Oldham Simtronics OLCT 60 Fixed Gas Detector
The generation of high quality gas detectors designed for the detection of flammable, toxic gases or oxygen. The OLCT 60 Series is available in several versions: Explosion-proof XP or intrinsically safe IS sensor (combustible, toxic or oxygen versions). Remote or on-board sensor. The OLCT 60 can be remotely mounted, allowing detection in inaccessible locations or in Zone 0 or 20 in the case of the intrinsically safe (IS) version. The OLCT 60 is equipped with a local display and non-intrusive access to a safe menu. In hazardous areas, calibration can be done without the need of a hot work permit. The detector units are made of 316L stainless steel, and are rugged and resistant to corrosion. Certified IP66, the OLCT 60 is sealed against dust and splash water. The versatile instrument is the ideal solution for gas detection covering all industrial needs for a wide variety of applications. Features Pre-calibrated sensors Non-intrusive calibration Infrared Version Infrared sensor available An infrared sensor is already available for CO2, SF6 and refrigerant gases detection. Sensors technical specifications: XP Transmitter with XP sensor: Sensor Catalytic / Electrochemical / Semi conductor / Infrared Detected gases Explosive or toxic gases, O2, VOC and refrigerant Material Epoxy coated aluminium + 316 stainless steel sensor Pre-calibrated block Yes Power supply 16 to 30 V DC Average consumption 140 mA (catalytic) 80 mA (electrochemical) 120 mA (infrared sensor) Output signal 0 - 23 mA (4-20 mA reserved for measurement) Cable 3 active wires, shielded cable Max. cable loop resistance / length Catalytic: 32 Ω / 1 km at 1.5 mm2 (16 AWG) Electrochemical and XP IR: 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) Ingress protection IP 66 Approvals OLCT60D (with integrated cell): ATEX II 2 GD Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 60°C OLCT60D d (with remote cell): ATEX II 2 GD Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 70°C (for the detector) ATEX II 2 GD - Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 70°C (for the remote cell) Electromagnetic compatibility according to EN50270 Weight 2.1 kg Dimensions 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches Operating temperature -20°C to +60°C XP transmitter with IS sensor: Sensor Electrochemical Detected gases Toxic gases or O2 Material Epoxy coated aluminium + 316 stainless steel sensor Pre-calibrated block Yes Power supply 16 to 30 V DC Average consumption 80 mA Output signal 0 - 23 mA (4-20 mA reserved for measurement) Cable 3 active wires, shielded cable Max. cable loop resistance / length with OLDHAM controller 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) Ingress protection IP 66 Approvals OLCT60id (with integrated cell): ATEX II 2 GD - Ex db [ia Ga] ia IIC T4 Gb - Ex tb [ia Da] ia IIIC T135°C Db Ambient temperature: -20°C to 60°C OLCT60D id: (with remote cell) ATEX II 2 (1) GD - Ex db [ia Ga] IIC T4 Gb - Ex tb [ia Da] IIIC T135°C Db Ambient temperature: -20°C to 60°C (for the detector) ATEX II 1 GD - Ex ia IIC T4 Ga - Ex ia IIIC T135°C Da Ambient temperature: -20°C to 70°C (for the remote cell) Electromagnetic compatibility according to EN 50270 Weight 2.1 kg Dimensions 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches Operating temperature -20°C to +60°C Accessories: A Calibration cup (6331141) allows introduction of calibration gas on the sensor B Bypass adapter (6327910) allows measurement of samples C Splash guard system (6329004) protects the detector from liquid projections D Remote gas introduction head (6327911) allows introduction of gas without opening the detector E Removable protective filter (6335975) protects the sensor against projections and dust F Duct measurement kit (6793322) allows gas monitoring in a duct G Mounting bracket (6322420) allows the mounting of the detector to the ceiling H Protective cover (6123716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6793718) allows the replacement of another OLDHAM detector without re-drilling J Wall mounted collecting cone (6331169) for use with lighter-than-air gases K Ceiling mount collecting cone (6331168) for use with lighter-than-air gases L Tool kit (6147877) Product Data Sheet -

Oldham Simtronics OLCT 80 Fixed Gas Detector
Features Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Remote versions available XP, IS Integrated relays Direct link, 4-20 mA, loop and isolated sensor mode Unique advantages providing the solution you need Design advantages Pre-calibrated sensors for detection of: combustible gases: LEL catalytic and IR toxic gases oxygen Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Inputs Series 80 sensors have up to 9 glands dedicated to cable wiring Design advantages: The minimum configuration includes: 1 electrical input dedicated to a sensor. two 4-20 mA or binary inputs. This configuration allows any other sensor from the network to be recognized (e.g temperature sensor, emergency stop, flame detector, smoke detector). Outputs 4/20 mA with smart signal processing analog signal 4-20 mA data signals between 0 and 4 - 20 and 25mA The transmitted signal, between 0 and 3.2 mA and above 20 mA, can be processed to interpret and identify a wide range of trouble parameters such as: line faults, sensor faults, embedded electronics faults, ambiguity resolution, inhibition of calibration, maintenance call (initial drift or drift over time). RS485 (1200 bauds, 38kb Modbus ASCII for MX 62). The RS485 link gives access to : - sensor measurement - status and default - internal relay management Relays The relays are 2A / 250 VAC type with potential free SPDT contacts. Two types of relays: 2 gas alarm relays or supplementary inputs 1 fault relay The relays are actuated either directly by the sensor electronics or supplementary inputs, or from the MX62 central unit or the control system to which the sensor is connected. The relays can be in safety mode or not, triggered on increasing or decreasing alarms, manually* or automatically acknowledged. * By remote control, by pressing an external pushbutton connected to the dedicated binary input, by acknowledging on the MX 62 unit or the control system to which the sensor is connected. Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Technical advantages Stand-alone central unit For relay control, the OLCT 80 can operate as a standalone unit: an indisputable advantage in a classified explosion risk zone. Flexibility of connection modes OLCT 80 sensors can be connected either: in loop (opto-isolated - up to 16 sensors), 4-20 mA, under direct power and operate as a central unit. Operation traceability The operator can check records locally for the most recent time-date stamped events. Communication Remote dialogue with the sensor using IR remote control. Measurement power supply redundancy Independent ports allow a redundant connection to the measurement unit. Low power requirements The leading edge technology used in the OLCT80 transmitter makes it very energy efficient. This major advantage means that more sensors can be connected, with smaller wire cross-sections and over greater distances. Logistic advantages Loop arrangement The transmitter is perfectly adapted to mounting and connection to the digital fieldbus loop of the MX 62 unit. Supporting 1 to 3 digital addresses: the sensor block (detection element), the two 4-20 mA auxiliary inputs. Certification The OLCT80 Series is certified to the specifications required by standards EN 50054, 45544 and 50104 (environmental standards, explosive and toxic gases and oxygen) and to the specifications of standards EN 50270, EN 6052 (electromagnetic compatibility, ingress protection). OLCT 80 uses digital logic and software technologies. The sensors are protected and in compliance with the specifications of standard EN 51271: analog and digital values track each other homogeneity of digital resolution and response time with the specifications required internal self-diagnostics Configuration Options Stand Alone Version Standard Version Stand Alone Version Specifications Type Transmitter-sensor Detected gases Explosive, toxic and oxygen Detection principles Catalytic, Electrochemical, IR, Semiconductor Sensor block Pre-calibrated Device Aluminium enclosure and stainless steel 316Lfor sensor housing Visualisation 4-digit LCD display for measurement and one alphanumeric line for texts, Pictograms - backlighting 4 indicator lamps : one green : "OperationOK", one yellow : "Fault", red : "Alarm 1" and "Alarm 2" Power supply From 16 to 28 VDC at transmitter entry Maximum power with digital link - 0.2 W (electrochemical cell) - 1.3 W ( catalytic / SM ) with I output at 25 mA - 0.9 W (electrochemical cell) - 2 W ( catalytic / SM ) with I output at 25 mA and relays activated - 2.4 W (electrochemical cell) - 3.5 W ( catalytic / SM ) Power supply to sensor terminals Two independent inputs : 16 to 28 VDC (catalytic / IR / SM cells) 12 to 28 VDC (electrochemical cell) Inputs Two analog inputs 4-20 mA (load resistance 120 Ω, can be used as binary) Signal outputs Logic (relay contacts) Relay Analog Standardised 4-20 mA output Digital Two independent opto-isolated RS 485 ports Signal faults I < 0.5 mA Alarms 2 programmable thresholds per channel Relays Type SPDT Number 3 Contact RCT changer-over Breaking capacity 2A / 250 VAC / 30 VDC Wiring / connection Basic version, 6 inputs : 4 M20 and 2 M25 On request : 3 additional, 2 M20 and 1 M25 Load resistance on the 4-20 mA 500 Ω Loop resistance Under central unit 21 VDC: 128 ohms ( electrochemical cell ) - 32 Ω ( catalytic / SM ) - 16 Ω (IR) Protection number IP 66 Operating temperatures - 20 °C to + 60 °C ( electronics, see table for detection cells ) Dimensions See drawings Weight OLCT 80 : 3,5 kg, OLCT80 version IR : 5,3 kg Accessories A Infrared remote control B Tool kit C Bypass adapter D Cover key E Calibration cup F Remote gas introduction device G Gas collector H Splash guard Homologations Certification Atex OLCT 80 d OLCT 80 id ATEX II 2GD ATEX II 2GD Ex d IIC T6...T5 Gb Ex d ia IIC T4 Gb Ex tb IIIC T85°C...T100°C Db Ex tb ia IIIC T135°C Db INERIS 03ATEX0240X INERIS 03ATEX0240X Chine OLCT 80 d OLCT 80 id GYJ17.1201X - Ex d IIC T6/T5 Gb GYJ17.1202X - Ex d ia IIC T4 Gb Electromagnetic compatibility Complies with EN 50270 Product Data Sheet -

Oldham Simtronics OLCT10 Toxic Gas Detector
Designed for commercial applications, OLCT 10 detector perfectly suit the protection of equipment and personnel in presence of combustion and exhaust gases or refrigerants (freons) in ambient air. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Electrochemical and semiconductor sensors 4-20 mA output signal Dust and humidity resistant (IP65) Fast and accurate response Up to 5 detectors on same line (CO, NO, NO2) Applications: Cold rooms Car parks Wiring of 1 OLCT 10 detector Wiring in parallel of 2 OLCT 10 detecting same gas (CO, NO or NO2) Wiring of 1 OLCT 10 SC (with a semi-conductor cell) Dimensions: Technical features: Electrochemical sensor Semiconductor sensor Range CO (0-300 ppm), NO (0-100 ppm), NO2 (0-30 ppm) R134a, R404a, R22, R410a etc. Signal output Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Settings Without opening the enclosure by means of 2 potentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Power Supply 15 to 30 Vdc (nominal 24 Vdc) 15 to 30 Vdc (nominal 24 Vdc) Consumption 30 mA max. 100 mA max. Cabling 2-wire, shielded, core size 0.9mm2 2 cable gland M16 (outer 4 to 8 mm) 3-wire, shielded, core size 0.9mm2 1 cable gland M16 (outer 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP rating IP65 IP65 Expected Lifespan 24 to 48 month, depending gas to detect > 24 months Operating temperature -20 to +55°C -20 to +55°C Operating humidity 15% HR to 90% HR 20% HR to 90% HR Pressure range 1 bar ± 10 % 1 bar ± 10 % Response Time NO2: T90 < 60s, NO : T90 < 120 CO : T50 < 15s, Fréon R134A : T50 < 30s Certification Electromagnetic compatibility according to EN 50270:2015 (type2) Complies with EN 14624 for freon Product Data Sheet -

Oldham Simtronics OPGD-794079 USB/RS485 Harness Converter Kit
What is the Oldham Simtronics OPGD-794079?The Oldham Simtronics OPGD-794079 is: USB/RS485 Harness Converter Kit. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-794079 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-799225 Pole Mount (U-Bolt 5 inch)
What is the Oldham Simtronics OPGD-799225?The Oldham Simtronics OPGD-799225 is: Pole Mount (U-Bolt 5 inch). The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-799225 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888257 Extended Commissioning Kit – includes universal connection harness
What is the Oldham Simtronics OPGD-888257?The Oldham Simtronics OPGD-888257 is: Extended Commissioning Kit - includes universal connection harness for Modbus® / HART® communication, check filters (Methane, Propane and Ethylene). The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888257 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-1 Function Check Filter Warning Level – Propane Calibration
What is the Oldham Simtronics OPGD-888260-1?The Oldham Simtronics OPGD-888260-1 is: Function Check Filter Warning Level - Propane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-1 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-2 Function Check Filter Alarm Level – Propane Calibration
What is the Oldham Simtronics OPGD-888260-2?The Oldham Simtronics OPGD-888260-2 is: Function Check Filter Alarm Level - Propane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-2 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-3 Function Check Filter Warning Level – Methane Calibration
What is the Oldham Simtronics OPGD-888260-3?The Oldham Simtronics OPGD-888260-3 is: Function Check Filter Warning Level - Methane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-3 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-4 Function Check Filter Alarm Level – Methane Calibration
What is the Oldham Simtronics OPGD-888260-4?The Oldham Simtronics OPGD-888260-4 is: Function Check Filter Alarm Level - Methane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-4 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-5 Function Check Filter Warning Level – Ethylene Calibration
What is the Oldham Simtronics OPGD-888260-5?The Oldham Simtronics OPGD-888260-5 is: Function Check Filter Warning Level - Ethylene Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-5 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-6 Function Check Filter Alarm Level – Ethylene Calibration
What is the Oldham Simtronics OPGD-888260-6?The Oldham Simtronics OPGD-888260-6 is: Function Check Filter Alarm Level - Ethylene Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-6 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888263 Sunshade, Stainless Steel
What is the Oldham Simtronics OPGD-888263?The Oldham Simtronics OPGD-888263 is: Sunshade, Stainless Steel. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and this one is the stainless steel build.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888263 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888270 Tilt Mount (Stainless steel)
What is the Oldham Simtronics OPGD-888270?The Oldham Simtronics OPGD-888270 is: Tilt Mount (Stainless steel). The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and this one is the stainless steel build.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888270 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-C-111 Quasar 901, 7-20 m, ATEX, M25
What is the Oldham Simtronics OPGD-901-C-111?The Oldham Simtronics OPGD-901-C-111 is: Quasar 901, 7-20 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-C-111 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-C-112 Quasar 901, 7-20 m, ATEX, ¾ NPT
What is the Oldham Simtronics OPGD-901-C-112?The Oldham Simtronics OPGD-901-C-112 is: Quasar 901, 7-20 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-C-112 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-F-111 Quasar 901, 7-20 m, FM, M25
What is the Oldham Simtronics OPGD-901-F-111?The Oldham Simtronics OPGD-901-F-111 is: Quasar 901, 7-20 m, FM, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-F-111 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-F-112 Quasar 901, 7-20 m, FM, ¾ NPT
What is the Oldham Simtronics OPGD-901-F-112?The Oldham Simtronics OPGD-901-F-112 is: Quasar 901, 7-20 m, FM, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-F-112 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-C-211 Quasar 902, 15-40 m, ATEX, M25
What is the Oldham Simtronics OPGD-902-C-211?The Oldham Simtronics OPGD-902-C-211 is: Quasar 902, 15-40 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-C-211 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-C-212 Quasar 902, 15-40 m, ATEX, ¾ NPT
What is the Oldham Simtronics OPGD-902-C-212?The Oldham Simtronics OPGD-902-C-212 is: Quasar 902, 15-40 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-C-212 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-F-211 Quasar 902, 15-40 m, FM, M25
What is the Oldham Simtronics OPGD-902-F-211?The Oldham Simtronics OPGD-902-F-211 is: Quasar 902, 15-40 m, FM, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-F-211 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-F-212 Quasar 902, 15-40 m, FM, ¾ NPT
What is the Oldham Simtronics OPGD-902-F-212?The Oldham Simtronics OPGD-902-F-212 is: Quasar 902, 15-40 m, FM, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-F-212 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-C-311 Quasar 903, 35-100 m, ATEX, M25
What is the Oldham Simtronics OPGD-903-C-311?The Oldham Simtronics OPGD-903-C-311 is: Quasar 903, 35-100 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-C-311 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-C-312 Quasar 903, 35-100 m, ATEX, ¾ NPT
What is the Oldham Simtronics OPGD-903-C-312?The Oldham Simtronics OPGD-903-C-312 is: Quasar 903, 35-100 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-C-312 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-F-311 Quasar 903, 35-100 m, FM, M25
What is the Oldham Simtronics OPGD-903-F-311?The Oldham Simtronics OPGD-903-F-311 is: Quasar 903, 35-100 m, FM, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-F-311 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-F-312 Quasar 903, 35-100 m, FM, ¾ NPT
What is the Oldham Simtronics OPGD-903-F-312?The Oldham Simtronics OPGD-903-F-312 is: Quasar 903, 35-100 m, FM, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-F-312 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-904-C-411 Quasar 904, 80-200 m, ATEX, M25
What is the Oldham Simtronics OPGD-904-C-411?The Oldham Simtronics OPGD-904-C-411 is: Quasar 904, 80-200 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-904-C-411 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-904-C-412 Quasar 904, 80-200 m, ATEX, ¾ NPT
What is the Oldham Simtronics OPGD-904-C-412?The Oldham Simtronics OPGD-904-C-412 is: Quasar 904, 80-200 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-904-C-412 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-904-F-411 Quasar 904, 80-200 m, FM, M25
What is the Oldham Simtronics OPGD-904-F-411?The Oldham Simtronics OPGD-904-F-411 is: Quasar 904, 80-200 m, FM, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-904-F-411 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-904-F-412 Quasar 904, 80-200 m, FM, ¾ NPT
What is the Oldham Simtronics OPGD-904-F-412?The Oldham Simtronics OPGD-904-F-412 is: Quasar 904, 80-200 m, FM, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-904-F-412 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics R-5000AL-2 Display Module, Aluminum Enclosure (Use only with 4-20mA Source units)
What is the Oldham Simtronics R-5000AL-2?The Oldham Simtronics R-5000AL-2 is: Display Module, Aluminum Enclosure (Use only with 4-20mA Source units). The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the aluminium build, with the 4-20 mA current source output stage.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics R-5000AL-2 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics R-5000ALR-2 Display Module with Relays, Aluminum Enclosure
What is the Oldham Simtronics R-5000ALR-2?The Oldham Simtronics R-5000ALR-2 is: Display Module with Relays, Aluminum Enclosure (Use only with 4-20mA Source units). The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the aluminium build, with the 4-20 mA current source output stage.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics R-5000ALR-2 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics R-5000SS-2 Display Module, Stainless Steel Enclosure
What is the Oldham Simtronics R-5000SS-2?The Oldham Simtronics R-5000SS-2 is: Display Module, Stainless Steel Enclosure (Use only with 4-20mA Source units). The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the stainless steel build, with the 4-20 mA current source output stage.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics R-5000SS-2 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics R-5000SSR-2 Display Module with Relays, Stainless Steel Enclosure
What is the Oldham Simtronics R-5000SSR-2?The Oldham Simtronics R-5000SSR-2 is: Display Module with Relays, Stainless Steel Enclosure (Use only with 4-20mA Source units). The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the stainless steel build, with the 4-20 mA current source output stage.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics R-5000SSR-2 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS10 Triple IR (IR3) SG50-F, for Hydrocarbon Fire, M25
What is the Oldham Simtronics SG50-F-IR3-AS10?The Oldham Simtronics SG50-F-IR3-AS10 is: Triple IR (IR3) SG50-F, for Hydrocarbon Fire, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS10 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS11 Triple IR (IR3) SG50-F, for Hydrocarbon Fire, HART, SIL2, M25
What is the Oldham Simtronics SG50-F-IR3-AS11?The Oldham Simtronics SG50-F-IR3-AS11 is: Triple IR (IR3) SG50-F, for Hydrocarbon Fire, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS11 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS13 Triple IR (IR3) SG50-F, for Hydrocarbon Fire where exhaust gases may
What is the Oldham Simtronics SG50-F-IR3-AS13?The Oldham Simtronics SG50-F-IR3-AS13 is: Triple IR (IR3) SG50-F, for Hydrocarbon Fire where exhaust gases may be present, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS13 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS15 Triple IR (IR3) SG50-F for Hydrocarbon Fire. Complied with NFPA 33
What is the Oldham Simtronics SG50-F-IR3-AS15?The Oldham Simtronics SG50-F-IR3-AS15 is: Triple IR (IR3) SG50-F for Hydrocarbon Fire. Complied with NFPA 33, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS15 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS20 Triple IR (IR3) SG50-F, for Hydrocarbon Fire, 3/4NPT
What is the Oldham Simtronics SG50-F-IR3-AS20?The Oldham Simtronics SG50-F-IR3-AS20 is: Triple IR (IR3) SG50-F, for Hydrocarbon Fire, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS20 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS21 Triple IR (IR3) SG50-F, for Hydrocarbon Fire, HART, SIL2, 3/4NPT
What is the Oldham Simtronics SG50-F-IR3-AS21?The Oldham Simtronics SG50-F-IR3-AS21 is: Triple IR (IR3) SG50-F, for Hydrocarbon Fire, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS21 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS23 Triple IR (IR3) SG50-F, for Hydrocarbon Fire where exhaust gases may
What is the Oldham Simtronics SG50-F-IR3-AS23?The Oldham Simtronics SG50-F-IR3-AS23 is: Triple IR (IR3) SG50-F, for Hydrocarbon Fire where exhaust gases may be present, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS23 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-AS25 Triple IR (IR3) SG50-F, for Hydrocarbon Fire. Complied with NFPA 33
What is the Oldham Simtronics SG50-F-IR3-AS25?The Oldham Simtronics SG50-F-IR3-AS25 is: Triple IR (IR3) SG50-F, for Hydrocarbon Fire. Complied with NFPA 33, HART, SIL2, 3/4NPT. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-AS25 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-AS10 Triple IR (IR3) SG50-F for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-AS10?The Oldham Simtronics SG50-F-IR3-H2-AS10 is: Triple IR (IR3) SG50-F for Energy Transition Fires - e.g. Hydrogen. 4-20mA / RS485 outputs. M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS10 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-AS11 Triple IR (IR3) SG50-F for Energy Transition Fires – e.g. Hydrogen
What is the Oldham Simtronics SG50-F-IR3-H2-AS11?The Oldham Simtronics SG50-F-IR3-H2-AS11 is: Triple IR (IR3) SG50-F for Energy Transition Fires - e.g. Hydrogen, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS11 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue. -

Oldham Simtronics SG50-F-IR3-H2-AS13 Xtend Triple IR (IR3) SG50-F for Energy Transition Fires
What is the Oldham Simtronics SG50-F-IR3-H2-AS13?The Oldham Simtronics SG50-F-IR3-H2-AS13 is: Xtend Triple IR (IR3) SG50-F for Energy Transition Fires - HC & Hydrogen, HART, SIL2, M25. The Spyglass SG50-F family covers a wide variety of fire types in a stainless steel housing, and is offered in triple infrared (IR3) and ultraviolet with infrared (UV-IR) technologies, including versions for hydrogen and other alternate energy fuel fires. An on-board video option lets a fire be viewed in real time or reviewed after an incident without anyone being at the scene. An ultra fast detection mode is available for spark and NFPA 33 applications, and the family covers arcs and sparks in windmills, munitions, and hot engine exhaust such as helipads.What are the specifications of the Spyglass SG50-F Flame Detectors?Detection technologies: triple infrared (IR3) and ultraviolet with infrared (UV-IR), plus hydrogen fire versionsField of view: 90 degrees horizontal, 80 degrees verticalSG50-F-UV-IR detection time: 5 ms for a fast fire burst or explosion, 1 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 2 s at 15 to 30 mSG50-F-UV-IR-F detection time: 5 ms for a fast fire burst or explosion, 1.5 s for a 0.1 m2 n-heptane pan fire at 0 to 15 m, under 3 s at 15 to 30 mAdjustable time delay 0 to 30 seconds, with automatic and manual built-in testOperating voltage 24 V DC nominal (18 to 32 V DC); 120 mA standby, 180 mA maximum with all systems including the window heaterOutputs: 0-20 mA, HART, Modbus and 3 relaysCable entries: two conduit entries, 3/4 inch NPT or M25 x 1.5, one plugged with a certified stopperExplosion proof approvals: ATEX, UKCA, IECEx, PESO, INMETRO, FM and FMC; performance to ANSI FM 3260 and EN 54-10Functional safety: certified SIL 2 per IEC 61508What should you check before ordering?Response figures here are test results against a defined fire, not marketing rounding: a 0.1 m2 n-heptane pan fire, measured at two distance bands. That matters when comparing the two UV-IR variants, because the F version is consistently the slower of the pair on the same fire (1.5 s against 1 s at 0 to 15 m, and under 3 s against under 2 s at 15 to 30 m), while both hit 5 ms on a fast burst or explosion. The temperature ceiling also moves with the temperature class ordered: T5 approval runs to 75 C ambient while T4 runs to 85 C, so the class chosen on the order limits where the detector can be mounted.How do the part numbers differ?Part numbers separate the detection technology (UV-IR or IR3, with H2 versions for hydrogen), the presence of HART and SIL 2, NFPA 33 compliance, and the cable entry thread (M25 or 3/4 inch NPT), so two references that look alike can differ on approval scope rather than on the sensor.Where is it used?Typical service: Hydrocarbon fire detection in process and storage areas; Hydrogen and alternate energy fuel fires; Arc and spark detection, including windmills and NFPA 33 spray application areas; Munitions handling and storage; Helipads and other areas with hot engine exhaust; Incident review where the on-board video option is fitted.How do I order or get a quote?PE Energy supplies the Oldham Simtronics SG50-F-IR3-H2-AS13 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the Spyglass SG50-F flame detector line already in our catalogue.