Gas and Flame Detection Systems
Showing 541–585 of 884 results
-

Teledyne Detcon 371-505000-100 NH3, Ammonia plug-in sensor for DM-100
What is the Teledyne Detcon 371-505000-100?The Teledyne Detcon 371-505000-100 is: NH3, Ammonia plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-505000-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-5050U0-100 NH3, Ammonia plug-in sensor for CXT/CX
What is the Teledyne Detcon 371-5050U0-100?The Teledyne Detcon 371-5050U0-100 is: NH3, Ammonia plug-in sensor for CXT/CX. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-5050U0-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 371-555500-020 SO2, Sulfur Dioxide plug-in sensor for DM-100
What is the Teledyne Detcon 371-555500-020?The Teledyne Detcon 371-555500-020 is: SO2, Sulfur Dioxide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-555500-020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-646400-010 NO2, Nitrogen Dioxide plug-in sensor for DM-100
What is the Teledyne Detcon 371-646400-010?The Teledyne Detcon 371-646400-010 is: NO2, Nitrogen Dioxide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-646400-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-747400-010 Cl2, Chlorine plug-in sensor for DM-100
What is the Teledyne Detcon 371-747400-010?The Teledyne Detcon 371-747400-010 is: Cl2, Chlorine plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-747400-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-747500-005 Br2, Bromine plug-in sensor for DM-100
What is the Teledyne Detcon 371-747500-005?The Teledyne Detcon 371-747500-005 is: Br2, Bromine plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-747500-005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-777700-001 ClO2, Chlorine Dioxide 0-1 ppm plug-in sensor for DM-100
What is the Teledyne Detcon 371-777700-001?The Teledyne Detcon 371-777700-001 is: ClO2, Chlorine Dioxide 0-1 ppm plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen. The Model 100 Replacement Sensors group in the Detcon price book lists 32 orderable part numbers; calibrated for the 0-1 ppm range.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-777700-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-848400-100 H2, Hydrogen (ppm range)plug-in sensor for DM-100
What is the Teledyne Detcon 371-848400-100?The Teledyne Detcon 371-848400-100 is: H2, Hydrogen (ppm range)plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-848400-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-949400-100 NO, Nitric Oxide plug-in sensor for DM-100
What is the Teledyne Detcon 371-949400-100?The Teledyne Detcon 371-949400-100 is: NO, Nitric Oxide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-949400-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-IR1II1-000 Replacement plug-in NDIR sensor cell for Model CX-IR and CXT-IR combustible gas sensors
What is the Teledyne Detcon 371-IR1II1-000?The Teledyne Detcon 371-IR1II1-000 is: Replacement plug-in NDIR sensor cell for Model CX-IR and CXT-IR combustible gas sensors, 0-100% LEL hydrocarbon. Per the CXT-IR manual, the CXT-IR must only use IR cell model 371-IR1II1-000 or 371-IR1II1-EXD (extended temperature range). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts. The CXT SmartWireless group in the Detcon price book lists 45 orderable part numbers; calibrated for the 0-100% lel range.Key specificationsSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasHazardous area approvals: cCSAus Class I, Division 1, Groups C, D; Class I, Zone 1, Group IIB; ATEX and IECEx Ex db ib IIB T4 Gb (D cell disposable battery version)NEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-IR1II1-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 377-050501-04P H2, Hydrogen (0-4% Vol.) plug-in sensor for DM-700
What is the Teledyne Detcon 377-050501-04P?The Teledyne Detcon 377-050501-04P is: H2, Hydrogen (0-4% Vol.) plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-4% vol. range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-050501-04P on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-070701-01P H2, Hydrogen (0-1% Vol.) plug-in sensor for DM-700
What is the Teledyne Detcon 377-070701-01P?The Teledyne Detcon 377-070701-01P is: H2, Hydrogen (0-1% Vol.) plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-1% vol. range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-070701-01P on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-090801-030 HBr, Hydrogen Bromide plug-in sensor for DM-700
What is the Teledyne Detcon 377-090801-030?The Teledyne Detcon 377-090801-030 is: HBr, Hydrogen Bromide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-090801-030 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-090901-030 HCL, Hydrogen Chloride plug-in sensor for DM-700
What is the Teledyne Detcon 377-090901-030?The Teledyne Detcon 377-090901-030 is: HCL, Hydrogen Chloride plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-090901-030 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-12EB01-100 C4H6, Butadiene plug-in sensor for DM-700
What is the Teledyne Detcon 377-12EB01-100?The Teledyne Detcon 377-12EB01-100 is: C4H6, Butadiene plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-12EB01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-12ED01-100 C2H4, Ethylene plug-in sensor for DM-700
What is the Teledyne Detcon 377-12ED01-100?The Teledyne Detcon 377-12ED01-100 is: C2H4, Ethylene plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-12ED01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-12EE01-100 CH3OH, Methanol plug-in sensor for DM-700
What is the Teledyne Detcon 377-12EE01-100?The Teledyne Detcon 377-12EE01-100 is: CH3OH, Methanol plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-12EE01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-12EG01-100 C2H2, Acetylene plug-in sensor for DM-700
What is the Teledyne Detcon 377-12EG01-100?The Teledyne Detcon 377-12EG01-100 is: C2H2, Acetylene plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-12EG01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-12EJ01-100 C2H4O, Ethylene Oxide plug-in sensor for DM-700
What is the Teledyne Detcon 377-12EJ01-100?The Teledyne Detcon 377-12EJ01-100 is: C2H4O, Ethylene Oxide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-12EJ01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-12EO01-100 C2H5OH, Ethanol plug-in sensor for DM-700
What is the Teledyne Detcon 377-12EO01-100?The Teledyne Detcon 377-12EO01-100 is: C2H5OH, Ethanol plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-12EO01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-12EP01-100 CH2O, Formaldehyde plug-in sensor for DM-700
What is the Teledyne Detcon 377-12EP01-100?The Teledyne Detcon 377-12EP01-100 is: CH2O, Formaldehyde plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-12EP01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-131301-030 HCN, Hydrogen Cyanide plug-in sensor for DM-700
What is the Teledyne Detcon 377-131301-030?The Teledyne Detcon 377-131301-030 is: HCN, Hydrogen Cyanide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-131301-030 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-191901-001 AsH3, Arsine plug-in sensor for DM-700
What is the Teledyne Detcon 377-191901-001?The Teledyne Detcon 377-191901-001 is: AsH3, Arsine plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-191901-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-192001-005 PH3, Phosphine plug-in sensor for DM-700
What is the Teledyne Detcon 377-192001-005?The Teledyne Detcon 377-192001-005 is: PH3, Phosphine plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-192001-005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-192101-001 B2H6, Diborane plug-in sensor for DM-700
What is the Teledyne Detcon 377-192101-001?The Teledyne Detcon 377-192101-001 is: B2H6, Diborane plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-192101-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-242401-100 H2S, Hydrogen Sulfide plug-in sensor for DM-700
What is the Teledyne Detcon 377-242401-100?The Teledyne Detcon 377-242401-100 is: H2S, Hydrogen Sulfide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-242401-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-24EK01-100 CH3SH, Methyl Mercaptan plug-in sensor for DM-700
What is the Teledyne Detcon 377-24EK01-100?The Teledyne Detcon 377-24EK01-100 is: CH3SH, Methyl Mercaptan plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-24EK01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-24EZ01-100 C2H5SH, Ethyl Mercaptan plug-in sensor for DM-700
What is the Teledyne Detcon 377-24EZ01-100?The Teledyne Detcon 377-24EZ01-100 is: C2H5SH, Ethyl Mercaptan plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-24EZ01-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-272701-001 F2, Fluorine plug-in sensor for DM-700
What is the Teledyne Detcon 377-272701-001?The Teledyne Detcon 377-272701-001 is: F2, Fluorine plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-272701-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-303001-100 H2S, Hydrogen Sulfide 0-100 ppm plug-in sensor for DM-700, Desert Climate (DC) version; DC
What is the Teledyne Detcon 377-303001-100?The Teledyne Detcon 377-303001-100 is: H2S, Hydrogen Sulfide 0-100 ppm plug-in sensor for DM-700, Desert Climate (DC) version; DC sensors are third-party tested to the ISA 92.00.01-2010 standard. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-100 ppm range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-303001-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-333301-010 HF, Hydrogen Fluoride plug-in sensor for DM-700
What is the Teledyne Detcon 377-333301-010?The Teledyne Detcon 377-333301-010 is: HF, Hydrogen Fluoride plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-333301-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-343401-025 O2, Oxygen plug-in sensor for DM-700
What is the Teledyne Detcon 377-343401-025?The Teledyne Detcon 377-343401-025 is: O2, Oxygen plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-343401-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-393901-001 O3, Ozone plug-in sensor for DM-700
What is the Teledyne Detcon 377-393901-001?The Teledyne Detcon 377-393901-001 is: O3, Ozone plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-393901-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-444401-100 CO, Carbon Monoxide plug-in sensor for DM-700
What is the Teledyne Detcon 377-444401-100?The Teledyne Detcon 377-444401-100 is: CO, Carbon Monoxide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-444401-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-5050U1-100 NH3, Ammonia plug-in sensor for DM-702
What is the Teledyne Detcon 377-5050U1-100?The Teledyne Detcon 377-5050U1-100 is: NH3, Ammonia plug-in sensor for DM-702. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-5050U1-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-555501-020 SO2, Sulfur Dioxide plug-in sensor for DM-700
What is the Teledyne Detcon 377-555501-020?The Teledyne Detcon 377-555501-020 is: SO2, Sulfur Dioxide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-555501-020 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-646401-010 NO2, Nitrogen Dioxide plug-in sensor for DM-700
What is the Teledyne Detcon 377-646401-010?The Teledyne Detcon 377-646401-010 is: NO2, Nitrogen Dioxide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-646401-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-747401-010 Cl2, Chlorine plug-in sensor for DM-700
What is the Teledyne Detcon 377-747401-010?The Teledyne Detcon 377-747401-010 is: Cl2, Chlorine plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-747401-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-747501-005 Br2, Bromine plug-in sensor for DM-700
What is the Teledyne Detcon 377-747501-005?The Teledyne Detcon 377-747501-005 is: Br2, Bromine plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-747501-005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-747601-050 ClO2, Chlorine Dioxide 0-50 ppm plug-in sensor for DM-700
What is the Teledyne Detcon 377-747601-050?The Teledyne Detcon 377-747601-050 is: ClO2, Chlorine Dioxide 0-50 ppm plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-50 ppm range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-747601-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-777701-001 ClO2, Chlorine Dioxide 0-1 ppm plug-in sensor for DM-700
What is the Teledyne Detcon 377-777701-001?The Teledyne Detcon 377-777701-001 is: ClO2, Chlorine Dioxide 0-1 ppm plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-1 ppm range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-777701-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-848401-100 H2, Hydrogen (ppm range) plug-in sensor for DM-700
What is the Teledyne Detcon 377-848401-100?The Teledyne Detcon 377-848401-100 is: H2, Hydrogen (ppm range) plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-848401-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-949401-100 NO, Nitric Oxide plug-in sensor for DM-700
What is the Teledyne Detcon 377-949401-100?The Teledyne Detcon 377-949401-100 is: NO, Nitric Oxide plug-in sensor for DM-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-949401-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-PB0000-010 Photo Ionization plug-in sensor for PI-700-10 (0-10ppm)
What is the Teledyne Detcon 377-PB0000-010?The Teledyne Detcon 377-PB0000-010 is: Photo Ionization plug-in sensor for PI-700-10 (0-10ppm). These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-10ppm range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-PB0000-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 377-PM0000-01K Photo Ionization plug-in sensor for PI-701-1K (0-1000ppm)
What is the Teledyne Detcon 377-PM0000-01K?The Teledyne Detcon 377-PM0000-01K is: Photo Ionization plug-in sensor for PI-701-1K (0-1000ppm). These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-1000ppm range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 377-PM0000-01K on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry.