Controllers And Alarms
Showing all 3 results
-
Teledyne 8800 Controller – Multichannel Gas And Flame Monitoring System
The 8800 controller combines the reliability of our proven 7800 controller with advanced upgrades in one low cost package. The 8800 controller provides simultaneous display and alarm functions for up to 16 input variables. 8 or 16 channel display modes, and I/O modules arranged in groups of 8 channels, allow economical configuration of systems. This easy-to-configure, user friendly controller is ideal for centralizing display and alarm functions in critical multipoint monitoring applications. Features 8/16 channel display modes accept inputs from many sensor types and signal ranges. Input types include 4-20mA and Modbus Ethernet with Modbus TCP serves/client and web server for configuration and monitoring RS-485 serial ports allow simultaneous Modbus Master/Slave operation. Two standard ports and two optional isolated ports Three independent alarm levels per channel. “Relay Acknowledge” feature allows silencing of external audible devices during alarm conditions QVGA Color LCD displays monitored data as trends, bar graphs and engineering units. Readouts change colors to indicate alarms Five standard SPDT 5-amp alarm relays. HORN, FAULT and three programmable alarm relays Options cards such as 4-20mA inputs, 4-20mA outputs, discrete and programmable alarm relays Cal Mode offers push-button zero/span calibration for remote sensor applications Authorization Mode allows locking of critical settings Data Logger onto SD card allows recording of input values, and events for more than 10 years Power supply options include both 150 and 600 Watt Magnetic keypad standard for non-intrusive operation in potentially hazardous locations Enclosures include wall mount NEMA 4X - Non- Metallic, 316 SS, XP and Rack/Panel Mount 8800 Controller Input 12 bit 4-20mA into 150 ohms input impedance; includes +power supply terminals for each channel for routing power to two or three wire transmitters Serial Ports Two standard RS485 ports Two additional isolated ports optional Ethernet Port Modbus TCP Master/Slave port with web server (Gateway for Ethernet IP, Bacnet, and other protocols available) Alarm Relays 5 amp 30VDC or 250VAC resistive Form C Analog Outputs (Optional) 16 bit 4-20mA output. Max load 800 ohms with nominal 24VDC power supply Alarm Reset Two 10-60VDC Alarm Reset Input Terminals Digital Output 400mA @ VDC Display QVGA 320 x 240 pixel TFT graphic LCD with LED backlight Ambient Temperature Range -25 – +60 degrees C Power Supply 10 – 30VDC (24VDC nominal) 12 Watts max required 10-0172 option = 150 Watt 10-0307 option = 600 Watt Approvals CE Approved CSA C22.2 No 1010.1 and C22.2 No.152 for combustibles and ISA S82.02 CSA Class I Div 2 Grps A, B, C, D MAIN DATA SCREEN Displays all active channels on the same screen. Channel configurations include 16, active channels. Cells indicate alarm status by color. BAR GRAPH SCREEN Displays 16 channels at a time. Bar graphs change colors to indicate alarm status. 24 HOUR TREND SCREEN Displays 1 channel at a time as most recent 24 hour trend. Top data fields include current reading, max – min – average readings over the 24 hours, range, channel ID and engineering units. COMBINATION SCREEN Displays 1 channel at a time as most recent 30-minute trend, bar graph and large engineering units. Top data fields include current reading, max - min -average readings for trouble shooting, range, channel ID, and engineering units. Readings change color and flash on alarms. Flashing color becomes steady after acknowledge. ZONE SCREEN Displays all eight possible active zones. Alarm cells change colors and name field flashes indicating alarms. Allows user direct access to screen that shows which channels belong to each zone. Product Data Sheet -
Teledyne 8864 Controller – Multichannel Gas And Flame Monitoring System
The 8864 controller provides simultaneous display and alarm functions for up to 64 input variables. 16, 32, 48, and 64 channel display modes, and I/O modules arranged in groups of 16 channels, allow economical configuration of systems. This easy-to-configure, user friendly controller is ideal for centralizing display and alarm functions in critical multipoint monitoring applications. The similarity in function and user interface between the 8864 and the 16 channel 8800 makes usage of this family of controllers straightforward where both are used. Features 16, 32, 48, & 64 channel display modes accept inputs from many sensor types and signal ranges. Input types include 4-20mA, Modbus, and wireless options. Ethernet with Modbus TCP serves/client and web server for configuration and monitoring RS-485 serial ports allow simultaneous Modbus Master/ Slave operation. Two standard ports and two optional isolated ports Three independent alarm levels per channel. “Relay Acknowledge” feature allows silencing of external audible devices during alarm conditions QVGA Color LCD displays monitored data as trends, bar graphs and engineering units. Readouts change colors to indicate alarms CSA certified for Division 2 potentially hazardous areas Five standard SPDT 5-amp alarm relays. HORN, FAULT and three programmable alarm relays Options cards such as 4-20mA inputs, 4-20mA outputs, discrete and programmable alarm relays and bridge sensor inputs Cal Mode offers push-button zero/span calibration for remote sensor applications Authorization Mode allows locking of critical settings Data Logger onto SD card allows recording of minimum, maximum, and average values for one year Power supply options include both 150 and 600 Watt Magnetic keypad standard for non-intrusive operation in potentially hazardous locations Enclosures include wall mount NEMA 4X - Non- Metallic, 316 SS, XP and Rack/Panel Mount 8864 Controller Input 12 bit 4-20mA into 150 ohms input impedance; includes +power supply terminals for each channel for routing power to two or three wire transmitters Serial Ports Modbus Master and Slave RS485 ports equipped with Tx / Rx LEDs Ethernet Port Modbus TCP Master/Slave port with web server (Gateway for Ethernet IP, Bacnet, and other protocols available) Alarm Relays 5 amp 30VDC or 250VAC resistive Form C Analog Outputs (Optional) 16 bit 4-20mA output. Max load 800 ohms with nominal 24VDC power supply Bridge Inputs (Optional) 12 bit, 16 channel bridge input Display QVGA 320 x 240 pixel TFT graphic LCD with LED backlight5 LEDs show standard relay alarm status Ambient Temperature Range -25 – +60 degrees C Power Supply 10 – 30VDC (24VDC nominal) 12 Watts max required 10-0172 option = 150 Watt 10-0307 option = 600 Watt Approvals CSA C22.2 No 1010.1 and C22.2 No.152 for combustibles and ISA S82.02 UL 1604 / C22.2 No 213 (NEMA 4X = Division 2 Groups A,B,C,D,) EN55011 and EN61000 (CE Mark) MAIN DATA SCREEN Displays all active channels on the same screen. Channel configurations include 16, active channels. Cells indicate alarm status by color. BAR GRAPH SCREEN Displays 16 channels at a time. Bar graphs change colors to indicate alarm status. 24 HOUR TREND SCREEN Displays 1 channel at a time as most recent 24 hour trend. Top data fields include current reading, max – min – average readings over the 24 hours, range, channel ID and engineering units. COMBINATION SCREEN Displays 1 channel at a time as most recent 30-minute trend, bar graph and large engineering units. Top data fields include current reading, max - min -average readings for trouble shooting, range, channel ID, and engineering units. Readings change color and flash on alarms. Flashing color becomes steady after acknowledge. ZONE SCREEN Displays all eight possible active zones. Alarm cells change colors and name field flashes indicating alarms. Allows user direct access to screen that shows which channels belong to each zone. Product Data Sheet -
Teledyne Detcon Model X40 Integrated Alarm And Control System
Model X40 is a low power alarm and control system designed to monitor multiple gas detection sensors and/or a wide range of other field devices. The versatile control system is designed to receive and supervise inputs using either 4-20mA DC or Serial RS-485 Modbus™ and is available in two packages: Model X40-8 and Model X40-32. Both packages function as a Modbus™ Master and can be customized and expanded based on individual application needs using the stackable din-rail mounted I/O modules. All I/O modules are individually addressable and operate on 11.5-30VDC. The X40-8 provides power for up to eight field devices and can house up to six 4-channel I/O modules. The Model X40-32 provides power for up to 32 field devices and can house up to 12 4-channel I/O modules. The I/O modules available for use with the Model X40 include a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). The modules can be mounted within the main system enclosure or installed remotely to simplify field wiring. The Model X40 is completely field programmable using a small handheld magnet and offers advanced technology with intuitive, embedded intelligence. The control system displays real-time readings and field device status on a backlit LCD screen. During normal operation, the screen displays the alarm status and current reading (i.e., channel number, gas type, and gas concentration) for up to eight field devices simultaneously. The display is sequential and during normal operation it auto cycles through each of the active channel screens. Among the system’s unique features is a wireless option that can be used with RXT-320 SmartWireless® transceivers. Enclosure options include: NEMA 4X, NEMA 1 panel mount, and NEMA 7. Features 8 to 32 channel capacity Backlit LCD screen display Analog or RS-485 input options Easy intuitive field configuration Wire or distributed I/O Extensive event data logging SmartWireless® capable Applications Oil and gas drilling rigs Oil and gas production sites Offshore production platforms Wastewater treatment plants Food and beverage processing Pulp and paper mills Refining and petrochemical SYSTEM SPECIFICATIONS System Capacity Model X40-32-N1P: Up to 32 field devices Model X40-8-N4X: Up to 8 field devices Model X40-32-N4X: Up to 32 field devices Model X40-32-N7: Up to 32 field devices (analog or serial) Indicators 1 1/8” by 5 3/4” backlit LCD Alarm status LEDs Display Accuracy ±1% of full scale value Input Options Analog 4-20 mA DC RS-485 Modbus™ *(Only compatible with other Detcon products) Relay Contacts Output Options 4-20 mA DC RS-485 Modbus™ Relay Contacts Safety Approvals CE Marking (Models X40-N4X & X40-SS) Warranty One Year ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -4ºF to + 158ºF, -20ºC to + 70ºC Storage Temperature Range -40ºF to + 185ºF, -40ºC to + 85ºC Operating Humidity Range 0-99% RH non-condensing MECHANICAL SPECIFICATIONS Dimensions Model X40-32-N1P: 10.5”W x 8”H x 12”D Model X40-8-N4X: 12”W x 14”H x 7.75”D Model X40-32-N4X: 16”W x 17.85”H x 9.5”D Model X40-32-N7: 11”W x 9.15”H x 2.75”D Weight Model X40-32-N1P: 10 lbs Model X40-8-N4X: 10 lbs Model X40-32-N4X: 20 lbs Model X40-32-N7: 10 lbs ELECTRICAL OPTIONS Power Input 115-230 VAC* or 11.5-30 VDC * Option for Model X40-32-N7 Power Consumption <0.25 Watt (I/O module power consumption not included) (Field device power consumption not included) Electrical Classification Model X40-32-N1P: NEMA 1 Panel Mount Model X40-8-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N7: NEMA 7 Class I; Division 1, Group C, D Order Guide PN 95P-X32000-000 Model X40-32-N1P, General purpose panel mount hardware assembly 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 954-X08000-000 Model X40-8-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 8 active channels). PN 954-X32000-000 Model X40-32-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 957-X32000-000 Model X40-32-N7, Div 1 weatherproof enclosure 24 VDC power* for use in distributed I/O installations only (up to 32 active channels). Product Data Sheet