Oldham Simtronics
Showing 91–135 of 2140 results
-

Oldham Simtronics 18108472 Cl2, Chlore 9 ppm N2 112L (112DA)
$470.00Cl2, Chlore 9 ppm N2 112L (112DA). Part number 18108472 belongs to the Teledyne Gas and Flame Detection (Oldham) Calibration gases (Arras) product line. List price $470.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 18108498 SO2, Sulfur Dioxide 25 ppm N2 112L (112DA)
$335.00SO2, Sulfur Dioxide 25 ppm N2 112L (112DA). Part number 18108498 belongs to the Teledyne Gas and Flame Detection (Oldham) Calibration gases (Arras) product line. List price $335.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 18108506 2.5% CH4, 100ppm CO, 25ppm H2S, 19% O2 N2 112L (112DA)
$400.002.5% CH4, 100ppm CO, 25ppm H2S, 19% O2 N2 112L (112DA). Part number 18108506 belongs to the Teledyne Gas and Flame Detection (Oldham) Calibration gases (Arras) product line. List price $400.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 18108930 CH4, Methane 1,5% Vol. O2, Oxygen 20% Vol. N2 112L (112DA)
$255.00CH4, Methane 1,5% Vol. O2, Oxygen 20% Vol. N2 112L (112DA). Part number 18108930 belongs to the Teledyne Gas and Flame Detection (Oldham) Calibration gases (Arras) product line. List price $255.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 18108970 NO, Nitric Oxide 50 ppm N2 112L (112DA)
$470.00NO, Nitric Oxide 50 ppm N2 112L (112DA). Part number 18108970 belongs to the Teledyne Gas and Flame Detection (Oldham) Calibration gases (Arras) product line. List price $470.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 245-906385 Laser pointer for GD1 Alignment kit
$155.00What is the Oldham Simtronics 245-906385?The Oldham Simtronics 245-906385 is: Laser pointer for GD1 Alignment kit. The GD1 is a laser based open path detector for hydrogen sulphide, built as a separate transmitter and receiver. The transmitter emits an infrared laser beam, shaped as a cone rather than a focused pointer beam, and the receiver measures how much light the gas absorbs along the line of sight. The laser diode wavelength is monitored more than 500 times per second so that the absorption line keeps matching the target gas, which is why the detector needs no on-site calibration for its whole life and shows no cross interference from other gases. The laser is Class 1 and eye safe, and both transmitter and receiver have heated optics inside stainless steel housings.About the GD1 Open Path Laser Gas Detectors lineThis part is an accessory for the GD1 Open Path Laser Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: near infrared laser scanning with a tunable laser diode, Class 1 eye safeDetected gas: hydrogen sulphide (H2S)Range: 0 to 200 ppm*m default; path length 5 to 75 mAccuracy and repeatability: better than plus or minus 8 ppm*m (under plus or minus 4% of full range)Response time: 5 secondsOutput: 4-20 mA sink or source, factory set, maximum load impedance 500 ohm, with HARTFault signalling: 1 mA fault, 2 mA beam block, optional 3 mA warning; beam block declared above 98% obscurationAlignment tolerance plus or minus 0.3 degrees, with heated optics on both transmitter and receiverSafety Integrity Level 2, with a functional test interval of once per yearCalibration factory set, no field recalibrationWhat should you check before ordering?The GD1 carries a 5 year limited warranty, and it is void if the detector was installed or operated outside the procedures in the operating manual. Alignment is the field risk worth planning for: the laser beam presents a smaller target area than a conventional open path system, so it needs higher alignment accuracy to reach sufficient optical transmission, and poor alignment reduces system performance rather than failing outright. During alignment the 4-20 mA output holds at 2 mA and at power up it holds 1 mA, so a control room seeing those values during commissioning is reading a documented state, not a fault.How do the part numbers differ?The price book lists three orderable forms of the same optical path: a complete System (transmitter and receiver together), a Transmitter on its own, and a Receiver on its own, so a damaged half can be replaced without rebuying the pair.Where is it used?Typical service: Perimeter and fence line hydrogen sulphide monitoring; Open outdoor structures where a single path replaces multiple point detectors; Property boundary monitoring on oil and gas sites; Installations where cross interference from other gases must be excluded.How do I order or get a quote?PE Energy supplies the Oldham Simtronics 245-906385 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD1 laser open path H2S gas detector already in our catalogue. -

Oldham Simtronics 31125 MX 62 AEAM for alarms acceptance of smoke detectors (to connect to AIM module)
$670.00MX 62 AEAM for alarms acceptance of smoke detectors (to connect to AIM module). Part number 31125 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 62 / MX62 TP product line. List price $670.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 32130291 PVC Tubing D4-D6 (per meter)
$20.00PVC Tubing D4-D6 (per meter). Part number 32130291 belongs to the Teledyne Gas and Flame Detection (Oldham) Calibration gases (Arras) product line. List price $20.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 373-901337 Terminal GD10P/PE/L 4-5
$49.00Terminal GD10P/PE/L 4-5. Part number 373-901337 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $49.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 373-903947 Terminal GD10P/PE/L 1-3
$53.00Terminal GD10P/PE/L 1-3. Part number 373-903947 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $53.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 499-810874 Sample flow housing for GD10P. This is also used for testing
$390.00What is the Oldham Simtronics 499-810874?The Oldham Simtronics 499-810874 is: Sample flow housing for GD10P. This is also used for testing / Calibration check. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-810874 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-810913 Standard front cover. Weather Protection, GD10P
$172.00Standard front cover. Weather Protection, GD10P. Part number 499-810913 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $172.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 499-811938 Duct mounting kit for GD10P. Mounting flange and front cover
$600.00What is the Oldham Simtronics 499-811938?The Oldham Simtronics 499-811938 is: Duct mounting kit for GD10P. Mounting flange and front cover. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-811938 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-813397 Mosquito net, GD10P, steel mesh
$135.00What is the Oldham Simtronics 499-813397?The Oldham Simtronics 499-813397 is: Mosquito net, GD10P, steel mesh. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-813397 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-815271 Duct Mounting Flange, GD10PE
$595.00What is the Oldham Simtronics 499-815271?The Oldham Simtronics 499-815271 is: Duct Mounting Flange, GD10PE. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-815271 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-815430 Weather Protection, GD10PE
$905.00What is the Oldham Simtronics 499-815430?The Oldham Simtronics 499-815430 is: Weather Protection, GD10PE. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-815430 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-815712 Sunshade, GD10P/GD10PE
$635.00What is the Oldham Simtronics 499-815712?The Oldham Simtronics 499-815712 is: Sunshade, GD10P/GD10PE. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-815712 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-815733 Sample flow housing,GD10PE
$805.00What is the Oldham Simtronics 499-815733?The Oldham Simtronics 499-815733 is: Sample flow housing,GD10PE. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-815733 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-816584 Back cover, kit GD10P/PE/L
$95.00Back cover, kit GD10P/PE/L. Part number 499-816584 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $95.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 499-816816 TAG 1x80x20mm, SS 316, CUSTOM TEXT, including washer and split ring (for GD10
$55.00TAG 1x80x20mm, SS 316, CUSTOM TEXT, including washer and split ring (for GD10. Part number 499-816816 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiTox product line. List price $55.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DGi-TT7-E Electrochemical Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics 499-816867 Pipe mounting plate, kit GD10P, M8x2,5″ A4 (for 2″ pole)
$225.00What is the Oldham Simtronics 499-816867?The Oldham Simtronics 499-816867 is: Pipe mounting plate, kit GD10P, M8x2,5" A4 (for 2" pole). The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-816867 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 499-817033 Reflector plate Alignment kit
$1,110.00What is the Oldham Simtronics 499-817033?The Oldham Simtronics 499-817033 is: Reflector plate Alignment kit. The GD1 is a laser based open path detector for hydrogen sulphide, built as a separate transmitter and receiver. The transmitter emits an infrared laser beam, shaped as a cone rather than a focused pointer beam, and the receiver measures how much light the gas absorbs along the line of sight. The laser diode wavelength is monitored more than 500 times per second so that the absorption line keeps matching the target gas, which is why the detector needs no on-site calibration for its whole life and shows no cross interference from other gases. The laser is Class 1 and eye safe, and both transmitter and receiver have heated optics inside stainless steel housings.About the GD1 Open Path Laser Gas Detectors lineThis part is an accessory for the GD1 Open Path Laser Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: near infrared laser scanning with a tunable laser diode, Class 1 eye safeDetected gas: hydrogen sulphide (H2S)Range: 0 to 200 ppm*m default; path length 5 to 75 mAccuracy and repeatability: better than plus or minus 8 ppm*m (under plus or minus 4% of full range)Response time: 5 secondsOutput: 4-20 mA sink or source, factory set, maximum load impedance 500 ohm, with HARTFault signalling: 1 mA fault, 2 mA beam block, optional 3 mA warning; beam block declared above 98% obscurationAlignment tolerance plus or minus 0.3 degrees, with heated optics on both transmitter and receiverSafety Integrity Level 2, with a functional test interval of once per yearCalibration factory set, no field recalibrationWhat should you check before ordering?The GD1 carries a 5 year limited warranty, and it is void if the detector was installed or operated outside the procedures in the operating manual. Alignment is the field risk worth planning for: the laser beam presents a smaller target area than a conventional open path system, so it needs higher alignment accuracy to reach sufficient optical transmission, and poor alignment reduces system performance rather than failing outright. During alignment the 4-20 mA output holds at 2 mA and at power up it holds 1 mA, so a control room seeing those values during commissioning is reading a documented state, not a fault.How do the part numbers differ?The price book lists three orderable forms of the same optical path: a complete System (transmitter and receiver together), a Transmitter on its own, and a Receiver on its own, so a damaged half can be replaced without rebuying the pair.Where is it used?Typical service: Perimeter and fence line hydrogen sulphide monitoring; Open outdoor structures where a single path replaces multiple point detectors; Property boundary monitoring on oil and gas sites; Installations where cross interference from other gases must be excluded.How do I order or get a quote?PE Energy supplies the Oldham Simtronics 499-817033 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD1 laser open path H2S gas detector already in our catalogue. -

Oldham Simtronics 540-903951 Ring Sealing (Ø58×3) for Sample flow GD10P
$9.00Ring Sealing (Ø58x3) for Sample flow GD10P. Part number 540-903951 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $9.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 540-903952 Ring Sealing (Ø60×3) for Sample flow GD10PE
$9.00Ring Sealing (Ø60x3) for Sample flow GD10PE. Part number 540-903952 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $9.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 540-903954 Ring Sealing (Ø65×2) for Back cover GD10P/PE/L
$9.00Ring Sealing (Ø65x2) for Back cover GD10P/PE/L. Part number 540-903954 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $9.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 599-810646 Test nipple, GD10P
$29.00Test nipple, GD10P. Part number 599-810646 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $29.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 599-811937 Test nipple for GD10P Duct mount
$36.00Test nipple for GD10P Duct mount. Part number 599-811937 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $36.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 599-816841 Sunshade, GD10P, vertical mounting (pipe mounting plate, kit required)
$210.00What is the Oldham Simtronics 599-816841?The Oldham Simtronics 599-816841 is: Sunshade, GD10P, vertical mounting (pipe mounting plate, kit required). The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 599-816841 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 599-818154 Gas test socket GD10P
$15.00What is the Oldham Simtronics 599-818154?The Oldham Simtronics 599-818154 is: Gas test socket GD10P. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations.About the GD10P / GD10PE Point IR Gas Detectors lineThis part is an accessory for the GD10P / GD10PE Point IR Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics 599-818154 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics 599-904176 Protective Cap for test nipple GD10P/PE
$9.00Protective Cap for test nipple GD10P/PE. Part number 599-904176 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $9.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6090319 Paper rolls (1pc) for desk top printer DPU-414 – minimum orderable quantity is 5pcs
$30.00Paper rolls (1pc) for desk top printer DPU-414 - minimum orderable quantity is 5pcs. Part number 6090319 belongs to the Teledyne Gas and Flame Detection (Oldham) CPS Car Park System product line. List price $30.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6090336 Paper rolls (1pc) for AP1200 – minimum orderable quantity is 5 pcs
$25.00Paper rolls (1pc) for AP1200 - minimum orderable quantity is 5 pcs. Part number 6090336 belongs to the Teledyne Gas and Flame Detection (Oldham) CPS Car Park System product line. List price $25.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111174 Lithium battery CR1/3
$20.00Lithium battery CR1/3. Part number 6111174 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $20.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111194 MX 52 Transformer
$485.00MX 52 Transformer. Part number 6111194 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $485.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111201 MX 48 Transformer
$552.00MX 48 Transformer. Part number 6111201 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $552.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111222 Uninterruptible Power Supply – RACK Mounting AES 24V 24A RACK, without battery, output 24V
$3,720.00Uninterruptible Power Supply - RACK Mounting AES 24V 24A RACK, without battery, output 24V - 24A, dimensions 483x132x358mm, weight 9kg. Part number 6111222 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $3,720.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111227 Battery PBE 12V 12Ah, dimensions 151x100x97,5mm, weight 4,1kg
$168.00Battery PBE 12V 12Ah, dimensions 151x100x97,5mm, weight 4,1kg. Part number 6111227 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $168.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111237 Power supply 230 Vac/ 24 Vdc 10A
$645.00Power supply 230 Vac/ 24 Vdc 10A. Part number 6111237 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 62 / MX62 TP product line. List price $645.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111240 Lithium Battery, 3.6V
$29.00Lithium Battery, 3.6V. Part number 6111240 belongs to the Teledyne Gas and Flame Detection (Oldham) Spare parts product line. List price $29.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111258 Battery PBE 12V 7Ah, dimensions 151x65x97,5mm, weight 2,65kg
$56.00Battery PBE 12V 7Ah, dimensions 151x65x97,5mm, weight 2,65kg. Part number 6111258 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $56.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111259 Battery PBE 12V 12Ah, dimensions 151x100x97,5mm, weight 4,1kg
$134.00Battery PBE 12V 12Ah, dimensions 151x100x97,5mm, weight 4,1kg. Part number 6111259 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $134.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111260 Battery PBE 12V 24Ah, dimensions 166x175x125mm, weight 9,7kg
$238.00Battery PBE 12V 24Ah, dimensions 166x175x125mm, weight 9,7kg. Part number 6111260 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $238.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111264 UNINTERRUPTIBLE POWER SUPPLY EV 24V 12A C48 AB 24Ah, supplied with battery, output 24V
$1,900.00UNINTERRUPTIBLE POWER SUPPLY EV 24V 12A C48 AB 24Ah, supplied with battery, output 24V - 12A, dimensions 425x315x120mm, weight 29kg. Part number 6111264 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $1,900.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111266 Battery PBE 12V 40Ah, dimensions 197x165x170mm, weight 14,5kg
$411.00Battery PBE 12V 40Ah, dimensions 197x165x170mm, weight 14,5kg. Part number 6111266 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $411.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics 6111267 CC-IG type converter 48V to 24V 7A, dimensions 125x240x112mm, weight 1,1kg
$555.00CC-IG type converter 48V to 24V 7A, dimensions 125x240x112mm, weight 1,1kg. Part number 6111267 belongs to the Teledyne Gas and Flame Detection (Oldham) Alarms and accessories product line. List price $555.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page.