Teledyne Detcon 370-192000-000 PH3, Phosphine plug-in sensor for DM-500
What is the Teledyne Detcon 370-192000-000?The Teledyne Detcon 370-192000-000 is: PH3, Phosphine plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-192000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-192100-000 B2H6, Diborane plug-in sensor for DM-500
What is the Teledyne Detcon 370-192100-000?The Teledyne Detcon 370-192100-000 is: B2H6, Diborane plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-192100-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-201600-000 Combustible gas field replaceable plug-in sensor
What is the Teledyne Detcon 370-201600-000?The Teledyne Detcon 370-201600-000 is: Combustible gas field replaceable plug-in sensor. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-201600-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 370-201600-700 Combustible Gas 0-100% LEL Plug-in Sensor for FP-700
What is the Teledyne Detcon 370-201600-700?The Teledyne Detcon 370-201600-700 is: Combustible Gas 0-100% LEL Plug-in Sensor for FP-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-100% lel range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-201600-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 370-242400-000 H2S, Hydrogen Sulfide plug-in sensor for DM-500
What is the Teledyne Detcon 370-242400-000?The Teledyne Detcon 370-242400-000 is: H2S, Hydrogen Sulfide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-242400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-24EZ00-000 C2H5SH, Ethyl mercaptan plug-in sensor for DM-500
What is the Teledyne Detcon 370-24EZ00-000?The Teledyne Detcon 370-24EZ00-000 is: C2H5SH, Ethyl mercaptan plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-24EZ00-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-272700-000 F2, Fluorine plug-in sensor for DM-500
What is the Teledyne Detcon 370-272700-000?The Teledyne Detcon 370-272700-000 is: F2, Fluorine plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-272700-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-287724-700 CO2, Carbon dioxide 10-100% Vol. Plug-in Sensor for Model
What is the Teledyne Detcon 370-287724-700?The Teledyne Detcon 370-287724-700 is: CO2, Carbon dioxide 10-100% Vol. Plug-in Sensor for Model 1000 Analyzer. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-100% vol. range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-287724-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 370-333300-000 HF, Hydrogen Fluoride plug-in sensor for DM-500
What is the Teledyne Detcon 370-333300-000?The Teledyne Detcon 370-333300-000 is: HF, Hydrogen Fluoride plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-333300-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-365878-700 CO2, Carbon dioxide 0-5% Vol. Plug-in Sensor for IR-700
What is the Teledyne Detcon 370-365878-700?The Teledyne Detcon 370-365878-700 is: CO2, Carbon dioxide 0-5% Vol. Plug-in Sensor for IR-700. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels. The Model 700 Replacement Sensors group in the Detcon price book lists 40 orderable part numbers; calibrated for the 0-5% vol. range.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-365878-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 370-3658CH-700 Combustible Hydrocarbon plug-in sensor for IR-700-CH
What is the Teledyne Detcon 370-3658CH-700?The Teledyne Detcon 370-3658CH-700 is: Combustible Hydrocarbon plug-in sensor for IR-700-CH. These are plug-in replacement sensor cells for the Teledyne Detcon 700 Series fixed gas detectors: electrochemical cells for the DM-700 toxic gas and oxygen sensors, MOS cells for the TP-700 hydrogen sulfide sensor, catalytic bead elements for the FP-700 combustible gas sensor, infrared elements for the IR-700, and photoionization cells for the PI-700. The intelligent plug-in cells are field replaceable, provide automatic recognition of gas type and range, and use oversized gold-plated connections that help prevent corrosion. Teledyne publishes per-gas sensor warranties for DM-700 cells ranging from 1.5 to 3 years depending on the target gas, with detection ranges from 0-1 ppm up to percent-volume levels.Key specificationsPlug-in, field-replaceable sensor cells; quick thread release sensor endcap requires only an Allen wrenchAutomatic recognition of gas type and range by the detector transmitterOversized gold-plated connections resist corrosion in harsh industrial environmentsElectrochemical (DM-700), MOS H2S (TP-700), catalytic LEL (FP-700), infrared CO2/hydrocarbon (IR-700) cell technologiesPer-gas warranties of 1.5 to 3 years for DM-700 electrochemical cells per the official gas tableDesert Climate (DC) H2S cells third-party tested to the ISA 92.00.01-2010 standardToxic gas ranges from 0-1 ppm up to percent-volume; oxygen deficiency up to 0-25 percent volumeWhere is it used?Typical service: Scheduled sensor cell replacement on installed 700 Series detectors; Restoring calibration-ready service in oil and gas, refining, and chemical plants; Maintenance stock for wastewater and utility gas detection systems.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-3658CH-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the DM-700 toxic gas detector we carry. -

Teledyne Detcon 370-393900-000 O3, Ozone plug-in sensor for DM-500
What is the Teledyne Detcon 370-393900-000?The Teledyne Detcon 370-393900-000 is: O3, Ozone plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-393900-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-444400-000 CO, Carbon Monoxide plug-in sensor for DM-500
What is the Teledyne Detcon 370-444400-000?The Teledyne Detcon 370-444400-000 is: CO, Carbon Monoxide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-444400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-505000-000 NH3, Ammonia plug-in sensor for DM-500
What is the Teledyne Detcon 370-505000-000?The Teledyne Detcon 370-505000-000 is: NH3, Ammonia plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-505000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-555500-000 SO2, Sulfur Dioxide plug-in sensor for DM-500
What is the Teledyne Detcon 370-555500-000?The Teledyne Detcon 370-555500-000 is: SO2, Sulfur Dioxide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-555500-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-646400-000 NO2, Nitrogen Dioxide plug-in sensor for DM-500
What is the Teledyne Detcon 370-646400-000?The Teledyne Detcon 370-646400-000 is: NO2, Nitrogen Dioxide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-646400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-747400-000 Cl2, Chlorine plug-in sensor for DM-500
What is the Teledyne Detcon 370-747400-000?The Teledyne Detcon 370-747400-000 is: Cl2, Chlorine plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-747400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-747500-000 Br2, Bromine plug-in sensor for DM-500
What is the Teledyne Detcon 370-747500-000?The Teledyne Detcon 370-747500-000 is: Br2, Bromine plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-747500-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-747600-000 ClO2, Chlorine Dioxide 0-50 ppm plug-in sensor for DM-500
What is the Teledyne Detcon 370-747600-000?The Teledyne Detcon 370-747600-000 is: ClO2, Chlorine Dioxide 0-50 ppm plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual. The Model 500 Replacement Sensors group in the Detcon price book lists 27 orderable part numbers; calibrated for the 0-50 ppm range.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-747600-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-777700-000 ClO2, Chlorine Dioxide 0-1 ppm plug-in sensor for DM-500
What is the Teledyne Detcon 370-777700-000?The Teledyne Detcon 370-777700-000 is: ClO2, Chlorine Dioxide 0-1 ppm plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual. The Model 500 Replacement Sensors group in the Detcon price book lists 27 orderable part numbers; calibrated for the 0-1 ppm range.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-777700-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 370-848400-000 H2, Hydrogen (ppm range) plug-in detector assembly
What is the Teledyne Detcon 370-848400-000?The Teledyne Detcon 370-848400-000 is: H2, Hydrogen (ppm range) plug-in detector assembly. Miscellaneous accessories and replacement parts for Teledyne Detcon fixed gas detection systems, spanning cable glands, NPT plugs and adapters, O-rings, LED indicators, analyzer expansion kits and boards, 700 series bottom housing assemblies, and the Model 700 remote alarm module. Cable glands are offered in aluminum, brass, and stainless steel with NPT and M20 threads sized to two cable diameter ranges. Housing bottom assemblies for the FP-700, TP-700, and IR-700 include the flame arrestor and maintain the detector's explosion-proof protection method.Key specificationsCable glands in 1/2 inch NPT, 3/4 inch NPT, and M20 thread typesGland materials: aluminum, stainless steel, and brass, with brass versions specified for non-H2S environmentsTwo gland cable ranges: 7.2 to 11.7 mm and 9.4 to 14.0 mm outer diameter700 series housing bottom assemblies include the flame arrestor (Ex d flameproof construction)3/4 inch NPT plugs, 3/4 to 1/2 inch NPT adapters, and cord connectors for condulet enclosure portsExpansion kits and option boards (NEMA 4X, NEMA 7, and 19 inch rack) for Detcon Model 1000 series analyzer systemsWhere is it used?Typical service: Hazardous-area cable entries into detector junction boxes and alarm enclosures; Service and repair of 700 series detectors with factory housing and sensor parts; Expanding Detcon analyzer and controller systems with additional option positions.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-848400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 370-865878-700 CO2, Carbon dioxide 0-5% Vol. Plug-in Sensor for Model 1000
What is the Teledyne Detcon 370-865878-700?The Teledyne Detcon 370-865878-700 is: CO2, Carbon dioxide 0-5% Vol. Plug-in Sensor for Model 1000 Analyzer. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen. The Model 100 Replacement Sensors group in the Detcon price book lists 32 orderable part numbers; calibrated for the 0-5% vol. range.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-865878-700 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 370-949400-000 NO, Nitric Oxide plug-in sensor for DM-500
What is the Teledyne Detcon 370-949400-000?The Teledyne Detcon 370-949400-000 is: NO, Nitric Oxide plug-in sensor for DM-500. These are plug-in replacement sensor cells for Detcon Model 500 Series gas detectors, including the DM-500 electrochemical toxic gas models. Official Detcon 500 Series documentation shows the series is built around field-replaceable plug-in sensor cells carrying the 370- part number prefix, so a spent cell is swapped without replacing the transmitter electronics or the explosion-proof housing. After a cell change the detector is recalibrated non-intrusively with Detcon's handheld programming magnet, without opening the enclosure or declassifying the area. Detcon warrants new plug-in cells for the 500 Series for two years from the date of shipment, per the official instruction manual.Key specificationsPlug-in, field-replaceable sensor cell design; transmitter and explosion-proof enclosure stay in service370- part number prefix per official Detcon 500 Series documentationEach cell covers a specific target gas and measuring range matching the DM-500 detector configurationCells mount in the stainless steel sensor housing of Class I, Division 1 rated assembliesTwo year cell warranty from date of shipment per the official 500 Series instruction manualNon-intrusive recalibration after replacement via magnetic programming interfaceWhere is it used?Typical service: Scheduled sensor cell replacement on installed DM-500 series detectors; Maintenance spares for legacy Detcon 500 Series gas detection systems; Restoring detection performance without full detector replacement.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 370-949400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the FP-524D combustible gas sensor we carry. -

Teledyne Detcon 371-070700-01P H2, Hydrogen 0-1% Vol. plug-in sensor for DM-100
What is the Teledyne Detcon 371-070700-01P?The Teledyne Detcon 371-070700-01P is: H2, Hydrogen 0-1% Vol. plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen. The Model 100 Replacement Sensors group in the Detcon price book lists 32 orderable part numbers; calibrated for the 0-1% vol. range.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-070700-01P on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-090800-030 HBr, Hydrogen Bromide plug-in sensor for DM-100
What is the Teledyne Detcon 371-090800-030?The Teledyne Detcon 371-090800-030 is: HBr, Hydrogen Bromide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-090800-030 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-090900-030 HCl, Hydrogen Chloride plug-in sensor for DM-100
What is the Teledyne Detcon 371-090900-030?The Teledyne Detcon 371-090900-030 is: HCl, Hydrogen Chloride plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-090900-030 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-12EB00-100 C4H6, Butadiene plug-in sensor for DM-100
What is the Teledyne Detcon 371-12EB00-100?The Teledyne Detcon 371-12EB00-100 is: C4H6, Butadiene plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-12EB00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-12ED00-100 C2H4, Ethylene plug-in sensor for DM-100
What is the Teledyne Detcon 371-12ED00-100?The Teledyne Detcon 371-12ED00-100 is: C2H4, Ethylene plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-12ED00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-12EE00-100 CH3OH, Methanol plug-in sensor for DM-100
What is the Teledyne Detcon 371-12EE00-100?The Teledyne Detcon 371-12EE00-100 is: CH3OH, Methanol plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-12EE00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-12EJ00-100 C2H4O, Ethylene Oxide plug-in sensor for DM-100
What is the Teledyne Detcon 371-12EJ00-100?The Teledyne Detcon 371-12EJ00-100 is: C2H4O, Ethylene Oxide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-12EJ00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-12EO00-100 C2H5OH, Ethanol plug-in sensor for DM-100
What is the Teledyne Detcon 371-12EO00-100?The Teledyne Detcon 371-12EO00-100 is: C2H5OH, Ethanol plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-12EO00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-12EP00-100 CH2O, Formaldehyde plug-in sensor for DM-100
What is the Teledyne Detcon 371-12EP00-100?The Teledyne Detcon 371-12EP00-100 is: CH2O, Formaldehyde plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-12EP00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-131300-030 HCN, Hydrogen Cyanide plug-in sensor for DM-100
What is the Teledyne Detcon 371-131300-030?The Teledyne Detcon 371-131300-030 is: HCN, Hydrogen Cyanide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-131300-030 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-191900-001 AsH3, Arsine plug-in sensor for DM-100
What is the Teledyne Detcon 371-191900-001?The Teledyne Detcon 371-191900-001 is: AsH3, Arsine plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-191900-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-192000-005 PH3, Phosphine plug-in sensor for DM-100
What is the Teledyne Detcon 371-192000-005?The Teledyne Detcon 371-192000-005 is: PH3, Phosphine plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-192000-005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-192100-005 B2H6, Diborane plug-in sensor for DM-100
What is the Teledyne Detcon 371-192100-005?The Teledyne Detcon 371-192100-005 is: B2H6, Diborane plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-192100-005 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-242400-100 H2S, Hydrogen Sulfide plug-in sensor for DM-100
What is the Teledyne Detcon 371-242400-100?The Teledyne Detcon 371-242400-100 is: H2S, Hydrogen Sulfide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-242400-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-24EK00-100 CH3SH, Methyl mercaptan plug-in sensor for DM-100
What is the Teledyne Detcon 371-24EK00-100?The Teledyne Detcon 371-24EK00-100 is: CH3SH, Methyl mercaptan plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-24EK00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-24EZ00-100 C2H5SH, Ethyl mercaptan plug-in sensor for DM-100
What is the Teledyne Detcon 371-24EZ00-100?The Teledyne Detcon 371-24EZ00-100 is: C2H5SH, Ethyl mercaptan plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-24EZ00-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-272700-001 F2, Fluorine plug-in sensor for DM-100
What is the Teledyne Detcon 371-272700-001?The Teledyne Detcon 371-272700-001 is: F2, Fluorine plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-272700-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-282800-050 ClO2, Chlorine Dioxide 0-50 ppm plug-in sensor for DM-100
What is the Teledyne Detcon 371-282800-050?The Teledyne Detcon 371-282800-050 is: ClO2, Chlorine Dioxide 0-50 ppm plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen. The Model 100 Replacement Sensors group in the Detcon price book lists 32 orderable part numbers; calibrated for the 0-50 ppm range.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-282800-050 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-333300-010 HF, Hydrogen Fluoride plug-in sensor for DM-100
What is the Teledyne Detcon 371-333300-010?The Teledyne Detcon 371-333300-010 is: HF, Hydrogen Fluoride plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-333300-010 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-343400-025 O2, Oxygen Deficiency sensor for DM-100
What is the Teledyne Detcon 371-343400-025?The Teledyne Detcon 371-343400-025 is: O2, Oxygen Deficiency sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-343400-025 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-393900-001 O3, Ozone plug-in sensor for DM-100
What is the Teledyne Detcon 371-393900-001?The Teledyne Detcon 371-393900-001 is: O3, Ozone plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-393900-001 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry. -

Teledyne Detcon 371-444400-100 CO, Carbon Monoxide plug-in sensor for DM-100
What is the Teledyne Detcon 371-444400-100?The Teledyne Detcon 371-444400-100 is: CO, Carbon Monoxide plug-in sensor for DM-100. These are plug-in replacement sensor cells for the Teledyne Detcon DM-100 Series loop-powered toxic gas sensors. The DM-100 is designed around a plug-in, field-replaceable cell, so a spent cell is exchanged in the field while the encapsulated transmitter electronics and 316 stainless steel housing remain in service. The cells use large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Teledyne's official gas list for the DM-100 covers more than 25 target gases, including hydrogen sulfide, carbon monoxide, ammonia, chlorine, chlorine dioxide, hydrogen cyanide, sulfur dioxide, phosphine, and oxygen.Key specificationsPlug-in, field-replaceable electrochemical sensor cell designLarge surface area gold-plated pins reduce corrosion effects in harsh industrial environmentsEach cell is gas-specific and matches the DM-100 detector's published gas list of 25+ gasesCompatible with the DM-100 2-wire loop-powered 4-20 mA sensor platformCell replacement keeps the encapsulated transmitter electronics and 316 SS housing in serviceWhere is it used?Typical service: Scheduled cell replacement on installed DM-100 detectors; Maintenance spares for loop-powered toxic gas monitoring points; Changing an installed DM-100 point to a different target gas within the supported gas list.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 371-444400-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model 100 toxic gas sensor we carry.