Teledyne Detcon 897-860800-316 Mini 316SS junction box bottom
What is the Teledyne Detcon 897-860800-316?The Teledyne Detcon 897-860800-316 is: Mini 316SS junction box bottom. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the 316 stainless steel variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-860800-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-075M20-316 3/4″ NPT male to M20 female 316 SS adapter
What is the Teledyne Detcon 898-075M20-316?The Teledyne Detcon 898-075M20-316 is: 3/4" NPT male to M20 female 316 SS adapter. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the 316 stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-075M20-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPA0AD-050 1/2″ Alum stopping plug
What is the Teledyne Detcon 898-SPA0AD-050?The Teledyne Detcon 898-SPA0AD-050 is: 1/2" Alum stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPA0AD-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPA0AD-075 3/4″ Alum stopping plug
What is the Teledyne Detcon 898-SPA0AD-075?The Teledyne Detcon 898-SPA0AD-075 is: 3/4" Alum stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPA0AD-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPA0AD-M20 M20 Alum stopping plug
What is the Teledyne Detcon 898-SPA0AD-M20?The Teledyne Detcon 898-SPA0AD-M20 is: M20 Alum stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPA0AD-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPA0SD-050 1/2″ Stainless Steel stopping plug
What is the Teledyne Detcon 898-SPA0SD-050?The Teledyne Detcon 898-SPA0SD-050 is: 1/2" Stainless Steel stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPA0SD-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPA0SD-316 3/4″ Stainless Steel stopping plug
What is the Teledyne Detcon 898-SPA0SD-316?The Teledyne Detcon 898-SPA0SD-316 is: 3/4" Stainless Steel stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPA0SD-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPA0SD-M20 M20 Stainless Steel stopping plug
What is the Teledyne Detcon 898-SPA0SD-M20?The Teledyne Detcon 898-SPA0SD-M20 is: M20 Stainless Steel stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPA0SD-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPANPD-050 1/2″ Nickel Plated stopping plug
What is the Teledyne Detcon 898-SPANPD-050?The Teledyne Detcon 898-SPANPD-050 is: 1/2" Nickel Plated stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPANPD-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPANPD-075 3/4″ Nickel Plated stopping plug
What is the Teledyne Detcon 898-SPANPD-075?The Teledyne Detcon 898-SPANPD-075 is: 3/4" Nickel Plated stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPANPD-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-SPANPD-M20 M20 Nickel Plated stopping plug
What is the Teledyne Detcon 898-SPANPD-M20?The Teledyne Detcon 898-SPANPD-M20 is: M20 Nickel Plated stopping plug. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-SPANPD-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 898-XANMNM-000 Adapter for Mounting High gain antenna to box.
What is the Teledyne Detcon 898-XANMNM-000?The Teledyne Detcon 898-XANMNM-000 is: Adapter for Mounting High gain antenna to box. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.About the Teledyne Detcon Mounting & Sensor Protection lineSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 898-XANMNM-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 899-075050-0NP 3/4″ NPT male to 1/2″ NPT female Nickel Plated Adapter
What is the Teledyne Detcon 899-075050-0NP?The Teledyne Detcon 899-075050-0NP is: 3/4" NPT male to 1/2" NPT female Nickel Plated Adapter. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 899-075050-0NP on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 899-075050-316 3/4″ NPT male to 1/2″ female NPT 316SS Adapter
What is the Teledyne Detcon 899-075050-316?The Teledyne Detcon 899-075050-316 is: 3/4" NPT male to 1/2" female NPT 316SS Adapter. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the 316 stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 899-075050-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 899-075M20-0NP 3/4″ NPT male to M20 female Nickel Plated Adapter
What is the Teledyne Detcon 899-075M20-0NP?The Teledyne Detcon 899-075M20-0NP is: 3/4" NPT male to M20 female Nickel Plated Adapter. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 899-075M20-0NP on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 925-0154D0-100 Plug-in transmitter control module (Model TP-524D)
What is the Teledyne Detcon 925-0154D0-100?The Teledyne Detcon 925-0154D0-100 is: Plug-in transmitter control module (Model TP-524D). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 925-0154D0-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 925-015HD0-100 Plug-in transmitter module (Model TP-524D) with Hart
What is the Teledyne Detcon 925-015HD0-100?The Teledyne Detcon 925-015HD0-100 is: Plug-in transmitter module (Model TP-524D) with Hart. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 925-015HD0-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 925-5254D0-100 Plug-in transmitter module (Model FP-524D)
What is the Teledyne Detcon 925-5254D0-100?The Teledyne Detcon 925-5254D0-100 is: Plug-in transmitter module (Model FP-524D). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 925-5254D0-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 925-525HD0-100 Plug-in transmitter module (Model FP-524D) with Hart
What is the Teledyne Detcon 925-525HD0-100?The Teledyne Detcon 925-525HD0-100 is: Plug-in transmitter module (Model FP-524D) with Hart. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 925-525HD0-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 926-0155D0-100 Plug-in transmitter control module (Model TP-624D)
What is the Teledyne Detcon 926-0155D0-100?The Teledyne Detcon 926-0155D0-100 is: Plug-in transmitter control module (Model TP-624D). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 926-0155D0-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 926-5255D0-100 Plug-in transmitter module (Model FP-624D)
What is the Teledyne Detcon 926-5255D0-100?The Teledyne Detcon 926-5255D0-100 is: Plug-in transmitter module (Model FP-624D). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 926-5255D0-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 927-70000A-000 Detcon Model 700 Alarm Module (Remote Alarm Module, RAM 700) with Form-C relays for the Model
What is the Teledyne Detcon 927-70000A-000?The Teledyne Detcon 927-70000A-000 is: Detcon Model 700 Alarm Module (Remote Alarm Module, RAM 700) with Form-C relays for the Model 700 sensor series; housed in aluminum or 316SS condulet with glass lens cover. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the 316 stainless steel variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 927-70000A-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 927-70000H-000 Hart/RAM Module
What is the Teledyne Detcon 927-70000H-000?The Teledyne Detcon 927-70000H-000 is: Hart/RAM Module. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 927-70000H-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-000112-010 NH3, Ammonia 10 ppm Air
What is the Teledyne Detcon 942-000112-010?The Teledyne Detcon 942-000112-010 is: NH3, Ammonia 10 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-000112-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-000112-025 NH3, Ammonia 25 ppm Air
What is the Teledyne Detcon 942-000112-025?The Teledyne Detcon 942-000112-025 is: NH3, Ammonia 25 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-000112-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-000112-050 NH3, Ammonia 50 ppm Air
What is the Teledyne Detcon 942-000112-050?The Teledyne Detcon 942-000112-050 is: NH3, Ammonia 50 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-000112-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-000112-100 NH3, Ammonia 100 ppm Air
What is the Teledyne Detcon 942-000112-100?The Teledyne Detcon 942-000112-100 is: NH3, Ammonia 100 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-000112-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-000112-300 NH3, Ammonia 300 ppm Air
What is the Teledyne Detcon 942-000112-300?The Teledyne Detcon 942-000112-300 is: NH3, Ammonia 300 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-000112-300 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-000132-050 NH3, Ammonia 50 ppm Air
What is the Teledyne Detcon 942-000132-050?The Teledyne Detcon 942-000132-050 is: NH3, Ammonia 50 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-000132-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-001123-000 Zero Air, 103 liters
What is the Teledyne Detcon 942-001123-000?The Teledyne Detcon 942-001123-000 is: Zero Air, 103 liters. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-001123-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-005 H2S, Hydrogen Sulfide 5 ppm Air
What is the Teledyne Detcon 942-010112-005?The Teledyne Detcon 942-010112-005 is: H2S, Hydrogen Sulfide 5 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-010 H2S, Hydrogen Sulfide 10 ppm Air
What is the Teledyne Detcon 942-010112-010?The Teledyne Detcon 942-010112-010 is: H2S, Hydrogen Sulfide 10 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-020 H2S, Hydrogen Sulfide 20 ppm Air
What is the Teledyne Detcon 942-010112-020?The Teledyne Detcon 942-010112-020 is: H2S, Hydrogen Sulfide 20 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-025 H2S, Hydrogen Sulfide 25 ppm Air
What is the Teledyne Detcon 942-010112-025?The Teledyne Detcon 942-010112-025 is: H2S, Hydrogen Sulfide 25 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-040 H2S, Hydrogen Sulfide 40 ppm Air
What is the Teledyne Detcon 942-010112-040?The Teledyne Detcon 942-010112-040 is: H2S, Hydrogen Sulfide 40 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-040 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-050 H2S, Hydrogen Sulfide 50 ppm Air
What is the Teledyne Detcon 942-010112-050?The Teledyne Detcon 942-010112-050 is: H2S, Hydrogen Sulfide 50 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-0500 H2S, Hydrogen Sulfide 50 ppm Air
What is the Teledyne Detcon 942-010112-0500?The Teledyne Detcon 942-010112-0500 is: H2S, Hydrogen Sulfide 50 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-0500 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010112-100 H2S, Hydrogen Sulfide 100 ppm Air
What is the Teledyne Detcon 942-010112-100?The Teledyne Detcon 942-010112-100 is: H2S, Hydrogen Sulfide 100 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010112-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010132-025 H2S, Hydrogen Sulfide 25 ppm Air
What is the Teledyne Detcon 942-010132-025?The Teledyne Detcon 942-010132-025 is: H2S, Hydrogen Sulfide 25 ppm Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010132-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010212-005 H2S, Hydrogen Sulfide 5 ppm Nitrogen
What is the Teledyne Detcon 942-010212-005?The Teledyne Detcon 942-010212-005 is: H2S, Hydrogen Sulfide 5 ppm Nitrogen. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010212-005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-010212-010 H2S, Hydrogen Sulfide 10 ppm Nitrogen
What is the Teledyne Detcon 942-010212-010?The Teledyne Detcon 942-010212-010 is: H2S, Hydrogen Sulfide 10 ppm Nitrogen. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-010212-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-040212-010 HCN, Hydrogen Cyanide 10 ppm Nitrogen
What is the Teledyne Detcon 942-040212-010?The Teledyne Detcon 942-040212-010 is: HCN, Hydrogen Cyanide 10 ppm Nitrogen. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-040212-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-040212-025 HCN, Hydrogen Cyanide 25 ppm Nitrogen
What is the Teledyne Detcon 942-040212-025?The Teledyne Detcon 942-040212-025 is: HCN, Hydrogen Cyanide 25 ppm Nitrogen. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-040212-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-040232-010 HCN, Hydrogen Cyanide 10 ppm Nitrogen
What is the Teledyne Detcon 942-040232-010?The Teledyne Detcon 942-040232-010 is: HCN, Hydrogen Cyanide 10 ppm Nitrogen. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-040232-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 942-12G124-050 C2H2, Acetylene 1.25% (50% Air
What is the Teledyne Detcon 942-12G124-050?The Teledyne Detcon 942-12G124-050 is: C2H2, Acetylene 1.25% (50% Air. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-12G124-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification.