Gas and Flame Detection Systems
Showing 586–630 of 884 results
-

Teledyne Detcon 399-602016-000 Stainless steel LEL sensor housings including plug-in sensor
What is the Teledyne Detcon 399-602016-000?The Teledyne Detcon 399-602016-000 is: Stainless steel LEL sensor housings including plug-in sensor. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 399-602016-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 399-800000-000 Solid State MOS H2S Sensor in Stainless Steel Housing
What is the Teledyne Detcon 399-800000-000?The Teledyne Detcon 399-800000-000 is: Solid State MOS H2S Sensor in Stainless Steel Housing. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 399-800000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 437-500000-000 Stainless steel tag
What is the Teledyne Detcon 437-500000-000?The Teledyne Detcon 437-500000-000 is: Stainless steel tag. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications. The Model 100 Series group in the Detcon price book lists 11 orderable part numbers; this is the stainless steel variant.Key specificationsElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsXP / intrinsically safe packaging with US and Canadian approvals (CSA, FM, ETL, UL) per the official product pagePlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 437-500000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 500-001794-004 Standard connector board Model series 600 sensors
What is the Teledyne Detcon 500-001794-004?The Teledyne Detcon 500-001794-004 is: Standard connector board Model series 600 sensors. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-001794-004 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-003087-100 Transient Protection Module (standard terminal board)
What is the Teledyne Detcon 500-003087-100?The Teledyne Detcon 500-003087-100 is: Transient Protection Module (standard terminal board). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-003087-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005065-007 Standard connector board Model series 400 & 500 sensors
What is the Teledyne Detcon 500-005065-007?The Teledyne Detcon 500-005065-007 is: Standard connector board Model series 400 & 500 sensors. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005065-007 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005134-100 Ram Terminal board
What is the Teledyne Detcon 500-005134-100?The Teledyne Detcon 500-005134-100 is: Ram Terminal board. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005134-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005180-100 CXT Smart Battery Terminal Board
What is the Teledyne Detcon 500-005180-100?The Teledyne Detcon 500-005180-100 is: CXT Smart Battery Terminal Board. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005180-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005194-000 Sensor Input Board
What is the Teledyne Detcon 500-005194-000?The Teledyne Detcon 500-005194-000 is: Sensor Input Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005194-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005221-100 Main control board w/display X40 N7X
What is the Teledyne Detcon 500-005221-100?The Teledyne Detcon 500-005221-100 is: Main control board w/display X40 N7X. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005221-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005221-200 Main control board w/display X40 N4X
What is the Teledyne Detcon 500-005221-200?The Teledyne Detcon 500-005221-200 is: Main control board w/display X40 N4X. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005221-200 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005230-100 Standard connector board Model series 400 & 500 sensors (old pn 500-005065-007)
What is the Teledyne Detcon 500-005230-100?The Teledyne Detcon 500-005230-100 is: Standard connector board Model series 400 & 500 sensors (old pn 500-005065-007). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005230-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005231-100 Standard connector board Model series 600 sensors (Old PN 500-001794-004)
What is the Teledyne Detcon 500-005231-100?The Teledyne Detcon 500-005231-100 is: Standard connector board Model series 600 sensors (Old PN 500-001794-004). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005231-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005242-300 Hart Bridge Module
What is the Teledyne Detcon 500-005242-300?The Teledyne Detcon 500-005242-300 is: Hart Bridge Module. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005242-300 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 600-003846-000 8″ Antenna Raydome Dust cover for whip antenna
What is the Teledyne Detcon 600-003846-000?The Teledyne Detcon 600-003846-000 is: 8" Antenna Raydome Dust cover for whip antenna. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 600-003846-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 600-610000-000 Sensor splash guard w/integral cal port TP-424/TP-524/TP-624
What is the Teledyne Detcon 600-610000-000?The Teledyne Detcon 600-610000-000 is: Sensor splash guard w/integral cal port TP-424/TP-524/TP-624. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 600-610000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 602-003152-000 Model 700 Housing Bottom Assembly, includes flame arrestor (FP-700 spare part)
What is the Teledyne Detcon 602-003152-000?The Teledyne Detcon 602-003152-000 is: Model 700 Housing Bottom Assembly, includes flame arrestor (FP-700 spare part). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 602-003152-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 602-003280-000 TP-700 Housing Bottom Assembly, includes flame arrestor
What is the Teledyne Detcon 602-003280-000?The Teledyne Detcon 602-003280-000 is: TP-700 Housing Bottom Assembly, includes flame arrestor. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 602-003280-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 602-003295-FLT PI-700 Splash guard adapter assembly with filter
What is the Teledyne Detcon 602-003295-FLT?The Teledyne Detcon 602-003295-FLT is: PI-700 Splash guard adapter assembly with filter. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.About the Teledyne Detcon Mounting & Sensor Protection lineSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 602-003295-FLT on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 602-003803-000 CXT / 700 DM Splashguard Adapter SS
What is the Teledyne Detcon 602-003803-000?The Teledyne Detcon 602-003803-000 is: CXT / 700 DM Splashguard Adapter SS. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 602-003803-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 602-004216-000 IR-700 Bottom Housing Assembly, includes flame arrestor
What is the Teledyne Detcon 602-004216-000?The Teledyne Detcon 602-004216-000 is: IR-700 Bottom Housing Assembly, includes flame arrestor. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 602-004216-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 602-004402-000 D-Sized Battery Pack Assembly (for 5 cell, replaceable, non-rechargeable)
What is the Teledyne Detcon 602-004402-000?The Teledyne Detcon 602-004402-000 is: D-Sized Battery Pack Assembly ( for 5 cell, replaceable, non-rechargeable) Does not. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 602-004402-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 612-400000-000 Sensor/Sintered Filter replacement wrench FP/DM/IR
What is the Teledyne Detcon 612-400000-000?The Teledyne Detcon 612-400000-000 is: Sensor/Sintered Filter replacement wrench FP/DM/IR. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 612-400000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 612-820000-000 Stainless steel LEL sensor housing with threaded insert
What is the Teledyne Detcon 612-820000-000?The Teledyne Detcon 612-820000-000 is: Stainless steel LEL sensor housing with threaded insert. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 612-820000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 613-120000-700 Sensor splash guard with integral cal-port – FP/DM/IR
What is the Teledyne Detcon 613-120000-700?The Teledyne Detcon 613-120000-700 is: Sensor splash guard with integral cal-port - FP/DM/IR. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 613-120000-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 7200 Plus Two Channel Gas Controller
What is the Teledyne Detcon 7200-Plus?The Teledyne Detcon 7200-Plus is: Two channel gas detection controller, configured to order (housing, power supply, input, output, relay, and alarm options). The Teledyne Detcon 7200 Plus is a two-channel fixed gas controller that provides simultaneous display and alarm functions for its monitored variables. A graphic LCD presents monitored data as bar graphs and engineering units, with three adjustable alarm levels per channel and nonvolatile memory that retains all configuration data indefinitely. Relay outputs drive beacons, horns, and other alarm events, and an optional RS-485 Modbus slave port allows up to 128 controllers to be multidropped onto a single data highway.Key specificationsTwo monitored channels with graphic LCD showing bar graphs, trends, and engineering unitsThree adjustable alarm levels per channel; nonvolatile configuration memoryTwo standard 5 A Form C relays, expandable with a six-relay discrete alarm board (dedicated Alarm 1, Alarm 2, and Fault relays per channel) or solid-state relay optionsInput power 100-240 VAC or 10-30 VDC with automatic backup switchover; base unit consumes about 1.5 WOption boards: dual 4-20mA analog input, dual bridge sensor input, dual 4-20mA output, RS-232/RS-485 Modbus RTU interface, Ethernet Modbus TCP, and 100 dB piezo audible alarmHousing options: NEMA 4X wall mount (polycarbonate or stainless steel), NEMA 4 painted steel wall mount, and NEMA 7 explosion-proof wall mount for Division 1 and 2 Groups B, C, DApprovals: CSA C22.2 No 1010.1 and ISA S82.02, CSA C22.2 No 152 for combustibles, UL 1604 / C22.2 No 213 (Division 2 Groups A, B, C, D), EN55011 and EN61000 (CE Mark)Where is it used?Typical service: Centralized display and alarming for one or two fixed gas detection points; Combustible and toxic gas monitoring in Class I Division 2 areas; Driving beacons, horns, and other alarm event devices; Multidrop Modbus integration with plant monitoring systems.How is it configured?The 7200 Plus is configured to order. Verified option groups include housing (NEMA 4X polycarbonate, NEMA 4 painted steel, NEMA 4X stainless steel, or NEMA 7 explosion-proof wall mount), power supply (AC, DC, and external 50 W Division 1 or Division 2 supplies), input boards, output and communication boards, relay boards, and audible and visual alarm options such as the 100 dB piezo alarm and light stacks.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 7200-Plus on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 7400 Plus Four Channel Gas Controller
What is the Teledyne Detcon 7400-Plus?The Teledyne Detcon 7400-Plus is: Four channel gas detection controller, configured to order (housing, power supply, input, output, relay, and alarm options). The Teledyne Detcon 7400 Plus is a four-channel fixed gas controller that provides simultaneous display and alarm functions for up to four monitored variables. A graphic LCD displays monitored data as bar graphs and engineering units, with three adjustable alarm levels per channel and nonvolatile memory that retains configuration data indefinitely. Relay outputs control beacons, horns, and other alarm events, and an optional RS-485 Modbus slave port allows up to 128 controllers on a single data highway.Key specificationsFour monitored channels with graphic LCD showing bar graphs and engineering unitsThree adjustable alarm levels per channel; nonvolatile configuration memoryStandard 5 A Form C dry contact relays, expandable with a six-relay discrete alarm board (10-0222) or solid-state relay optionsOption boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), and RS-232/RS-485 Modbus interface (10-0253)Power supply options include 50 W NEMA 4X Division 2 (10-0315) and 50 W NEMA 7 Division 1 (10-0314) suppliesHousing options: NEMA 4X polycarbonate, NEMA 4 painted steel, NEMA 4X stainless steel, and NEMA 7 explosion-proof wall mount enclosuresApprovals: CSA C22.2 No 1010.1 and ISA S82.02, CSA C22.2 No 152 for combustibles, UL 1604 / C22.2 No 213 (Division 2 Groups A, B, C, D), EN55011 and EN61000 (CE Mark)Where is it used?Typical service: Centralized display and alarming for up to four fixed gas detection points; Combustible and toxic gas monitoring in Class I Division 2 areas; Driving beacons, horns, and other alarm event devices; Multidrop Modbus integration with plant monitoring systems.How is it configured?The 7400 Plus is configured to order. Verified option groups include housing (NEMA 4X polycarbonate, NEMA 4 painted steel, NEMA 4X stainless steel, or NEMA 7 explosion-proof wall mount), power supply (AC, DC, and 50 W Division 1 or Division 2 supplies), input boards, output and communication boards, relay boards, and optional alarm devices such as light stacks.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 7400-Plus on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 823-101085-882 Genie Membrane Filter
What is the Teledyne Detcon 823-101085-882?The Teledyne Detcon 823-101085-882 is: Genie Membrane Filter. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 823-101085-882 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 8800 Multi-Channel Gas Controller
What is the Teledyne Detcon Model-8800?The Teledyne Detcon Model-8800 is: Multi-channel gas detection controller, CSA Class 1 Div 2, NEMA 4X housing, configured to order. The Teledyne 8800 controller provides simultaneous display and alarm functions for up to 16 input variables, combining the proven 7800 controller platform with advanced upgrades in one low-cost package. It offers 8 or 16 channel display modes with I/O modules arranged in groups of 8 channels, so systems can be configured economically. A QVGA color LCD displays monitored data as trends, bar graphs, and engineering units, with readouts that change color to indicate alarms, and a magnetic keypad allows non-intrusive operation in potentially hazardous locations.Key specificationsUp to 16 input channels; inputs include 12-bit 4-20mA (150 ohm impedance) and Modbus, with power supply terminals per channel for 2- or 3-wire transmittersThree independent alarm levels per channel with Relay Acknowledge silencing of external audible devicesFive standard SPDT 5 A alarm relays: HORN, FAULT, and three programmable alarm relaysEthernet Modbus TCP master/slave port with web server; two standard RS-485 ports plus two optional isolated ports for simultaneous Modbus master/slave operationOption cards: 16-bit 4-20mA outputs, 4-20mA inputs, discrete and programmable alarm relaysQVGA 320 x 240 TFT color LCD with LED backlight; SD card data logger records input values and events for more than 10 yearsPower 10-30 VDC (24 VDC nominal), 12 W max; power supply options include 150 W (10-0172) and 600 W (10-0307)Enclosures: wall mount NEMA 4X non-metallic, 316 stainless steel, explosion-proof (XP), and rack/panel mount; approvals CE, CSA C22.2 No 1010.1, C22.2 No 152 for combustibles, ISA S82.02, CSA Class I Div 2 Groups A, B, C, DWhere is it used?Typical service: Centralized display and alarming in critical multipoint gas monitoring; Gas and flame detection systems in Division 2 potentially hazardous areas; Plant integration via Modbus TCP, Ethernet gateway protocols, and RS-485; Remote sensor installations using push-button zero/span Cal Mode.How is it configured?The 8800 is configured to order. Verified option groups include enclosure (NEMA 4X non-metallic, 316 stainless steel, explosion-proof, or rack/panel mount), power supply (150 W or 600 W options), input option cards, 4-20mA output cards, and discrete and programmable alarm relay cards; its HORN relay and Relay Acknowledge feature support external audible alarm devices.How do I order or get a quote?PE Energy supplies the Teledyne Detcon Model-8800 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 8864 Multi-Channel Gas Controller
What is the Teledyne Detcon Model-8864?The Teledyne Detcon Model-8864 is: Multi-channel gas detection controller, configured to order. The Teledyne 8864 controller provides simultaneous display and alarm functions for up to 64 input variables, with 16, 32, 48, and 64 channel display modes and I/O modules arranged in groups of 16 channels for economical system configuration. It shares its user interface with the 16-channel 8800 controller, making mixed installations straightforward. A QVGA color LCD presents trends, bar graphs, zone screens, and engineering units with alarm color coding, and a standard magnetic keypad allows non-intrusive operation in potentially hazardous locations.Key specificationsUp to 64 input channels; input types include 12-bit 4-20mA (150 ohm impedance), Modbus, and wireless optionsThree independent alarm levels per channel with Relay Acknowledge silencing of external audible devicesFive standard SPDT 5 A alarm relays: HORN, FAULT, and three programmable alarm relaysEthernet Modbus TCP master/slave port with web server; RS-485 serial ports for simultaneous Modbus master/slave operation (two standard, two optional isolated)Option cards: 16-bit 4-20mA outputs, 4-20mA inputs, discrete and programmable alarm relays, and 12-bit 16-channel bridge sensor inputsQVGA 320 x 240 TFT color LCD; SD card data logger records minimum, maximum, and average values for one yearPower 10-30 VDC (24 VDC nominal), 12 W max; power supply options include 150 W (10-0172) and 600 W (10-0307)Enclosures: wall mount NEMA 4X non-metallic, 316 stainless steel, explosion-proof (XP), and rack/panel mount; approvals CSA C22.2 No 1010.1, C22.2 No 152 for combustibles, ISA S82.02, UL 1604 / C22.2 No 213 (NEMA 4X = Division 2 Groups A, B, C, D), EN55011 and EN61000 (CE Mark)Where is it used?Typical service: Large multipoint gas and flame monitoring systems up to 64 channels; Centralized alarm and display functions across up to eight zones; Gas detection in Division 2 potentially hazardous areas; Plant integration via Modbus TCP, Ethernet gateways, RS-485, and wireless inputs.How is it configured?The 8864 is configured to order. Verified option groups include enclosure (NEMA 4X non-metallic, 316 stainless steel, explosion-proof, or rack/panel mount), power supply (150 W or 600 W options), input option cards including bridge sensor inputs, 4-20mA output cards, and discrete and programmable alarm relay cards; its HORN relay and Relay Acknowledge feature support external audible alarm devices.How do I order or get a quote?PE Energy supplies the Teledyne Detcon Model-8864 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-410507-316 Standard 316SS junction box solid top
What is the Teledyne Detcon 897-410507-316?The Teledyne Detcon 897-410507-316 is: Standard 316SS junction box solid top. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the 316 stainless steel variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-410507-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-850000-010 Standard aluminum junction box with solid lid
What is the Teledyne Detcon 897-850000-010?The Teledyne Detcon 897-850000-010 is: Standard aluminum junction box with solid lid. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications. The Model 100 Series group in the Detcon price book lists 11 orderable part numbers; this is the aluminum variant.Key specificationsElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsXP / intrinsically safe packaging with US and Canadian approvals (CSA, FM, ETL, UL) per the official product pagePlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850000-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 897-850000-316 Stainless steel junction box with solid cover
What is the Teledyne Detcon 897-850000-316?The Teledyne Detcon 897-850000-316 is: Stainless steel junction box with solid cover. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications. The Model 100 Series group in the Detcon price book lists 11 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850000-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 897-850400-010 Standard aluminum junction box solid top
What is the Teledyne Detcon 897-850400-010?The Teledyne Detcon 897-850400-010 is: Standard aluminum junction box solid top. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the aluminum variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850400-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-850500-010 Standard aluminum junction box glass lens top
What is the Teledyne Detcon 897-850500-010?The Teledyne Detcon 897-850500-010 is: Standard aluminum junction box glass lens top. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the aluminum variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850500-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-850701-316 Standard 316SS junction box glass lens top
What is the Teledyne Detcon 897-850701-316?The Teledyne Detcon 897-850701-316 is: Standard 316SS junction box glass lens top. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the 316 stainless steel variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850701-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-850702-010 Standard aluminum junction box extended glass lens top
What is the Teledyne Detcon 897-850702-010?The Teledyne Detcon 897-850702-010 is: Standard aluminum junction box extended glass lens top. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the aluminum variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850702-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-850800-010 Standard aluminum junction box bottom
What is the Teledyne Detcon 897-850800-010?The Teledyne Detcon 897-850800-010 is: Standard aluminum junction box bottom. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the aluminum variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850800-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-850801-316 Standard 316SS junction box bottom
What is the Teledyne Detcon 897-850801-316?The Teledyne Detcon 897-850801-316 is: Standard 316SS junction box bottom. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the 316 stainless steel variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850801-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-850901-010 Standard aluminum junction box with lens cover
What is the Teledyne Detcon 897-850901-010?The Teledyne Detcon 897-850901-010 is: Standard aluminum junction box with lens cover. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications. The Model 100 Series group in the Detcon price book lists 11 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850901-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 897-850901-316 Stainless steel junction box with lens cover
What is the Teledyne Detcon 897-850901-316?The Teledyne Detcon 897-850901-316 is: Stainless steel junction box with lens cover. The Teledyne Detcon Model DM-100 Series are compact toxic gas and oxygen sensors that deliver a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor's range of detection. The sensor is packaged in an electropolished 316 stainless steel housing with a 3/4 inch NPT thread, and its signal conditioning electronics are completely encapsulated for durability in harsh industrial environments. The plug-in, field-replaceable sensor cell uses large surface area gold-plated pins that reduce the effects of corrosion, and Teledyne lists cells for more than 25 gases including hydrogen sulfide, carbon monoxide, ammonia, chlorine, sulfur dioxide, and oxygen. Each sensor ships with a splash guard with integral calibration port, and options include aluminum or stainless steel upper enclosures with transient protection terminal board, a loop-powered digital display, and wireless communications. The Model 100 Series group in the Detcon price book lists 11 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Model 100 Series lineElectrochemical plug-in sensor cells for 25+ toxic gases and oxygen, per the official gas listOutput: 2-wire loop-powered 4-20 mA current signalElectropolished 316 stainless steel housing with 3/4 inch NPT thread; fully encapsulated electronicsPlug-in, field-replaceable sensor cell with large surface area gold-plated pinsAluminum or stainless steel junction box options with transient protection terminal boardShips with splash guard with integral calibration port; loop-powered display and wireless communication accessories availableWhere is it used?Typical service: Fixed-point toxic gas monitoring in harsh industrial environments; Hazardous-area installations requiring simple 2-wire 4-20 mA loops; Oxygen deficiency and toxic gas leak monitoring around process equipment.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850901-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 897-850902-010 Standard aluminum junction box with extended lens cover
What is the Teledyne Detcon 897-850902-010?The Teledyne Detcon 897-850902-010 is: Standard aluminum junction box with extended lens cover. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Junction Boxes & Enclosures lineNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-850902-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-860000-316 316SS Mini Condulet w/Solid Cover
What is the Teledyne Detcon 897-860000-316?The Teledyne Detcon 897-860000-316 is: 316SS Mini Condulet w/Solid Cover. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the 316 stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-860000-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-860001-316 Mini 316SS junction box with solid lid
What is the Teledyne Detcon 897-860001-316?The Teledyne Detcon 897-860001-316 is: Mini 316SS junction box with solid lid. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the 316 stainless steel variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-860001-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 897-860401-316 Mini 316SS junction box solid top
What is the Teledyne Detcon 897-860401-316?The Teledyne Detcon 897-860401-316 is: Mini 316SS junction box solid top. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible. The Junction Boxes & Enclosures group in the Detcon price book lists 12 orderable part numbers; this is the 316 stainless steel variant.Key specificationsNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 897-860401-316 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification.