Gas and Flame Detection Systems
Showing 316–360 of 884 results
-

Oldham Simtronics SG50-F-IR3-H2-AS15 Triple IR (IR3) SG50-F for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-AS15?The Oldham Simtronics SG50-F-IR3-H2-AS15 is: Triple IR (IR3) SG50-F for Energy Transition Fires - e.g. Hydrogen. Complied with NFPA 33, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS15 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-AS20 Triple IR (IR3) SG50-F for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-AS20?The Oldham Simtronics SG50-F-IR3-H2-AS20 is: Triple IR (IR3) SG50-F for Energy Transition Fires - e.g. Hydrogen. 4-20mA / RS485 outputs. 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS20 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-AS21 Triple IR (IR3) SG50-F for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-AS21?The Oldham Simtronics SG50-F-IR3-H2-AS21 is: Triple IR (IR3) SG50-F for Energy Transition Fires - e.g. Hydrogen, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS21 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-AS23 Xtend Triple IR (IR3) SG50-F for Energy Transition Fires
What is the Oldham Simtronics SG50-F-IR3-H2-AS23?The Oldham Simtronics SG50-F-IR3-H2-AS23 is: Xtend Triple IR (IR3) SG50-F for Energy Transition Fires - HC & Hydrogen, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS23 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-AS25 Triple IR (IR3) SG50-F for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-AS25?The Oldham Simtronics SG50-F-IR3-H2-AS25 is: Triple IR (IR3) SG50-F for Energy Transition Fires - e.g. Hydrogen. Complied with NFPA 33, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS25 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS10 Triple IR (IR3) for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS10?The Oldham Simtronics SG50-F-IR3-H2-V-AS10 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hydrogen, with Near IR HD camera, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS10 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS11 Triple IR (IR3) for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS11?The Oldham Simtronics SG50-F-IR3-H2-V-AS11 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hydrogen, with Near IR HD camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS11 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS12 Triple IR (IR3) for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS12?The Oldham Simtronics SG50-F-IR3-H2-V-AS12 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hydrogen, with color camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS12 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS13 Xtend Triple IR (IR3) SG50-F for Energy Transition Fires
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS13?The Oldham Simtronics SG50-F-IR3-H2-V-AS13 is: Xtend Triple IR (IR3) SG50-F for Energy Transition Fires - HC & Hydrogen, with Near IR HD camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS13 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS15 Triple IR (IR3) for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS15?The Oldham Simtronics SG50-F-IR3-H2-V-AS15 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hydrogen, with Near IR HD camera. Complied with NFPA 33, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS15 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS20 Triple IR (IR3) for Energy Transition Fires – e.g. Hhydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS20?The Oldham Simtronics SG50-F-IR3-H2-V-AS20 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hhydrogen, with Near IR HD camera, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS20 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS21 Triple IR (IR3) for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS21?The Oldham Simtronics SG50-F-IR3-H2-V-AS21 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hydrogen, with Near IR HD camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS21 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS22 Triple IR (IR3) for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS22?The Oldham Simtronics SG50-F-IR3-H2-V-AS22 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hydrogen, with color camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS22 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS23 Xtend Triple IR (IR3) SG50-F for Energy Transition Fires
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS23?The Oldham Simtronics SG50-F-IR3-H2-V-AS23 is: Xtend Triple IR (IR3) SG50-F for Energy Transition Fires - HC & Hydrogen, with Near IR HD camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS23 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-V-AS25 Triple IR (IR3) for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-V-AS25?The Oldham Simtronics SG50-F-IR3-H2-V-AS25 is: Triple IR (IR3) for Energy Transition Fires - e.g. Hydrogen, with Near IR HD camera. Complied with NFPA 33, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-V-AS25 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS10 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, M25
What is the Oldham Simtronics SG50-F-IR3-V-AS10?The Oldham Simtronics SG50-F-IR3-V-AS10 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS10 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS11 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, HART
What is the Oldham Simtronics SG50-F-IR3-V-AS11?The Oldham Simtronics SG50-F-IR3-V-AS11 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS11 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS12 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with Near IR HD camera
What is the Oldham Simtronics SG50-F-IR3-V-AS12?The Oldham Simtronics SG50-F-IR3-V-AS12 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with Near IR HD camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS12 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS13 Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may
What is the Oldham Simtronics SG50-F-IR3-V-AS13?The Oldham Simtronics SG50-F-IR3-V-AS13 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may be present, with color camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS13 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS14 Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may
What is the Oldham Simtronics SG50-F-IR3-V-AS14?The Oldham Simtronics SG50-F-IR3-V-AS14 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may be present, with Near Ir camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS14 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS15 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera
What is the Oldham Simtronics SG50-F-IR3-V-AS15?The Oldham Simtronics SG50-F-IR3-V-AS15 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera. Complied with NFPA 33, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS15 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS20 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, 3/4NPT
What is the Oldham Simtronics SG50-F-IR3-V-AS20?The Oldham Simtronics SG50-F-IR3-V-AS20 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS20 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS21 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, HART
What is the Oldham Simtronics SG50-F-IR3-V-AS21?The Oldham Simtronics SG50-F-IR3-V-AS21 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS21 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS22 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with Near IR HD camera
What is the Oldham Simtronics SG50-F-IR3-V-AS22?The Oldham Simtronics SG50-F-IR3-V-AS22 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with Near IR HD camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS22 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS23 Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may
What is the Oldham Simtronics SG50-F-IR3-V-AS23?The Oldham Simtronics SG50-F-IR3-V-AS23 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may be present, with color camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS23 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS24 Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may
What is the Oldham Simtronics SG50-F-IR3-V-AS24?The Oldham Simtronics SG50-F-IR3-V-AS24 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire where exhaust gases may be present, with Near Ir camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS24 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-V-AS25 Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera
What is the Oldham Simtronics SG50-F-IR3-V-AS25?The Oldham Simtronics SG50-F-IR3-V-AS25 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire, with color camera, Complied with NFPA 33, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-V-AS25 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-AS10 UV-IR SG50-F, for non-Hydrocarbon Fire, 3/4NPT
What is the Oldham Simtronics SG50-F-UVIR-AS10?The Oldham Simtronics SG50-F-UVIR-AS10 is: UV-IR SG50-F, for non-Hydrocarbon Fire, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-AS10 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-AS11 UV-IR SG50-F, for non-Hydrocarbon Fire, HART, SIL2, M25
What is the Oldham Simtronics SG50-F-UVIR-AS11?The Oldham Simtronics SG50-F-UVIR-AS11 is: UV-IR SG50-F, for non-Hydrocarbon Fire, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-AS11 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-AS15 UV-IR SG50-F, for non-Hydrocarbon Fire. Complied with NFPA 33, HART
What is the Oldham Simtronics SG50-F-UVIR-AS15?The Oldham Simtronics SG50-F-UVIR-AS15 is: UV-IR SG50-F, for non-Hydrocarbon Fire. Complied with NFPA 33, HART , SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-AS15 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-AS20 UV-IR SG50-F, for non-Hydrocarbon Fire, 3/4NPT
What is the Oldham Simtronics SG50-F-UVIR-AS20?The Oldham Simtronics SG50-F-UVIR-AS20 is: UV-IR SG50-F, for non-Hydrocarbon Fire, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-AS20 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-AS21 UV-IR SG50-F, for non-Hydrocarbon Fire, HART, SIL2. 3/4NPT
What is the Oldham Simtronics SG50-F-UVIR-AS21?The Oldham Simtronics SG50-F-UVIR-AS21 is: UV-IR SG50-F, for non-Hydrocarbon Fire, HART, SIL2. 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-AS21 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-AS25 UV-IR SG50-F, for non-Hydrocarbon Fire. complied with NFPA 33, HART
What is the Oldham Simtronics SG50-F-UVIR-AS25?The Oldham Simtronics SG50-F-UVIR-AS25 is: UV-IR SG50-F, for non-Hydrocarbon Fire. complied with NFPA 33, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-AS25 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-AS10 UV-IR SG50-F, for Hydrocarbon Fire, M25
What is the Oldham Simtronics SG50-F-UVIR-F-AS10?The Oldham Simtronics SG50-F-UVIR-F-AS10 is: UV-IR SG50-F, for Hydrocarbon Fire, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-AS10 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-AS11 UV-IR SG50-F, for Hydrocarbon Fire, HART, SIL2, M25
What is the Oldham Simtronics SG50-F-UVIR-F-AS11?The Oldham Simtronics SG50-F-UVIR-F-AS11 is: UV-IR SG50-F, for Hydrocarbon Fire, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-AS11 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-AS15 UV-IR SG50-F, for Hydrocarbon Fire. Complied with NFPA 33, HART
What is the Oldham Simtronics SG50-F-UVIR-F-AS15?The Oldham Simtronics SG50-F-UVIR-F-AS15 is: UV-IR SG50-F, for Hydrocarbon Fire. Complied with NFPA 33, HART, SIL2. M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-AS15 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-AS20 UV-IR SG50-F, for Hydrocarbon Fire, 3/4NPT
What is the Oldham Simtronics SG50-F-UVIR-F-AS20?The Oldham Simtronics SG50-F-UVIR-F-AS20 is: UV-IR SG50-F, for Hydrocarbon Fire, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-AS20 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-AS21 UV-IR SG50-F, for Hydrocarbon Fire, HART, SIL2, 3/4NPT
What is the Oldham Simtronics SG50-F-UVIR-F-AS21?The Oldham Simtronics SG50-F-UVIR-F-AS21 is: UV-IR SG50-F, for Hydrocarbon Fire, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-AS21 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-AS25 UV-IR SG50-F, for Hydrocarbon Fire. Complied with NFPA 33, HART
What is the Oldham Simtronics SG50-F-UVIR-F-AS25?The Oldham Simtronics SG50-F-UVIR-F-AS25 is: UV-IR SG50-F, for Hydrocarbon Fire. Complied with NFPA 33, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-AS25 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-V-AS10 UV-IR SG50-F for Hydrocarbon Fire, with color camera, M25
What is the Oldham Simtronics SG50-F-UVIR-F-V-AS10?The Oldham Simtronics SG50-F-UVIR-F-V-AS10 is: UV-IR SG50-F for Hydrocarbon Fire, with color camera, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-V-AS10 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-V-AS11 UV-IR SG50-F for Hydrocarbon Fire, with color camera, HART, SIL2, M25
What is the Oldham Simtronics SG50-F-UVIR-F-V-AS11?The Oldham Simtronics SG50-F-UVIR-F-V-AS11 is: UV-IR SG50-F for Hydrocarbon Fire, with color camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-V-AS11 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-V-AS12 UV-IR SG50-F for Hydrocarbon Fire, with Near IR HD camera, HART
What is the Oldham Simtronics SG50-F-UVIR-F-V-AS12?The Oldham Simtronics SG50-F-UVIR-F-V-AS12 is: UV-IR SG50-F for Hydrocarbon Fire, with Near IR HD camera, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-V-AS12 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-V-AS15 UV-IR SG50-F for Hydrocarbon Fire, with color camera
What is the Oldham Simtronics SG50-F-UVIR-F-V-AS15?The Oldham Simtronics SG50-F-UVIR-F-V-AS15 is: UV-IR SG50-F for Hydrocarbon Fire, with color camera. Complied with NFPA 33, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-V-AS15 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-V-AS20 UV-IR SG50-F for Hydrocarbon Fire, with color camera, 3/4NPT
What is the Oldham Simtronics SG50-F-UVIR-F-V-AS20?The Oldham Simtronics SG50-F-UVIR-F-V-AS20 is: UV-IR SG50-F for Hydrocarbon Fire, with color camera, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-V-AS20 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-UVIR-F-V-AS21 UV-IR SG50-F for Hydrocarbon Fire, with color camera, HART, SIL2
What is the Oldham Simtronics SG50-F-UVIR-F-V-AS21?The Oldham Simtronics SG50-F-UVIR-F-V-AS21 is: UV-IR SG50-F for Hydrocarbon Fire, with color camera, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-UVIR-F-V-AS21 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue.