Oldham Simtronics OLCT60D-IS- OLCT 60 – flameproof – with remote IS sensor
$2,510.00OLCT 60 - flameproof - with remote IS sensor. Part number OLCT60D-IS- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 60 product line. List price $2,510.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 60 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT60D-XP- OLCT 60 – flameproof – with remote XP sensor
$2,150.00OLCT 60 - flameproof - with remote XP sensor. Part number OLCT60D-XP- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 60 product line. List price $2,150.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 60 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT60D-XPA- OLCT 60 – flameproof – with remote poison resistant XP sensor
$2,280.00OLCT 60 - flameproof - with remote poison resistant XP sensor. Part number OLCT60D-XPA- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 60 product line. List price $2,280.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 60 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT60D-XPIR- OLCT 60 – flameproof – with remote XPIR sensor
$2,550.00OLCT 60 - flameproof - with remote XPIR sensor. Part number OLCT60D-XPIR- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 60 product line. List price $2,550.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 60 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-IS- OLCT 80 – flameproof – with on-board ISP sensor
$1,995.00OLCT 80 - flameproof - with on-board ISP sensor. Part number OLCT80-IS- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $1,995.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-W-IS- OLCT 80 – flameproof – Wireless 2,4GHz – with on-board ISP sensor
$5,680.00OLCT 80 - flameproof - Wireless 2,4GHz - with on-board ISP sensor. Part number OLCT80-W-IS- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $5,680.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-W-XP- OLCT 80 – flameproof – Wireless 2,4GHz – with on-board XP sensor
$5,370.00OLCT 80 - flameproof - Wireless 2,4GHz - with on-board XP sensor. Part number OLCT80-W-XP- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $5,370.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-W-XPA- OLCT 80 – flameproof – Wireless 2,4GHz – with on-board poison resistant XP sensor
$5,495.00OLCT 80 - flameproof - Wireless 2,4GHz - with on-board poison resistant XP sensor. Part number OLCT80-W-XPA- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $5,495.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-W-XPIR- OLCT 80 – flameproof – Wireless 2,4GHz – with on-board XPIR sensor
$6,410.00OLCT 80 - flameproof - Wireless 2,4GHz - with on-board XPIR sensor. Part number OLCT80-W-XPIR- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $6,410.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-XP- OLCT 80 – flameproof – with on-board XP sensor
$1,690.00OLCT 80 - flameproof - with on-board XP sensor. Part number OLCT80-XP- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $1,690.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-XPA- OLCT 80 – flameproof – with on-board poison resistant XP sensor
$1,805.00OLCT 80 - flameproof - with on-board poison resistant XP sensor. Part number OLCT80-XPA- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $1,805.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80-XPIR- OLCT 80 – flameproof – with on-board XPIR sensor
$2,720.00OLCT 80 - flameproof - with on-board XPIR sensor. Part number OLCT80-XPIR- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $2,720.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-IS- OLCT 80 – flameproof – with remote IS sensor
$2,795.00OLCT 80 - flameproof - with remote IS sensor. Part number OLCT80D-IS- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $2,795.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-W-IS- OLCT 80 – flameproof – Wireless 2,4GHz – with remote IS sensor
$6,130.00OLCT 80 - flameproof - Wireless 2,4GHz - with remote IS sensor. Part number OLCT80D-W-IS- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $6,130.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-W-XP- OLCT 80 – flameproof – Wireless 2,4GHz – with remote XP sensor
$5,805.00OLCT 80 - flameproof - Wireless 2,4GHz - with remote XP sensor. Part number OLCT80D-W-XP- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $5,805.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-W-XPA- OLCT 80 – flameproof – Wireless 2,4GHz – with remote poison resistant XP sensor
$5,905.00OLCT 80 - flameproof - Wireless 2,4GHz - with remote poison resistant XP sensor. Part number OLCT80D-W-XPA- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $5,905.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-W-XPIR- OLCT 80 – flameproof – Wireless 2,4GHz – with remote poison XPIR sensor
$6,745.00OLCT 80 - flameproof - Wireless 2,4GHz - with remote poison XPIR sensor. Part number OLCT80D-W-XPIR- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $6,745.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-XP- OLCT 80 – flameproof – with remote XP sensor
$2,455.00OLCT 80 - flameproof - with remote XP sensor. Part number OLCT80D-XP- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $2,455.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-XPA- OLCT 80 – flameproof – with remote poison resistant XP sensor
$2,575.00OLCT 80 - flameproof - with remote poison resistant XP sensor. Part number OLCT80D-XPA- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $2,575.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OLCT80D-XPIR- OLCT 80 – flameproof – with remote poison XPIR sensor
$3,370.00OLCT 80 - flameproof - with remote poison XPIR sensor. Part number OLCT80D-XPIR- belongs to the Teledyne Gas and Flame Detection (Oldham) OLCT 80 product line. List price $3,370.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics OLCT 80 Fixed Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics OPGD-794079 USB/RS485 Harness Converter Kit
$655.00What is the Oldham Simtronics OPGD-794079?The Oldham Simtronics OPGD-794079 is: USB/RS485 Harness Converter Kit. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-794079 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-799225 Pole Mount (U-Bolt 5 inch)
$750.00What is the Oldham Simtronics OPGD-799225?The Oldham Simtronics OPGD-799225 is: Pole Mount (U-Bolt 5 inch). The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-799225 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888257 Extended Commissioning Kit – includes universal connection harness
$3,420.00What is the Oldham Simtronics OPGD-888257?The Oldham Simtronics OPGD-888257 is: Extended Commissioning Kit - includes universal connection harness for Modbus® / HART® communication, check filters (Methane, Propane and Ethylene). The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888257 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-1 Function Check Filter Warning Level – Propane Calibration
$740.00What is the Oldham Simtronics OPGD-888260-1?The Oldham Simtronics OPGD-888260-1 is: Function Check Filter Warning Level - Propane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-1 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-2 Function Check Filter Alarm Level – Propane Calibration
$740.00What is the Oldham Simtronics OPGD-888260-2?The Oldham Simtronics OPGD-888260-2 is: Function Check Filter Alarm Level - Propane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-2 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-3 Function Check Filter Warning Level – Methane Calibration
$740.00What is the Oldham Simtronics OPGD-888260-3?The Oldham Simtronics OPGD-888260-3 is: Function Check Filter Warning Level - Methane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-3 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-4 Function Check Filter Alarm Level – Methane Calibration
$740.00What is the Oldham Simtronics OPGD-888260-4?The Oldham Simtronics OPGD-888260-4 is: Function Check Filter Alarm Level - Methane Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-4 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-5 Function Check Filter Warning Level – Ethylene Calibration
$740.00What is the Oldham Simtronics OPGD-888260-5?The Oldham Simtronics OPGD-888260-5 is: Function Check Filter Warning Level - Ethylene Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-5 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888260-6 Function Check Filter Alarm Level – Ethylene Calibration
$740.00What is the Oldham Simtronics OPGD-888260-6?The Oldham Simtronics OPGD-888260-6 is: Function Check Filter Alarm Level - Ethylene Calibration. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration.About the Quasar 900 Open Path Gas Detectors lineThis part is an accessory for the Quasar 900 Open Path Gas Detectors line. The specification below describes the detectors it is used with, not the accessory itself.Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888260-6 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888263 Sunshade, Stainless Steel
$445.00What is the Oldham Simtronics OPGD-888263?The Oldham Simtronics OPGD-888263 is: Sunshade, Stainless Steel. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and this one is the stainless steel build.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888263 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-888270 Tilt Mount (Stainless steel)
$535.00What is the Oldham Simtronics OPGD-888270?The Oldham Simtronics OPGD-888270 is: Tilt Mount (Stainless steel). The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and this one is the stainless steel build.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-888270 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-C-111 Quasar 901, 7-20 m, ATEX, M25
$18,365.00What is the Oldham Simtronics OPGD-901-C-111?The Oldham Simtronics OPGD-901-C-111 is: Quasar 901, 7-20 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-C-111 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-C-112 Quasar 901, 7-20 m, ATEX, ¾ NPT
$18,365.00What is the Oldham Simtronics OPGD-901-C-112?The Oldham Simtronics OPGD-901-C-112 is: Quasar 901, 7-20 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-C-112 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-F-111 Quasar 901, 7-20 m, FM, M25
$18,365.00What is the Oldham Simtronics OPGD-901-F-111?The Oldham Simtronics OPGD-901-F-111 is: Quasar 901, 7-20 m, FM, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-F-111 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-901-F-112 Quasar 901, 7-20 m, FM, ¾ NPT
$18,365.00What is the Oldham Simtronics OPGD-901-F-112?The Oldham Simtronics OPGD-901-F-112 is: Quasar 901, 7-20 m, FM, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-901-F-112 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-C-211 Quasar 902, 15-40 m, ATEX, M25
$18,365.00What is the Oldham Simtronics OPGD-902-C-211?The Oldham Simtronics OPGD-902-C-211 is: Quasar 902, 15-40 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-C-211 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-C-212 Quasar 902, 15-40 m, ATEX, ¾ NPT
$18,365.00What is the Oldham Simtronics OPGD-902-C-212?The Oldham Simtronics OPGD-902-C-212 is: Quasar 902, 15-40 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-C-212 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-F-211 Quasar 902, 15-40 m, FM, M25
$18,365.00What is the Oldham Simtronics OPGD-902-F-211?The Oldham Simtronics OPGD-902-F-211 is: Quasar 902, 15-40 m, FM, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-F-211 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-902-F-212 Quasar 902, 15-40 m, FM, ¾ NPT
$18,365.00What is the Oldham Simtronics OPGD-902-F-212?The Oldham Simtronics OPGD-902-F-212 is: Quasar 902, 15-40 m, FM, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-902-F-212 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-C-311 Quasar 903, 35-100 m, ATEX, M25
$18,365.00What is the Oldham Simtronics OPGD-903-C-311?The Oldham Simtronics OPGD-903-C-311 is: Quasar 903, 35-100 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-C-311 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-C-312 Quasar 903, 35-100 m, ATEX, ¾ NPT
$18,365.00What is the Oldham Simtronics OPGD-903-C-312?The Oldham Simtronics OPGD-903-C-312 is: Quasar 903, 35-100 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-C-312 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-F-311 Quasar 903, 35-100 m, FM, M25
$18,365.00What is the Oldham Simtronics OPGD-903-F-311?The Oldham Simtronics OPGD-903-F-311 is: Quasar 903, 35-100 m, FM, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-F-311 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-903-F-312 Quasar 903, 35-100 m, FM, ¾ NPT
$18,365.00What is the Oldham Simtronics OPGD-903-F-312?The Oldham Simtronics OPGD-903-F-312 is: Quasar 903, 35-100 m, FM, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against FM approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-903-F-312 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-904-C-411 Quasar 904, 80-200 m, ATEX, M25
$20,070.00What is the Oldham Simtronics OPGD-904-C-411?The Oldham Simtronics OPGD-904-C-411 is: Quasar 904, 80-200 m, ATEX, M25. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-904-C-411 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue. -

Oldham Simtronics OPGD-904-C-412 Quasar 904, 80-200 m, ATEX, ¾ NPT
$20,070.00What is the Oldham Simtronics OPGD-904-C-412?The Oldham Simtronics OPGD-904-C-412 is: Quasar 904, 80-200 m, ATEX, ¾ NPT. The SafEye Quasar 900 is an open path infrared detector for combustible gases. It works as an infrared transmitter and a receiver separated by 4 to 200 metres, measuring how much radiation the gas along that path absorbs and comparing it with the background absorption of the atmosphere. A single path can replace up to 20 point detectors. The unit is built for harsh sites: stainless steel construction, heated optics, IP66 and IP68 protection to NEMA 250 6P, and it keeps working through up to 95 percent obscuration caused by dust, fog, rain, snow or vibration. The Quasar 900 Open Path Gas Detectors group in the 2026 price book lists 27 orderable part numbers, and ordered against ATEX approval.What are the specifications of the Quasar 900 Open Path Gas Detectors?Detection method: open path infrared absorption across a transmitter and receiver pairGases detected: combustible gasesDetection range up to 200 metres, from 4 metres minimum separationTolerates up to 95 percent obscuration from dust, fog, rain, snow or vibrationOutputs: 4-20 mA, HART, RS485 Modbus RTU, plus built-in relaysPower supply 18 to 32 V DCHeated optics and stainless steel construction, IP66 and IP68, NEMA 250 6PSIL 2 certified by TUV RheinlandCertifications: CE, ATEX, IECEx, FMWhat should you check before ordering?The commercial case for an open path unit is the count it displaces: one Quasar 900 path covers ground that would otherwise need up to 20 point detectors, each with its own installation, cabling and test schedule. Response is under 3 seconds, with T90 under 10 seconds, and the published MTBF is a minimum of 100,000 hours, so a single path is a monitored point rather than a device that quietly stops answering. The housing is tested to MIL-STD-810C for humidity, salt fog, vibration and mechanical shock. Range is fixed by the model ordered rather than configured on site, and the four models in the 2026 price book step through 7-20 m, 15-40 m, 35-100 m and 80-200 m.How do the part numbers differ?Model number carries the range: Quasar 901 covers 7 to 20 m, 902 covers 15 to 40 m, 903 covers 35 to 100 m and 904 covers 80 to 200 m, each offered with ATEX or FM approval and with M25 or 3/4 inch NPT entries.Where is it used?Typical service: Perimeter monitoring of combustible gas across wide open areas; Replacing a line of point detectors along a process boundary; Sites with dust, fog, rain or snow that attenuate an optical path; Onshore and offshore hydrocarbon installations.How do I order or get a quote?PE Energy supplies the Oldham Simtronics OPGD-904-C-412 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the SafEye Quasar 900 open path combustible gas detector already in our catalogue.