Oldham Simtronics
Showing 1666–1710 of 2140 results
-

Oldham Simtronics GD10-P00-24BC-0XH-00 GD10P CO2, Carbon dioxide 5% Vol. (CH4, immune), SS 316L, ATEX
$3,845.00What is the Oldham Simtronics GD10-P00-24BC-0XH-00?The Oldham Simtronics GD10-P00-24BC-0XH-00 is: GD10P CO2, Carbon dioxide 5% Vol. (CH4, immune), SS 316L, ATEX, IECEx, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 5% Vol.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-24BC-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-24BG-0BH-00 GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, CSA
$4,655.00What is the Oldham Simtronics GD10-P00-24BG-0BH-00?The Oldham Simtronics GD10-P00-24BG-0BH-00 is: GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 100% Vol.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-24BG-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-24BG-0CH-00 GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, UL
$4,250.00What is the Oldham Simtronics GD10-P00-24BG-0CH-00?The Oldham Simtronics GD10-P00-24BG-0CH-00 is: GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, UL, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against UL approval, with the 4-20 mA current source output stage, covering 100% Vol.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-24BG-0CH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-24BG-0XH-00 GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, ATEX
$4,655.00What is the Oldham Simtronics GD10-P00-24BG-0XH-00?The Oldham Simtronics GD10-P00-24BG-0XH-00 is: GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, ATEX, IECEx, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 100% Vol.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-24BG-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-38DG-0BH-00 GD10P n-C4H10, n-Butane 100% LEL, SS 316L, CSA, 4-20mA, source
$3,325.00What is the Oldham Simtronics GD10-P00-38DG-0BH-00?The Oldham Simtronics GD10-P00-38DG-0BH-00 is: GD10P n-C4H10, n-Butane 100% LEL, SS 316L, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-38DG-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-38DG-0CH-00 GD10P n-C4H10, n-Butane 100% LEL, SS 316L, UL, 4-20mA, source
$3,095.00What is the Oldham Simtronics GD10-P00-38DG-0CH-00?The Oldham Simtronics GD10-P00-38DG-0CH-00 is: GD10P n-C4H10, n-Butane 100% LEL, SS 316L, UL, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against UL approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-38DG-0CH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-38DG-0XH-00 GD10P n-C4H10, n-Butane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source
$3,325.00What is the Oldham Simtronics GD10-P00-38DG-0XH-00?The Oldham Simtronics GD10-P00-38DG-0XH-00 is: GD10P n-C4H10, n-Butane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-38DG-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-38DG-0XJ-00 GD10P n-C4H10, n-Butane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, sink
$3,325.00What is the Oldham Simtronics GD10-P00-38DG-0XJ-00?The Oldham Simtronics GD10-P00-38DG-0XJ-00 is: GD10P n-C4H10, n-Butane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, sink. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current sink output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-38DG-0XJ-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-56DG-0BH-00 GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, CSA, 4-20mA, source
$4,060.00What is the Oldham Simtronics GD10-P00-56DG-0BH-00?The Oldham Simtronics GD10-P00-56DG-0BH-00 is: GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-56DG-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-56DG-0BJ-00 GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, CSA, 4-20mA, sink
$4,060.00What is the Oldham Simtronics GD10-P00-56DG-0BJ-00?The Oldham Simtronics GD10-P00-56DG-0BJ-00 is: GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, CSA, 4-20mA, sink. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current sink output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-56DG-0BJ-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-56DG-0CH-00 GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, UL, 4-20mA, source
$4,250.00What is the Oldham Simtronics GD10-P00-56DG-0CH-00?The Oldham Simtronics GD10-P00-56DG-0CH-00 is: GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, UL, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against UL approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-56DG-0CH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-56DG-0CJ-00 GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, UL, 4-20mA, sink
$4,250.00What is the Oldham Simtronics GD10-P00-56DG-0CJ-00?The Oldham Simtronics GD10-P00-56DG-0CJ-00 is: GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, UL, 4-20mA, sink. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against UL approval, with the 4-20 mA current sink output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-56DG-0CJ-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-56DG-0XH-00 GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, ATEX, IECEx
$4,060.00What is the Oldham Simtronics GD10-P00-56DG-0XH-00?The Oldham Simtronics GD10-P00-56DG-0XH-00 is: GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, ATEX, IECEx, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-56DG-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-56DG-0XJ-00 GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, ATEX, IECEx
$4,060.00What is the Oldham Simtronics GD10-P00-56DG-0XJ-00?The Oldham Simtronics GD10-P00-56DG-0XJ-00 is: GD10P C2H6, Ethane 100% LEL (2.4% Vol.), SS 316L, ATEX, IECEx, 4-20mA, sink. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current sink output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-56DG-0XJ-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-73DG-0BH-00 GD10P C6H12, Cyclohexane 100% LEL, SS 316L, CSA, 4-20mA, source
$5,460.00What is the Oldham Simtronics GD10-P00-73DG-0BH-00?The Oldham Simtronics GD10-P00-73DG-0BH-00 is: GD10P C6H12, Cyclohexane 100% LEL, SS 316L, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-73DG-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-73DG-0CH-00 GD10P C6H12, Cyclohexane 100% LEL, SS 316L, UL, 4-20mA, source
$4,945.00What is the Oldham Simtronics GD10-P00-73DG-0CH-00?The Oldham Simtronics GD10-P00-73DG-0CH-00 is: GD10P C6H12, Cyclohexane 100% LEL, SS 316L, UL, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against UL approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-73DG-0CH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-73DG-0XH-00 GD10P C6H12, Cyclohexane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA
$5,460.00What is the Oldham Simtronics GD10-P00-73DG-0XH-00?The Oldham Simtronics GD10-P00-73DG-0XH-00 is: GD10P C6H12, Cyclohexane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 100% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-73DG-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-80BG-0BH-00 GD10P C3H8, Propane 100% VOL. (CH4, immune), SS316, CSA, 4-20mA
$4,760.00What is the Oldham Simtronics GD10-P00-80BG-0BH-00?The Oldham Simtronics GD10-P00-80BG-0BH-00 is: GD10P C3H8, Propane 100% VOL. (CH4, immune), SS316, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316 stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 100% VOL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-80BG-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-80BG-0CH-00 GD10P C3H8, Propane 100% VOL. (CH4, immune), SS316, UL, 4-20mA, source
$4,945.00What is the Oldham Simtronics GD10-P00-80BG-0CH-00?The Oldham Simtronics GD10-P00-80BG-0CH-00 is: GD10P C3H8, Propane 100% VOL. (CH4, immune), SS316, UL, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316 stainless steel build, ordered against UL approval, with the 4-20 mA current source output stage, covering 100% VOL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-80BG-0CH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-80BG-0XH-00 GD10P C3H8, Propane 100% VOL. (CH4, immune), SS316, ATEX, IECEx
$4,760.00What is the Oldham Simtronics GD10-P00-80BG-0XH-00?The Oldham Simtronics GD10-P00-80BG-0XH-00 is: GD10P C3H8, Propane 100% VOL. (CH4, immune), SS316, ATEX, IECEx, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316 stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 100% VOL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-80BG-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-81BG-0BH-00 GD10P CH4, Methane 100% VOL. (HC immune), SS316, CSA, 4-20mA, source
$4,760.00What is the Oldham Simtronics GD10-P00-81BG-0BH-00?The Oldham Simtronics GD10-P00-81BG-0BH-00 is: GD10P CH4, Methane 100% VOL. (HC immune), SS316, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316 stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 100% VOL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-81BG-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-81BG-0CH-00 GD10P CH4, Methane 100% VOL. (HC immune), SS316, UL, 4-20mA, source
$4,945.00What is the Oldham Simtronics GD10-P00-81BG-0CH-00?The Oldham Simtronics GD10-P00-81BG-0CH-00 is: GD10P CH4, Methane 100% VOL. (HC immune), SS316, UL, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316 stainless steel build, ordered against UL approval, with the 4-20 mA current source output stage, covering 100% VOL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-81BG-0CH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-P00-81BG-0XH-00 GD10P CH4, Methane 100% VOL. (HC immune), SS316, ATEX, IECEx, 4-20mA
$4,760.00What is the Oldham Simtronics GD10-P00-81BG-0XH-00?The Oldham Simtronics GD10-P00-81BG-0XH-00 is: GD10P CH4, Methane 100% VOL. (HC immune), SS316, ATEX, IECEx, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316 stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 100% VOL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-P00-81BG-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-PE0-03AM-0BH-00 GD10PE C2H4, Ethylene 5,000 ppm, SS 316L, CSA, 4-20mA, source
$9,150.00What is the Oldham Simtronics GD10-PE0-03AM-0BH-00?The Oldham Simtronics GD10-PE0-03AM-0BH-00 is: GD10PE C2H4, Ethylene 5,000 ppm, SS 316L, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 5,000 ppm.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-PE0-03AM-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-PE0-03AM-0XH-00 GD10PE C2H4, Ethylene 5,000 ppm, SS 316L, ATEX, IECEx, INMETRO
$9,150.00What is the Oldham Simtronics GD10-PE0-03AM-0XH-00?The Oldham Simtronics GD10-PE0-03AM-0XH-00 is: GD10PE C2H4, Ethylene 5,000 ppm, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 5,000 ppm.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-PE0-03AM-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-PE0-17DE-0BH-00 GD10PE CH4, Methane 20% LEL, SS 316L, CSA, 4-20mA, source
$8,645.00What is the Oldham Simtronics GD10-PE0-17DE-0BH-00?The Oldham Simtronics GD10-PE0-17DE-0BH-00 is: GD10PE CH4, Methane 20% LEL, SS 316L, CSA, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current source output stage, covering 20% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-PE0-17DE-0BH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-PE0-17DE-0BJ-00 GD10PE Detector CH4 Methane 20% LEL, SS 316L, CSA, 4-20mA, sink
$8,645.00What is the Oldham Simtronics GD10-PE0-17DE-0BJ-00?The Oldham Simtronics GD10-PE0-17DE-0BJ-00 is: GD10PE Detector CH4 Methane 20% LEL, SS 316L, CSA, 4-20mA, sink. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against CSA approval, with the 4-20 mA current sink output stage, covering 20% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-PE0-17DE-0BJ-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-PE0-17DE-0XH-00 GD10PE CH4, Methane 20% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA
$8,645.00What is the Oldham Simtronics GD10-PE0-17DE-0XH-00?The Oldham Simtronics GD10-PE0-17DE-0XH-00 is: GD10PE CH4, Methane 20% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current source output stage, covering 20% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-PE0-17DE-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10-PE0-17DE-0XJ-00 GD10PE CH4, Methane 20% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA
$8,645.00What is the Oldham Simtronics GD10-PE0-17DE-0XJ-00?The Oldham Simtronics GD10-PE0-17DE-0XJ-00 is: GD10PE CH4, Methane 20% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, sink. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316L stainless steel build, ordered against ATEX approval, with the 4-20 mA current sink output stage, covering 20% LEL.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10-PE0-17DE-0XJ-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10P CO2 IR Point Gas Detector
The GD10P-CO2 uses state of the art IR gas measurement, to give a fast, reliable response. The GD10P has set the standard for gas detection in the areas of safety, stability and low maintenance. The GD10P comes wi th 5 years warranty The GD10P-CO2 has been designed with features that provide an effective response to the detection of CO2 in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations. The GD10P-CO2 differs from all other point infrared gas detectors, because they utilise silicon based solid-state sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. We offer the longest combined detector and IR source warranty on the market. Supplied with worldwide hazardous area approvals. Certified for use in SIL 2 system. An industry standard HART® interface is used for configuration of special fault levels as well as access to extended maintenance data. Features and benefits include an integral termination compartment for reduced installation time: the unit is ready out of the box, low power consumption which reduces load on UPS and independently heated mirror and lens for high performance detection in rough environmental conditions. Features Solid state IR sources (SimSourceTM) for superior long term performance compared to filament lamps No recalibration, monitors and accounts for all changes in optical path thanks to true dual path, double compensation optical design Selectable response rate Dual layer weather protector (No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand) Early dirty optics warning for improved preventative maintenance Technical data General: Detection method Ir-absorption, dual wavelength, dual path Ir-source Solid state ir source, 50hz flash Gases detected Co2 Self-test Continuous Calibration Factory set, no field recalibration Configuration Hart (response time, fault levels) Performance: Accuracy ±5% Fs between 0-50 % reading ±7% Fs between 50-80 % reading Response time Configurable T20 = 1 sec. (0.3 Sec) T50 = 2.5 Sec (0.7 Sec) T90 = 6 sec (1.6 Sec) Output signal: Standard Current source 4 – 20 mA, max. Load Impedance 500 ohm Option Current sink 4 – 20 mA HART® Maintenance and configuration Detector Faults (HART configurable) - Early clean optics - Dirty optics - Detector failure Configurable (HART) Pre warning (2 mA) Dirt accumulation (1 mA) Internal fault (0 mA) Electrical: Power supply 24V dc, range (18 - 32v dc) Power consumption Approx. 3.5 W Connection 3 Wires (0.5mm2- 2.5 mm2) Cable entry M20 exe cable gland Temperature range: Storage -40°C to + 70°c (-40°f to +158°F) Operating -40°C to + 60°C (-40°F to +140°F) Humidity (Operation) 100% RH Explosion proof housing: Protection category IP66/IP67 din 40050 Housing material Stainless steel sis2343 (astm316) Weight Approx. 2.9 Kg Dimensions (LxWxH) 251 X 1 04 x 1 05 (mm) 9.89 X 4.1 X 4.13 (Inches) Warranty: 5 Years full warranty on a complete instrument 15 Years warranty on the ir-sources Approvals: ATEX / IECEX / INMETRO II 2G Ex de IIC T6 Gb CSA Ex de IIC T6 (Canada only) Class I, Division 2, Groups A, B, C, and D (USA and Canada) Other SIL2 (Software SIL3), ABS, MED Versions: Standard ranges (volume) : 10000Ppm (1%) , 3%, 5% 10% and 100% The 0-100% volume is also compensated for Methane interference. Front cover: Required, select one - Weather protection For standard point detector - Sample flow housing For sampling systems and testing - Duct mount kit For through wall installation Accessories: Mosquito net Extra insect protection Sun shade Shielding for extreme radiation exposure Product Data Sheet -

Oldham Simtronics GD10P IR Point Gas Detector
The GD10P infrared gas detector is the market reference for combustible gas detection. It has set the standard for gas detectors in the areas of performance, response time, stability and low maintenance. GD10P comes with a 5 year warranty. The GD10P differs from all other infrared gas detectors because it uses a solid-state infrared source. The optical block is so robust that it comes with a 15 year warranty and provides an unparalleled detector stability and an unmatched service life. The GD10P also features heated optics to prevent condensation, a HART interface, fail-safe operation and global approvals. Features 5 years warranty 15 years warranty semiconductor IR source (Simtronics patent) Zero maintenance Response Time T90 < 1.0 s SIL 2 certified (SIL3 software) Early dirty optics warning for improved preventative maintenance Technical data General: Technology IR-absorption, dual wavelength, dual path IR-source Solid state IR source Gases detected Hydrocarbons (for CO2 see separate data sheet) Self-test Continuous Calibration Factory set, no field recalibration Configuration HART protocol Performance: Accuracy Refers to -20°c to +45°c ±3% FS between 0-50 % reading ±5% FS between 50-100 % reading Response time All gases T20 = 0,7 sec T50 = 1,7 sec T90 = 4 sec Output signal: Standard Current source 4 – 20 mA, max. Load Impedance 500 ohm Option Current sink 4 – 20 mA HART® Maintenance and configuration HART 7 Detector Faults (HART configurable) - Early clean optics - Dirty optics - Detector failure Pre warning 2 mA Dirt accumulation 1 mA Internal fault 0 mA Electrical: Power supply 24V DC (18 - 32V DC) Power consumption Approx. 3.5 W Connection 3-wire shielded cable (0.5-2.5mm²) Cable entry M20 Ex e cable gland Temperature range: Storage -40°C to +70°C (-40°F to +158°F) Operating -40°C to +60°C (-40°F to +140°F) Humidity (Operation) 0- 100% RH Explosion proof housing: Ingress Protection IP66/IP67 Housing material Stainless Steel SIS2343 (ASTM316) Weight Approx. 2.9 Kg Dimensions (LxWxH) 264 X 104 x 106 mm Warranty: 5 years full warranty on a complete instrument 15 years warranty on the infrared sources Approvals: ATEX / IECEx / INMETRO II 2 G / Ex db eb IIC T6 Gb CSA C22.2 No 152-M984 and ANSI 12.13.01-2000 Ex d e IIC T6 (for Canada only) Class I, Division 2, Groups A, B, C and D (USA and Canada) Various SIL 2 certified (software is SIL 3), ABS, MED Versions: Gas Ranges Methane 0-100%LEL, 0-100%vol Propane 0-100%LEL, 0-100%Vol Front cover: Required, select one Weather protection Supplied as standard Sample flow housing For sampling systems and bump test Duct mount kit For duct monitoring Accessories: Mosquito net Extra insect protection Sun shade Shielding for extreme solar radiation exposure or snow deposit Product Data Sheet -

Oldham Simtronics GD10P-DISPLAY-A-ATEX Field Mounted Loop Powered Indicator with Membrane Switches, Copper
$805.00What is the Oldham Simtronics GD10P-DISPLAY-A-ATEX?The Oldham Simtronics GD10P-DISPLAY-A-ATEX is: Field Mounted Loop Powered Indicator with Membrane Switches, Copper free Aluminum, Blue Epoxy Painted, ATEX, IECEx, IP68, 3xM20 entries, supplied with 1 stopping plug. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the aluminium build, ordered against ATEX approval.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10P-DISPLAY-A-ATEX on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10P-DISPLAY-A-CSA Field Mounted Loop Powered Indicator with Membrane Switches, Copper
$805.00What is the Oldham Simtronics GD10P-DISPLAY-A-CSA?The Oldham Simtronics GD10P-DISPLAY-A-CSA is: Field Mounted Loop Powered Indicator with Membrane Switches, Copper free Aluminum, Blue Epoxy Painted, CSA, NEMA4X, 3x3/4NPT entries, supplied with 1 stopping plug. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the aluminium build, ordered against CSA approval.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10P-DISPLAY-A-CSA on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10P-DISPLAY-X-ATEX Field Mounted Loop Powered Indicator with Membrane Switches
$1,000.00What is the Oldham Simtronics GD10P-DISPLAY-X-ATEX?The Oldham Simtronics GD10P-DISPLAY-X-ATEX is: Field Mounted Loop Powered Indicator with Membrane Switches, Stainless steel, ATEX, IECEx, IP68, 3xM20 entries, supplied with 1 stopping plug. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the stainless steel build, ordered against ATEX approval.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10P-DISPLAY-X-ATEX on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10P-DISPLAY-X-CSA Field Mounted Loop Powered Indicator with Membrane Switches, SS316
$1,000.00What is the Oldham Simtronics GD10P-DISPLAY-X-CSA?The Oldham Simtronics GD10P-DISPLAY-X-CSA is: Field Mounted Loop Powered Indicator with Membrane Switches, SS316, CSA, NEMA4X, 3x3/4NPT entries, supplied with 1 stopping plug. The GD10P and GD10PE are point gas detectors built on non dispersive infrared (NDIR) detection, using a solid state infrared source flashing at 32 Hz across a dual wavelength, dual path optical bench. Because detection is optical rather than chemical, the detector needs no oxygen to measure correctly and works in an inert gas atmosphere, cannot be poisoned by silicon vapours or hydrogen sulphide, is unaffected by gas velocity, and has no saturation effect, so it can read up to 100% volume. Calibration is factory set and no field recalibration is needed. The GD10PE is the version built for critical applications with large volumes of air at high velocity, where low gas concentrations must be caught quickly, such as HVAC and air generator intakes serving inhabited areas and gas turbine installations. The GD10P / GD10PE Point IR Gas Detectors group in the 2026 price book lists 157 orderable part numbers, and this one is the 316 stainless steel build, ordered against CSA approval.What are the specifications of the GD10P / GD10PE Point IR Gas Detectors?Detection method: infrared absorption, dual wavelength, dual path, with a solid state 32 Hz flash IR sourceGases detected: hydrocarbon gases and carbon dioxide; the target gas and scale are fixed by the ordered part numberAccuracy: plus or minus 3% of full scale between 0 and 50% of reading, plus or minus 5% between 50 and 100%Lifetime stability: plus or minus 5% of full scale readingResponse time: T20 0.7 s, T50 1.7 s, T90 4.0 s (fast option: 0.2 s, 0.4 s, 1.0 s)Start-up 65 s typical; 30 minutes warm up to full specification performanceOutput: 4-20 mA current source as standard, current sink as an option, maximum load impedance 500 ohmContinuous self-test, with dirty optics warning at 55% signal attenuation and dirty optics fault at 70%Suitable for use in SIL 2 and SIL 3 systems, with CSA, IECEx, ATEX and INMETRO approvalsGD10PE variant only: detection range 0-20% LEL (0-1% Vol.) methane; the GD10P target gas and scale are fixed by the ordered part numberWhat should you check before ordering?Teledyne guarantees parts and workmanship for 5 years and the infrared sources for 15 years, which is the figure behind the claim of the longest combined detector and IR source warranty on the market. That warranty is void if parts of unspecified origin are fitted, so a spare bought outside the vendor chain can cost the remaining source cover. The practical consequence of the NDIR bench is maintenance cost rather than performance: no chemical reaction means no poisoning by silicon vapours or hydrogen sulphide, and factory calibration means the detector is not on a recalibration schedule the way a catalytic bead point is.How do the part numbers differ?In this part numbering the output stage is selected by one character: H is the 4-20 mA current source version and J is the current sink version. Every complete description in the 2026 price book follows that rule without exception across 107 rows.Where is it used?Typical service: Fixed point combustible gas monitoring in boiler rooms and process areas; Offshore and onshore petrochemical installations; Inert or oxygen-free atmospheres where catalytic sensors cannot measure; HVAC and air generator intakes serving inhabited areas (GD10PE); High temperature areas of gas turbine installations (GD10PE).How do I order or get a quote?PE Energy supplies the Oldham Simtronics GD10P-DISPLAY-X-CSA on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the GD10P IR point gas detector already in our catalogue. -

Oldham Simtronics GD10PE IR Extended Point Gas Detector
The GD10PE is designed for critical applications involving large volumes of air with high velocity. In places where you need fast reliable detection of low gas concentrations. GD10PE is in a class of its own. The versatile GD10PE is suitable for monitoring, among others, the HVAC air intakes of living quarters, temporary refuges and local equipment rooms. In addition the ventilation air and combustion air intakes of gas turbines can be monitored along with the ventilation air extract duct, the only location where you can guarantee to detect a gas leak on a turbine package. With a measuring range of 0-20% LEL the GD10PE is 5 times more sensitive than standard point detectors. The GD10 range of infrared gas detectors differ from all other models, because they utilise si licon based solid-state infrared sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. An industry standard HART® interface is used for configuration of the levels as well as access to maintenance data. Features and benefits include an independently heated mirror and lens for high performance detection in rough environmental conditions and guaranteed continuous operations at 85°C which make this instrument suitable for turbine ventilation extract ducts. Features Solid state IR sources (SimSourceTM) for superior long term performance compared to filament lamps No recalibration, monitors and accounts for all changes in optical path thanks to true dual path, double compensation optical design Selectable response rate Dual layer weather protector (No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand) Early dirty optics warning for improved preventative maintenance Technical data General: Detection method Ir-absorption, dual wavelength, dual path Ir-source Solid state ir source, 50hz flash Detection range 0-20% Lel (0-1% vol. ) Methane Gases detected Hydrocarbons Self-test Continuous Calibration Factory set, no field recalibration Performance: Accuracy Refers to -20°c to +60°c (-4°f to +140°f) ±1,4% Lel full scale ±1% Lel (0-10% lel reading) ±1.4% Lel (10-20% lel reading) Response time Detector reading: 100% Lel test gas: 20% Lel test gas: T20 0.5 Sec. 0.8 Sec. T50 0.8 Sec. 2.1 Sec. T90 1.1 Sec. 5 Sec. Output signal: Standard Current source 4 – 20 mA, max. Load Impedance 500 ohm Option Current sink 4 – 20 mA HART® Maintenance and configuration Detector warnings: - Early clean optics - Dirty optics - Detector failure 2 mA 1 mA 0 mA Electrical: Power supply 24V DC, range (18 - 32V DC) Power consumption Approx. 3.5 W Connection 3 Wires (0.5mm2 - 2.5 mm2) Cable entry M20 exe cable gland Environment: Storage -40°C to + 70°c (-40°f to +158°f) Operating -40°C to + 60°C (-40°F to +140°F) Probe, inside duct Up to +85°c (185°f) Humidity (operation) 100% RH Explosion proof housing: Main compartment Exd IIC T6 Terminal comp. Exe Protection category IP66/IP67 din 40050 Housing material Stainless steel SIS2343 (ASTM316) Dimensions (lxwxh) 805x104x106 (mm) 31.7x4.1x4.2 (Inches) overall Weight (detector) Approx. 6.5 Kg (14.3 Lbs) Weather protection Approx. 0.3 Kg (0.7 Ibs) Duct mount kit Approx. 2. 1 Kg (4.6 Ibs) Warranty: 5 Years full warranty on a complete instrument 15 Years warranty on the IR-sources Approvals: ATEX / IECEX / INMETRO II 2 G EX db eb IIC T6 Gb CSA C22.2 No 152-M1984 and ANSI 12.13.01-2000 ex de IIC T6 (Canada) Class I, Division 2, groups A, B, C and D (US and Canada) Other SIL2 (Software SIL3), ABS, MED Versions: Gas Ranges Methane 0-20% LEL Ethylene 5,000 ppm Accessories: Weather protection Required for standard installation Sample flow housing For sampling systems and testing Duct mount kit For through wall installation Product Data Sheet -

Oldham Simtronics iTrans 2 Fixed Gas detector
$1,335.00Characteristics Large Sensor Offering – Electrochemical, Catalytic and Infrared Non-Intrusive Calibration Smart Sensor HART (optional) RS-485 Modbus Programmable Relays (optional) Dual Gas Sensing (optional) Features Oil and Gas Industry Offshore Drilling Utilities and Power Petrochemical Industry Water and Waste Treatment Food and Beverage Production Other features and benefits Dual Gas Sensing The iTrans 2 can detect and display up to two gases on certain models. Both gas sensors may be mounted directly to the transmitter, or may be mounted remotely Wide Sensor Offering The iTrans 2 supports Electrochemical, Catalytic Bead and Infrared sensors. The iTrans 2 is available for most common industrial gases, allowing of standardization for your gas detection equipment. Smart Sensors The iTrans 2‘s smart sensors come factory pre-calibrated and automatically send sensor information, such as sensor life, to the transmitter. A sensor life indicator is displayed immediately after each calibration. Dual-channel split-screen LED display For optimum visibility in dark places Non-Intrusive Calibration The iTrans 2‘s non-intrusive interface keys operate with a simple magnetic wand and allow for full transmitter configuration and calibration without opening the unit’s explosion-proof housing. Programmable Relays The microprocessor-controlled transmitters are capable of independent operation or multi-point system configuration. With optional on-board relays, the monitor has the added ability of stand-alone operation, activating alarms, horns or fans, and can also shut down a system without the need to wire back to a central control panel. Multiple Wiring Options The iTrans 2 can be configured to meet almost any installation application. Common configurations includes: 3-Wire (4-20mA) Models - Allow for full utilization of the iTrans 2‘s features and options and can be used with all of the iTrans 2‘s sensors. 4-Wire (Digital ModBus) Models - Allows for full utilization of the iTrans 2‘s features and options and can be used with all of the iTrans 2‘s sensors. HART™ Communication Protocol With the optional HART Communication Protocol, the iTrans 2 offers remote diagnostics, set-up or calibration by super - imposing a high-frequency current across the industry standard 4-20mA analog line. Stainless Steel Enclosure An optional stainless steel enclosure for corrosive environments Sensors The iTrans 2 is available with sensors for most common gases including: Infrared, CO2 , Catalytic Bead Combustible and electrochemical sensors. It can support simultaneous detection from two sensors, either directly attached to the display, or remote sensors. Versatile The iTrans 2 can be configured to meet nearly any application through its state-of-the art features and options. Explosion-proof HART (optional) RS-485 Modbus Stainless Steel Enclosure (optional) Programmable Relays (optional) 3-wire, 4-wire Installations Dual Gas Sensing (optional) Remote Sensing (optional) Large Sensor Offering – Electrochemical, Catalytic and Infrared Easy to use Smart Sensor Non-Intrusive Calibration Dual-channel split-screen LED display Ordering information: iTrans 2 offers a wide variety of sensor configurations and relay options for maximum flexibility and affordability. Use the following guide to select the options that best fit your monitoring needs and applications. Oldham recommends that a fixed system application survey be completed to help provide the most accurate assessment of your equipment requirements. iTrans 2 Base Part Number : iTrans 2-ABCDEFG (sensor options listed below) Magnetic calibration tool, and calibration cup are standard items with all iTrans 2 monitors. Accessories Part number Image code By-Pass / Flow-thru Kit P/N 77014579 a Splash guard / remote Cal Cup for Toxic, O2, and LEL P/N. 77015303 b iTrans 2 Calibration Wand P/N. 77024065 c iTrans 2 Splash guard P/N. 77023588 d iTrans 2 Calibration Cup P/N. 77023513 e Measuring ranges: Combustible Gases 0-100% LEL in 1% increments Hydrogen 0-999 ppm in 1 ppm increments Oxygen 0-30% by Volume in 0.1% increments Ammonia 0-500 ppm in 1 ppm increments Carbon Monoxide 0-999 ppm in 1 ppm increments Hydrogen Sulfide 0-500 ppm in 1 ppm increments Sulfur Dioxide 0.2-99.9 ppm in 0.1 ppm increments Hydrogen Cyanide 0.2-30 ppm in 0.1 ppm increments Hydrogen Chloride 0.2-30 ppm in 0.1 ppm increments Phosphine 0-1 ppm in 0.01 ppm increments Nitrogen Dioxide 0.2-99.9 ppm in 0.1 ppm increments Nitric Oxide 0-999 ppm in 1 ppm increments Chlorine 0.2-99.9 ppm in 0.1 ppm increments Chlorine Dioxide 0.02-1.00 ppm in 0.1 ppm increments Carbon Dioxide 0-100% by Volume in 1% increments Carbon Dioxide 0-0.5% by Volume in 0.01% increments Carbon Dioxide 0.2-30 ppm in 0.1 ppm increments Technical specifications: Sensors Combustible Gases: Catalytic Toxic / Oxygen: Electrochemical, Infrared (CO2) Warranty from date of shipment 2 years on electronics 3 years on infrared sensors (CO2) 2 years on catalytic (LEL), CO and H2S sensors 18 months on O2 sensors 12 months on other sensors Detected Gases See Ordering Guide Material Epoxy Coated Aluminium or 316 Stainless Steel Display Dual-channel split-screen LED display (4 digit, 7 segment arrangement per channel) provides simultaneous display of one or two gases. Input voltage 12-28VDC operating range (24VDC typical) Power Consumption 150mA@24VDC (Electrochemical sensor) 250mA@24VDC (Combustible gases catalytic) 0.8A peak (single gas) 170mA@24VDC (Infrared) 0.5A peak (single gas) 350mA@24VDC (Combined catalytic/Infrared) 1,2A peak (two gas) Ingress Protection NEMA 4X, IP66 Response Time (catalytic methane) T50: < 10 seconds T90: < 30 seconds Humidity Range 10-90% RH (non-condensing), typical Temperature range (sensor specific) -40°C to +75°C (-40°F to +167°F) Dimensions 127 x 153 x 129 mm (5.0” x 6.0” x 5.1”), 2.9 Kg (6.4 lbs) Cable 3-wire or 4-wire Maximum Cable Loop 15 Ohm (3-wire configs) 10 Ohm (4-wire configs) Output Signal Standard: 4-20mA (source) + RS-485 Modbus (9600 baud) Optional: HART Protocol Alarm relays (opt) 3 alarm relays (5 / Two user-programmable relays, SPST, N.O. Amps at 30VDC) Homologations Sensor Specific CCSAUS* One fault relay, SPST, N.C. Class I, Div 1, Groups B, C, D Ex d IIB + H2 T5 AEx d llB + H2T5 (1) Class I, Div 2, Groups A, B, C, D (2) ATEX and IECEx II 2G - Ex db IIB + H2 T5 Gb (1) NEPSI GYB15.1621X - Ex d IIB + H2 T5 Gb GB15322.1-2003 Fire protection INMETRO Ex db IIB+H2 T5 Gb(1) (1) Combustible gases, Hydrogen, Oxygen, Carbon Monoxide, Hydrogen Sulfide, Sulfur Dioxide, Hydrogen Cyanide, Phosphine, Nitrogen Dioxide, Nitric Oxide, Carbon Dioxide Product Data Sheet -

Oldham Simtronics L2M-8-24 Line monitoring module, 24Vdc, check the integrity of up to 8 lines from the relay contact to the actuator
$610.00Line monitoring module, 24Vdc, check the integrity of up to 8 lines from the relay contact to the actuator. Part number L2M-8-24 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 32v2 product line. List price $610.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics LT15 Test lamp for MultiFlame flame detector with charger (US/UK/AU adapters available
$8,900.00Test lamp for MultiFlame flame detector with charger (US/UK/AU adapters available. Part number LT15 belongs to the Teledyne Gas and Flame Detection (Simtronics) MultiFlame DF-TV7 product line. List price $8,900.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics MultiFlame DF-TV7 Optical Flame Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics M-4 MX 43 Wall mounted version, 4 lines
$2,325.00MX 43 Wall mounted version, 4 lines. Part number M-4 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 43 product line. List price $2,325.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics M-8 MX 43 Wall-mounted version, 8 lines
$3,465.00MX 43 Wall-mounted version, 8 lines. Part number M-8 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 43 product line. List price $3,465.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page. -

Oldham Simtronics MS1 0-100% LEL, ISO
$695.000-100% LEL, ISO. Part number MS1 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC(T) 100 product line. List price $695.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC(T) 100 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics MS2 0-100% LEL, IEC
$695.000-100% LEL, IEC. Part number MS2 belongs to the Teledyne Gas and Flame Detection (Oldham) OLC(T) 100 product line. List price $695.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLC(T) 100 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics MultiFlame DF-TV7 Optical Flame Detector
What is the Oldham Simtronics MultiFlame DF-TV7 Flame Detectors?The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, built around false alarm immunity and an intelligent optical self-test, in triple infrared and ultraviolet with double infrared versions. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.PE Energy lists 23 orderable part numbers from this family, each fixed at order for detection technology, approval scope and cable entry.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics MultiFlame DF-TV7 Flame Detectors on a quote basis: tell us the fire type, the area classification and the mounting, and we return the right part number with pricing and lead time. Every reference in this family is configured at order, so the part number carries the detection technology, the approval scope, the output and the cable entry. -

Oldham Simtronics MX16-0-000-0-0-0 MX16 controller, one analog (4-20mA) or digital input
$880.00MX16 controller, one analog (4-20mA) or digital input. Part number MX16-0-000-0-0-0 belongs to the Teledyne Gas and Flame Detection (Oldham) MX 16 product line. List price $880.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Oldham Simtronics products on the PE Energy Oldham Simtronics brand page.