Gas and Flame Detection Systems
Showing 451–495 of 884 results
-

Teledyne Detcon 301-A2A20S-M20 Alum M20/ cable 7.2 to 11.7 mm outer dia.
What is the Teledyne Detcon 301-A2A20S-M20?The Teledyne Detcon 301-A2A20S-M20 is: Alum M20/ cable 7.2 to 11.7 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the aluminum variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2A20S-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2B200-050 Brass 1/2″ NPT/ cable 9.4 to 14.0 mm outer dia. for non-H2S environment
What is the Teledyne Detcon 301-A2B200-050?The Teledyne Detcon 301-A2B200-050 is: Brass 1/2" NPT/ cable 9.4 to 14.0 mm outer dia. for non-H2S environment. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the brass variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2B200-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2B200-075 Brass 3/4″ NPT/ cable 9.4 to 14.0 mm outer dia. for non-H2S environment
What is the Teledyne Detcon 301-A2B200-075?The Teledyne Detcon 301-A2B200-075 is: Brass 3/4" NPT/ cable 9.4 to 14.0 mm outer dia. for non-H2S environment. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the brass variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2B200-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2B200-M20 Brass M20/ cable 9.4 to 14.0 mm outer dia. for non-H2S environment
What is the Teledyne Detcon 301-A2B200-M20?The Teledyne Detcon 301-A2B200-M20 is: Brass M20/ cable 9.4 to 14.0 mm outer dia. for non-H2S environment. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the brass variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2B200-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2B20S-050 Brass 1/2″ NPT/ cable 7.2 to 11.7 mm outer dia. for non-H2S environment
What is the Teledyne Detcon 301-A2B20S-050?The Teledyne Detcon 301-A2B20S-050 is: Brass 1/2" NPT/ cable 7.2 to 11.7 mm outer dia. for non-H2S environment. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the brass variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2B20S-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2B20S-075 Brass 3/4″ NPT/ cable 7.2 to 11.7 mm outer dia. for non-H2S environment
What is the Teledyne Detcon 301-A2B20S-075?The Teledyne Detcon 301-A2B20S-075 is: Brass 3/4" NPT/ cable 7.2 to 11.7 mm outer dia. for non-H2S environment. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the brass variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2B20S-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2B20S-M20 Brass M20/ cable 7.2 to 11.7 mm outer dia. for non-H2S environment
What is the Teledyne Detcon 301-A2B20S-M20?The Teledyne Detcon 301-A2B20S-M20 is: Brass M20/ cable 7.2 to 11.7 mm outer dia. for non-H2S environment. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the brass variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2B20S-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2S200-050 Stainless Steel 1/2″ NPT/ cable 9.4 to 14.0 mm outer dia.
What is the Teledyne Detcon 301-A2S200-050?The Teledyne Detcon 301-A2S200-050 is: Stainless Steel 1/2" NPT/ cable 9.4 to 14.0 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2S200-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2S200-075 Stainless Steel 3/4″ NPT/ cable 9.4 to 14.0 mm outer dia.
What is the Teledyne Detcon 301-A2S200-075?The Teledyne Detcon 301-A2S200-075 is: Stainless Steel 3/4" NPT/ cable 9.4 to 14.0 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2S200-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2S200-M20 Stainless Steel M20/ cable 9.4 to 14.0 mm outer dia.
What is the Teledyne Detcon 301-A2S200-M20?The Teledyne Detcon 301-A2S200-M20 is: Stainless Steel M20/ cable 9.4 to 14.0 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2S200-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2S20S-050 Stainless Steel 1/2″ NPT/ cable 7.2 to 11.7 mm outer dia.
What is the Teledyne Detcon 301-A2S20S-050?The Teledyne Detcon 301-A2S20S-050 is: Stainless Steel 1/2" NPT/ cable 7.2 to 11.7 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2S20S-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2S20S-075 Stainless Steel 3/4″ NPT/ cable 7.2 to 11.7 mm outer dia.
What is the Teledyne Detcon 301-A2S20S-075?The Teledyne Detcon 301-A2S20S-075 is: Stainless Steel 3/4" NPT/ cable 7.2 to 11.7 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2S20S-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A2S20S-M20 Stainless Steel M20/ cable 7.2 to 11.7 mm outer dia.
What is the Teledyne Detcon 301-A2S20S-M20?The Teledyne Detcon 301-A2S20S-M20 is: Stainless Steel M20/ cable 7.2 to 11.7 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A2S20S-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A3NP16-075 Nickel Plated 075NPT/ cable 4.0 to 8.4 mm outer dia.
What is the Teledyne Detcon 301-A3NP16-075?The Teledyne Detcon 301-A3NP16-075 is: Nickel Plated 075NPT/ cable 4.0 to 8.4 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A3NP16-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A3NP16-M20 Nickel Plated M20/ cable 4.0 to 8.4 mm outer dia.
What is the Teledyne Detcon 301-A3NP16-M20?The Teledyne Detcon 301-A3NP16-M20 is: Nickel Plated M20/ cable 4.0 to 8.4 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A3NP16-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A3SF16-075 Stainless Steel 3/4″ NPT/ cable 4.0 to 8.4 mm outer dia.
What is the Teledyne Detcon 301-A3SF16-075?The Teledyne Detcon 301-A3SF16-075 is: Stainless Steel 3/4" NPT/ cable 4.0 to 8.4 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A3SF16-075 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 301-A3SF16-M20 Stainless Steel M20/ cable 4.0 to 8.4 mm outer dia.
What is the Teledyne Detcon 301-A3SF16-M20?The Teledyne Detcon 301-A3SF16-M20 is: Stainless Steel M20/ cable 4.0 to 8.4 mm outer dia. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 301-A3SF16-M20 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 302-RSFCCO-05m Connector Dust Cap
What is the Teledyne Detcon 302-RSFCCO-05m?The Teledyne Detcon 302-RSFCCO-05m is: Connector Dust Cap. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.About the Teledyne Detcon Detcon Accessories (unassigned) lineCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 302-RSFCCO-05m on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 320-228120-300 3 amp circuit breaker
What is the Teledyne Detcon 320-228120-300?The Teledyne Detcon 320-228120-300 is: 3 amp circuit breaker. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 320-228120-300 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 320-228861-105 5 amp circuit breaker
What is the Teledyne Detcon 320-228861-105?The Teledyne Detcon 320-228861-105 is: 5 amp circuit breaker. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 320-228861-105 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 320-N45161-000 Reset Switch for N4X
What is the Teledyne Detcon 320-N45161-000?The Teledyne Detcon 320-N45161-000 is: Reset Switch for N4X. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 320-N45161-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 320-N75161-000 Reset Switch for N7X
What is the Teledyne Detcon 320-N75161-000?The Teledyne Detcon 320-N75161-000 is: Reset Switch for N7X. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 320-N75161-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 326-000000-000 Replaceable sintered stainless steel flame arrestor
What is the Teledyne Detcon 326-000000-000?The Teledyne Detcon 326-000000-000 is: Replaceable sintered stainless steel flame arrestor. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method. The Detcon Accessories (unassigned) group in the Detcon price book lists 100 orderable part numbers; this is the stainless steel variant.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 326-000000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 327-000000-000 Magnetic programming tool
What is the Teledyne Detcon 327-000000-000?The Teledyne Detcon 327-000000-000 is: Magnetic programming tool. The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 327-000000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 345-005160-100 Loop Powered LED Display replacement
What is the Teledyne Detcon 345-005160-100?The Teledyne Detcon 345-005160-100 is: Loop Powered LED Display replacement. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 345-005160-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 348-900000-000 1Lpm Rotameter with valve
What is the Teledyne Detcon 348-900000-000?The Teledyne Detcon 348-900000-000 is: 1Lpm Rotameter with valve. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 348-900000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 350-300000-000 0.5Lpm Rotameter with no valve
What is the Teledyne Detcon 350-300000-000?The Teledyne Detcon 350-300000-000 is: 0.5Lpm Rotameter with no valve. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 350-300000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 350-523081-02K Mass Flow Controller
What is the Teledyne Detcon 350-523081-02K?The Teledyne Detcon 350-523081-02K is: Mass Flow Controller. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 350-523081-02K on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 360-3S6PFP-ASM Flat Battery Pack
What is the Teledyne Detcon 360-3S6PFP-ASM?The Teledyne Detcon 360-3S6PFP-ASM is: Flat Battery Pack. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 360-3S6PFP-ASM on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 360-DLP075-024 Power supply for X08 N4X
What is the Teledyne Detcon 360-DLP075-024?The Teledyne Detcon 360-DLP075-024 is: Power supply for X08 N4X. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 360-DLP075-024 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 360-ML0100-024 PULS 24 VDC 4.2 A 100 W DIN-rail mount power supply (X40 / MX 40 controller spare)
What is the Teledyne Detcon 360-ML0100-024?The Teledyne Detcon 360-ML0100-024 is: PULS 24 VDC 4.2 A 100 W DIN-rail mount power supply (X40 / MX 40 controller spare); non-quarantined sibling DET-360-ML0100-024 carries the identical description in the same official Teledyne price list table. Splash guards, harsh environment sensor guards, duct mount kits, mounting plates, and DIN-rail mounting hardware for Teledyne Detcon fixed gas detection systems. These accessories serve the 700 series and Model 100 series sensors as well as SmartWireless and X40 controller installations, where radio transceivers and power supplies mount on DIN rail. The 700 series splash guard with integral calibration port is the accessory specified in the detector's performance certification testing.Key specificationsSensor splash guard with integral cal port (613-120000-700) for 700 series and Model 100 sensors; used in ANSI/UL 12.13.01 performance testing of the FP-700Harsh environment sensor guard (943-002273-000) for wind, dust, and spray exposure; Detcon notes it slows response time, particularly on heavy hydrocarbon gasesSensor duct mount kits for LEL, toxic (TP), and 700 series sensorsSensor mounting plate with sunshade for 2 to 3 inch pipe mountingCondensation prevention packet for junction boxes, replaced annuallyDIN-rail mount hardware for the RXT-320 wireless transceiver and 24 VDC power supplies used with X40 and MX 40 controllersWhere is it used?Typical service: Protecting installed sensors in wet, dusty, or high-wind outdoor locations; Duct mounting of gas sensors for ventilation and HVAC monitoring; DIN-rail and pipe mounting of detector system components in field enclosures.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 360-ML0100-024 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 360-TL5930-000 Battery, Lithium 3.6V ‘D’-size (Not rechargeable)
What is the Teledyne Detcon 360-TL5930-000?The Teledyne Detcon 360-TL5930-000 is: Battery, Lithium 3.6V 'D'-size (Not rechargeable). The CXT SmartWireless line packages a low power gas detection sensor and a 2.4 GHz wireless transceiver in a single explosion proof enclosure for hazardous area monitoring. Model CXT-DM sensors use plug-in, field replaceable electrochemical cells to detect a wide range of toxic gases and oxygen deficiency, while Model CXT-IR sensors use a plug-in NDIR infrared cell to detect combustible hydrocarbons from 0-100% LEL. Sensors communicate over Detcon's SmartWireless self-healing mesh network using direct sequence spread spectrum radio, with every device able to act as a router and repeater for the others. Units run on internal battery packs (disposable D cell or rechargeable lithium-ion) and are programmed non-intrusively with a handheld magnet, with a 4-digit LED display and fully scripted autocalibration prompts.About the Teledyne Detcon CXT SmartWireless lineSensor technologies: plug-in electrochemical cells (CXT-DM, toxic gases and O2 deficiency) and plug-in NDIR infrared cell (CXT-IR, combustible hydrocarbons 0-100% LEL)Measuring ranges: 0-1 ppm up to 0-10,000 ppm for toxic gases, 0-1% to 0-25% volume for oxygen (CXT-DM); 0-100% LEL and 0-100% volume (CXT-IR)Radio: IEEE 802.15.4 based transceiver, 2.40-2.48 GHz, 16 RF channels, DSSS spread spectrum, O-QPSK modulation, mesh and point-to-point topologiesOutdoor RF line of sight: 1.5 miles with standard antennaPower: internal battery packs, disposable 3.6V D cell pack (up to 6 months runtime) or lithium-ion rechargeable smart battery pack (4 months runtime); solar charging panel accessory for safe areasNEMA 4X ingress protection (CXT-DM); non-intrusive magnetic programming with 4-digit LED displaySerial polling via Modbus RTU supportedWhere is it used?Typical service: Oil and gas drilling rigs; Workover and pulling units; Oil and gas production sites; Turnarounds in refining and petrochemical plants.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 360-TL5930-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 370-010000-700 H2S, Hydrogen sulfide Plug-in Sensor for TP-700
What is the Teledyne Detcon 370-010000-700?The Teledyne Detcon 370-010000-700 is: H2S, Hydrogen sulfide Plug-in Sensor for TP-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-010000-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 370-090800-000 HBr, Hydrogen Bromide plug-in sensor for DM-500
What is the Teledyne Detcon 370-090800-000?The Teledyne Detcon 370-090800-000 is: HBr, Hydrogen Bromide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-090800-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-090900-000 HCl, Hydrogen Chloride plug-in sensor for DM-500
What is the Teledyne Detcon 370-090900-000?The Teledyne Detcon 370-090900-000 is: HCl, Hydrogen Chloride plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-090900-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-12EB00-000 C4H6, Butadiene plug-in sensor for DM-500
What is the Teledyne Detcon 370-12EB00-000?The Teledyne Detcon 370-12EB00-000 is: C4H6, Butadiene plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12EB00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-12ED00-000 C2H4, Ethylene plug-in sensor for DM-500
What is the Teledyne Detcon 370-12ED00-000?The Teledyne Detcon 370-12ED00-000 is: C2H4, Ethylene plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12ED00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-12EE00-000 CH3OH, Methanol plug-in sensor for DM-500
What is the Teledyne Detcon 370-12EE00-000?The Teledyne Detcon 370-12EE00-000 is: CH3OH, Methanol plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12EE00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-12EG00-000 C2H2, Acetylene plug-in detector assembly
What is the Teledyne Detcon 370-12EG00-000?The Teledyne Detcon 370-12EG00-000 is: C2H2, Acetylene plug-in detector assembly. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12EG00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 370-12EJ00-000 C2H4O, Ethylene Oxide plug-in sensor for DM-500
What is the Teledyne Detcon 370-12EJ00-000?The Teledyne Detcon 370-12EJ00-000 is: C2H4O, Ethylene Oxide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12EJ00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-12EK00-000 CH3SH, Methyl mercaptan plug-in sensor for DM-500
What is the Teledyne Detcon 370-12EK00-000?The Teledyne Detcon 370-12EK00-000 is: CH3SH, Methyl mercaptan plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12EK00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-12EO00-000 C2H5OH, Ethanol plug-in sensor for DM-500
What is the Teledyne Detcon 370-12EO00-000?The Teledyne Detcon 370-12EO00-000 is: C2H5OH, Ethanol plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12EO00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-12EP00-000 CH2O, Formaldehyde plug-in sensor for DM-500
What is the Teledyne Detcon 370-12EP00-000?The Teledyne Detcon 370-12EP00-000 is: CH2O, Formaldehyde plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-12EP00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-131300-000 HCN, Hydrogen Cyanide plug-in sensor for DM-500
What is the Teledyne Detcon 370-131300-000?The Teledyne Detcon 370-131300-000 is: HCN, Hydrogen Cyanide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-131300-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-191900-000 AsH3, Arsine plug-in sensor for DM-500
What is the Teledyne Detcon 370-191900-000?The Teledyne Detcon 370-191900-000 is: AsH3, Arsine plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-191900-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry.