Oldham Simtronics
Showing 1711–1755 of 2140 results
-

Oldham Simtronics MX16-0-000-1-0-0 MX16 controller, one analog (4-20mA) or digital input, with RS485
$1,130.00MX16 controller, one analog (4-20mA) or digital input, with RS485. Part number MX16-0-000-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,130.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-001-0-0-0 MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL)
$880.00MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL). Part number MX16-A-001-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $880.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-001-1-0-0 MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL), with RS485
$1,130.00MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL), with RS485. Part number MX16-A-001-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,130.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-003-0-0-0 MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL)
$880.00MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL). Part number MX16-A-003-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $880.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-003-1-0-0 MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL), with RS485
$1,130.00MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL), with RS485. Part number MX16-A-003-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,130.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-032-0-0-0 MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL)
$880.00MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL). Part number MX16-A-032-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $880.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-032-1-0-0 MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL), with RS485
$1,130.00MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL), with RS485. Part number MX16-A-032-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,130.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-200-0-0-0 MX16 controller, one analog (4-20mA) input for O2 (0-30% Vol.)
$880.00MX16 controller, one analog (4-20mA) input for O2 (0-30% Vol.). Part number MX16-A-200-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $880.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-200-1-0-0 MX16 controller, one analog (4-20mA) input for O2 (0-30% Vol.), with RS485
$1,130.00MX16 controller, one analog (4-20mA) input for O2 (0-30% Vol.), with RS485. Part number MX16-A-200-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,130.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-239-0-0-0 MX16 controller, one analog (4-20mA) input for CO2 (0-5% Vol.)
$880.00MX16 controller, one analog (4-20mA) input for CO2 (0-5% Vol.). Part number MX16-A-239-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $880.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-A-239-1-0-0 MX16 controller, one analog (4-20mA) input for CO2 (0-5% Vol.), with RS485
$1,130.00MX16 controller, one analog (4-20mA) input for CO2 (0-5% Vol.), with RS485. Part number MX16-A-239-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,130.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-001-0-0-0 MX16 controller Pack, with OLCT10N CH4 (0-5% Vol.)
$1,510.00MX16 controller Pack, with OLCT10N CH4 (0-5% Vol.). Part number MX16-N-001-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,510.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-001-1-0-0 MX16 controller Pack, with OLCT10N CH4 (0-5% Vol.), with RS485
$1,760.00MX16 controller Pack, with OLCT10N CH4 (0-5% Vol.), with RS485. Part number MX16-N-001-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,760.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-002-0-0-0 MX16 controller Pack, with OLCT10N CH4 (0-4.4% Vol.)
$1,510.00MX16 controller Pack, with OLCT10N CH4 (0-4.4% Vol.). Part number MX16-N-002-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,510.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-002-1-0-0 MX16 controller Pack, with OLCT10N CH4 (0-4.4% Vol.), with RS485
$1,760.00MX16 controller Pack, with OLCT10N CH4 (0-4.4% Vol.), with RS485. Part number MX16-N-002-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,760.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-003-0-0-0 MX16 controller Pack, with OLCT10N H2 (0-4% Vol.)
$1,510.00MX16 controller Pack, with OLCT10N H2 (0-4% Vol.). Part number MX16-N-003-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,510.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-003-1-0-0 MX16 controller Pack, with OLCT10N H2 (0-4% Vol.), with RS485
$1,760.00MX16 controller Pack, with OLCT10N H2 (0-4% Vol.), with RS485. Part number MX16-N-003-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,760.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-200-0-0-0 MX16 controller Pack, with OLCT10N O2 (0-30% Vol. – 2 years)
$1,510.00MX16 controller Pack, with OLCT10N O2 (0-30% Vol. - 2 years). Part number MX16-N-200-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,510.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-200-1-0-0 MX16 controller Pack, with OLCT10N O2 (0-30% Vol. – 2 years), with RS485
$1,760.00MX16 controller Pack, with OLCT10N O2 (0-30% Vol. - 2 years), with RS485. Part number MX16-N-200-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,760.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-204-0-0-0 MX16 controller Pack, with OLCT10N CO (0-300ppm)
$1,510.00MX16 controller Pack, with OLCT10N CO (0-300ppm). Part number MX16-N-204-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,510.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-204-1-0-0 MX16 controller Pack, with OLCT10N CO (0-300ppm), with RS485
$1,760.00MX16 controller Pack, with OLCT10N CO (0-300ppm), with RS485. Part number MX16-N-204-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,760.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-239-0-0-0 MX16 controller Pack, with OLCT10N CO2 (0-5% Vol.)
$1,510.00MX16 controller Pack, with OLCT10N CO2 (0-5% Vol.). Part number MX16-N-239-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,510.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX16-N-239-1-0-0 MX16 controller Pack, with OLCT10N CO2 (0-5% Vol.), with RS485
$1,760.00MX16 controller Pack, with OLCT10N CO2 (0-5% Vol.), with RS485. Part number MX16-N-239-1-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $1,760.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX256-1-0 Digital Controller MX256, c/w French user manual
$5,800.00Digital Controller MX256, c/w French user manual. Part number MX256-1-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 256 product line. List price $5,800.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MX256-2-0 Digital Controller MX256, c/w English user manual
$5,800.00Digital Controller MX256, c/w English user manual. Part number MX256-2-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 256 product line. List price $5,800.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics OLC(T) 100 Fixed Gas Detector
The OLC/OLCT 100 range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions, the OLCT 100 is suitable for detection of all gases in ATEX zones. The OLCT 100 is available in a stainless steel version, offering increased resistance to corrosive elements (ideal for marine, wastewater treatment plants, food processing activities, etc). This stainless steel intrinsically safe version is certified for use in zones 0 (gas) and 20 (dust), whereas all other versions of the OLCT 100 are certified for use in zones 1 (gas) and 21 (dust). Features Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Applications Steel mills Petrochemical facilities Chemical industry Pharmaceutical industry Food industry Refrigeration industry Water treatment Our products are always application-driven, solution-oriented. Options include: OLCT 100 transmitter with 4-20 mA output OLC 100 detector with a Wheatstone bridge output for detection of combustible gases IR Sensor The infrared sensor provides detection of CO2 and refrigerant gases and is warranty 2 years. OLCT 100 XP Explosion-proof version is equipped with a catalytic, electrochemical or semiconductor sensor, for detection of combustible, toxic gases or oxygen. OLCT 100 IS Intrinsically safe version is equipped with an electrochemical sensor for detection of toxic gases or oxygen. OLCT 100 XP IR Explosion-proof IR version is equipped with an infrared sensor for detection of CO2 , SF6 and some freons. OLCT 100 XP HT High temperature explosion-proof version for detection of combustible gases up to 200°C. High temperature cable included: 5, 10, 15 meter lengths. Reliability The OLC(T) 100 is SIL 2 certified by INERIS, according to the EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors. Unique advantages providing the solution you need Design advantages Pre-calibrated sensors for detection of: combustible gases: LEL catalytic and IR toxic gases oxygen Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Inputs Series 80 sensors have up to 9 glands dedicated to cable wiring Design advantages: The minimum configuration includes: 1 electrical input dedicated to a sensor. two 4-20 mA or binary inputs. This configuration allows any other sensor from the network to be recognized (e.g temperature sensor, emergency stop, flame detector, smoke detector). Outputs 4/20 mA with smart signal processing analog signal 4-20 mA data signals between 0 and 4 - 20 and 25mA The transmitted signal, between 0 and 3.2 mA and above 20 mA, can be processed to interpret and identify a wide range of trouble parameters such as: line faults, sensor faults, embedded electronics faults, ambiguity resolution, inhibition of calibration, maintenance call (initial drift or drift over time). RS485 (1200 bauds, 38kb Modbus ASCII for MX 62). The RS485 link gives access to : - sensor measurement - status and default - internal relay management Relays The relays are 2A / 250 VAC type with potential free SPDT contacts. Two types of relays: 2 gas alarm relays or supplementary inputs 1 fault relay The relays are actuated either directly by the sensor electronics or supplementary inputs, or from the MX62 central unit or the control system to which the sensor is connected. The relays can be in safety mode or not, triggered on increasing or decreasing alarms, manually* or automatically acknowledged. * By remote control, by pressing an external pushbutton connected to the dedicated binary input, by acknowledging on the MX 62 unit or the control system to which the sensor is connected. Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Technical advantages Stand-alone central unit For relay control, the OLCT 80 can operate as a standalone unit: an indisputable advantage in a classified explosion risk zone. Flexibility of connection modes OLCT 80 sensors can be connected either: in loop (opto-isolated - up to 16 sensors), 4-20 mA, under direct power and operate as a central unit. Operation traceability The operator can check records locally for the most recent time-date stamped events. Communication Remote dialogue with the sensor using IR remote control. Measurement power supply redundancy Independent ports allow a redundant connection to the measurement unit. Low power requirements The leading edge technology used in the OLCT80 transmitter makes it very energy efficient. This major advantage means that more sensors can be connected, with smaller wire cross-sections and over greater distances. Logistic advantages Loop arrangement The transmitter is perfectly adapted to mounting and connection to the digital fieldbus loop of the MX 62 unit. Supporting 1 to 3 digital addresses: the sensor block (detection element), the two 4-20 mA auxiliary inputs. Certification The OLCT80 Series is certified to the specifications required by standards EN 50054, 45544 and 50104 (environmental standards, explosive and toxic gases and oxygen) and to the specifications of standards EN 50270, EN 6052 (electromagnetic compatibility, ingress protection). OLCT 80 uses digital logic and software technologies. The sensors are protected and in compliance with the specifications of standard EN 51271: analog and digital values track each other homogeneity of digital resolution and response time with the specifications required internal self-diagnostics Ordering Information Accessories A Calibration cup (6331141) allows introduction of calibration gas on the sensor B Bypass adapter (6327910) allows measurement of samples C Splash guard system (6329004) protects the detector from liquid projections D Remote gas introduction head (6327911) allows introduction of gas without opening the detector E Removable protective filter (6335975) protects the sensor against projections and dust F Duct measurement kit (6793322) allows gas monitoring in a duct G Mounting bracket (6322420) allows the mounting of the detector to the ceiling H Protective cover (6123716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6793718) allows the replacement of another OLDHAM detector without redrilling J Wall mounted collecting cone (6331169) for use with lighter-than-air gases K Ceiling mount collecting cone (6331168) for use with lighter-than-air gases Product Data Sheet -

Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector
Design for commercial applications, OLC and OLCT10 detectors perfectly suit the protection of equipment and personnel in boiler or charging rooms where atmosphere may contain flammable gases. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Catalytic sensors 4-20mA output signal with OLCT 10 Dust and humidity resistant Fast and accurate response ATEX Approval for use in hazardous areas (zone 2 and 22) OLC10 and OLC10 TWIN OLC 10 TWIN allows connection of 2 sensors with a single channel without any additional junction box. Applications: Boiler rooms Charging rooms Wiring arrangement between OLC(T) 10 and MX 32 control unit Wiring arrangement between OLC 10 TWIN and MX 32 control unit Dimensions: Technical features: OLC 10 / OLC 10 TWIN OLCT 10 (Catalytic) Range Combustible gases - 0 to 100% LEL , Methane, Butane, Propane, LPG, Natural Gas or H2 Combustible Gases - 0 to 100% LEL Methane, Butane, Propane, GPL, Natural Gas or H2 Signal output Wheatstone Bridge Normal operation 4-20 mA (Fault < 0.5 mA or > 23.2 mA) Settings Managed by control unit Without opening the enclosure by means of 2 petentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Set to 23.2 mA if value > 100% LEL according to European standard EN 61779-4 Disable on request when managed by a suitable controller Consumption See on the manual of the controller 100 mA max Cabling OLC 10 : 3 Wire, shielded, core size 1,5 mm2 max. cable length 300 m 1 cable-gland M16 (outer \ 4 to 8 mm)OLC10 TWIN : shielded, core size 1,5 mm2, 3-wire to control unit, 4-wire between both sensors, max. cable length 300 m, 2 cable-glands M16 (outer \ 4 to 8 mm) 3-wire, shielded, core size 1,5 mm2, max. cable length 1km if connected with control unit (32 W max un loop) 1 cable gland M16 (outer \ 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP Rating IP65 IP65 Expected lifespan 36 to 48 months (sensor) 36 to 48 months (sensor) Operating temperature -10 to + 45 °C -10 to + 45 °C Operating humidity range -20 to +55°C -20 to +55°C Pressure Range 1 bar ± 20 % 1 bar ± 20 % Response Time Flammable gas : < 10s Flammable gas : < 10s Accuracy +/- 3% LEL +/- 3% LEL Certification EN 50270:2015 (type2) ATEX II 3 GD / Ex ec dc IIC T6 Gc Ex tc IIIC T85°C Dc EN 50270:2015 (type2) Product Data Sheet -

Oldham Simtronics OLC100-XP- Flameproof detector – with on-board XP catalytic sensor
$635.00Flameproof detector - with on-board XP catalytic sensor. Part number OLC100-XP- belongs to the Teledyne Gas and Flame Detection (Oldham) OLC(T) 100 product line. List price $635.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC(T) 100 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLC100-XPA- Flameproof detector – with on-board poison resistant XP catalytic sensor
$780.00Flameproof detector - with on-board poison resistant XP catalytic sensor. Part number OLC100-XPA- belongs to the Teledyne Gas and Flame Detection (Oldham) OLC(T) 100 product line. List price $780.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC(T) 100 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT 10N Fixed Digital Gas Detector
The OLCT 10N is a digital gas detector designed for detection of the most common gases in commercial and light industrial applications. Intended for use in combination with the MX 16, MX 32, MX43 or MX 256, the OLCT 10N provides a fast and accurate response. Up to 32 detectors can be connected on the same digital line or distributed on 8 lines. All transmitter information is received by the controller in less than 1 second. Non-intrusive operator interface requires only a simple magnetic wand and allows one man calibration without opening the enclosure, and calibration information, such as span reserve, is stored in the station. Certified IP65 and ATEX 3 GD for its explosive version, it is authorized for use in ATEX zones 2 and 22 and is waterproof and dustproof. Accessories Shock guard protector (2123717) OLCT 10N calibration tool kit (6331163) The OLCT 10N is the ideal solution for safe areas or zone 2 (22) ATEX locations. Configuration example Features: Detection of combustible gases, toxic gases or oxygen Digital technology Non-intrusive calibration Cost savings on wiring installation Applications: Cold rooms Car parks Technical features: Détecteur numérique OLCT 10N Range CH4, C3 H8, C4 H10, H2 O2 (> 2 years) O2 (5 years) CO H2S NO NO2 NH3 CO2 0-100 % LIE (-20°C à + 55°C) 0-30 % vol (-20°C à + 50°C) 0-30 % vol (-40°C à + 50°C) 0-300 ppm / 0-1000 ppm (-20°C à + 50°C) 0-30 ppm / 0-100 ppm (-20°C à + 50°C) 0-100 ppm / 0-300 ppm (-20°C à + 50°C) 0-10 ppm / 0-30 ppm (-20°C à + 50°C) 0-100 ppm / 0-1000 ppm (-20°C à + 40°C) 0-5000ppm / 0-5% vol / 0-100% vol (-40 à + 50°C) Output RS485 Modbus, proprietary protocol Power supply 12-30 Vcc Consumption Electrochemical sensor: Catalytic sensor : CO2 Infrared sensor: 2.5 mA in normal operation @ 24 Vdc 50 mA in normal operation @ 24 Vdc 20mA in normal operation @24Vdc Calibration Non-intrusive Cable inlet 2 PE M16, diamètre 4 à 8 mm Cable inlet With MX 32 (24 Vdc version): Up to 8 toxic or oxygen gas detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Up to 8 explosive gas detectors at 225 m with a 0.9 mm² (AWG 18) core size cable With MX 43: 2 x M16 cable entries, outer diameter 4 to 8 mm Up to 32 detectors at 1000 m with a 0.9 mm² (AWG 18) core size cable Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Dimensions (LxHxW) 118x110x60 mm Materials ABS, UV and shocks resistant Ingress protection IP65 Approvals for ATEX explosive versions II 3 GD Ex nA nC IIC T4 Gc for explosimetric versions Ex tc IIIC T135°C Dc -20°C<Ta<+55°C Electromagnetic compatibility according to EN50270 Ordering Information Part Number Description OLCT10N-001 Digital transmitter OLCT 10N, range 0-100% LEL CH4 OLCT10N-003 Digital transmitter OLCT 10N, range 0-100% LEL H2 OLCT10N-004 Digital transmitter OLCT 10N, range 0-100% LEL C4 H10 OLCT10N-005 Digital transmitter OLCT 10N, range 0-100% LEL C3 H8 OLCT10N-200 Digital transmitter OLCT 10N, range 0-30% vol O2 (2 year O2 sensor) OLCT10N-272 Digital transmitter OLCT 10N, range 0-30% vol O2 (5 year O2 sensor) OLCT10N-204 Digital transmitter OLCT 10N, range 0-300 ppm CO OLCT10N-205 Digital transmitter OLCT 10N, range 0-1000 ppm CO OLCT10N-213 Digital transmitter OLCT 10N, range 0-30 ppm H2S OLCT10N-214 Digital transmitter OLCT 10N, range 0-100 ppm H2S OLCT10N-216 Digital transmitter OLCT 10N, range 0-100 ppm NO OLCT10N-217 Digital transmitter OLCT 10N, range 0-300 ppm NO OLCT10N-219 Digital transmitter OLCT 10N, range 0-10 ppm NO2 OLCT10N-220 Digital transmitter OLCT 10N, range 0-30 ppm NO2 OLCT10N-231 Digital transmitter OLCT 10N, range 0-100 ppm NH3 OLCT10N-232 Digital transmitter OLCT 10N, range 0-1000 ppm NH3 OLCT10N-252 Digital transmitter OLCT 10N, range 0-5000 ppm CO2 OLCT10N-239 Digital transmitter OLCT 10N, range 0-5% vol CO2 OLCT10N-241 Digital transmitter OLCT 10N, range 0-100% vol CO2 Product Data Sheet -

Oldham Simtronics OLCT 20 Fixed Gas Detector
The OLCT 20 series sensors are designed for initial assembly applications, which can be installed in shelters, on skids, for monitoring in very small spaces or for on-board applications. They are mounted via M25 or 3/4" NPT threads or a special accessory to ensure a robust mounting without the need for an additional junction box. The OLCT 20 transmitters provide a 4-20mA output that can be directly connected to PLCs with a maximum current consumption of 100mA at 24VDC. They are certified ATEX explosion-proof by INERIS. Their IIC T6, makes them perfectly suited for the detection of hydrogen. The stainless steel detectors offer protection and resistance to corrosive agents. IP 66 rated, they are resistant to dust and water splashes. The OLCT 20's pre-calibrated sensors can be disconnected from the holder by rotation. These "smart" sensors can be calibrated on a workbench, outside of hazardous areas. Catalytic oxidation sensors for combustible gases are specially treated to resist poisons. They benefit from extremely fast response times and total reliability. Features Stainless steel base Small size Atex certification for H2 applications Pre-calibrated sensor Applications Machine Shelter Small spaces Mobility Refrigeration industry Water treatment Sensor specifications Accessories: 1 Tool kit (6147869) 2 Calibration cup (6331141) allows introduction of calibration gas on the sensor 3 Bypass adapter (6327910) allows measurement of samples 4 Splash guard system (6329004) protects the detector from liquid projections 5 Remote gas introduction head (6327911) allows gas injection without having to access the sensor 6 Removable protective filter (6335975) protects the sensor against projections and dust 7 Wall mounted collecting cone (6331169) for use with lighter-than-air gases 8 Pitot tube (6793322) Specifications Type XP transmitter Gas detection principle Catalytic/Electrochemical / Catharometric Detected gases Flammable, toxics and oxygen Measuring range see chart Sensor housing Stainless steel type 316L Precalibrated sensor YES Power supply at the detector 15 to 30 VDC Maximum power consumption 100 mA (catalytic) Output signal 4-20 mA Wiring 3 reinforced wires (catalytic) Load impedance 250 Ω (catalytic) Depending on power supply (chemical) Wiring connection delivered with a 6 mm-diameter cable Mounting M25 thread or 3/4" NPT or via accessory Ingress protection IP66 Certification II 2 GD Ex db IIC T6 Gb Ex tb IIIC T85°C Db T.Amb: -20°C to 70°C INERIS 01 ATEX 0004X EMC Marking EN 50270:2015 (type 2) Weight 800 g Dimensions L 130 x D 60 Operating temperature (for electronics) -25°C to +60°C Product Data Sheet -

Oldham Simtronics OLCT 60 Fixed Gas Detector
The generation of high quality gas detectors designed for the detection of flammable, toxic gases or oxygen. The OLCT 60 Series is available in several versions: Explosion-proof XP or intrinsically safe IS sensor (combustible, toxic or oxygen versions). Remote or on-board sensor. The OLCT 60 can be remotely mounted, allowing detection in inaccessible locations or in Zone 0 or 20 in the case of the intrinsically safe (IS) version. The OLCT 60 is equipped with a local display and non-intrusive access to a safe menu. In hazardous areas, calibration can be done without the need of a hot work permit. The detector units are made of 316L stainless steel, and are rugged and resistant to corrosion. Certified IP66, the OLCT 60 is sealed against dust and splash water. The versatile instrument is the ideal solution for gas detection covering all industrial needs for a wide variety of applications. Features Pre-calibrated sensors Non-intrusive calibration Infrared Version Infrared sensor available An infrared sensor is already available for CO2, SF6 and refrigerant gases detection. Sensors technical specifications: XP Transmitter with XP sensor: Sensor Catalytic / Electrochemical / Semi conductor / Infrared Detected gases Explosive or toxic gases, O2, VOC and refrigerant Material Epoxy coated aluminium + 316 stainless steel sensor Pre-calibrated block Yes Power supply 16 to 30 V DC Average consumption 140 mA (catalytic) 80 mA (electrochemical) 120 mA (infrared sensor) Output signal 0 - 23 mA (4-20 mA reserved for measurement) Cable 3 active wires, shielded cable Max. cable loop resistance / length Catalytic: 32 Ω / 1 km at 1.5 mm2 (16 AWG) Electrochemical and XP IR: 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) Ingress protection IP 66 Approvals OLCT60D (with integrated cell): ATEX II 2 GD Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 60°C OLCT60D d (with remote cell): ATEX II 2 GD Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 70°C (for the detector) ATEX II 2 GD - Ex db IIC T6 Gb - Ex tb IIIC T85°C Db Ambient temperature: -20°C to 70°C (for the remote cell) Electromagnetic compatibility according to EN50270 Weight 2.1 kg Dimensions 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches Operating temperature -20°C to +60°C XP transmitter with IS sensor: Sensor Electrochemical Detected gases Toxic gases or O2 Material Epoxy coated aluminium + 316 stainless steel sensor Pre-calibrated block Yes Power supply 16 to 30 V DC Average consumption 80 mA Output signal 0 - 23 mA (4-20 mA reserved for measurement) Cable 3 active wires, shielded cable Max. cable loop resistance / length with OLDHAM controller 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) Ingress protection IP 66 Approvals OLCT60id (with integrated cell): ATEX II 2 GD - Ex db [ia Ga] ia IIC T4 Gb - Ex tb [ia Da] ia IIIC T135°C Db Ambient temperature: -20°C to 60°C OLCT60D id: (with remote cell) ATEX II 2 (1) GD - Ex db [ia Ga] IIC T4 Gb - Ex tb [ia Da] IIIC T135°C Db Ambient temperature: -20°C to 60°C (for the detector) ATEX II 1 GD - Ex ia IIC T4 Ga - Ex ia IIIC T135°C Da Ambient temperature: -20°C to 70°C (for the remote cell) Electromagnetic compatibility according to EN 50270 Weight 2.1 kg Dimensions 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches Operating temperature -20°C to +60°C Accessories: A Calibration cup (6331141) allows introduction of calibration gas on the sensor B Bypass adapter (6327910) allows measurement of samples C Splash guard system (6329004) protects the detector from liquid projections D Remote gas introduction head (6327911) allows introduction of gas without opening the detector E Removable protective filter (6335975) protects the sensor against projections and dust F Duct measurement kit (6793322) allows gas monitoring in a duct G Mounting bracket (6322420) allows the mounting of the detector to the ceiling H Protective cover (6123716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6793718) allows the replacement of another OLDHAM detector without re-drilling J Wall mounted collecting cone (6331169) for use with lighter-than-air gases K Ceiling mount collecting cone (6331168) for use with lighter-than-air gases L Tool kit (6147877) Product Data Sheet -

Oldham Simtronics OLCT 80 Fixed Gas Detector
Features Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Remote versions available XP, IS Integrated relays Direct link, 4-20 mA, loop and isolated sensor mode Unique advantages providing the solution you need Design advantages Pre-calibrated sensors for detection of: combustible gases: LEL catalytic and IR toxic gases oxygen Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Inputs Series 80 sensors have up to 9 glands dedicated to cable wiring Design advantages: The minimum configuration includes: 1 electrical input dedicated to a sensor. two 4-20 mA or binary inputs. This configuration allows any other sensor from the network to be recognized (e.g temperature sensor, emergency stop, flame detector, smoke detector). Outputs 4/20 mA with smart signal processing analog signal 4-20 mA data signals between 0 and 4 - 20 and 25mA The transmitted signal, between 0 and 3.2 mA and above 20 mA, can be processed to interpret and identify a wide range of trouble parameters such as: line faults, sensor faults, embedded electronics faults, ambiguity resolution, inhibition of calibration, maintenance call (initial drift or drift over time). RS485 (1200 bauds, 38kb Modbus ASCII for MX 62). The RS485 link gives access to : - sensor measurement - status and default - internal relay management Relays The relays are 2A / 250 VAC type with potential free SPDT contacts. Two types of relays: 2 gas alarm relays or supplementary inputs 1 fault relay The relays are actuated either directly by the sensor electronics or supplementary inputs, or from the MX62 central unit or the control system to which the sensor is connected. The relays can be in safety mode or not, triggered on increasing or decreasing alarms, manually* or automatically acknowledged. * By remote control, by pressing an external pushbutton connected to the dedicated binary input, by acknowledging on the MX 62 unit or the control system to which the sensor is connected. Alarms 2 integrated gas alarms with relays 1 fault alarm with relay Technical advantages Stand-alone central unit For relay control, the OLCT 80 can operate as a standalone unit: an indisputable advantage in a classified explosion risk zone. Flexibility of connection modes OLCT 80 sensors can be connected either: in loop (opto-isolated - up to 16 sensors), 4-20 mA, under direct power and operate as a central unit. Operation traceability The operator can check records locally for the most recent time-date stamped events. Communication Remote dialogue with the sensor using IR remote control. Measurement power supply redundancy Independent ports allow a redundant connection to the measurement unit. Low power requirements The leading edge technology used in the OLCT80 transmitter makes it very energy efficient. This major advantage means that more sensors can be connected, with smaller wire cross-sections and over greater distances. Logistic advantages Loop arrangement The transmitter is perfectly adapted to mounting and connection to the digital fieldbus loop of the MX 62 unit. Supporting 1 to 3 digital addresses: the sensor block (detection element), the two 4-20 mA auxiliary inputs. Certification The OLCT80 Series is certified to the specifications required by standards EN 50054, 45544 and 50104 (environmental standards, explosive and toxic gases and oxygen) and to the specifications of standards EN 50270, EN 6052 (electromagnetic compatibility, ingress protection). OLCT 80 uses digital logic and software technologies. The sensors are protected and in compliance with the specifications of standard EN 51271: analog and digital values track each other homogeneity of digital resolution and response time with the specifications required internal self-diagnostics Configuration Options Stand Alone Version Standard Version Stand Alone Version Specifications Type Transmitter-sensor Detected gases Explosive, toxic and oxygen Detection principles Catalytic, Electrochemical, IR, Semiconductor Sensor block Pre-calibrated Device Aluminium enclosure and stainless steel 316Lfor sensor housing Visualisation 4-digit LCD display for measurement and one alphanumeric line for texts, Pictograms - backlighting 4 indicator lamps : one green : "OperationOK", one yellow : "Fault", red : "Alarm 1" and "Alarm 2" Power supply From 16 to 28 VDC at transmitter entry Maximum power with digital link - 0.2 W (electrochemical cell) - 1.3 W ( catalytic / SM ) with I output at 25 mA - 0.9 W (electrochemical cell) - 2 W ( catalytic / SM ) with I output at 25 mA and relays activated - 2.4 W (electrochemical cell) - 3.5 W ( catalytic / SM ) Power supply to sensor terminals Two independent inputs : 16 to 28 VDC (catalytic / IR / SM cells) 12 to 28 VDC (electrochemical cell) Inputs Two analog inputs 4-20 mA (load resistance 120 Ω, can be used as binary) Signal outputs Logic (relay contacts) Relay Analog Standardised 4-20 mA output Digital Two independent opto-isolated RS 485 ports Signal faults I < 0.5 mA Alarms 2 programmable thresholds per channel Relays Type SPDT Number 3 Contact RCT changer-over Breaking capacity 2A / 250 VAC / 30 VDC Wiring / connection Basic version, 6 inputs : 4 M20 and 2 M25 On request : 3 additional, 2 M20 and 1 M25 Load resistance on the 4-20 mA 500 Ω Loop resistance Under central unit 21 VDC: 128 ohms ( electrochemical cell ) - 32 Ω ( catalytic / SM ) - 16 Ω (IR) Protection number IP 66 Operating temperatures - 20 °C to + 60 °C ( electronics, see table for detection cells ) Dimensions See drawings Weight OLCT 80 : 3,5 kg, OLCT80 version IR : 5,3 kg Accessories A Infrared remote control B Tool kit C Bypass adapter D Cover key E Calibration cup F Remote gas introduction device G Gas collector H Splash guard Homologations Certification Atex OLCT 80 d OLCT 80 id ATEX II 2GD ATEX II 2GD Ex d IIC T6...T5 Gb Ex d ia IIC T4 Gb Ex tb IIIC T85°C...T100°C Db Ex tb ia IIIC T135°C Db INERIS 03ATEX0240X INERIS 03ATEX0240X Chine OLCT 80 d OLCT 80 id GYJ17.1201X - Ex d IIC T6/T5 Gb GYJ17.1202X - Ex d ia IIC T4 Gb Electromagnetic compatibility Complies with EN 50270 Product Data Sheet -

Oldham Simtronics OLCT10 Toxic Gas Detector
Designed for commercial applications, OLCT 10 detector perfectly suit the protection of equipment and personnel in presence of combustion and exhaust gases or refrigerants (freons) in ambient air. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Electrochemical and semiconductor sensors 4-20 mA output signal Dust and humidity resistant (IP65) Fast and accurate response Up to 5 detectors on same line (CO, NO, NO2) Applications: Cold rooms Car parks Wiring of 1 OLCT 10 detector Wiring in parallel of 2 OLCT 10 detecting same gas (CO, NO or NO2) Wiring of 1 OLCT 10 SC (with a semi-conductor cell) Dimensions: Technical features: Electrochemical sensor Semiconductor sensor Range CO (0-300 ppm), NO (0-100 ppm), NO2 (0-30 ppm) R134a, R404a, R22, R410a etc. Signal output Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Settings Without opening the enclosure by means of 2 potentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Power Supply 15 to 30 Vdc (nominal 24 Vdc) 15 to 30 Vdc (nominal 24 Vdc) Consumption 30 mA max. 100 mA max. Cabling 2-wire, shielded, core size 0.9mm2 2 cable gland M16 (outer 4 to 8 mm) 3-wire, shielded, core size 0.9mm2 1 cable gland M16 (outer 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP rating IP65 IP65 Expected Lifespan 24 to 48 month, depending gas to detect > 24 months Operating temperature -20 to +55°C -20 to +55°C Operating humidity 15% HR to 90% HR 20% HR to 90% HR Pressure range 1 bar ± 10 % 1 bar ± 10 % Response Time NO2: T90 < 60s, NO : T90 < 120 CO : T50 < 15s, Fréon R134A : T50 < 30s Certification Electromagnetic compatibility according to EN 50270:2015 (type2) Complies with EN 14624 for freon Product Data Sheet -

Oldham Simtronics OLCT10-001 OLCT 10 CH4, Methane 0-100% LEL (5% Vol.)
$390.00OLCT 10 CH4, Methane 0-100% LEL (5% Vol.). Part number OLCT10-001 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $390.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-002 OLCT 10 CH4, Methane 0-100% LEL (4.4% Vol.)
$390.00OLCT 10 CH4, Methane 0-100% LEL (4.4% Vol.). Part number OLCT10-002 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $390.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-003 OLCT 10 H2, Hydrogen 0-100% LEL
$390.00OLCT 10 H2, Hydrogen 0-100% LEL. Part number OLCT10-003 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $390.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-004 OLCT 10 C4H10, Butane 0-100% LEL
$390.00OLCT 10 C4H10, Butane 0-100% LEL. Part number OLCT10-004 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $390.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-005 OLCT 10 C3H8, Propane 0-100% LEL
$390.00OLCT 10 C3H8, Propane 0-100% LEL. Part number OLCT10-005 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $390.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-204 OLCT 10 CO, Carbone Monoxide 0-300 ppm
$545.00OLCT 10 CO, Carbone Monoxide 0-300 ppm. Part number OLCT10-204 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $545.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-216 OLCT 10 NO, Nitric Oxide 0-100 ppm
$645.00OLCT 10 NO, Nitric Oxide 0-100 ppm. Part number OLCT10-216 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $645.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-220 OLCT 10 NO2, Nitrogen Dioxide 0-30 ppm
$645.00OLCT 10 NO2, Nitrogen Dioxide 0-30 ppm. Part number OLCT10-220 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $645.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-500 OLCT 10 R12, 0-1% Vol.
$495.00OLCT 10 R12, 0-1% Vol.. Part number OLCT10-500 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $495.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-501 OLCT 10 R22, 0-2000 ppm
$495.00OLCT 10 R22, 0-2000 ppm. Part number OLCT10-501 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $495.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT10-502 OLCT 10 R134A, 0-2000 ppm
$495.00OLCT 10 R134A, 0-2000 ppm. Part number OLCT10-502 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC 10 / OLCT 10 product line. List price $495.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC10 and OLCT10 Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page.