Gas and Flame Detection Systems
Showing 721–765 of 884 results
-

Teledyne Detcon 942-940212-025 NO, Nitric Oxide 25 ppm Nitrogen
What is the Teledyne Detcon 942-940212-025?The Teledyne Detcon 942-940212-025 is: NO, Nitric Oxide 25 ppm Nitrogen. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 942-940212-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-000000-000 Calibration Sleeve/Wind Guard for use with splash guard
What is the Teledyne Detcon 943-000000-000?The Teledyne Detcon 943-000000-000 is: Calibration Sleeve/Wind Guard for use with splash guard. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-000000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 943-000006-038 Calibration adapter, solid state H2S TP-424/524/624
What is the Teledyne Detcon 943-000006-038?The Teledyne Detcon 943-000006-038 is: Calibration adapter, solid state H2S TP-424/524/624. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-000006-038 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-000006-132 Calibration adapter FP/IR/DM/O2/PI/TP-700
What is the Teledyne Detcon 943-000006-132?The Teledyne Detcon 943-000006-132 is: Calibration adapter FP/IR/DM/O2/PI/TP-700. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-000006-132 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-001747-SS5 Stainless steel flow through adapter, Fits 700’s, FP 4,5,600’s, DM series 5,600’s, DM-100’s
What is the Teledyne Detcon 943-001747-SS5?The Teledyne Detcon 943-001747-SS5 is: Stainless steel flow through adapter, Fits 700's, FP 4,5,600's, DM series 5,600's, DM-100's. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Model 700 Series lineSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsEnclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-001747-SS5 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 943-001747-T05 Calibration adapter, teflon for highly reactive gases (HCl, CL2, HCN, NH3)
What is the Teledyne Detcon 943-001747-T05?The Teledyne Detcon 943-001747-T05 is: Calibration adapter, teflon for highly reactive gases (HCl, CL2, HCN, NH3). Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-001747-T05 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-001767-5RG GMI stainless steel 0.5 LPM male thread fixed flow regulator for reactive gases such as NH3
What is the Teledyne Detcon 943-001767-5RG?The Teledyne Detcon 943-001767-5RG is: GMI stainless steel 0.5 LPM male thread fixed flow regulator for reactive gases such as NH3, Cl2, and HCl; fits 2AL (34 L), 8AL (58 L), and 6D (105 L) calibration gas cylinders. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately. The Calibration Gases & Kits group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-001767-5RG on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-001767-XRG GMI stainless steel 1.0 LPM fixed flow regulator with gauge; fits 2AL (34 L), 8AL (58 L)
What is the Teledyne Detcon 943-001767-XRG?The Teledyne Detcon 943-001767-XRG is: GMI stainless steel 1.0 LPM fixed flow regulator with gauge; fits 2AL (34 L), 8AL (58 L), and 6D (105 L) calibration gas cylinders; for reactive remote sensor applications. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately. The Calibration Gases & Kits group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-001767-XRG on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-001781-5AM Regulator for NH3, fixed flow rate 500 milliliters
What is the Teledyne Detcon 943-001781-5AM?The Teledyne Detcon 943-001781-5AM is: Regulator for NH3, fixed flow rate 500 milliliters. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-001781-5AM on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-002273-000 Harsh location dust guard (fits 1.5 x 18 thread) Fits 700’s, FP 4,5,600’s, DM series 5,600’s
What is the Teledyne Detcon 943-002273-000?The Teledyne Detcon 943-002273-000 is: Harsh location dust guard (fits 1.5 x 18 thread) Fits 700's, FP 4,5,600's, DM series 5,600's,. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-002273-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 943-002274-000 Hazardous location dust guard 7/8 Fits TP-4,5,600 series sensors
What is the Teledyne Detcon 943-002274-000?The Teledyne Detcon 943-002274-000 is: Hazardous location dust guard 7/8 Fits TP-4,5,600 series sensors. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-002274-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 943-002401-000 Calibration adapter, Detcon Model 200
What is the Teledyne Detcon 943-002401-000?The Teledyne Detcon 943-002401-000 is: Calibration adapter, Detcon Model 200. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-002401-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-003436-000 Harsh location water guard, fits all series with standard splsh guard
What is the Teledyne Detcon 943-003436-000?The Teledyne Detcon 943-003436-000 is: Harsh location water guard, fits all series with standard splsh guard. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-003436-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 943-003832-000 Mini Condulet Pipe Mount Plate
What is the Teledyne Detcon 943-003832-000?The Teledyne Detcon 943-003832-000 is: Mini Condulet Pipe Mount Plate. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-003832-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-004221-000 Sensor Mounting Plate for 2″ pipe
What is the Teledyne Detcon 943-004221-000?The Teledyne Detcon 943-004221-000 is: Sensor Mounting Plate for 2" pipe. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-004221-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 943-004223-000 Sensor Mounting Plate with Sunshade for 2-3″ pipe
What is the Teledyne Detcon 943-004223-000?The Teledyne Detcon 943-004223-000 is: Sensor Mounting Plate with Sunshade for 2-3" pipe. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.About the Teledyne Detcon Mounting & Sensor Protection lineSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-004223-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-004389-100 2″ Pipe mount w/Sunshade for CXT sensor Rechargeable/D Cell Battteries
What is the Teledyne Detcon 943-004389-100?The Teledyne Detcon 943-004389-100 is: 2" Pipe mount w/Sunshade for CXT sensor Rechargeable/D Cell Battteries. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-004389-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-004413-000 Sensor mountbrackets for Large Tripod legs
What is the Teledyne Detcon 943-004413-000?The Teledyne Detcon 943-004413-000 is: Sensor mountbrackets for Large Tripod legs. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-004413-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-020000-000 Span Gas Kit: includes calibration adapter, span gas humidifier, 200 cc/min fixed flow
What is the Teledyne Detcon 943-020000-000?The Teledyne Detcon 943-020000-000 is: Span Gas Kit: includes calibration adapter, span gas humidifier, 200 cc/min fixed flow regulator, and carrying case (gas not included). Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-020000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-050000-000 Span gas kit with 500 cc/min fixed flow regulator, tubing, span gas humidifier, calibration
What is the Teledyne Detcon 943-050000-000?The Teledyne Detcon 943-050000-000 is: Span gas kit with 500 cc/min fixed flow regulator, tubing, span gas humidifier, calibration sleeve/wind guard, and carrying case (gas not included); sibling variants 943-050000-132 and 943-050000-HRG appear in the official Model 100 manual spare parts table. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-050000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-050000-HRG Highly Reactive Gas Span Gas Kit, used for NH3, Cl2, HCl, HBr, and similar gases; stainless
What is the Teledyne Detcon 943-050000-HRG?The Teledyne Detcon 943-050000-HRG is: Highly Reactive Gas Span Gas Kit, used for NH3, Cl2, HCl, HBr, and similar gases; stainless steel regulator with Teflon tubing and carry bag. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately. The Calibration Gases & Kits group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-050000-HRG on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-05AM00-000 500 cc/min fixed flow regulator for span gas bottle
What is the Teledyne Detcon 943-05AM00-000?The Teledyne Detcon 943-05AM00-000 is: 500 cc/min fixed flow regulator for span gas bottle. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-05AM00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-090005-502 Regulator, fixed flow rate 200 milliliters
What is the Teledyne Detcon 943-090005-502?The Teledyne Detcon 943-090005-502 is: Regulator, fixed flow rate 200 milliliters. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-090005-502 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-090005-510 Fixed flow regulator, 500 mL/min (0.5 LPM), for calibration gas cylinders
What is the Teledyne Detcon 943-090005-510?The Teledyne Detcon 943-090005-510 is: Fixed flow regulator, 500 mL/min (0.5 LPM), for calibration gas cylinders. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-090005-510 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-090005-520 GMI 1.0 LPM regulator with gauge; fits 2AL (34 L), 8AL (58 L), and 6D (105 L) cylinders
What is the Teledyne Detcon 943-090005-520?The Teledyne Detcon 943-090005-520 is: GMI 1.0 LPM regulator with gauge; fits 2AL (34 L), 8AL (58 L), and 6D (105 L) cylinders; for non-reactive remote sensor applications. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-090005-520 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-090092-032 Canvas carry bag with foam insert for 2 gas cylinders
What is the Teledyne Detcon 943-090092-032?The Teledyne Detcon 943-090092-032 is: Canvas carry bag with foam insert for 2 gas cylinders. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-090092-032 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-100000-000 Span gas kit complete with 1 liter fixed flow regulator, 6 foot length of tubing, humidifier
What is the Teledyne Detcon 943-100000-000?The Teledyne Detcon 943-100000-000 is: Span gas kit complete with 1 liter fixed flow regulator, 6 foot length of tubing, humidifier, calibration sleeve/wind guard, and carrying case (gas not included). Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-100000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 943-121747-SS5 Stainless steel flow through adapter, Fits 700’s, FP 4,5,600’s, DM series 5,600’s, DM-100’s
What is the Teledyne Detcon 943-121747-SS5?The Teledyne Detcon 943-121747-SS5 is: Stainless steel flow through adapter, Fits 700's, FP 4,5,600's, DM series 5,600's, DM-100's. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications. The Model 100 Series group in the Detcon price book lists 11 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-121747-SS5 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 943-200000-000 Activation Carbon Scrubber
What is the Teledyne Detcon 943-200000-000?The Teledyne Detcon 943-200000-000 is: Activation Carbon Scrubber. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 943-200000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 949-005142-200 Drop-in X40 Control Assembly with bezel
What is the Teledyne Detcon 949-005142-200?The Teledyne Detcon 949-005142-200 is: Drop-in X40 Control Assembly with bezel. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 949-005142-200 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 949-0M1000-700 700 Series Inner Assembly without Pump
What is the Teledyne Detcon 949-0M1000-700?The Teledyne Detcon 949-0M1000-700 is: 700 Series Inner Assembly without Pump. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 949-0M1000-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 949-PM1000-700 700 Series Inner Assembly with Pump
What is the Teledyne Detcon 949-PM1000-700?The Teledyne Detcon 949-PM1000-700 is: 700 Series Inner Assembly with Pump. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 949-PM1000-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 952-T14000-101 Model 1000 Analyzer, Single Channel, 1% CO2 by Vol. with Air Flow Fault
What is the Teledyne Detcon 952-T14000-101?The Teledyne Detcon 952-T14000-101 is: Model 1000 Analyzer, Single Channel, 1% CO2 by Vol. with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T14000-101 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T14000-301 Model 1000 Analyzer, Single Channel, 3% CO2 by Vol. with Air Flow Fault
What is the Teledyne Detcon 952-T14000-301?The Teledyne Detcon 952-T14000-301 is: Model 1000 Analyzer, Single Channel, 3% CO2 by Vol. with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T14000-301 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T14000-501 Model 1000 Analyzer, Single Channel, 5% CO2 by Vol. with Air Flow Fault
What is the Teledyne Detcon 952-T14000-501?The Teledyne Detcon 952-T14000-501 is: Model 1000 Analyzer, Single Channel, 5% CO2 by Vol. with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T14000-501 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T14200-601 Model 1000 Analyzer, Single Channel, 10% CO2 by Vol. with Air Flow Fault
What is the Teledyne Detcon 952-T14200-601?The Teledyne Detcon 952-T14200-601 is: Model 1000 Analyzer, Single Channel, 10% CO2 by Vol. with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T14200-601 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T14200-701 Model 1000 Analyzer, Single Channel, 20% CO2 by Vol. with Air Flow Fault
What is the Teledyne Detcon 952-T14200-701?The Teledyne Detcon 952-T14200-701 is: Model 1000 Analyzer, Single Channel, 20% CO2 by Vol. with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T14200-701 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T14200-801 Model 1000 Analyzer, Single Channel, 25% CO2 by Vol. with Air Flow Fault
What is the Teledyne Detcon 952-T14200-801?The Teledyne Detcon 952-T14200-801 is: Model 1000 Analyzer, Single Channel, 25% CO2 by Vol. with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T14200-801 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T14200-901 Model 1000 Analyzer, Single Channel, 100% CO2 by Vol. with Air Flow Fault
What is the Teledyne Detcon 952-T14200-901?The Teledyne Detcon 952-T14200-901 is: Model 1000 Analyzer, Single Channel, 100% CO2 by Vol. with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T14200-901 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T17300-A01 Model 1000 Analyzer, Single Channel, 0-10ppm H2S with Air Flow Fault
What is the Teledyne Detcon 952-T17300-A01?The Teledyne Detcon 952-T17300-A01 is: Model 1000 Analyzer, Single Channel, 0-10ppm H2S with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool. The Model 1000 Analyzers group in the Detcon price book lists 12 orderable part numbers; calibrated for the 0-10ppm range.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T17300-A01 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T17300-B01 Model 1000 Analyzer, Single Channel, 0-25ppm H2S with Air Flow Fault
What is the Teledyne Detcon 952-T17300-B01?The Teledyne Detcon 952-T17300-B01 is: Model 1000 Analyzer, Single Channel, 0-25ppm H2S with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool. The Model 1000 Analyzers group in the Detcon price book lists 12 orderable part numbers; calibrated for the 0-25ppm range.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T17300-B01 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T17300-C01 Model 1000 Analyzer, Single Channel, 0-50ppm H2S with Air Flow Fault
What is the Teledyne Detcon 952-T17300-C01?The Teledyne Detcon 952-T17300-C01 is: Model 1000 Analyzer, Single Channel, 0-50ppm H2S with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool. The Model 1000 Analyzers group in the Detcon price book lists 12 orderable part numbers; calibrated for the 0-50ppm range.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T17300-C01 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T17300-D01 Model 1000 Analyzer, Single Channel, 0-100ppm H2S with Air Flow Fault
What is the Teledyne Detcon 952-T17300-D01?The Teledyne Detcon 952-T17300-D01 is: Model 1000 Analyzer, Single Channel, 0-100ppm H2S with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool. The Model 1000 Analyzers group in the Detcon price book lists 12 orderable part numbers; calibrated for the 0-100ppm range.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T17300-D01 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 952-T17300-E01 Model 1000 Analyzer, Single Channel, 0-500ppm H2S with Air Flow Fault
What is the Teledyne Detcon 952-T17300-E01?The Teledyne Detcon 952-T17300-E01 is: Model 1000 Analyzer, Single Channel, 0-500ppm H2S with Air Flow Fault. The Teledyne Detcon Model 1000 Series is a family of fixed process gas analyzers that provide continuous, real-time measurement of hydrogen sulfide or carbon dioxide concentrations in process gas streams. The H2S version uses a Detcon DM-624 electrochemical sensor with analysis ranges from 0-10 ppm up to 0-5% H2S, while the CO2 version uses a plug-in replaceable non-dispersive infrared (NDIR) optical sensor covering ranges from 0.3% up to 100% CO2. Each analyzer includes an on-board sample conditioning system with pressure gauge, membrane separator, flow control valves, and rotameters, and requires a constant liquid-free sample at 10 plus or minus 2 psig. The transmitter provides a local digital display, fault supervision, and non-intrusive calibration via a hand-held magnetic programming tool. The Model 1000 Analyzers group in the Detcon price book lists 12 orderable part numbers; calibrated for the 0-500ppm range.Key specificationsSingle-channel analyzer with local digital display and magnetic non-intrusive programmingH2S version: electrochemical cell sensor, ranges 0-10 ppm up to 0-5% H2S, accuracy plus or minus 10% of reading or 0.5 ppm, T80 response under 1 minuteCO2 version: NDIR optical sensor (IR-640/IR-642), ranges 0.3% up to 5% and 10% up to 100% CO2, accuracy plus or minus 5% full scaleOutputs: linear 4-20mA DC, RS-485 Modbus, and 3 relays (alarm 1, alarm 2, fault) with contacts rated 5 AInput power: 110/220 VAC or 18-36 VDCSample inlet pressure 10 plus or minus 2 psig, with air dilution pump, activated carbon scrubber, and optional air flow fault and sample flow fault alarm boardsOperating temperature -40 C to +50 COptional full NEMA 4 enclosure; standard configuration is panel-mounted with weather protection recommendedWhere is it used?Typical service: Continuous H2S monitoring of process gas streams; Continuous CO2 monitoring of process gas streams; Gas quality monitoring where a pressurized sample line is available; Integration with plant control systems via 4-20mA or RS-485 Modbus.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 952-T17300-E01 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 1000 H2S analyzer we carry. -

Teledyne Detcon 954-R20260-000 NEMA 4X Remote I/O Module Enclosure includes 75 watt power supply, for use with up to 8
What is the Teledyne Detcon 954-R20260-000?The Teledyne Detcon 954-R20260-000 is: NEMA 4X Remote I/O Module Enclosure includes 75 watt power supply, for use with up to 8. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.About the Teledyne Detcon Model X40 Controller line8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterStackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 954-R20260-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry.