Teledyne Detcon 975-041400-000 Detcon Model RL-4 four relay alarm module
What is the Teledyne Detcon 975-041400-000?The Teledyne Detcon 975-041400-000 is: Detcon Model RL-4 four relay alarm module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-041400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 975-041401-000 Detcon Model AO-4 four channel analog output module
What is the Teledyne Detcon 975-041401-000?The Teledyne Detcon 975-041401-000 is: Detcon Model AO-4 four channel analog output module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-041401-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 975-041402-000 Detcon Model DI-4 four channel dry contact input module
What is the Teledyne Detcon 975-041402-000?The Teledyne Detcon 975-041402-000 is: Detcon Model DI-4 four channel dry contact input module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-041402-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 975-225007-006 Remote sensor separation Jbox, aluminum, 6 wire terminal strip
What is the Teledyne Detcon 975-225007-006?The Teledyne Detcon 975-225007-006 is: Remote sensor separation Jbox, aluminum, 6 wire terminal strip. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-225007-006 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-316007-006 Remote sensor separation Jbox, 316 stainless steel, 6 wire terminal strip
What is the Teledyne Detcon 975-316007-006?The Teledyne Detcon 975-316007-006 is: Remote sensor separation Jbox, 316 stainless steel, 6 wire terminal strip. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the 316 stainless steel variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-316007-006 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-424408-110 Nema 4X weatherproof 24 VDC 17 amp hour battery supply with line charger
What is the Teledyne Detcon 975-424408-110?The Teledyne Detcon 975-424408-110 is: Nema 4X weatherproof 24 VDC 17 amp hour battery supply with line charger. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-424408-110 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-424600-110 Nema 4X weatherproof 24 VDC 25 amp hour battery supply with line charger
What is the Teledyne Detcon 975-424600-110?The Teledyne Detcon 975-424600-110 is: Nema 4X weatherproof 24 VDC 25 amp hour battery supply with line charger. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-424600-110 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-600020-000 PID Replacement 10.6eV Lamp
What is the Teledyne Detcon 975-600020-000?The Teledyne Detcon 975-600020-000 is: PID Replacement 10.6eV Lamp. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-600020-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-600037-581 PID Replacement Filter Cap
What is the Teledyne Detcon 975-600037-581?The Teledyne Detcon 975-600037-581 is: PID Replacement Filter Cap. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-600037-581 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-600037-591 PID Replacement Filter Media – # 2
What is the Teledyne Detcon 975-600037-591?The Teledyne Detcon 975-600037-591 is: PID Replacement Filter Media - # 2. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-600037-591 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-600038-083 PID Replacement Filter Media – # 1
What is the Teledyne Detcon 975-600038-083?The Teledyne Detcon 975-600038-083 is: PID Replacement Filter Media - # 1. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-600038-083 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-600042-078 PID Replacement Spacer P2
What is the Teledyne Detcon 975-600042-078?The Teledyne Detcon 975-600042-078 is: PID Replacement Spacer P2. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-600042-078 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-600042-216 PID Replacement Cell Assembly
What is the Teledyne Detcon 975-600042-216?The Teledyne Detcon 975-600042-216 is: PID Replacement Cell Assembly. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-600042-216 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-70000A-00A Remote Control / Alarm Relay Module in Aluminum Enclosure
What is the Teledyne Detcon 975-70000A-00A?The Teledyne Detcon 975-70000A-00A is: Remote Control / Alarm Relay Module in Aluminum Enclosure. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Model 700 Series lineSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsEnclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-70000A-00A on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 975-70000A-00S Remote Control / Alarm Relay Module in 316SS Enclosure
What is the Teledyne Detcon 975-70000A-00S?The Teledyne Detcon 975-70000A-00S is: Remote Control / Alarm Relay Module in 316SS Enclosure. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the 316 stainless steel variant.About the Teledyne Detcon Model 700 Series lineSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsEnclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-70000A-00S on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 975-70000H-00A Remote Control / Alarm Relay Module with Hart in Aluminum Enclosure
What is the Teledyne Detcon 975-70000H-00A?The Teledyne Detcon 975-70000H-00A is: Remote Control / Alarm Relay Module with Hart in Aluminum Enclosure. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Model 700 Series lineSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsEnclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-70000H-00A on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 975-70000H-00S Remote Control / Alarm Relay Module with Hart in 316SS Enclosure
What is the Teledyne Detcon 975-70000H-00S?The Teledyne Detcon 975-70000H-00S is: Remote Control / Alarm Relay Module with Hart in 316SS Enclosure. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the 316 stainless steel variant.About the Teledyne Detcon Model 700 Series lineSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsEnclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-70000H-00S on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 975-70005H-00A Hart Integration Module in Aluminum Enclosure
What is the Teledyne Detcon 975-70005H-00A?The Teledyne Detcon 975-70005H-00A is: Hart Integration Module in Aluminum Enclosure. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Model 700 Series lineSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsEnclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-70005H-00A on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 975-70005H-00S Hart Integration Module in 316SS Enclosure
What is the Teledyne Detcon 975-70005H-00S?The Teledyne Detcon 975-70005H-00S is: Hart Integration Module in 316SS Enclosure. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the 316 stainless steel variant.About the Teledyne Detcon Model 700 Series lineSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsEnclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-70005H-00S on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 975-DISPDM-100 Loop-powered display assembly with AL J-Box
What is the Teledyne Detcon 975-DISPDM-100?The Teledyne Detcon 975-DISPDM-100 is: Loop-powered display assembly with AL J-Box. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-DISPDM-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 976-000304-004 Four Gang Battery Charger for Smart Rechargeable battery
What is the Teledyne Detcon 976-000304-004?The Teledyne Detcon 976-000304-004 is: Four Gang Battery Charger for Smart Rechargeable battery. The Model RXT-320 SmartWireless transceiver transmits signal data from 4-20 mA DC or serial Modbus field devices over a 2.4 GHz wireless network, eliminating point-to-point wiring in industrial detection and alarm systems. Installations range from a single field device talking to a controller up to 32 field device nodes forming a network with a controller, remote display, and audio/visual alarm stations. Network integrity is achieved with direct sequence spread spectrum mesh technology: every device can function as a router and repeater, so signals hop through neighboring devices and route around congestion and line-of-sight obstacles.About the Teledyne Detcon RXT-320 Wireless lineInputs: two analog 4-20 mA plus RS-485 Modbus RTU (9600 bps); outputs: four open collector outputsChannel capacity: 32 devices per network; mesh and point-to-point topologiesRadio: 2.40-2.48 GHz, 16 RF channels each 5 MHz wide, DSSS spread spectrum, O-QPSK modulation, 63 mW (18 dBm) EIRP, AES-128 encryption availableOutdoor RF line of sight: 1.5 miles with standard antenna; transceiver sensitivity -102 dBmPower: 7-30 VDC input, base unit consumption under 500 mW (20 mA max at 24 VDC); optional rechargeable lithium-ion battery pack with 12 VDC outputOperating temperature: -40 C to +75 CMounting options: transceiver only, aluminum J-Box with terminal board, or stainless steel J-Box with terminal boardWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Wastewater treatment plants; Food and beverage processing, pulp and paper mills; Refining and petrochemical.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-000304-004 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-000320-000 RXT-320 Radio/Antenna for N7X
What is the Teledyne Detcon 976-000320-000?The Teledyne Detcon 976-000320-000 is: RXT-320 Radio/Antenna for N7X. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-000320-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-000320-00E Model RXT-320 Wireless Transceiver
What is the Teledyne Detcon 976-000320-00E?The Teledyne Detcon 976-000320-00E is: Model RXT-320 Wireless Transceiver. The Model RXT-320 SmartWireless transceiver transmits signal data from 4-20 mA DC or serial Modbus field devices over a 2.4 GHz wireless network, eliminating point-to-point wiring in industrial detection and alarm systems. Installations range from a single field device talking to a controller up to 32 field device nodes forming a network with a controller, remote display, and audio/visual alarm stations. Network integrity is achieved with direct sequence spread spectrum mesh technology: every device can function as a router and repeater, so signals hop through neighboring devices and route around congestion and line-of-sight obstacles.Key specificationsInputs: two analog 4-20 mA plus RS-485 Modbus RTU (9600 bps); outputs: four open collector outputsChannel capacity: 32 devices per network; mesh and point-to-point topologiesRadio: 2.40-2.48 GHz, 16 RF channels each 5 MHz wide, DSSS spread spectrum, O-QPSK modulation, 63 mW (18 dBm) EIRP, AES-128 encryption availableOutdoor RF line of sight: 1.5 miles with standard antenna; transceiver sensitivity -102 dBmPower: 7-30 VDC input, base unit consumption under 500 mW (20 mA max at 24 VDC); optional rechargeable lithium-ion battery pack with 12 VDC outputSafety approval: cETLus Class I, Division 1, Groups C, DOperating temperature: -40 C to +75 CMounting options: transceiver only, aluminum J-Box with terminal board, or stainless steel J-Box with terminal boardWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Wastewater treatment plants; Food and beverage processing, pulp and paper mills; Refining and petrochemical.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-000320-00E on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-000321-000 Model RXT-320 w/Aluminum J-Box & Terminal Board
What is the Teledyne Detcon 976-000321-000?The Teledyne Detcon 976-000321-000 is: Model RXT-320 w/Aluminum J-Box & Terminal Board. The Model RXT-320 SmartWireless transceiver transmits signal data from 4-20 mA DC or serial Modbus field devices over a 2.4 GHz wireless network, eliminating point-to-point wiring in industrial detection and alarm systems. Installations range from a single field device talking to a controller up to 32 field device nodes forming a network with a controller, remote display, and audio/visual alarm stations. Network integrity is achieved with direct sequence spread spectrum mesh technology: every device can function as a router and repeater, so signals hop through neighboring devices and route around congestion and line-of-sight obstacles. The RXT-320 Wireless group in the Detcon price book lists 5 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon RXT-320 Wireless lineInputs: two analog 4-20 mA plus RS-485 Modbus RTU (9600 bps); outputs: four open collector outputsChannel capacity: 32 devices per network; mesh and point-to-point topologiesRadio: 2.40-2.48 GHz, 16 RF channels each 5 MHz wide, DSSS spread spectrum, O-QPSK modulation, 63 mW (18 dBm) EIRP, AES-128 encryption availableOutdoor RF line of sight: 1.5 miles with standard antenna; transceiver sensitivity -102 dBmPower: 7-30 VDC input, base unit consumption under 500 mW (20 mA max at 24 VDC); optional rechargeable lithium-ion battery pack with 12 VDC outputOperating temperature: -40 C to +75 CMounting options: transceiver only, aluminum J-Box with terminal board, or stainless steel J-Box with terminal boardWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Wastewater treatment plants; Food and beverage processing, pulp and paper mills; Refining and petrochemical.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-000321-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-000322-000 Model RXT-320 w/Stainless Steel J-Box & Terminal Board
What is the Teledyne Detcon 976-000322-000?The Teledyne Detcon 976-000322-000 is: Model RXT-320 w/Stainless Steel J-Box & Terminal Board. The Model RXT-320 SmartWireless transceiver transmits signal data from 4-20 mA DC or serial Modbus field devices over a 2.4 GHz wireless network, eliminating point-to-point wiring in industrial detection and alarm systems. Installations range from a single field device talking to a controller up to 32 field device nodes forming a network with a controller, remote display, and audio/visual alarm stations. Network integrity is achieved with direct sequence spread spectrum mesh technology: every device can function as a router and repeater, so signals hop through neighboring devices and route around congestion and line-of-sight obstacles. The RXT-320 Wireless group in the Detcon price book lists 5 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon RXT-320 Wireless lineInputs: two analog 4-20 mA plus RS-485 Modbus RTU (9600 bps); outputs: four open collector outputsChannel capacity: 32 devices per network; mesh and point-to-point topologiesRadio: 2.40-2.48 GHz, 16 RF channels each 5 MHz wide, DSSS spread spectrum, O-QPSK modulation, 63 mW (18 dBm) EIRP, AES-128 encryption availableOutdoor RF line of sight: 1.5 miles with standard antenna; transceiver sensitivity -102 dBmPower: 7-30 VDC input, base unit consumption under 500 mW (20 mA max at 24 VDC); optional rechargeable lithium-ion battery pack with 12 VDC outputOperating temperature: -40 C to +75 CMounting options: transceiver only, aluminum J-Box with terminal board, or stainless steel J-Box with terminal boardWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Wastewater treatment plants; Food and beverage processing, pulp and paper mills; Refining and petrochemical.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-000322-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-000327-100 Model RXT-320 with extended lid aluminum junction box and high output smart battery pack
What is the Teledyne Detcon 976-000327-100?The Teledyne Detcon 976-000327-100 is: Model RXT-320 with extended lid aluminum junction box and high output smart battery pack. The Model RXT-320 SmartWireless transceiver transmits signal data from 4-20 mA DC or serial Modbus field devices over a 2.4 GHz wireless network, eliminating point-to-point wiring in industrial detection and alarm systems. Installations range from a single field device talking to a controller up to 32 field device nodes forming a network with a controller, remote display, and audio/visual alarm stations. Network integrity is achieved with direct sequence spread spectrum mesh technology: every device can function as a router and repeater, so signals hop through neighboring devices and route around congestion and line-of-sight obstacles. The RXT-320 Wireless group in the Detcon price book lists 5 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon RXT-320 Wireless lineInputs: two analog 4-20 mA plus RS-485 Modbus RTU (9600 bps); outputs: four open collector outputsChannel capacity: 32 devices per network; mesh and point-to-point topologiesRadio: 2.40-2.48 GHz, 16 RF channels each 5 MHz wide, DSSS spread spectrum, O-QPSK modulation, 63 mW (18 dBm) EIRP, AES-128 encryption availableOutdoor RF line of sight: 1.5 miles with standard antenna; transceiver sensitivity -102 dBmPower: 7-30 VDC input, base unit consumption under 500 mW (20 mA max at 24 VDC); optional rechargeable lithium-ion battery pack with 12 VDC outputOperating temperature: -40 C to +75 CMounting options: transceiver only, aluminum J-Box with terminal board, or stainless steel J-Box with terminal boardWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Wastewater treatment plants; Food and beverage processing, pulp and paper mills; Refining and petrochemical.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-000327-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-0003BC-00T Battery Charger / Cord
What is the Teledyne Detcon 976-0003BC-00T?The Teledyne Detcon 976-0003BC-00T is: Battery Charger / Cord. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-0003BC-00T on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-001320-CHR Radio Module with charger circuit included
What is the Teledyne Detcon 976-001320-CHR?The Teledyne Detcon 976-001320-CHR is: Radio Module with charger circuit included. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-001320-CHR on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-00132D-000 Radio Module Din Rail Mount
What is the Teledyne Detcon 976-00132D-000?The Teledyne Detcon 976-00132D-000 is: Radio Module Din Rail Mount. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.About the Teledyne Detcon Mounting & Sensor Protection lineSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-00132D-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-041400-000 Detcon Model DA-4 four channel 4-20 maDC input module
What is the Teledyne Detcon 976-041400-000?The Teledyne Detcon 976-041400-000 is: Detcon Model DA-4 four channel 4-20 maDC input module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-041400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 976-042405-000 5 Db Rubber Antenna
What is the Teledyne Detcon 976-042405-000?The Teledyne Detcon 976-042405-000 is: 5 Db Rubber Antenna. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-042405-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-042407-000 High gain 7dB antenna with bracket
What is the Teledyne Detcon 976-042407-000?The Teledyne Detcon 976-042407-000 is: High gain 7dB antenna with bracket. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-042407-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-0BP303-290 Plug-in Smart Rechargeable Hi output (2900maH) Battery Pack
What is the Teledyne Detcon 976-0BP303-290?The Teledyne Detcon 976-0BP303-290 is: Plug-in Smart Rechargeable Hi output (2900maH) Battery Pack (for use with 12 and. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-0BP303-290 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-485485-000 RS-485 Isolated Repeater, 9-30VDC
What is the Teledyne Detcon 976-485485-000?The Teledyne Detcon 976-485485-000 is: RS-485 Isolated Repeater, 9-30VDC. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-485485-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 980-NTNT40-030 10 meter Antenna cable
What is the Teledyne Detcon 980-NTNT40-030?The Teledyne Detcon 980-NTNT40-030 is: 10 meter Antenna cable. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 980-NTNT40-030 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 980-SPXNJH-100 Antenna SS box fitting for 7 Db antenna/cable
What is the Teledyne Detcon 980-SPXNJH-100?The Teledyne Detcon 980-SPXNJH-100 is: Antenna SS box fitting for 7 Db antenna/cable. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 980-SPXNJH-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 980-SPXSJX-006 2 meter whip antenna extension
What is the Teledyne Detcon 980-SPXSJX-006?The Teledyne Detcon 980-SPXSJX-006 is: 2 meter whip antenna extension. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 980-SPXSJX-006 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 984-000000-000 Clear vinyl tubing 1/4 OD (price per foot)
What is the Teledyne Detcon 984-000000-000?The Teledyne Detcon 984-000000-000 is: Clear vinyl tubing 1/4 OD (price per foot). Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 984-000000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 984-200000-000 Teflon tubing 1/4 OD (price per foot)
What is the Teledyne Detcon 984-200000-000?The Teledyne Detcon 984-200000-000 is: Teflon tubing 1/4 OD (price per foot). Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 984-200000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 985-241100-321 In-line humidifying tube
What is the Teledyne Detcon 985-241100-321?The Teledyne Detcon 985-241100-321 is: In-line humidifying tube. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 985-241100-321 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 9H5-015420-100 TP-524D-HRT MOS H2S Sensor Assy w/HART alum condulet
What is the Teledyne Detcon 9H5-015420-100?The Teledyne Detcon 9H5-015420-100 is: TP-524D-HRT MOS H2S Sensor Assy w/HART alum condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port. The Model 500 Series group in the Detcon price book lists 8 orderable part numbers; this is the aluminum variant.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 9H5-015420-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 9H5-01542B-100 TP-524D-HRT MOS H2S Sensor Assy w/HART SS condulet
What is the Teledyne Detcon 9H5-01542B-100?The Teledyne Detcon 9H5-01542B-100 is: TP-524D-HRT MOS H2S Sensor Assy w/HART SS condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 9H5-01542B-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 9H5-525420-100 FP-524D-HRT Catalytic LEL Gas Sensor Assy w/HART Alum condulet
What is the Teledyne Detcon 9H5-525420-100?The Teledyne Detcon 9H5-525420-100 is: FP-524D-HRT Catalytic LEL Gas Sensor Assy w/HART Alum condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port. The Model 500 Series group in the Detcon price book lists 8 orderable part numbers; this is the aluminum variant.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 9H5-525420-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 9H5-52542B-100 FP-524D-HRT Catalytic LEL Gas Sensor Assy w/HART 316SS condulet
What is the Teledyne Detcon 9H5-52542B-100?The Teledyne Detcon 9H5-52542B-100 is: FP-524D-HRT Catalytic LEL Gas Sensor Assy w/HART 316SS condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port. The Model 500 Series group in the Detcon price book lists 8 orderable part numbers; this is the 316 stainless steel variant.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 9H5-52542B-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 9H7-303091-100M DM-700 Desert Climate electrochemical 0-100 ppm H2S sensor assembly with HART Integration
What is the Teledyne Detcon 9H7-303091-100M?The Teledyne Detcon 9H7-303091-100M is: DM-700 Desert Climate electrochemical 0-100 ppm H2S sensor assembly with HART Integration Module (HART protocol 7.0), aluminum junction box. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the aluminum variant and calibrated for the 0-100 ppm range.Key specificationsSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsCertifications (DM-700): cCSAus explosion proof Class I, Division 1, Groups B, C, D; ATEX II 2 G Ex d ib IIB+H2 T4 Gb; CE; SIL2 certified to IEC 61508Enclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 9H7-303091-100M on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry.