Gas and Flame Detection Systems
Showing 406–450 of 884 results
-

Teledyne Detcon 068-0005 TEFLON PFA Tubing, 1/4” OD, 1’
What is the Teledyne Detcon 068-0005?The Teledyne Detcon 068-0005 is: TEFLON PFA Tubing, 1/4” OD, 1’. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 068-0005-010 TEFLON PFA Tubing, 1/4″OD, 10′
What is the Teledyne Detcon 068-0005-010?The Teledyne Detcon 068-0005-010 is: TEFLON PFA Tubing, 1/4"OD, 10'. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0005-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 068-0005-025 TEFLON PFA Tubing, 1/4″OD, 25′
What is the Teledyne Detcon 068-0005-025?The Teledyne Detcon 068-0005-025 is: TEFLON PFA Tubing, 1/4"OD, 25'. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0005-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 068-0007-001 1/8 ID, 1/4 OD, TYGON Tubing, 1′
What is the Teledyne Detcon 068-0007-001?The Teledyne Detcon 068-0007-001 is: 1/8 ID, 1/4 OD, TYGON Tubing, 1'. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0007-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 068-0007-010 1/8 ID, 1/4 OD, TYGON Tubing, 10′
What is the Teledyne Detcon 068-0007-010?The Teledyne Detcon 068-0007-010 is: 1/8 ID, 1/4 OD, TYGON Tubing, 10'. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0007-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 068-0007-025 1/8 ID, 1/4 OD, TYGON Tubing, 25′
What is the Teledyne Detcon 068-0007-025?The Teledyne Detcon 068-0007-025 is: 1/8 ID, 1/4 OD, TYGON Tubing, 25'. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0007-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 068-0007-050 1/8 ID, 1/4 OD, TYGON Tubing, 50′
What is the Teledyne Detcon 068-0007-050?The Teledyne Detcon 068-0007-050 is: 1/8 ID, 1/4 OD, TYGON Tubing, 50'. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0007-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 068-0007-075 1/8 ID, 1/4 OD, TYGON Tubing, 75′
What is the Teledyne Detcon 068-0007-075?The Teledyne Detcon 068-0007-075 is: 1/8 ID, 1/4 OD, TYGON Tubing, 75'. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 068-0007-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 074-0208 Tygon T-Piece (for dilution system)
What is the Teledyne Detcon 074-0208?The Teledyne Detcon 074-0208 is: Tygon T-Piece (for dilution system). Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 074-0208 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 077-0023 Hard Sided Carrying Case for 58L/103L
What is the Teledyne Detcon 077-0023?The Teledyne Detcon 077-0023 is: Hard Sided Carrying Case for 58L/103L. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 077-0023 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 096-2101 1/4 Turn Calibration Adapator
What is the Teledyne Detcon 096-2101?The Teledyne Detcon 096-2101 is: 1/4 Turn Calibration Adapator. Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.Key specificationsDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 096-2101 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 096-3242 Calibration Adapter Assembly (Non ATEX)
What is the Teledyne Detcon 096-3242?The Teledyne Detcon 096-3242 is: Calibration Adapter Assembly (Non ATEX). Factory-specified span gases, zero air, fixed flow regulators, humidifiers, tubing, and cased span gas kits for calibrating Teledyne Detcon fixed gas detectors. Detcon instruction manuals call out calibration equipment by part number for the 700 series (FP-700, TP-700, IR-700), Model 100 series, and Model 1000 process analyzers, for example 25% or 50% LEL methane in air for the FP-700 and 25 ppm H2S in air for the TP-700. Span gas kits bundle a calibration adapter, span gas humidifier, fixed flow regulator, and carrying case, with gas cylinders ordered separately.About the Teledyne Detcon Calibration Gases & Kits lineDisposable aluminum calibration gas cylinders offered in 34 L, 58 L, and 105 L sizes; the 104 L 50% LEL methane cylinder (942-520124-050) is rated for approximately 175 calibrationsFixed flow regulators in 200 cc/min, 500 cc/min, and 1.0 L/min flow ratingsStainless steel regulators specified for reactive gases such as NH3, Cl2, and HCl; standard regulators for non-reactive gasesHighly Reactive Gas (HRG) span gas kit variant with Teflon tubing for NH3, Cl2, HCl, and HBr sensorsGas types span LEL methane, H2S, CO, NH3, SO2, and zero air, matched to sensor type and rangeSensor splash guard with integral calibration port (613-120000-700) allows gas application without removing the detector from serviceWhere is it used?Typical service: Routine AutoZero and AutoSpan calibration of Detcon fixed gas detectors; Bump testing and zero checks of installed sensors; Field calibration of reactive gas sensors using stainless steel regulators and Teflon tubing.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 096-3242 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0172 85-240VAC Universal Input 150 Watt 24VDC Power Supply
What is the Teledyne Detcon 10-0172?The Teledyne Detcon 10-0172 is: 85-240VAC Universal Input 150 Watt 24VDC Power Supply. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0172 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0178 NEMA 4X Expansion Enclosure For Up To 8 Option PCB’s
What is the Teledyne Detcon 10-0178?The Teledyne Detcon 10-0178 is: NEMA 4X Expansion Enclosure For Up To 8 Option PCB's. NEMA 7 rated condulet-style junction boxes in aluminum and 316 stainless steel used to mount and wire Teledyne Detcon fixed gas sensor assemblies, including the 700 series (FP-700, TP-700, IR-700) and Model 100 series, plus the RAM 700 remote alarm module. Sensors thread into a downward-facing 3/4 inch NPT female hub on the enclosure base. Covers are offered as solid (blank), glass lens (window), and extended lens versions so the sensor display remains visible.About the Teledyne Detcon Junction Boxes & Enclosures lineNEMA 7 rating for the standard aluminum and 316 stainless steel condulet enclosuresMaterials: copper-free aluminum or 316 stainless steel; base, cover, and bottom sections ordered separatelyDownward-facing 3/4 inch NPT female sensor connection; standard base has 3 portsStainless steel junction box 12.5 in H x 6.1 in W x 4 in D; aluminum junction box 13 in H x 6.1 in W x 4 in D; mounting holes on 5.5 in centersAssembled weight approximately 6 lb with aluminum junction box and 9 lb with stainless steel junction box (FP-700 sensor assembly)NEMA 4X expansion enclosure available for Model 1000 series analyzer option boardsWhere is it used?Typical service: Hazardous-area field wiring and mounting of Detcon fixed gas sensors; Display visibility and magnetic programming access through glass lens covers; Housing expansion option boards for Detcon analyzer systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0178 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0180 NEMA 4X Expansion Kit (Adds up to 4 Option Positions)
What is the Teledyne Detcon 10-0180?The Teledyne Detcon 10-0180 is: NEMA 4X Expansion Kit (Adds up to 4 Option Positions). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0180 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0181 NEMA 7 Expansion Kit (Adds Up To 3 Option Positions)
What is the Teledyne Detcon 10-0181?The Teledyne Detcon 10-0181 is: NEMA 7 Expansion Kit (Adds Up To 3 Option Positions). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0181 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0219 Dual Wheatstone Bridge Input Board
What is the Teledyne Detcon 10-0219?The Teledyne Detcon 10-0219 is: Dual Wheatstone Bridge Input Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0219 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0221/DUAL Dual 4-20mA Input Board
What is the Teledyne Detcon 10-0221/DUAL?The Teledyne Detcon 10-0221/DUAL is: Dual 4-20mA Input Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0221/DUAL on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0221/QUAD Quad 4-20mA Input Board
What is the Teledyne Detcon 10-0221/QUAD?The Teledyne Detcon 10-0221/QUAD is: Quad 4-20mA Input Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0221/QUAD on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0222 Six relay Option Board
What is the Teledyne Detcon 10-0222?The Teledyne Detcon 10-0222 is: Six relay Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0222 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0223 4-20mA output Board
What is the Teledyne Detcon 10-0223?The Teledyne Detcon 10-0223 is: 4-20mA output Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0223 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0284 Div 2 Red Strobe Local
What is the Teledyne Detcon 10-0284?The Teledyne Detcon 10-0284 is: Div 2 Red Strobe Local. Local visual alarm devices offered with Teledyne Detcon gas detection controllers and Model 1000 series analyzer systems. The group covers red alarm strobes in general purpose and Class I Division 2 versions for local alarm annunciation at the monitored equipment. Detcon also documents relay-based alarm signaling through its controller and remote alarm module products, which these strobes connect to.About the Teledyne Detcon Alarm Stations & Signals lineRed strobe signals in general purpose (GP) and Division 2 rated versionsOffered as local alarm options and spares for Detcon Model 1000 series analyzer and controller packagesDriven by alarm relay outputs of Detcon controllers and alarm modulesWhere is it used?Typical service: Local visual alarm annunciation at the analyzer or controller location; Alarm signaling in Class I Division 2 classified areas using the Div 2 rated strobe.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0284 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0308 4-20mA output Board
What is the Teledyne Detcon 10-0308?The Teledyne Detcon 10-0308 is: 4-20mA output Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0308 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0309 Quad Wheatstone Bridge Input Board
What is the Teledyne Detcon 10-0309?The Teledyne Detcon 10-0309 is: Quad Wheatstone Bridge Input Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0309 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0321 19″ Rack Position Expansion Plate (Adds Up To 6 Option Positions)
What is the Teledyne Detcon 10-0321?The Teledyne Detcon 10-0321 is: 19" Rack Position Expansion Plate (Adds Up To 6 Option Positions). Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0321 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0332 Auxiliary Standard Alarm Relay Board
What is the Teledyne Detcon 10-0332?The Teledyne Detcon 10-0332 is: Auxiliary Standard Alarm Relay Board. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0332 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0337 100 dB Piezo Audible Alarm (option for 7200 Plus / ViewSmart 200 series controllers)
What is the Teledyne Detcon 10-0337?The Teledyne Detcon 10-0337 is: 100 dB Piezo Audible Alarm (option for 7200 Plus / ViewSmart 200 series controllers). Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0337 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0367 100-240VAC Universal Input 600 Watt 24VDC Power Supply (27.0 Amps)
What is the Teledyne Detcon 10-0367?The Teledyne Detcon 10-0367 is: 100-240VAC Universal Input 600 Watt 24VDC Power Supply (27.0 Amps). Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0367 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0368 RS485 Isolated Expansion Board
What is the Teledyne Detcon 10-0368?The Teledyne Detcon 10-0368 is: RS485 Isolated Expansion Board. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0368 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0628 CPU/Display Board
What is the Teledyne Detcon 10-0628?The Teledyne Detcon 10-0628 is: CPU/Display Board. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0628 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0631 Main I/O 3U Board
What is the Teledyne Detcon 10-0631?The Teledyne Detcon 10-0631 is: Main I/O 3U Board. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0631 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0638 Analog Input Option Board
What is the Teledyne Detcon 10-0638?The Teledyne Detcon 10-0638 is: Analog Input Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0638 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0639 Analog Output Option Board
What is the Teledyne Detcon 10-0639?The Teledyne Detcon 10-0639 is: Analog Output Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0639 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0640 Programmable Relay Option Board
What is the Teledyne Detcon 10-0640?The Teledyne Detcon 10-0640 is: Programmable Relay Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0640 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0641 Discrete Relay Option Board
What is the Teledyne Detcon 10-0641?The Teledyne Detcon 10-0641 is: Discrete Relay Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0641 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-1906 Dual light/Piezo
What is the Teledyne Detcon 1000-1906?The Teledyne Detcon 1000-1906 is: Dual light/Piezo. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-1906 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-2259 50W AC to DC Power Supply – Not Available on Compact or NEMA7
What is the Teledyne Detcon 1000-2259?The Teledyne Detcon 1000-2259 is: 50W AC to DC Power Supply - Not Available on Compact or NEMA7. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-2259 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-2373 120W AC to DC Power Supply – Not Available on Compact or NEMA7
What is the Teledyne Detcon 1000-2373?The Teledyne Detcon 1000-2373 is: 120W AC to DC Power Supply - Not Available on Compact or NEMA7. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-2373 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-2810 GP Red Strobe Local
What is the Teledyne Detcon 1000-2810?The Teledyne Detcon 1000-2810 is: GP Red Strobe Local. Local visual alarm devices offered with Teledyne Detcon gas detection controllers and Model 1000 series analyzer systems. The group covers red alarm strobes in general purpose and Class I Division 2 versions for local alarm annunciation at the monitored equipment. Detcon also documents relay-based alarm signaling through its controller and remote alarm module products, which these strobes connect to.About the Teledyne Detcon Alarm Stations & Signals lineRed strobe signals in general purpose (GP) and Division 2 rated versionsOffered as local alarm options and spares for Detcon Model 1000 series analyzer and controller packagesDriven by alarm relay outputs of Detcon controllers and alarm modulesWhere is it used?Typical service: Local visual alarm annunciation at the analyzer or controller location; Alarm signaling in Class I Division 2 classified areas using the Div 2 rated strobe.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-2810 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 275-556160-432 Power LED Indicator
What is the Teledyne Detcon 275-556160-432?The Teledyne Detcon 275-556160-432 is: Power LED Indicator. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 275-556160-432 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2A200-050 Alum 1/2″ NPT/ cable 9.4 to 14.0 mm outer dia.
What is the Teledyne Detcon 301-A2A200-050?The Teledyne Detcon 301-A2A200-050 is: Alum 1/2" NPT/ cable 9.4 to 14.0 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2A200-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2A200-075 Alum 3/4″ NPT/ cable 9.4 to 14.0 mm outer dia.
What is the Teledyne Detcon 301-A2A200-075?The Teledyne Detcon 301-A2A200-075 is: Alum 3/4" NPT/ cable 9.4 to 14.0 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2A200-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2A200-M20 Alum M20/ cable 9.4 to 14.0 mm outer dia.
What is the Teledyne Detcon 301-A2A200-M20?The Teledyne Detcon 301-A2A200-M20 is: Alum M20/ cable 9.4 to 14.0 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2A200-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2A20S-050 Alum 1/2″ NPT/ cable 7.2 to 11.7 mm outer dia.
What is the Teledyne Detcon 301-A2A20S-050?The Teledyne Detcon 301-A2A20S-050 is: Alum 1/2" NPT/ cable 7.2 to 11.7 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2A20S-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2A20S-075 Alum 3/4″ NPT/ cable 7.2 to 11.7 mm outer dia.
What is the Teledyne Detcon 301-A2A20S-075?The Teledyne Detcon 301-A2A20S-075 is: Alum 3/4" NPT/ cable 7.2 to 11.7 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2A20S-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification.