption: CTX 300 without display unit: 60 mA, CTX 300 with display unit: 110 mA, CTX 300 without display semiconductor versions: 100mA Operating temperature: without display: -40°C to +50°C (-40°F to +122°F), sensor dependent with display: -20°C to +50°C (-4°F to +122°F), sensor dependent Sealing: IP 54, NEMA 3 & 3R Weight: 520 g (18.2 oz) Certification: EMC according to EN 50270:06 CSA CLASS 812 86, CLASS 4812 06 (SIGNAL APPLIANCES) all versions exept CO2 versions Impedance: 32 ohms max loop for CTX 300 with display unit and for semiconductors sensor versions, 64 ohms max loop for CTX 300 without display unit Product Data Sheet