Teledyne Detcon 95P-X32000-000 Model X40-32-N1P, general purpose panel mount hardware assembly, 110/220 VAC, 24 VDC power
What is the Teledyne Detcon 95P-X32000-000?The Teledyne Detcon 95P-X32000-000 is: Model X40-32-N1P, general purpose panel mount hardware assembly, 110/220 VAC, 24 VDC power supply (up to 32 active channels). The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 95P-X32000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 95R-X32000-000 110/220 VAC 24 VDC pwr supply for 32 sensors Does not include optional I/O
What is the Teledyne Detcon 95R-X32000-000?The Teledyne Detcon 95R-X32000-000 is: 110/220 VAC 24 VDC pwr supply for 32 sensors Does not include optional I/O. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 95R-X32000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 960-202200-000 Condensation prevention packet (For condulet, replace annually)
What is the Teledyne Detcon 960-202200-000?The Teledyne Detcon 960-202200-000 is: Condensation prevention packet (For condulet, replace annually). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 960-202200-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 960-700PID-000 Moisture Control Packet for sensor
What is the Teledyne Detcon 960-700PID-000?The Teledyne Detcon 960-700PID-000 is: Moisture Control Packet for sensor. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 960-700PID-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 965-015420-100 TP-524D Solid State MOS H2S Sensor Assembly in alum condulet
What is the Teledyne Detcon 965-015420-100?The Teledyne Detcon 965-015420-100 is: TP-524D Solid State MOS H2S Sensor Assembly in alum condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port. The Model 500 Series group in the Detcon price book lists 8 orderable part numbers; this is the aluminum variant.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 965-015420-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 965-01542B-100 TP-524D-316SS Solid State MOS H2S Sensor Assembly in SS condulet
What is the Teledyne Detcon 965-01542B-100?The Teledyne Detcon 965-01542B-100 is: TP-524D-316SS Solid State MOS H2S Sensor Assembly in SS condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port. The Model 500 Series group in the Detcon price book lists 8 orderable part numbers; this is the 316 stainless steel variant.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 965-01542B-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 965-525420-100 FP-524D Catalytic Combustible Gas Sensor Assembly alum condulet
What is the Teledyne Detcon 965-525420-100?The Teledyne Detcon 965-525420-100 is: FP-524D Catalytic Combustible Gas Sensor Assembly alum condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port. The Model 500 Series group in the Detcon price book lists 8 orderable part numbers; this is the aluminum variant.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 965-525420-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 965-52542B-100 FP-524D-Catalytic Combustible Gas Sensor Assembly in 316 SS condulet
What is the Teledyne Detcon 965-52542B-100?The Teledyne Detcon 965-52542B-100 is: FP-524D-Catalytic Combustible Gas Sensor Assembly in 316 SS condulet. The Detcon Model 500 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, menu-driven calibration in under 3 minutes, and extensive fault diagnostics. The TP-524D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm with Detcon's solid state metal oxide semiconductor technology and responds like an electrochemical sensor (T50 under 30 seconds, T90 under 60 seconds), while the FP-524D monitors combustible gas over 0-100 percent LEL with matched-pair catalytic bead technology. Both deliver a standard linear 4-20 mA output with an optional HART communications module, and the plug-in transmitter design fits all existing Detcon MOS and catalytic bead sensors dating back more than 20 years. Assemblies ship in an explosion-proof junction box in aluminum or 316 stainless steel with a splashguard and integral calibration port. The Model 500 Series group in the Detcon price book lists 8 orderable part numbers; this is the 316 stainless steel variant.Key specificationsTP-524D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-524D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, T50 under 10 seconds, infinite shelf life, high poison resistanceOutputs: linear 4-20 mA DC with optional HART communicationsCertifications: cCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-524D; C, D for FP-524D); TP-524D also FM and ATEX Ex d IIB+H2 T4; FP-524D performance approved to CSA C22.2 #152 and ISA 12.13.01Ingress protection NEMA 4X, IP66Power input 12-28 VDC, under 2 W maximum consumptionExplosion-proof junction box in aluminum or 316 stainless steel; LED display with fault and calibration indicatorsNon-intrusive magnetic interface with self-adjusting zero and spanWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Offshore platforms, FPSOs, and LNG/CNG plants; Refining and petrochemical plants; Pulp and paper mills and wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 965-52542B-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 966-014520-100 TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet
What is the Teledyne Detcon 966-014520-100?The Teledyne Detcon 966-014520-100 is: TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet. The Detcon Model 600 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, a non-intrusive operator interface, and comprehensive fault diagnostics. The TP-624D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm using Detcon's proprietary solid state metal oxide semiconductor technology, and the FP-624D monitors combustible gas over 0-100 percent LEL using matched-pair catalytic bead technology. Beyond the standard 4-20 mA analog signal, the 600 Series adds an RS-485 Modbus RTU serial port and three programmable relays (two alarm plus one fault), making it directly compatible with PLC, SCADA, and DCS systems. The sensor assembly includes the detector in a stainless steel housing, an explosion-proof condulet in aluminum or 316 stainless steel, a plug-in transmitter, and a splashguard with integral calibration port. The Model 600 Series group in the Detcon price book lists 4 orderable part numbers; this is the aluminum variant.Key specificationsTP-624D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-624D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, accuracy plus or minus 3 percent (0-50 percent LEL), 3 to 5 year typical lifeOutputs: linear 4-20 mA DC, RS-485 Modbus RTU, and 3 relays (alarm 1, alarm 2, fault) rated 5 AcCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-624D; Groups C, D for FP-624D)TP-624D also carries ATEX Ex d IIB+H2 T4, CE marking, and a SIL2 FMEDA rating; FP-624D performance certified to CSA C22.2 #152Ingress protection IP66 (FP-624D NEMA 4X, IP66)Explosion-proof condulet available in aluminum or 316 stainless steel with LED display and magnetic programmingTransmitter design fits all existing Detcon MOS H2S and catalytic bead sensors dating back more than 20 yearsWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Refining and petrochemical plants; Pulp and paper mills; Wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 966-014520-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-624D combustible gas sensor we carry. -

Teledyne Detcon 966-01452B-100 TP-624D-316SS Solid State MOS H2S Sensor Assembly 316SS condulet
What is the Teledyne Detcon 966-01452B-100?The Teledyne Detcon 966-01452B-100 is: TP-624D-316SS Solid State MOS H2S Sensor Assembly 316SS condulet. The Detcon Model 600 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, a non-intrusive operator interface, and comprehensive fault diagnostics. The TP-624D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm using Detcon's proprietary solid state metal oxide semiconductor technology, and the FP-624D monitors combustible gas over 0-100 percent LEL using matched-pair catalytic bead technology. Beyond the standard 4-20 mA analog signal, the 600 Series adds an RS-485 Modbus RTU serial port and three programmable relays (two alarm plus one fault), making it directly compatible with PLC, SCADA, and DCS systems. The sensor assembly includes the detector in a stainless steel housing, an explosion-proof condulet in aluminum or 316 stainless steel, a plug-in transmitter, and a splashguard with integral calibration port. The Model 600 Series group in the Detcon price book lists 4 orderable part numbers; this is the 316 stainless steel variant.Key specificationsTP-624D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-624D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, accuracy plus or minus 3 percent (0-50 percent LEL), 3 to 5 year typical lifeOutputs: linear 4-20 mA DC, RS-485 Modbus RTU, and 3 relays (alarm 1, alarm 2, fault) rated 5 AcCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-624D; Groups C, D for FP-624D)TP-624D also carries ATEX Ex d IIB+H2 T4, CE marking, and a SIL2 FMEDA rating; FP-624D performance certified to CSA C22.2 #152Ingress protection IP66 (FP-624D NEMA 4X, IP66)Explosion-proof condulet available in aluminum or 316 stainless steel with LED display and magnetic programmingTransmitter design fits all existing Detcon MOS H2S and catalytic bead sensors dating back more than 20 yearsWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Refining and petrochemical plants; Pulp and paper mills; Wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 966-01452B-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-624D combustible gas sensor we carry. -

Teledyne Detcon 966-524520-100 FP-624D Catalytic Combustible Gas Sensor Assembly Alum condulet
What is the Teledyne Detcon 966-524520-100?The Teledyne Detcon 966-524520-100 is: FP-624D Catalytic Combustible Gas Sensor Assembly Alum condulet. The Detcon Model 600 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, a non-intrusive operator interface, and comprehensive fault diagnostics. The TP-624D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm using Detcon's proprietary solid state metal oxide semiconductor technology, and the FP-624D monitors combustible gas over 0-100 percent LEL using matched-pair catalytic bead technology. Beyond the standard 4-20 mA analog signal, the 600 Series adds an RS-485 Modbus RTU serial port and three programmable relays (two alarm plus one fault), making it directly compatible with PLC, SCADA, and DCS systems. The sensor assembly includes the detector in a stainless steel housing, an explosion-proof condulet in aluminum or 316 stainless steel, a plug-in transmitter, and a splashguard with integral calibration port. The Model 600 Series group in the Detcon price book lists 4 orderable part numbers; this is the aluminum variant.Key specificationsTP-624D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-624D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, accuracy plus or minus 3 percent (0-50 percent LEL), 3 to 5 year typical lifeOutputs: linear 4-20 mA DC, RS-485 Modbus RTU, and 3 relays (alarm 1, alarm 2, fault) rated 5 AcCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-624D; Groups C, D for FP-624D)TP-624D also carries ATEX Ex d IIB+H2 T4, CE marking, and a SIL2 FMEDA rating; FP-624D performance certified to CSA C22.2 #152Ingress protection IP66 (FP-624D NEMA 4X, IP66)Explosion-proof condulet available in aluminum or 316 stainless steel with LED display and magnetic programmingTransmitter design fits all existing Detcon MOS H2S and catalytic bead sensors dating back more than 20 yearsWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Refining and petrochemical plants; Pulp and paper mills; Wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 966-524520-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-624D combustible gas sensor we carry. -

Teledyne Detcon 966-52452B-100 FP-624D Catalytic Combustible Gas Sensor Assembly 316SS condulet
What is the Teledyne Detcon 966-52452B-100?The Teledyne Detcon 966-52452B-100 is: FP-624D Catalytic Combustible Gas Sensor Assembly 316SS condulet. The Detcon Model 600 Series are smart explosion-proof gas detection sensors with MicroSafe intelligent electronics, a non-intrusive operator interface, and comprehensive fault diagnostics. The TP-624D monitors hydrogen sulfide over 0-20, 0-50, or 0-100 ppm using Detcon's proprietary solid state metal oxide semiconductor technology, and the FP-624D monitors combustible gas over 0-100 percent LEL using matched-pair catalytic bead technology. Beyond the standard 4-20 mA analog signal, the 600 Series adds an RS-485 Modbus RTU serial port and three programmable relays (two alarm plus one fault), making it directly compatible with PLC, SCADA, and DCS systems. The sensor assembly includes the detector in a stainless steel housing, an explosion-proof condulet in aluminum or 316 stainless steel, a plug-in transmitter, and a splashguard with integral calibration port. The Model 600 Series group in the Detcon price book lists 4 orderable part numbers; this is the 316 stainless steel variant.Key specificationsTP-624D: CHEMFET solid state MOS H2S sensor, 0-20/0-50/0-100 ppm, 5 to 10 year typical life, 10 year conditional sensor warrantyFP-624D: matched-pair catalytic bead combustible sensor, 0-100 percent LEL, accuracy plus or minus 3 percent (0-50 percent LEL), 3 to 5 year typical lifeOutputs: linear 4-20 mA DC, RS-485 Modbus RTU, and 3 relays (alarm 1, alarm 2, fault) rated 5 AcCSAus explosion proof Class I, Division 1 (Groups B, C, D for TP-624D; Groups C, D for FP-624D)TP-624D also carries ATEX Ex d IIB+H2 T4, CE marking, and a SIL2 FMEDA rating; FP-624D performance certified to CSA C22.2 #152Ingress protection IP66 (FP-624D NEMA 4X, IP66)Explosion-proof condulet available in aluminum or 316 stainless steel with LED display and magnetic programmingTransmitter design fits all existing Detcon MOS H2S and catalytic bead sensors dating back more than 20 yearsWhere is it used?Typical service: Oil and gas drilling rigs and production sites; Refining and petrochemical plants; Pulp and paper mills; Wastewater treatment plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 966-52452B-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-624D combustible gas sensor we carry. -

Teledyne Detcon 967-303090-100M DM-700- Electro Chemical 0-100ppm H2S Sensor (DC) Assembly no condulet
What is the Teledyne Detcon 967-303090-100M?The Teledyne Detcon 967-303090-100M is: DM-700- Electro Chemical 0-100ppm H2S Sensor (DC) Assembly no condulet. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; calibrated for the 0-100ppm range.Key specificationsSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsCertifications (DM-700): cCSAus explosion proof Class I, Division 1, Groups B, C, D; ATEX II 2 G Ex d ib IIB+H2 T4 Gb; CE; SIL2 certified to IEC 61508Enclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 967-303090-100M on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 967-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly alum
What is the Teledyne Detcon 967-303091-100M?The Teledyne Detcon 967-303091-100M is: DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly alum. Condulet. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the aluminum variant and calibrated for the 0-100ppm range.Key specificationsSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsCertifications (DM-700): cCSAus explosion proof Class I, Division 1, Groups B, C, D; ATEX II 2 G Ex d ib IIB+H2 T4 Gb; CE; SIL2 certified to IEC 61508Enclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 967-303091-100M on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 967-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly 316SS condulet
What is the Teledyne Detcon 967-303094-100M?The Teledyne Detcon 967-303094-100M is: DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly 316SS condulet. The Teledyne Detcon Model 700 Series is a family of non-intrusive smart gas detection sensor modules built for harsh and extreme locations. The family covers the DM-700 electrochemical toxic gas and oxygen sensors, the TP-700 solid state MOS hydrogen sulfide sensor, the FP-700 catalytic combustible gas sensor, and the IR-700 infrared sensor for CO2 and combustible hydrocarbons. Every module uses an electropolished 316 stainless steel housing with fully encapsulated electronics, dual layer surge protection, and a plug-in field-replaceable sensor element, and is operated non-intrusively with a handheld magnet via a built-in alphanumeric LED display. Standard dual outputs are a linear 4-20 mA analog signal and Modbus RS-485, with HART, Remote Alarm Module, and SmartWireless integration options. The Model 700 Series group in the Detcon price book lists 16 orderable part numbers; this is the 316 stainless steel variant and calibrated for the 0-100ppm range.Key specificationsSensor technologies: 3-electrode electrochemical (DM-700), solid state metal oxide semiconductor (TP-700), matched-pair catalytic bead (FP-700), infrared (IR-700)Outputs: linear 4-20 mA DC plus Modbus RS-485 RTU standard; HART module (9H7), Remote Alarm Module with 2 alarm relays plus fault (9R7), and combined HART/RAM (9K7) integration optionsCertifications (DM-700): cCSAus explosion proof Class I, Division 1, Groups B, C, D; ATEX II 2 G Ex d ib IIB+H2 T4 Gb; CE; SIL2 certified to IEC 61508Enclosure: intrinsically safe electropolished 316 stainless steel sensor housing, 100 percent epoxy encapsulated circuitry, NEMA 4X / IP66; aluminum or 316 SS junction box optionsBuilt-in scrolling alphanumeric LED display with full-text menu prompts and non-intrusive magnetic programmingPlug-in intelligent sensor cells with automatic recognition of gas type and range and oversized gold-plated connectionsPower input 11-30 VDC; normal consumption under 0.75 W (DM-700)Desert Climate (DC) H2S electrochemical variants third-party tested to ISA 92.00.01-2010Where is it used?Typical service: Oil and gas facilities; Chemical plants and refineries; Pulp and paper mills; Wastewater treatment plants and utilities.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 967-303094-100M on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-700 / DM-700 / TP-700 detectors we carry. -

Teledyne Detcon 96C-08020 Model CXT-DM-Hbr, 0-30 ppm Hydrogen Bromide Sensor
What is the Teledyne Detcon 96C-08020?The Teledyne Detcon 96C-08020 is: Model CXT-DM-Hbr, 0-30 ppm Hydrogen Bromide Sensor. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-30 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-08020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-09020 Model CXT-DM-HCL, 0-30 ppm Hydrogen Chloride Sensor
What is the Teledyne Detcon 96C-09020?The Teledyne Detcon 96C-09020 is: Model CXT-DM-HCL, 0-30 ppm Hydrogen Chloride Sensor. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-30 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-09020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-13020 Model CXT-DM-HCN, 0-30 ppm Hydrogen Cyanide Sensor
What is the Teledyne Detcon 96C-13020?The Teledyne Detcon 96C-13020 is: Model CXT-DM-HCN, 0-30 ppm Hydrogen Cyanide Sensor. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-30 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-13020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-19020 Model CXT-DM-AsH3, 0-1 ppm Arsine Sensor Assembly
What is the Teledyne Detcon 96C-19020?The Teledyne Detcon 96C-19020 is: Model CXT-DM-AsH3, 0-1 ppm Arsine Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-1 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-19020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-20020 Model CXT-DM-PH3, 0-5 ppm Phosphine Sensor Assembly
What is the Teledyne Detcon 96C-20020?The Teledyne Detcon 96C-20020 is: Model CXT-DM-PH3, 0-5 ppm Phosphine Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-5 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-20020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-21020 Model CXT-DM-B2H6, 0-5 ppm Diborane Sensor Assembly
What is the Teledyne Detcon 96C-21020?The Teledyne Detcon 96C-21020 is: Model CXT-DM-B2H6, 0-5 ppm Diborane Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-5 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-21020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-24020 Model CXT-DM-H2S, 0-100 ppm Hydrogen Sulfide Sensor
What is the Teledyne Detcon 96C-24020?The Teledyne Detcon 96C-24020 is: Model CXT-DM-H2S, 0-100 ppm Hydrogen Sulfide Sensor. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-24020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-27020 Model CXT-DM-F2, 0-1 ppm Fluorine Sensor Assembly
What is the Teledyne Detcon 96C-27020?The Teledyne Detcon 96C-27020 is: Model CXT-DM-F2, 0-1 ppm Fluorine Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-1 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-27020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-33020 Model CXT-DM-HF SmartWireless toxic gas sensor assembly, 0-10 ppm Hydrogen Fluoride
What is the Teledyne Detcon 96C-33020?The Teledyne Detcon 96C-33020 is: Model CXT-DM-HF SmartWireless toxic gas sensor assembly, 0-10 ppm Hydrogen Fluoride (full ordering part number 96C-33020D-010 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-10 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-33020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-34020 Model CXT-DM-O2 SmartWireless sensor assembly, 0-25% volume Oxygen deficiency
What is the Teledyne Detcon 96C-34020?The Teledyne Detcon 96C-34020 is: Model CXT-DM-O2 SmartWireless sensor assembly, 0-25% volume Oxygen deficiency (full ordering part number 96C-34020D-025 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-25% volume range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-34020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-39020 Model CXT-DM-O3, 0-1 ppm Ozone Sensor Assembly
What is the Teledyne Detcon 96C-39020?The Teledyne Detcon 96C-39020 is: Model CXT-DM-O3, 0-1 ppm Ozone Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-1 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-39020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-44020 Model CXT-DM-CO SmartWireless toxic gas sensor assembly, 0-100 ppm Carbon Monoxide
What is the Teledyne Detcon 96C-44020?The Teledyne Detcon 96C-44020 is: Model CXT-DM-CO SmartWireless toxic gas sensor assembly, 0-100 ppm Carbon Monoxide (full ordering part number 96C-44020D-100 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-44020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-50020 Model CXT-DM-NH3, 0-100 ppm Ammonia Sensor Assembly
What is the Teledyne Detcon 96C-50020?The Teledyne Detcon 96C-50020 is: Model CXT-DM-NH3, 0-100 ppm Ammonia Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-50020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-55020 Model CXT-DM-SO2 SmartWireless toxic gas sensor assembly, 0-20 ppm Sulfur Dioxide
What is the Teledyne Detcon 96C-55020?The Teledyne Detcon 96C-55020 is: Model CXT-DM-SO2 SmartWireless toxic gas sensor assembly, 0-20 ppm Sulfur Dioxide (full ordering part number 96C-55020D-020 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-20 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-55020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-64020 Model CXT-DM-NO2 SmartWireless toxic gas sensor assembly, 0-10 ppm Nitrogen Dioxide
What is the Teledyne Detcon 96C-64020?The Teledyne Detcon 96C-64020 is: Model CXT-DM-NO2 SmartWireless toxic gas sensor assembly, 0-10 ppm Nitrogen Dioxide (full ordering part number 96C-64020D-010 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-10 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-64020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-74020 Model CXT-DM-CL2, 0-10 ppm Chlorine Sensor Assembly
What is the Teledyne Detcon 96C-74020?The Teledyne Detcon 96C-74020 is: Model CXT-DM-CL2, 0-10 ppm Chlorine Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-10 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-74020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-75020 Model CXT-DM-Br2, 0-5 ppm Bromine Sensor Assembly
What is the Teledyne Detcon 96C-75020?The Teledyne Detcon 96C-75020 is: Model CXT-DM-Br2, 0-5 ppm Bromine Sensor Assembly. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-5 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-75020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-76020 Model CXT-DM-CLO2 SmartWireless toxic gas sensor assembly, 0-50 ppm Chlorine Dioxide
What is the Teledyne Detcon 96C-76020?The Teledyne Detcon 96C-76020 is: Model CXT-DM-CLO2 SmartWireless toxic gas sensor assembly, 0-50 ppm Chlorine Dioxide (full ordering part number 96C-76020D-050 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-50 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-76020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-77020 Model CXT-DM-CLO2 SmartWireless toxic gas sensor assembly, 0-1 ppm Chlorine Dioxide
What is the Teledyne Detcon 96C-77020?The Teledyne Detcon 96C-77020 is: Model CXT-DM-CLO2 SmartWireless toxic gas sensor assembly, 0-1 ppm Chlorine Dioxide (full ordering part number 96C-77020D-001 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-1 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-77020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-94020 Model CXT-DM-NO SmartWireless toxic gas sensor assembly, 0-100 ppm Nitric Oxide
What is the Teledyne Detcon 96C-94020?The Teledyne Detcon 96C-94020 is: Model CXT-DM-NO SmartWireless toxic gas sensor assembly, 0-100 ppm Nitric Oxide (full ordering part number 96C-94020D-100 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-94020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-EA020 Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Acetaldehyde (C2H3O)
What is the Teledyne Detcon 96C-EA020?The Teledyne Detcon 96C-EA020 is: Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Acetaldehyde (C2H3O). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-EA020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-EB020 Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Butadiene (C4H6)
What is the Teledyne Detcon 96C-EB020?The Teledyne Detcon 96C-EB020 is: Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Butadiene (C4H6). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-EB020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-ED020 Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Ethylene (C2H4)
What is the Teledyne Detcon 96C-ED020?The Teledyne Detcon 96C-ED020 is: Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Ethylene (C2H4) (full ordering part number 96C-ED020D-100 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-ED020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-EE020 Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Methanol (CH3OH)
What is the Teledyne Detcon 96C-EE020?The Teledyne Detcon 96C-EE020 is: Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Methanol (CH3OH) (full ordering part number 96C-EE020D-100 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-EE020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-EK020 Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Methyl Mercaptan (CH3SH)
What is the Teledyne Detcon 96C-EK020?The Teledyne Detcon 96C-EK020 is: Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Methyl Mercaptan (CH3SH) (full ordering part number 96C-EK020D-100 with D cell battery pack). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-EK020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-EO020 Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Ethanol (C2H5OH)
What is the Teledyne Detcon 96C-EO020?The Teledyne Detcon 96C-EO020 is: Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Ethanol (C2H5OH). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-EO020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 96C-EZ020 Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Ethyl Mercaptan (C2H5SH)
What is the Teledyne Detcon 96C-EZ020?The Teledyne Detcon 96C-EZ020 is: Model CXT-DM SmartWireless toxic gas sensor assembly, 0-100 ppm Ethyl Mercaptan (C2H5SH). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 96C-EZ020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-000020-890 Sensor Duct Mount Kit LEL
What is the Teledyne Detcon 975-000020-890?The Teledyne Detcon 975-000020-890 is: Sensor Duct Mount Kit LEL. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.About the Teledyne Detcon Mounting & Sensor Protection lineSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-000020-890 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-000020-891 Sensor Duct Mount Kit TP
What is the Teledyne Detcon 975-000020-891?The Teledyne Detcon 975-000020-891 is: Sensor Duct Mount Kit TP. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.About the Teledyne Detcon Mounting & Sensor Protection lineSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-000020-891 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-000020-893 Sensor duct mount kit – 700 Series
What is the Teledyne Detcon 975-000020-893?The Teledyne Detcon 975-000020-893 is: Sensor duct mount kit – 700 Series. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.About the Teledyne Detcon Mounting & Sensor Protection lineSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-000020-893 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification.