Det-Tronics Ultra-High-Speed Flame Detection and Releasing System (Ultra FDRS)
Bulk Orders
As part of providing a listed flame detection and releasing system to the ultra-high-speed market segment, Detector Electronics Corporation offers several pre-engineered certified system options. Three standardized models are available to meet the needs of the small, medium, and large ultra-high-speed system user. These models utilize the proven EQ3900 Approved Fire and Gas Releasing Cabinet solution.
The Det-Tronics Ultra-High-Speed Flame Detection and Releasing System (Ultra FDRS) is an Eagle Quantum Premier® (EQP) based safety solution certified SIL 2 capable to function in challenging, high-hazard applications.
Each model includes an appropriately sized cabinet that houses an Eagle Quantum Premier Controller, High Speed Deluge Module(s), Enhanced Discreet Input Output Module(s), physical solenoid disconnect switches, and field wiring termination terminals.
![]() |
Ultra FDRS Model 2400
|
![]() |
Ultra FDRS Model 3600
|
![]() |
Ultra FDRS Model 4800
|
Related products
-
Oldham Simtronics DGi-TT7-E Electrochemical Toxic Gas Detector
The MultiTox DGi-TT7-E is an intelligent gas detector employing an array of sensor types. The device has been designed for ease of operation and maintenance. All DGi-TT7-E are constructed from a common housing and electronics with the detection properties being determined by the type of sensor (cartridge) used. A wide range of cells are available, these cells are intrisically safe protected, and may be replaced with the detector powered which minimises the system down time. The intelligent, microprocessor driven unit is fully configurable using a wireless hand-held terminal (TLU) or by using the hard wired HART option giving true flexibility to the installer and reduced service costs. Elements such as relay operation and alarm levels are all set via the TLU, a hazardous area approved hand-held unit. The unit may be interfaced directly with a wide range of panels, controllers and PLC’s etc. Its integral daylight readable alphanumeric display indicates local status and alarm level. Thanks to the hot swat field cabling technology, the sensor can be changed in a hazardous area without requiring area declassification. The device offers HART Protocol 7th edition output as an option which allows full configuration and diagnostics over nonproprietary interface. Features High visible display On board relays Display color is status dependent Technical data General: Technology Auto heating of electrochemical cell Output signal: Standard 4-20mA, max. load impedance 700 (Std. ) 2 x configurable Relays max 1 A / 30V Option HART(R) HART Protocol (7th edition) (pending) Option 0-22mA (User configurable) Option Lonworks (Syntel) Local display 4 digit LED display with automatic intensity adjustment Electrical: Power supply 24V DC, RANGE (18 - 28V DC) Power consumption 2W NOMINAL, 7.8W MAX. HEATING Connection 0.3 mm2 (22 AWG) - 1.5 mm2 (1 6 AWG) Shielded cable recommended Environmental: Storage -40°C to +70°C (-40°F to +158°F) Transmitter 0°C to +20°C (0°F to +68°F) Cartridge / Cell Operation See above table of gases Humidity 99% RH (non-condensing) Pressure Atmospheric pressure +/- 10% Ingress IP66 RFI /EMI Complies with EN50270 Housing: Material 316 L stainless steel Weight 4 Kg (8Lbs) Approvals: ATEX II 2 G Ex d ia I IC T6 Gb (-20°C to +60°C) Certificate number LCIE 13 ATEX 3024 X IECEx Ex d ia I IC T6 Gb - IECEx LCIE 13.001 X Accessories: TLU600 Infrared remote control unit AS056-250 Sun shade AS005 Calibration cup AS051 Calibration cup for breakable ampoules AS011 -2 Sample flow housing AS019 Splash guard CAL-K1 C-xxAE-1 A1 -00 Calibration kit (xx = gas to be specified) CAL-A00-xxAF-000-00 Box of 10 breakable gas ampoule (xx = 31 for1 00ppm NH3, 39 for 50ppm H2S) For use with AS051 cup AS047 Display protection Other products (stainless steel range): DG-TT7-S MultiTox, Solid-State (MOS) Gas Detector DF-TV7 MultiFlame, Flame Detector DG-TX7 MultiXplo, Flammable Gas Detector Product Data Sheet -
Oldham Simtronics OLCT 10N Fixed Digital Gas Detector
The OLCT 10N is a digital gas detector designed for detection of the most common gases in commercial and light industrial applications. Intended for use in combination with the MX 16, MX 32, MX43 or MX 256, the OLCT 10N provides a fast and accurate response. Up to 32 detectors can be connected on the same digital line or distributed on 8 lines. All transmitter information is received by the controller in less than 1 second. Non-intrusive operator interface requires only a simple magnetic wand and allows one man calibration without opening the enclosure, and calibration information, such as span reserve, is stored in the station. Certified IP65 and ATEX 3 GD for its explosive version, it is authorized for use in ATEX zones 2 and 22 and is waterproof and dustproof. Accessories Shock guard protector (2123717) OLCT 10N calibration tool kit (6331163) The OLCT 10N is the ideal solution for safe areas or zone 2 (22) ATEX locations. Configuration example Features: Detection of combustible gases, toxic gases or oxygen Digital technology Non-intrusive calibration Cost savings on wiring installation Applications: Cold rooms Car parks Technical features: Détecteur numérique OLCT 10N Range CH4, C3 H8, C4 H10, H2 O2 (> 2 years) O2 (5 years) CO H2S NO NO2 NH3 CO2 0-100 % LIE (-20°C à + 55°C) 0-30 % vol (-20°C à + 50°C) 0-30 % vol (-40°C à + 50°C) 0-300 ppm / 0-1000 ppm (-20°C à + 50°C) 0-30 ppm / 0-100 ppm (-20°C à + 50°C) 0-100 ppm / 0-300 ppm (-20°C à + 50°C) 0-10 ppm / 0-30 ppm (-20°C à + 50°C) 0-100 ppm / 0-1000 ppm (-20°C à + 40°C) 0-5000ppm / 0-5% vol / 0-100% vol (-40 à + 50°C) Output RS485 Modbus, proprietary protocol Power supply 12-30 Vcc Consumption Electrochemical sensor: Catalytic sensor : CO2 Infrared sensor: 2.5 mA in normal operation @ 24 Vdc 50 mA in normal operation @ 24 Vdc 20mA in normal operation @24Vdc Calibration Non-intrusive Cable inlet 2 PE M16, diamètre 4 à 8 mm Cable inlet With MX 32 (24 Vdc version): Up to 8 toxic or oxygen gas detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Up to 8 explosive gas detectors at 225 m with a 0.9 mm² (AWG 18) core size cable With MX 43: 2 x M16 cable entries, outer diameter 4 to 8 mm Up to 32 detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Dimensions (LxHxW) 118x110x60 mm Materials ABS, UV and shocks resistant Ingress protection IP65 Approvals for ATEX explosive versions II 3 GD Ex nA nC IIC T4 Gc for explosimetric versions Ex tc IIIC T135°C Dc -20°C<Ta<+55°C Electromagnetic compatibility according to EN50270 Ordering Information Part Number Description OLCT10N-001 Digital transmitter OLCT 10N, range 0-100% LEL CH4 OLCT10N-003 Digital transmitter OLCT 10N, range 0-100% LEL H2 OLCT10N-004 Digital transmitter OLCT 10N, range 0-100% LEL C4 H10 OLCT10N-005 Digital transmitter OLCT 10N, range 0-100% LEL C3 H8 OLCT10N-200 Digital transmitter OLCT 10N, range 0-30% vol O2 (2 year O2 sensor) OLCT10N-272 Digital transmitter OLCT 10N, range 0-30% vol O2 (5 year O2 sensor) OLCT10N-204 Digital transmitter OLCT 10N, range 0-300 ppm CO OLCT10N-205 Digital transmitter OLCT 10N, range 0-1000 ppm CO OLCT10N-213 Digital transmitter OLCT 10N, range 0-30 ppm H2S OLCT10N-214 Digital transmitter OLCT 10N, range 0-100 ppm H2S OLCT10N-216 Digital transmitter OLCT 10N, range 0-100 ppm NO OLCT10N-217 Digital transmitter OLCT 10N, range 0-300 ppm NO OLCT10N-219 Digital transmitter OLCT 10N, range 0-10 ppm NO2 OLCT10N-220 Digital transmitter OLCT 10N, range 0-30 ppm NO2 OLCT10N-231 Digital transmitter OLCT 10N, range 0-100 ppm NH3 OLCT10N-232 Digital transmitter OLCT 10N, range 0-1000 ppm NH3 OLCT10N-252 Digital transmitter OLCT 10N, range 0-5000 ppm CO2 OLCT10N-239 Digital transmitter OLCT 10N, range 0-5% vol CO2 OLCT10N-241 Digital transmitter OLCT 10N, range 0-100% vol CO2 Product Data Sheet -
Teledyne Detcon TP-700 Hydrogen Sulfide Sensor
Model TP-700 is a non-intrusive “Smart” sensor designed to detect and monitor H2S in air over the range of 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The TP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model TP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model TP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s solid state MOS H2S gas sensor has an infinite shelf life and is supported by a 10-year conditional warranty. Order Guide Specify junction box options (below) PN 967-015520-100 - TP-700 Sensor Assembly (no junction box) PN 967-011520-100 - TP-700 Sensor Assembly with Aluminum Junction Box PN 967-014520-100 - TP-700 Sensor Assembly with 316 SS Junction Box PN 9H7-011520-100 - TP-700 with HART in Aluminum Junction Box PN 9R7-011520-100 - TP-700 with RAM in Aluminum Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-Proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Plug-in field replaceable Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of) Response/Clearing Time T50 <30 seconds; T80 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus Complies with ISA 92.01 Part 1-1998; Performance Requirements for H2S ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in detector - 10 year conditional Transmitter - 2 Years ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -31°F to +131°F; -35°C to +55°C Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 1.0A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Heater, Loop, Input Voltage, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector
Design for commercial applications, OLC and OLCT10 detectors perfectly suit the protection of equipment and personnel in boiler or charging rooms where atmosphere may contain flammable gases. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Catalytic sensors 4-20mA output signal with OLCT 10 Dust and humidity resistant Fast and accurate response ATEX Approval for use in hazardous areas (zone 2 and 22) OLC10 and OLC10 TWIN OLC 10 TWIN allows connection of 2 sensors with a single channel without any additional junction box. Applications: Boiler rooms Charging rooms Wiring arrangement between OLC(T) 10 and MX 32 control unit Wiring arrangement between OLC 10 TWIN and MX 32 control unit Dimensions: Technical features: OLC 10 / OLC 10 TWIN OLCT 10 (Catalytic) Range Combustible gases - 0 to 100% LEL , Methane, Butane, Propane, LPG, Natural Gas or H2 Combustible Gases - 0 to 100% LEL Methane, Butane, Propane, GPL, Natural Gas or H2 Signal output Wheatstone Bridge Normal operation 4-20 mA (Fault < 0.5 mA or > 23.2 mA) Settings Managed by control unit Without opening the enclosure by means of 2 petentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Set to 23.2 mA if value > 100% LEL according to European standard EN 61779-4 Disable on request when managed by a suitable controller Consumption See on the manual of the controller 100 mA max Cabling OLC 10 : 3 Wire, shielded, core size 1,5 mm2 max. cable length 300 m 1 cable-gland M16 (outer \ 4 to 8 mm)OLC10 TWIN : shielded, core size 1,5 mm2, 3-wire to control unit, 4-wire between both sensors, max. cable length 300 m, 2 cable-glands M16 (outer \ 4 to 8 mm) 3-wire, shielded, core size 1,5 mm2, max. cable length 1km if connected with control unit (32 W max un loop) 1 cable gland M16 (outer \ 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP Rating IP65 IP65 Expected lifespan 36 to 48 months (sensor) 36 to 48 months (sensor) Operating temperature -10 to + 45 °C -10 to + 45 °C Operating humidity range -20 to +55°C -20 to +55°C Pressure Range 1 bar ± 20 % 1 bar ± 20 % Response Time Flammable gas : < 10s Flammable gas : < 10s Accuracy +/- 3% LEL +/- 3% LEL Certification EN 50270:2015 (type2) ATEX II 3 GD / Ex ec dc IIC T6 Gc Ex tc IIIC T85°C Dc EN 50270:2015 (type2) Product Data Sheet
Reviews