Gas Detection
Showing 46–72 of 72 results
-
Oldham Simtronics OLCT10 Toxic Gas Detector
Designed for commercial applications, OLCT 10 detector perfectly suit the protection of equipment and personnel in presence of combustion and exhaust gases or refrigerants (freons) in ambient air. Rugged, small, easy to install and operate, these detectors combined with the MX 32 control unit meet demanding user requirements. Features: Electrochemical and semiconductor sensors 4-20 mA output signal Dust and humidity resistant (IP65) Fast and accurate response Up to 5 detectors on same line (CO, NO, NO2) Applications: Cold rooms Car parks Wiring of 1 OLCT 10 detector Wiring in parallel of 2 OLCT 10 detecting same gas (CO, NO or NO2) Wiring of 1 OLCT 10 SC (with a semi-conductor cell) Dimensions: Technical features: Electrochemical sensor Semiconductor sensor Range CO (0-300 ppm), NO (0-100 ppm), NO2 (0-30 ppm) R134a, R404a, R22, R410a etc. Signal output Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Normal operation 4-20mA (Fault < 0.5 mA or > 23.2 mA) Settings Without opening the enclosure by means of 2 potentiometers for zeroing and spanning 2 mA signal output in maintenance mode One dedicated connector to get a gas measurement Power Supply 15 to 30 Vdc (nominal 24 Vdc) 15 to 30 Vdc (nominal 24 Vdc) Consumption 30 mA max. 100 mA max. Cabling 2-wire, shielded, core size 0.9mm2 2 cable gland M16 (outer 4 to 8 mm) 3-wire, shielded, core size 0.9mm2 1 cable gland M16 (outer 4 to 8 mm) Dimensions (LxHxP) 118 x 126 x 63 mm 118 x 126 x 63 mm Material ABS ABS IP rating IP65 IP65 Expected Lifespan 24 to 48 month, depending gas to detect > 24 months Operating temperature -20 to +55°C -20 to +55°C Operating humidity 15% HR to 90% HR 20% HR to 90% HR Pressure range 1 bar ± 10 % 1 bar ± 10 % Response Time NO2: T90 < 60s, NO : T90 < 120 CO : T50 < 15s, Fréon R134A : T50 < 30s Certification Electromagnetic compatibility according to EN 50270:2015 (type2) Complies with EN 14624 for freon Product Data Sheet -
Spectrex SafEye 300 Duct Open Path Detector
The SafEye 300 Duct Open Path Detectors monitor ingress of hazardous flammable gas concentrations into air intakes of turbine engines and HVAC air ducts. Duct applications require that the small path across an air inlet responds with a very high sensitivity, full scale of 1 LEL.m for 2-6.6ft (0.6-2m) wide inlet and full scale of 2.5 LEL.m for 6.6-23ft (2-7m) wide inlet. Features High Sensitivity Alarm up to 0.5 LEL.m 5 times more sensitive than the normal Open Path equipment Fast Response Fast response time of typically 2 sec., max. 5 sec. 5 to 10 times faster than the commonly used Open Path detector and 20-50 times faster than the Point Detector. Low Maintenance High reliability, simple installation, alignment, and maintenance, equipment not subject to poisoning. Proven Technology Used in air ducts on FPSO’s and offshore rigs for British Petroleum (BP), Shell, and ABB Lummus for turbines, air intakes, etc. Harsh Environment Specially designed to perform under extreme conditions such as high-speed airflows, high temperatures (up to 185˚F (85˚ C)), humidity, and corrosive gases, where point detectors may not be effective. Standard Interface Options Standard 4-20 mA outputs or RS-485 output to allow networking (up to 64 detectors) to a central monitoring/PC system. This feature also enables easy maintenance and local and remote diagnostic tools. Typical Applications Offshore Oil & Gas Rigs and FPSOs; Onshore Oil & Gas Terminals; Storage Farms and Filling Stations; Petrochemical and Chemical Industries; Power Utilities and Turbines areas; Automotive, Painting, Printing, Pharmaceutical Industries, and many more. Specific applications include: HVAC ducts (Heating Ventilation Air Conditioning) in accommodations areas Air ducts in process areas Stacks and exhaust towers Compressors and generators enclosures Curing ovens and drying equipment, printing equipment Engine & Turbine air intake and exhaust Air intake to safety enclosures Paint-booths and paint production and drying processes Air ventilation shafts Specifications General Specifications Detected Gases Simultaneous detection of C1-C8 flammable gases Detection Range and Response Time Model 301 Distance 2-11.5ft (0.6-3.5m) Response Time Typically 2 sec., max. 5 sec. Immunity to False Alarm Not influenced by solar radiation, hydrocarbon flames, other external IR radiation sources, high airflows and high loaded streams Spectral Response 3.0-4.0 µm Sensitivity Range 0-2.5 LEL.m Standard; 0-1 LEL.m by software Misalignment Tolerance ±2˚ Drift Long-term ±5% of full scale Temperature Range -40˚F (-40˚C) to 185˚F (85˚ C) Electrical Specifications Power Supply 24 VDC (18-32 VDC) Power Consumption Detector: 200mA @ 24 VDC (250 mA Peak) Source: 250mA @ 24 VDC (450 mA Peak) Electrical Connection 2 x 3/4'' - 14NPT conduits Electrical Input Protection According to MIL-STD-1275B Electromagnetic Compatibility EMI/RFI protected CE Marked Outputs 0-20mA Sink (source option) configuration Maximum load 600Ω at 18-32V DC 4-20mA Gas reading 4mA Normal, zero reading 2mA Obscuration/misalignment /beam block 1mA Zero calibration mode 0mA Fault HART Protocol HART communications on the 0-20mA analog current (FSK)- used for maintenance, configuration changes and asset management RS-485 The RS-485 input/output provides complete data information to a PC and receives control commands from the PC or handheld unit Relays Type Normal Position Maximum Ratings Alarm SPDT NO, NC 2A at 30V DC Accessory SPST Open 2A at 30V DC Fault SPST Closed 2A at 30V DC Mechanical Specifications Dimensions 5.2" (132mm) x 5.2" (132mm) x max. 4.7" (120mm) Weight Al. Encl. Detector: max 8.7 lb (3.7 kg) Source: max 8.58 lb (3.9 kg) Mechanical Design The standard detector housing is heavy-duty, copper-free (less than 1%) aluminum. The housing is finished in white epoxy enamel Environmental Standards Designed to meet MIL-STD-810C for Humidity, Salt & Fog, Vibration, Mechanical shock, High Temp, Low Temp Water and Dust Tight IP66 and 67 per EN60529 NEMA 250 6P Hazardous Area Approvals FM Class I, Division 1, Groups B, C and D, Dust Ignition proof for Class II, Division 1, Groups E, F and G. Performance per Class no. 6325 Reliability SIL2 per IEC61508 (TUV) Product Data Sheet -
Spectrex SafEye Quasar 900 Open Path Combustible Gas Detector
The SafEye Quasar 900 is part of the innovative SafEye Quasar open path gas detector series. The detector provides continuous infrared technology monitoring for combustible hydrocarbon gases at very low concentrations, up to 95 percent obscuration, featuring advanced wide area coverage with long range detection at up to 660 ft. (200 m) and high-speed response in under three seconds. The SafEye Quasar 900 ensures reliable and accurate protection to keep a SafEye on your safety. Features and benefits Detects combustible hydrocarbon gases, including alkanes (methane to hexane) and ethylene at up to 660 ft. (200 m) Accurate and reliable high-speed response in under three seconds Uses infrared technology High false alarm immunity Built-in event recorder; record of the last 256 events Strengthened reliability and durability with a massive three-year warranty Easy installation and maintenance Heated window for operation in harsh weather conditions (snow, ice, or condensation) Detection of a cloud of gas at very low concentrations, up to 95 percent obscuration User programmable via HART® 7 or RS-485 Modbus®; compatible with modern user interface for ease of use Certified performance/Hazardous Area approved (FM, ATEX, IECEx, CSA, and more) for location in Zone 1 areas and 3rd party performance approved (FM, DNV) Approved to Safety Integrity Level 2 (SIL2 - TÜV) High reliability-MTBF-minimum 100,000 hours Applications Offshore platforms and FPSOs Petrochemical plants Chemical Gas filling and distribution terminals Gas transport and pipelines Large storage areas and buildings Perimeter monitoring Product Data Sheet -
Spectrex SafEye Quasar 950 Open Path H2S Gas Detector
The SafEye Quasar 900 is part of the innovative SafEye Quasar open path gas detector series. The detector provides continuous infrared technology monitoring for combustible hydrocarbon gases at very low concentrations, up to 95 percent obscuration, featuring advanced wide area coverage with long range detection at up to 660 ft. (200 m) and high-speed response in under three seconds. The SafEye Quasar 900 ensures reliable and accurate protection to keep a SafEye on your safety. Features and benefits Detects combustible hydrocarbon gases, including alkanes (methane to hexane) and ethylene at up to 660 ft. (200 m) Accurate and reliable high-speed response in under three seconds Uses infrared technology High false alarm immunity Built-in event recorder; record of the last 256 events Strengthened reliability and durability with a massive three-year warranty Easy installation and maintenance Heated window for operation in harsh weather conditions (snow, ice, or condensation) Detection of a cloud of gas at very low concentrations, up to 95 percent obscuration User programmable via HART® 7 or RS-485 Modbus®; compatible with modern user interface for ease of use Certified performance/Hazardous Area approved (FM, ATEX, IECEx, CSA, and more) for location in Zone 1 areas and 3rd party performance approved (FM, DNV) Approved to Safety Integrity Level 2 (SIL2 - TÜV) High reliability-MTBF-minimum 100,000 hours Applications Offshore platforms and FPSOs Petrochemical plants Chemical Gas filling and distribution terminals Gas transport and pipelines Large storage areas and buildings Perimeter monitoring Product Data Sheet -
Spectrex SafEye Quasar 960 Open Path NH3 Gas Detector
The SafEye Quasar 960 is part of he innovative SafEye Quasar open path gas detector series. The detector provides ultraviolet technology continuous monitoring for toxic ammonia (NH3) gas at very low concentrations, up to 95 percent obscuration, featuring advanced wide area coverage with long range detection up to 200 ft. (60 m) and high speed response in under 10 seconds. The SafEye Quasar 960 is solar blind and immune to industrial environments, ensuring reliable and accurate protection to keep a SafEye on your safety. Features and benefits Detects toxic ammonia (NH3) at up to 200 ft. (60 m) Accurate and reliable high-speed response in under 10 seconds Uses ultraviolet technology High false alarm immunity Solar blind and immune to industrial environments Strengthened reliability and durability with a massive three-year warranty Easy installation and maintenance Heated window for operation in harsh weather conditions (snow, ice, or condensation) Detection of a cloud of gas at very low concentrations, up to 95 percent obscuration User programmable via HART® 7 or RS-485 Modbus®; compatible with modern user interface for ease of use Certified performance/Hazardous Area approved (FM, ATEX, IECEx, CSA, and more) for location in Zone 1 areas and 3rd party performance approved (FM, DNV) Approved to Safety Integrity Level 2 (SIL2 - TÜV) High reliability-MTBF-minimum 100,000 hours Applications Agriculture Food and beverage Chemical Waste management Water treatment Pharmaceutical Product Data Sheet -
Teledyne 8800 Controller – Multichannel Gas And Flame Monitoring System
The 8800 controller combines the reliability of our proven 7800 controller with advanced upgrades in one low cost package. The 8800 controller provides simultaneous display and alarm functions for up to 16 input variables. 8 or 16 channel display modes, and I/O modules arranged in groups of 8 channels, allow economical configuration of systems. This easy-to-configure, user friendly controller is ideal for centralizing display and alarm functions in critical multipoint monitoring applications. Features 8/16 channel display modes accept inputs from many sensor types and signal ranges. Input types include 4-20mA and Modbus Ethernet with Modbus TCP serves/client and web server for configuration and monitoring RS-485 serial ports allow simultaneous Modbus Master/Slave operation. Two standard ports and two optional isolated ports Three independent alarm levels per channel. “Relay Acknowledge” feature allows silencing of external audible devices during alarm conditions QVGA Color LCD displays monitored data as trends, bar graphs and engineering units. Readouts change colors to indicate alarms Five standard SPDT 5-amp alarm relays. HORN, FAULT and three programmable alarm relays Options cards such as 4-20mA inputs, 4-20mA outputs, discrete and programmable alarm relays Cal Mode offers push-button zero/span calibration for remote sensor applications Authorization Mode allows locking of critical settings Data Logger onto SD card allows recording of input values, and events for more than 10 years Power supply options include both 150 and 600 Watt Magnetic keypad standard for non-intrusive operation in potentially hazardous locations Enclosures include wall mount NEMA 4X - Non- Metallic, 316 SS, XP and Rack/Panel Mount 8800 Controller Input 12 bit 4-20mA into 150 ohms input impedance; includes +power supply terminals for each channel for routing power to two or three wire transmitters Serial Ports Two standard RS485 ports Two additional isolated ports optional Ethernet Port Modbus TCP Master/Slave port with web server (Gateway for Ethernet IP, Bacnet, and other protocols available) Alarm Relays 5 amp 30VDC or 250VAC resistive Form C Analog Outputs (Optional) 16 bit 4-20mA output. Max load 800 ohms with nominal 24VDC power supply Alarm Reset Two 10-60VDC Alarm Reset Input Terminals Digital Output 400mA @ VDC Display QVGA 320 x 240 pixel TFT graphic LCD with LED backlight Ambient Temperature Range -25 – +60 degrees C Power Supply 10 – 30VDC (24VDC nominal) 12 Watts max required 10-0172 option = 150 Watt 10-0307 option = 600 Watt Approvals CE Approved CSA C22.2 No 1010.1 and C22.2 No.152 for combustibles and ISA S82.02 CSA Class I Div 2 Grps A, B, C, D MAIN DATA SCREEN Displays all active channels on the same screen. Channel configurations include 16, active channels. Cells indicate alarm status by color. BAR GRAPH SCREEN Displays 16 channels at a time. Bar graphs change colors to indicate alarm status. 24 HOUR TREND SCREEN Displays 1 channel at a time as most recent 24 hour trend. Top data fields include current reading, max – min – average readings over the 24 hours, range, channel ID and engineering units. COMBINATION SCREEN Displays 1 channel at a time as most recent 30-minute trend, bar graph and large engineering units. Top data fields include current reading, max - min -average readings for trouble shooting, range, channel ID, and engineering units. Readings change color and flash on alarms. Flashing color becomes steady after acknowledge. ZONE SCREEN Displays all eight possible active zones. Alarm cells change colors and name field flashes indicating alarms. Allows user direct access to screen that shows which channels belong to each zone. Product Data Sheet -
Teledyne 8864 Controller – Multichannel Gas And Flame Monitoring System
The 8864 controller provides simultaneous display and alarm functions for up to 64 input variables. 16, 32, 48, and 64 channel display modes, and I/O modules arranged in groups of 16 channels, allow economical configuration of systems. This easy-to-configure, user friendly controller is ideal for centralizing display and alarm functions in critical multipoint monitoring applications. The similarity in function and user interface between the 8864 and the 16 channel 8800 makes usage of this family of controllers straightforward where both are used. Features 16, 32, 48, & 64 channel display modes accept inputs from many sensor types and signal ranges. Input types include 4-20mA, Modbus, and wireless options. Ethernet with Modbus TCP serves/client and web server for configuration and monitoring RS-485 serial ports allow simultaneous Modbus Master/ Slave operation. Two standard ports and two optional isolated ports Three independent alarm levels per channel. “Relay Acknowledge” feature allows silencing of external audible devices during alarm conditions QVGA Color LCD displays monitored data as trends, bar graphs and engineering units. Readouts change colors to indicate alarms CSA certified for Division 2 potentially hazardous areas Five standard SPDT 5-amp alarm relays. HORN, FAULT and three programmable alarm relays Options cards such as 4-20mA inputs, 4-20mA outputs, discrete and programmable alarm relays and bridge sensor inputs Cal Mode offers push-button zero/span calibration for remote sensor applications Authorization Mode allows locking of critical settings Data Logger onto SD card allows recording of minimum, maximum, and average values for one year Power supply options include both 150 and 600 Watt Magnetic keypad standard for non-intrusive operation in potentially hazardous locations Enclosures include wall mount NEMA 4X - Non- Metallic, 316 SS, XP and Rack/Panel Mount 8864 Controller Input 12 bit 4-20mA into 150 ohms input impedance; includes +power supply terminals for each channel for routing power to two or three wire transmitters Serial Ports Modbus Master and Slave RS485 ports equipped with Tx / Rx LEDs Ethernet Port Modbus TCP Master/Slave port with web server (Gateway for Ethernet IP, Bacnet, and other protocols available) Alarm Relays 5 amp 30VDC or 250VAC resistive Form C Analog Outputs (Optional) 16 bit 4-20mA output. Max load 800 ohms with nominal 24VDC power supply Bridge Inputs (Optional) 12 bit, 16 channel bridge input Display QVGA 320 x 240 pixel TFT graphic LCD with LED backlight5 LEDs show standard relay alarm status Ambient Temperature Range -25 – +60 degrees C Power Supply 10 – 30VDC (24VDC nominal) 12 Watts max required 10-0172 option = 150 Watt 10-0307 option = 600 Watt Approvals CSA C22.2 No 1010.1 and C22.2 No.152 for combustibles and ISA S82.02 UL 1604 / C22.2 No 213 (NEMA 4X = Division 2 Groups A,B,C,D,) EN55011 and EN61000 (CE Mark) MAIN DATA SCREEN Displays all active channels on the same screen. Channel configurations include 16, active channels. Cells indicate alarm status by color. BAR GRAPH SCREEN Displays 16 channels at a time. Bar graphs change colors to indicate alarm status. 24 HOUR TREND SCREEN Displays 1 channel at a time as most recent 24 hour trend. Top data fields include current reading, max – min – average readings over the 24 hours, range, channel ID and engineering units. COMBINATION SCREEN Displays 1 channel at a time as most recent 30-minute trend, bar graph and large engineering units. Top data fields include current reading, max - min -average readings for trouble shooting, range, channel ID, and engineering units. Readings change color and flash on alarms. Flashing color becomes steady after acknowledge. ZONE SCREEN Displays all eight possible active zones. Alarm cells change colors and name field flashes indicating alarms. Allows user direct access to screen that shows which channels belong to each zone. Product Data Sheet -
Teledyne Detcon DM-700 Toxic Gas Detector
Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port APPLICATIONS: Oil & Gas Chemical Plants Food & Beverage Steel Mills Pulp and Paper Refineries Wastewater Treatment Plants Utilities PART NUMBER GAS MEASURING ACCURACY RESPONSE TIME 967-12EG91-100 Acetylene 0-100 ppm ±2% FS T90≤140 seconds 967-505091-100 Ammonia 0-100 ppm ±2% FS T90≤90 seconds 967-191991-001 Arsine 0-1 ppm ±2% FS T90≤60 seconds 967-747591-005 Bromine 0-5 ppm ±2% FS T90≤60 seconds 967-12EB91-100 Butadiene 0-100 ppm ±2% FS T90≤140 seconds 967-444491-100 Carbon Monoxide 0-100 ppm ±2% FS T50≤10 sec./ T90≤30 sec. 967-747491-010 Chlorine 0-10 ppm ±2% FS T90≤60 seconds 967-747691-050 Chlorine Dioxide 700 0-50 ppm ±2% FS T90≤120 seconds 967-777791-001 Chlorine Dioxide 701 0-1 ppm ±2% FS T90≤60 seconds 967-192191-005 Diborane 0-5 ppm ±2% FS T90≤60 seconds 967-12EO91-100 Ethanol 0-100 ppm ±2% FS T90≤140 seconds 967-12ED91-100 Ethylene (*See Note 2) 0-100 ppm ±2% FS T90≤140 seconds 967-12EJ91-100 Ethylene Oxide 0-100 ppm ±2% FS T90≤140 seconds 967-272791-001 Fluorine 0-1 ppm ±2% FS T90≤80 seconds 967-12EP91-100 Formaldehyde 0-100 ppm ±2% FS T90≤140 seconds 967-232591-002 Germane 0-2 ppm ±2% FS T90≤60 seconds 967-070791-01P Hydrogen (1%) 0-1% volume ±2% FS T90≤60 seconds 967-050591-04P Hydrogen (4%) 0-4% ±2% FS T90≤60 seconds 967-848491-100 Hydrogen PPM 0-100 ppm ±2% FS T90≤30 seconds 967-090891-030 Hydrogen Bromide 0-30 ppm ±2% FS T90≤70 seconds 967-090991-030 Hydrogen Chloride 0-30 ppm ±2% FS T90≤70 seconds 967-131391-030 Hydrogen Cyanide 0-30 ppm ±2% FS T90≤40 seconds 967-333391-010 Hydrogen Fluoride 0-10 ppm ±2% FS T90≤90 seconds 967-242491-100 Hydrogen Sulfide 0-100 ppm ±2% FS T50≤10 sec./ T80≤30 sec. 967-303091-100 Hydrogen Sulfide (DC)* 0-100 ppm ±10% applied gas concentration or ±3 ppm, whichever is greater T20 ≤ 20sec 967-303091-050 T50 ≤ 45 sec 967-303091-025 T90 ≤ 60 sec 967-12EE91-100 Methanol 0-100 ppm ±2% FS T90≤140 seconds 967-12EK91-100 Methyl Mercaptan 0-100 ppm ±2% FS T90≤45 seconds 967-949491-100 Nitric Oxide 0-100 ppm ±2% FS T90≤10 seconds 967-646491-010 Nitrogen Dioxide 0-10 ppm ±2% FS T90≤40 seconds 967-341520-025 Oxygen 0-25% volume ±1% FS T90≤10 seconds 967-393991-001 Ozone 0-1 ppm ±2% FS T90≤120 seconds 967-192091-005 Phosphine 0-5 ppm ±2% FS T90≤30 seconds 967-232391-050 Silane 0-50 ppm ±2% FS T90≤60 seconds 967-555591-020 Sulfur Dioxide 0-20 ppm ±2% FS T90≤20 seconds *Note: Acetylene can only be used with a Group A enclosure. *Note2: This product is a safety device to detect hazardous conditions, and is not intended for process control application in fruit ripening operations. *Note3: DC=Desert Climate Sensors are 3rd-party test report to ISA 92.00.01 2010 standard SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption 3-electrode electrochemical cell Plug-in field replaceable Intelligent Type Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CCSAUS Class I, Division 1, Groups B, C, D () Class I, Zone 1, Group IIC ATEX II 2 G Ex d ib IIB + H2 T4 GB Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUS ATEX CE Marking SIL2 Certified to IEC 61508 MECHANICAL SPECIFICATIONS: Dimensions 7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5"; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11 - 30 VDC Power Consumption Normal operation = 30mA @ 24V (<0.75 watt) Maximum = 50mA @ 24V (1.2 watts) Inrush Current 500mA @ 24V (typical) RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600, N, 8, 1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over -voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon DM-700-O2 Oxygen Sensor
Model DM-700-O2 is a non-intrusive "Smart" sensor designed to detect and monitor Oxygen in air over the range of 0-25% by volume using electrochemical sensor technology. The plug-in, field replaceable sensor cell is temperature compensated and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), and HART. Detcon’s oxygen sensors have a long shelf life and are supported by an industry-leading warranty. Order Guide Specify junction box options (below) PN 967-343490-25P_ - DM-700-O2 Sensor Assembly (no junction box) PN 967-343491-25P_ - DM-700-O2 Sensor Assembly with Aluminum J-Box PN 967-343494-25P_ - DM-700-O2 Sensor Assembly with 316 SS J-Box APPLICATIONS: Petrochemical Refineries Chemical plants Confined Space Monitoring Analyzer Shelters Wastewater treatment plants Wet wells-dry wells Pulp and paper Food and beverage Utilities FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption 3-electrode electrochemical cell Plug-in field replaceable Intelligent Type Sensor Life 2 1/2 to 3 years typical Measurement Range 0-25% Oxygen by volume Accuracy/Repeatability ±1% FS Response/Clearing Time T90 ≤ 10 seconds Span Drift <5% of signal per year (in first two years) Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C) Class I, Zone 1, Group IIC ATEX II 2 G Ex d ib IIB + H2 T4 Gb (Tamb = -40°C to +50°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUSA ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in Cell - 2 years; Transmitter - 2 Years Environmental Specifications Operating Temperature Range -40°F to +122°F; -40°C to +50°C Storage Temperature Range -40°F to +122°F; -40°C to +50°C Operating Humidity Range 0-99% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/ aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 30mA (<0.75 watt) Maximum = 50mA (1.2 watts) Inrush Current 1.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Wireless Integration Module (Detcon Model RXT-320 SmartWireless® Transceivers) Product Data Sheet -
Teledyne Detcon FP-524D Combustible Gas Sensor
Model FP-524D is a "Smart" gas detection sensor designed to detect and monitor combustible gas in air over the range of 0-100% LEL (lower explosive limit) using matched-pair catalytic bead technology. Model FP-524D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon matched-pair catalytic bead sensors dating back more than 20 years. The sensor assembly includes the detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups C and D). Model FP-524D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault and calibration status. A HART communications option is also available. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty Order Guide PN 965-525420-100 - Model FP-524D in Aluminum Junction Box PN 965-52542B-100 - Model FP-524D-316SS in Stainless Steel Junction Box PN 9H5-525420-100 - Model FP-524D with HART in Aluminum Junction Box PN 9H5-52542B-100 - Model FP-524D-316SS with HART in Stainless Steel Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Certified to ISA performance standards cCSAus approved for for Class I, Division 1, Groups C & D Transmitter design fits all existing Detcon Catalytic Bead Sensors dating back 20 years Simple menu driven calibration - less than 3 minutes LED display and LED indicators for FAULT and CAL status Plug-in field-replaceable transmitter Long sensor life: average +5 years in harsh offshore drilling/production environments High resistance to poisons such as sulfides, chlorides, silicon-based contaminants etc. Low power consumption (less than 3.5 watts versus 8+ watts on competitive brands) Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Matched-pair catalytic bead Sensor Life 3 to 5 years typical Measurement Range 0-100% LEL (lower explosive limit) Accuracy/Repeatability ±3% 0-50% LEL ±5% 50-100% LEL Response/Clearing Time T50 <10 seconds; T90 <30 seconds Zero Drift <5% per year Outputs Linear 4-20 mA DC HART (optional) Electrical Classification Explosion proof CSAus Class I, Division 1, Groups C, D (Tamb = -25°C to +40°C) Class I, Zone 1, Group IIB cCSA Class I, Division 1, Groups C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB Performance Approvals CSA C22.2 #152-M1984, ISA 12.13.01-2003 Safety Approvals cCSAus Ingress Protection NEMA 4X, IP66 Warranty Sensor: 2 year warranty Transmitter: 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -40°C to +75°C; -40°F to +167°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10"H (including splashguard) x 6.1"W x 4.3"D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5"; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 87mA (2 watts) RFI/EMI Protection Complies with ISO 92.0.01 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators 4-digital LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Faults Monitored Loop, Input Voltage, Zero Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon FP-624D Combustible Gas Sensor
Model FP-624D is a “Smart” gas detection sensor designed to detect and monitor combustible gas in air over the range of 0-100% LEL (lower explosive limit) using matched-pair catalytic bead technology. Model FP-624D features Detcon’s MicroSafeTM intelligent electronics, nonintrusiveoperator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon matched-pair catalytic bead sensors dating back more than 20 years. The sensor assembly includes the detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups C & D). Model FP-624D is equiped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, 2 alarm relays and 1 fault relay, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault, alarm, and calibration status. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty. Order Guide Specify junction box options (below) PN 966-524520-100 - Model FP-624D in Aluminum Junction Box PN 966-52452B-100 - Model FP-624D-316SS in Stainless Steel Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Performance Certified to CSA 152 cCSAus for Class I, Division 1, Groups C & D Transmitter design fits all existing Detcon Catalytic Bead Sensors dating back 20 years Compatible with PLCs, SCADA, DCS, via 4-20 mA, and/or RS485, and/or alarm relays Sensor status and parameters accessible via RS-485 (Modbus™) Menu programmable relays standard (two alarms plus fault) Simple menu driven calibration - less than 3 minutes LED display and LED indicators for FAULT and CAL status Plug-in field-replaceable transmitter Long sensor life: averaging +5 years in harsh offshore drilling/production environments High resistance to poisons such as sulfides, chlorides, silicon-based contaminants etc. Low power consumption (less than 3.5 watts versus 8+ watts on competitive brands) Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Matched-pair catalytic bead Sensor Life 3 to 5 years typical Measurement Range 0-100% LEL (lower explosive limit) Accuracy/Repeatability ±3% 0-50% LEL ±5% 50-100% LEL Response/Clearing Time T50 <10 seconds; T90 <30 seconds Zero Drift <5% per year Outputs Linear 4-20 mA DC HART (optional) 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Electrical Classification Explosion proof CSAus Class I, Division 1, Groups C, D (Tamb = -25°C to +40°C) Class I, Zone 1, Group IIB cCSA Class I, Division 1, Groups C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB Performance Approvals CSA C22.2 #152 Safety Approvals cCSAus Ingress Protection NEMA 4X, IP66 Warranty Sensor: 2 year warranty Transmitter: 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -40°C to +75°C; -40°F to +167°F Operating Humidity Range 0-99% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12 - 28 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 87mA (2 watts) RFI/EMI Protection Complies with ISO 92.0.01 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators 4-digital LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Relay Outputs Alarm 1, Alarm 2, and Fault 5A @ 250VAC 5A @ 30VDC Faults Monitored Loop, Input Voltage, Zero Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon FP-700 Combustible Gas Sensor
Model FP-700 is a non-intrusive "Smart" sensor designed to detect and monitor combustible gases in air over the range of 0-100% LEL using catalytic bead sensor technology. The plug-in, field replaceable detector is poison-resistant and features over-sized gold-plated connections that help prevent corrosion. The FP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model FP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model FP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), and HART. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty. Order Guide Specify junction box options (below) PN 967-525520-100 - FP-700 Sensor Assembly (no junction box) PN 967-521520-100 - FP-700 Sensor Assembly with Aluminum Junction Box PN 967-524520-100 - FP-700 Sensor Assembly with 316 SS Junction Box PN 9H7-521520-100 - FP-700 Sensor Assembly with HART in Aluminum Junction Box PN 9H7-524520-100 - FP-700 Sensor Assembly with HART in 316 SS Junction Box PN 9R7-524520-100 - FP-700 Sensor Assembly with RAM in Aluminum Junction Box PN 9R7-524520-100 - FP-700 Sensor Assembly with HART in 316SS Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Matched-pair catalytic bead detector Plug-in field replaceable Sensor Life 3 to 5 years typical Measurement Range 0-100% LEL (lower explosive limit) Accuracy/Repeatability ±3% 0-50% LEL; ±5% 50-100% LEL Response/Clearing Time T50 <10 seconds; T90 <30 seconds Zero Drift <5% per year Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CCSAUS Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSUS Performance to ANSI/ISA 60079-29-1 (12.13.01)-2013 and CSA 22.2 #152 ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in detector - 2 years Transmitter - 2 Years Environmental Specifications Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-99% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 1.0A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Operating Temperature, Loop, Input Voltage, Bridge Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Wireless Integration Module (Detcon Model RXT-320 SmartWireless® Transceivers Product Data Sheet -
Teledyne Detcon IR-700-CH Combustible Gas Sensor
Model IR-700-CH is a non-intrusive “Smart” sensor designed to detect and monitor combustible hydrocarbon gases in air over the range of 0-100% LEL using miniature non-dispersive Infrared Optical (NDIR) sensor technology. As compared to catalytic bead sensors, with NDIR there is no risk of sensor poisoning, no risk of high concentration saturation, and no need for O2 to be present. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The IR-700-CH’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CH is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR-700-CH is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 5-year warranty. Order Guide Specify junction box options (below) PN 967-215520-100 - IR-700-CH Sensor Assembly (no junction box) PN 967-211520-100 - IR-700-CH Sensor Assembly with Aluminum Junction Box PN 967-214520-100 - IR-700-CH Sensor Assembly with 316 SS Junction Box PN 9H7-211520-100 - IR-700-CH Sensor Assembly with HART, Alumium Junction Box PN 9H7-214520-100 - IR-700-CH Sensor Assembly with HART, 316 SS Junction Box PN 9R7-211520-100 - IR-700-CH Sensor Assembly with RAM, Aluminum Junction Box PN 9R7-214520-100 - IR-700-CH Sensor Assembly with RAM, 316 SS Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Offshore Production Platforms FPSOs LNG/CNG Plants Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants GAS DETECTED: Methane Ethane Propane Butane Pentane Hexane Ethylene Gasoline Vapor Diesel Fuel Vapor Jet Fuel Vapor For other gases consult the factory FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release Sensor Endcap (Allen Wrench only required) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Non-dispersive Infrared Optical (NDIR) - Combustible Gas Sub-miniature plug-in field replaceable Sensor Life 5 years typical Measurement Range 0-100% LEL (lower explosive limit) 0-100% by volume Accuracy ±2% F.S. (0-50% LEL) Repeatability ±2% F.S. Response Time* T50 < 6 seconds, T90 < 10 seconds Zero Drift (typical) ≤2% per 2 years Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals CCSAUS Performance to ISA 12.13.01-2000 and CSA 22.2 #152 ATEX CE Marking SIL2 Certified to IEC 61508 (ATEX version only) Warranty Plug-in detector - 5 years Transmitter - 2 Years * As tested with 1 lpm flowrate ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 0.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) HART Integration Module (HART Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon IR-700-CO2 Carbon Dioxide Sensor
Model IR-700-CO2 is a non-intrusive “Smart” sensor designed to detect and monitor carbon dioxide gas in air using miniature non-dispersive Infrared Optical (NDIR) sensor technology. Available in a low and a high range version, ranges of detection (by volume) are 0-0.3%, 0-1%, 0-3%, 0-5% (low range version) and 0-10%, 0-25%, 0-50%, and 0-100% (high range version). The plug-in, field replaceable detector provides a selective response to CO2 and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CO2 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR700-CO2 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Additional integration options include a Remote Alarm Module (RAM) & HART. Detcon’s carbon dioxide gas sensor has an infinite shelf life and is supported by a 5-year pro-rated warranty. Order Guide Specify junction box options (below) PN 967-405520-005 - IR-700-CO2 (5% Range) Sensor Assembly (no J-box) PN 967-401520-005 - IR-700-CO2 (5% Range) Sensor Assembly with Aluminum J-Box PN 967-404520-005 - IR-700-CO2 (5% Range) Sensor Assembly with 316 SS J-Box PN 967-425520-025 - IR-700-CO2 (25% Range) Sensor Assembly (no J-box) PN 967-421520-025 - IR-700-CO2 (25% Range) Sensor Assembly with Aluminum J-Box PN 967-424520-025 - IR-700-CO2 (25% Range) Sensor Assembly with 316 SS J-Box APPLICATIONS: Chemicals Pesticides Agriculture & Horticulture Food & Beverage Bottling Plants Sewer Entry Waste Water Treatment Plants Coal Gasification Pulp & Paper Mills Enhanced Oil Recovery FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry I/O Protection Water-Resistant, Corrosion-Resistant, Vibration-Resistant Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Non-dispersive Infrared Optical (NDIR) - CO2 Sub-miniature plug-in field replaceable Sensor Life 5 years typical Measurement Range (% by volume) 0-0.3, 0-0.5, 0-1, 0-3, 0-5 (low range version) 0-10, 0-15, 0-20, 0-25, 0-50, 0-100 (high range version) Accuracy/Repeatability ±5% of range Response Time T50 < 15 seconds, T90 < 40 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus ATEX CE Marking Warranty Plug-in detector - 5 year pro-rated Transmitter - 2 Years ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -40°F to +167°F; -40°C to +75°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 0.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon Model 100 Toxic Gas Sensor
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality. Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty APPLICATIONS: Oil and Gas Chemical Plants Food and Beverage Steel Mills Pulp and Paper Refineries Waste Water Treatment Plants Utilities FEATURES: XP-intrinsically Safe Class I, Div. 1, Groups B, C & D 2 Wire Loop powered Field Replaceable Electrochemical Sensor Non-intrusive Magnetic Interface Built-in Diagnostics Fully Encapsulated ITM Electronics Electropolished 316SS Construction ITM Quick Thread Release (for sensor replacement) Integral Calibration Port PART NUMBER GAS MEASURING ACCURACY RESPONSE TIME 961-500022-100 Ammonia 0-100 ppm ±2% FS T90≤90 seconds 961-190022-001 Arsine 0-1 ppm ±2% FS T90≤60 seconds 961-750022-005 Bromine 0-5 ppm ±2% FS T90≤60 seconds 961-EB0022-100 Butadiene 0-100 ppm ±2% FS T90≤140 seconds 961-440022-100 Carbon Monoxide 0-100 ppm ±2% FS T50≤10 sec./ T90≤30 sec. 961-740022-010 Chlorine 0-10 ppm ±2% FS T90≤60 seconds 961-760022-050 Chlorine Dioxide 700 0-50 ppm ±2% FS T90≤120 seconds 961-770022-001 Chlorine Dioxide 701 0-1 ppm ±2% FS T90≤60 seconds 961-210022-005 Diborane 0-5 ppm ±2% FS T90≤60 seconds 961-EO0022-100 Ethanol 0-100 ppm ±2% FS T90≤140 seconds 961-ED0022-100 Ethylene (*See Note 2) 0-100 ppm ±2% FS T90≤140 seconds 961-EJ0022-100 Ethylene Oxide 0-100 ppm ±2% FS T90≤140 seconds 961-270022-001 Fluorine 0-1 ppm ±2% FS T90≤80 seconds 961-EP0022-100 Formaldehyde 0-100 ppm ±2% FS T90≤140 seconds 961-250022-002 Germane 0-2 ppm ±2% FS T90≤60 seconds 961-070022-01P Hydrogen (1%) 0-1% volume ±2% FS T90≤60 seconds 961-840022-100 Hydrogen PPM 0-100 ppm ±2% FS T90≤30 seconds 961-080022-030 Hydrogen Bromide 0-30 ppm ±2% FS T90≤70 seconds 961-090022-030 Hydrogen Chloride 0-30 ppm ±2% FS T90≤70 seconds 961-130022-030 Hydrogen Cyanide 0-30 ppm ±2% FS T90≤40 seconds 961-330022-010 Hydrogen Fluoride 0-10 ppm ±2% FS T90≤90 seconds 961-240022-100 Hydrogen Sulfide 0-100 ppm ±2% FS T50≤10 sec./ T80≤30 sec. 961-EE0022-100 Methanol 0-100 ppm ±2% FS T90≤140 seconds 961-EK0022-100 Methyl Mercaptan 0-100 ppm ±2% FS T90≤45 seconds 961-940022-100 Nitric Oxide 0-100 ppm ±2% FS T90≤10 seconds 961-640022-010 Nitrogen Dioxide 0-10 ppm ±2% FS T90≤40 seconds 961-340022-025 Oxygen 0-25% volume ±1% FS T90≤10 seconds 961-390022-001 Ozone 0-1 ppm ±2% FS T90≤120 seconds 961-200022-005 Phosphine 0-5 ppm ±2% FS T90≤30 seconds 961-230022-050 Silane 0-50 ppm ±2% FS T90≤60 seconds 961-550022-020 Sulfur Dioxide 0-20 ppm ±2% FS T90≤20 seconds *Note2: This product is a safety device to detect hazardous conditions, and is not intended for process control application in fruit ripening operations. SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption 2-electrode electrochemical cell Plug-in field replaceable Type Span Drift <5% signal loss per year (in first 2 years) Outputs Linear 4-20 mA DC Electrical Classification Explosion proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C) Safety Approvals cCSAus Sensor Life/Warranty See sensor detail table above for specific sensor warranty ENVIRONMENTAL SPECIFICATIONS: Operating Temperature Range Refer to chart on prior page per gas type. Storage Temperature Range Refer to chart on prior page per gas type. Operating Humidity Range 0% to 99% RH non-condensing (continuous) 0%-100% RH (intermittent) Operating Pressure Range Atmospheric ±10% ACCESSORIES: Junction Box (aluminum with Transient Protection Terminal Board) Loop Powered Digital Display (Provides a Direct Display of Sensor Readings) MECHANICAL SPECIFICATIONS: Dimensions 7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5"; 140mm center to center Weight 2 lbs; 0.907 kg (sensor only) 6 lbs; 2.72 kg (w/aluminum j-box) 9 lbs; 4.08 kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11 - 30 VDC Power Consumption Normal operation = 30mA @ 24V (<0.75 watt) Maximum = 50mA @ 24V (1.2 watts) Inrush Current 500mA @ 24V (typical) Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators Optional 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over -voltage, Miswiring Product Data Sheet -
Teledyne Detcon Model 1000 Carbon Dioxide Analyzer
Detcon Model 1000-CO2 Analyzer is designed to provide continuous, accurate, real-time measurement of carbon dioxide gas concentrations in a wide variety of process gas streams. Available ranges are from 0-1.0% up to 0-15.0%. All CO2 analyzers in the Model 1000 Series employ Detcon’s sub-miniature NDIR optical sensor element and feature a microprocessor-based signal-conditioning transmitter with local digital display, fault supervision, calibration mode indicator, 4-20mA, alarm relays and an RS-485 serial port. The instrument package is rated for Non-Hazardous areas. APPLICATIONS: Continuous Measurement with Superior Uptime Readily Field Replaceable Sensors Simple Operation and Field Calibraton Standard Outputs: 4-20 mA, RS-485, 3 Relays FEATURES: Ranges from 1%, 3%, 5% and 15% by Volume Readily Field Replaceable Sensors Simple Operation and Field Calibraton Standard Outputs: 4-20 mA, RS-485, 3 Relays Non-Hazardous area rated Sensor Type Non-dispersive Infrared Measurement Range - High Range 0-1.0/3.0/5.0/15.0% Accuracy/Repeatability The greater of: ±10% of reading or ±2.5% of range Response/Clearing Time T50 <30 seconds T80 <60 seconds Operating Temperature Range -40°F to +167°F; -40°C to +75°C Operating Pressure Requirements Inlet: 10 ±2 psig Vent: Atmospheric ±1 psig Outputs Linear 4-20 mA DC RS-485 Modbus™ 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Power Input 117/220 VAC 18-36 VDC Electrical Classification Non-Hazardous areas Warranty Sensor: 2 years Transmitter: 2 years Analyzer Weight 80 lbs. Shipping Weight 140 lbs Dimensions 29” x 29” x 8” Product Data Sheet -
Teledyne Detcon Model 1000 Hydrogen Sulfide Analyzer
Model 1000-H2S Analyzer is designed to provide continuous, accurate, real-time measurement of hydrogen sulfide gas concentrations in a wide variety of process gas streams. With new technology and design, the Process Analyzer has a measurement range of 0-500 ppm. All H2 S analyzers in the Model 1000 Series employ Detcon’s 3-Electrode Electrochemical sensor element and feature a microprocessor-based signal-conditioning transmitter with local digital display, fault supervision, calibration mode indicator, 4-20mA, alarm relays and an RS-485 serial port. The lowest range for this unit is 0-10 ppm. The instrument package is rated for Non-Hazardous areas. APPLICATIONS: Gas Well Testing & Analysis Gas Well Production Sites Gas Treatment Plants Gas Transmission Custody Transfer Compliance FEATURES: Continuous Measurement with Superior Uptime Ranges from 0-500 ppm Readily Field Replaceable Sensors Simple Operation and Field Calibraton Standard Outputs: 4-20 mA, RS-485, 3 Relays Non-Hazardous Areas rated Sensor Type 3-Electrode Electrochemical Measurement Range Low Range 0-10/20/50/100/150/250/500 ppm Accuracy/Repeatability ±10% of reading or ±2.5% of range whichever is greater Response/Clearing Time T50 <30 seconds T90 <1 minute Max output to over-range gas: <10 seconds Operating Temperature Range -40°F to +122°F; -40°C to +50°C Operating Pressure Requirements Inlet: 10 ±2 psig Vent: Atmospheric ±1 psig Outputs Linear 4-20 mA DC RS-485 Modbus™ 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Power Input 117/220 VAC 18-36 VDC Electrical Classification Non-Hazardous Areas Warranty Sensor: 6 months Transmitter: 2 year Analyzer Weight 80 lbs. Shipping Weight 140 lbs Dimensions 29" x 29" x 8" Product Data Sheet -
Teledyne Detcon Model X40 Integrated Alarm And Control System
Model X40 is a low power alarm and control system designed to monitor multiple gas detection sensors and/or a wide range of other field devices. The versatile control system is designed to receive and supervise inputs using either 4-20mA DC or Serial RS-485 Modbus™ and is available in two packages: Model X40-8 and Model X40-32. Both packages function as a Modbus™ Master and can be customized and expanded based on individual application needs using the stackable din-rail mounted I/O modules. All I/O modules are individually addressable and operate on 11.5-30VDC. The X40-8 provides power for up to eight field devices and can house up to six 4-channel I/O modules. The Model X40-32 provides power for up to 32 field devices and can house up to 12 4-channel I/O modules. The I/O modules available for use with the Model X40 include a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). The modules can be mounted within the main system enclosure or installed remotely to simplify field wiring. The Model X40 is completely field programmable using a small handheld magnet and offers advanced technology with intuitive, embedded intelligence. The control system displays real-time readings and field device status on a backlit LCD screen. During normal operation, the screen displays the alarm status and current reading (i.e., channel number, gas type, and gas concentration) for up to eight field devices simultaneously. The display is sequential and during normal operation it auto cycles through each of the active channel screens. Among the system’s unique features is a wireless option that can be used with RXT-320 SmartWireless® transceivers. Enclosure options include: NEMA 4X, NEMA 1 panel mount, and NEMA 7. Features 8 to 32 channel capacity Backlit LCD screen display Analog or RS-485 input options Easy intuitive field configuration Wire or distributed I/O Extensive event data logging SmartWireless® capable Applications Oil and gas drilling rigs Oil and gas production sites Offshore production platforms Wastewater treatment plants Food and beverage processing Pulp and paper mills Refining and petrochemical SYSTEM SPECIFICATIONS System Capacity Model X40-32-N1P: Up to 32 field devices Model X40-8-N4X: Up to 8 field devices Model X40-32-N4X: Up to 32 field devices Model X40-32-N7: Up to 32 field devices (analog or serial) Indicators 1 1/8” by 5 3/4” backlit LCD Alarm status LEDs Display Accuracy ±1% of full scale value Input Options Analog 4-20 mA DC RS-485 Modbus™ *(Only compatible with other Detcon products) Relay Contacts Output Options 4-20 mA DC RS-485 Modbus™ Relay Contacts Safety Approvals CE Marking (Models X40-N4X & X40-SS) Warranty One Year ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -4ºF to + 158ºF, -20ºC to + 70ºC Storage Temperature Range -40ºF to + 185ºF, -40ºC to + 85ºC Operating Humidity Range 0-99% RH non-condensing MECHANICAL SPECIFICATIONS Dimensions Model X40-32-N1P: 10.5”W x 8”H x 12”D Model X40-8-N4X: 12”W x 14”H x 7.75”D Model X40-32-N4X: 16”W x 17.85”H x 9.5”D Model X40-32-N7: 11”W x 9.15”H x 2.75”D Weight Model X40-32-N1P: 10 lbs Model X40-8-N4X: 10 lbs Model X40-32-N4X: 20 lbs Model X40-32-N7: 10 lbs ELECTRICAL OPTIONS Power Input 115-230 VAC* or 11.5-30 VDC * Option for Model X40-32-N7 Power Consumption <0.25 Watt (I/O module power consumption not included) (Field device power consumption not included) Electrical Classification Model X40-32-N1P: NEMA 1 Panel Mount Model X40-8-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N7: NEMA 7 Class I; Division 1, Group C, D Order Guide PN 95P-X32000-000 Model X40-32-N1P, General purpose panel mount hardware assembly 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 954-X08000-000 Model X40-8-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 8 active channels). PN 954-X32000-000 Model X40-32-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 957-X32000-000 Model X40-32-N7, Div 1 weatherproof enclosure 24 VDC power* for use in distributed I/O installations only (up to 32 active channels). Product Data Sheet -
Teledyne Detcon OLCT 700 / 710 Fixed Gas Detection
Model Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% encapsulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The gas detector sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Model Series OLCT 700/710 intelligent sensor modules feature dual outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output. It is becoming increasingly important that safety systems meet the Safety Integrity Level (SIL) requirements of IEC 61508 and IEC 61511. The SIL rating can only be determined by considering the complete safety system. FEATURES: 316 SS Construction IP 66 Multi-Layer Surge Protection SIL2 Certified Environmentally Bulletproof Series OLCT 700/710 The SERIES OLCT 700/710 sensor modules are designed with this in mind and feature a new and unmatched level of pre-emptive fault diagnostics. Application variables like input voltage range, operating temperature range, maintenance schedule, detector reliability and output integrity are all monitored and reported via the 4-20 mA and RS-485 serial output. As a component of a SIL rated system, the Safe Failure Fraction (SFF) of SERIES OLCT 700/710 sensors are designed to meet the requirements for any SIL 2 rated system. SERIES OLCT 700's sensors utilize distinctive gas detection technologies to satisfy a wide range of industrial applications that require monitoring of, toxic and flammable gases. Sensors for Hydrogen Sulfide CHEMFET MOS Solid State Technology Harsh and Extreme Locations Wide Temperature & Humidity Range 5-year Sensor Warranty Sensors for Combustible Gas Catalytic Technology Non-selective Combustible Gas Sensor 2-year Sensor Warranty Rugged Construction Infrared Technology Combustible Hydrocarbon Gas Sensor 2-year Sensor Warranty Sensors for Carbon Dioxide Infrared Technology Selective CO2 Gas Sensor 2-year Sensor Warranty Scrolling Full Message/Text Display ANATOMY of the OLCT 700/710 SPECIFICATIONS: Combustible Hydrocarbon & Carbon Dioxide Gas Detectors Model OLCT 700/710 IR Gas Combustible Hydrocarbons or CO2 Range 0-100 % LEL* or 0-5% vol.* CO2 Temperature -40°C to +75°C Warranty 2 years on electronics, 2 years on sensor *Standard Range Hydrogen Sulfide Gas Detector (solid state metal oxide semiconductor) Model OLCT 700/710 TP Gas / Symbol Hydrogen Sulfide/H2S Range 0-20 ppm, 0-50 ppm, 0-100 ppm*, 0-200 ppm Temperature -40°C to +75°C Warranty 2 years on electronics, 5 years on sensor Combustible Gas Detector (matched pair catalytic bead) Model OLCT 700/710 FP Gas / Symbol Combustible Gas Range 0-100 % LEL Temperature -40°C to +75°C Warranty 2 years on electronics, 2 years on sensor OLCT 700 OLCT 710 Input Voltage 11.5 - 28 VDC standard Power Consumption < 2 watts typical Outputs Linear 4-20 mA DC RS - 485 ModbusTM RTU Dimensions 178mm (7") Height x 65mm (2.2") Ø 349mm (13.74") Height x 127 mm (5") Width x 130 mm (5.12") Depth Weight 1.14 kg (2.5 lbs) Aluminun 3,36 kg (7.40 lbs) Stainless steel version 7.44 kg (16.40 lbs) Approvals ATEX II 2G Ex d IIB+H2 T4 Gb Functional Safety SIL2 as per IEC 61508 (except CO2) Performance Approvals OLCT 700 IR, OLCT 700 FP to ISA 12.13, CSA #152 Accuracy / Repeatability OLCT 700/710 FP and IR: ±3% LEL 0-50% LEL; ±5% LEL 50-100% LEL OLCT 700 TP: ±10% of reading or ±2 ppm (greater of) OLCT 700 IR-CO2 : ±5% full scale Response / Clearing Time OLCT 700/710 FP and IR-CH: T50 <10 s; T90 <30s (respectively 6s and 10s as tested with 1 LPM flow rate) OLCT 700 TP: T50 <30 s; T80 <60 s OLCT 700 IR-CO2 : T50 <15 s; T90 <40 s Operating Humidity Range (Continuous) OLCT 700 FP: 0-99% RH non-condensing OLCT 700 TP: 15-100% RH non-condensing OLCT 700 IR: 0-99% RH non-condensing Product Data Sheet -
Teledyne Detcon PI-700 Universal VOC Gas Sensor
Model PI-700 is a non-intrusive “Smart” sensor that use photo-ionization detector technology to monitor VOC gases over ranges from 0-10 ppm to 0-5,000 ppm. In the PI-700 sensor design, Detcon has successfully converted the sensitive laboratory style PID technology into a rugged, environmentally insensitive, and long-life industrial gas sensor. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The PI-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model PI-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model PI-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s PID sensors have a long shelf life and are supported by an industry leading warranty. Order Guide Specify junction box options (below) PN 967-P15520-010 - PI-700-VOC Sensor Assembly (no junction box) PN 967-P11520-010 - PI-700-VOC Sensor Assembly with Aluminum Junction Box PN 967-P14520-010 - PI-700-VOC Sensor Assembly with 316 SS Junction Box PN 967-P25520-01K - PI-701-VOC Sensor Assembly (no junction box) PN 967-P21520-01K - PI-701-VOC Sensor Assembly with Aluminum Junction Box PN 967-P24520-01K - PI-701-VOC Sensor Assembly with 316 SS Junction Box PN 967-P15520-0X5 - PI-700-VOC Special Low Range Sensor Assembly with 316 SS Junction Box APPLICATIONS: Pharmaceutical industry Power plants Chemical industry Air quality Refineries and petrochemical plants Solvent recovery systems Waste water treatment plants Marine and off-shore oil wells Pulp and paper industry Painting and coating operations FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-Proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption Photo Ionization Detector (PID) Plug-in replaceable intelligent type (with replacement lamp) Sensor Life 2 years typical Measurement Range Gas Dependent, ranges as low as 0-10 ppm or as high as 0-5,000ppm (consult Detcon) Accuracy/Repeatability ±10% of reading or ±2% of range (greater of ) Response Time T50 <30 seconds; T90 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -20°C to +50°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d ib IIB + H2 T4 Gb (Tamb = -20°C to +50°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus ATEX CE Marking Warranty PLUG-IN DETECTOR - 1 YEAR TRANSMITTER - 2 YEARS ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -4°F to +122°F; -20°C to +50°C Storage Temperature Range -4°F to +122°F; -20°C to +50°C Operating Humidity Range 0-100% RH non-condensing MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Maximum = 65mA (1.6 watts) Inrush Current 1.67A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Loop, Input Voltage, Zero, Missing Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Detcon Remote/Alarm Module
The Remote Sensor/Alarm Relay Module (known as the Remote/Alarm Module or RAM) is sold separately as an accessory for Model 700 and 100 Series gas sensors. It is a universal design and can be used with any of the Model 700 or 100 gas sensors. The RAM is provided in an explosion-proof junction box constructed of either epoxy-painted aluminum or 316 stainless steel, and includes a glass-viewing window. The RAM has two main functions. The first function is used to set gas alarm levels and to configure the three local relay contacts. The second function is used to operate a the gas sensor remotely. The remote sensor function is typically used when the sensor must be mounted in a position where it cannot be viewed or accessed readily. Both functions can be used at the same time. The RAM provides the 4-20 mA output directly from the gas sensor (Model 700 only). The RAM acts as a Modbus™ master to the gas sensor in order to display the reading and execute the remote control functions. It acts as a Modbus™ slave to any master control device and simply repeats the Modbus™ output from the gas sensor it is connected to. Order Guide PN 975-70000A-00A - Remote/Alarm Module in Aluminum Enclosure PN 975-70000A-00S - Remote/Alarm Module in 316 SS Enclosure SPECIFICATIONS: Inputs Model 100 or 700 Gas Sensor Outputs 4-20mA signal (Model 700 only) RS-485 Modbus™ Relay Contacts - Three Form C Rated 5A @ 30 VDC/250 VAC Input Voltage 11-30VDC Power Consumption* < 0.5 Watts at 24VDC (Normal) <1.5 watt at 24VDC (Maximum) * Excluding Gas Sensor Operating Temperature -40°C to 70°C Electrical Classification Class I, Division 1 Groups BCD Class I, Zone 1, Group IIC Ex d IIb +H2 T4 Gb cCSAus DEKRA 15ATEX0025 X FEATURES Mimics Gas Sensor Display emote calibration of Gas Sensor Remote setting capability Complete Diagnostic Information RS-485 Connection to Sensor Module 2 Alarm Relays & 1 Fault Relay Product Data Sheet -
Teledyne Detcon TP-524D Hydrogen Sulfide Sensor
Model TP-524D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the ranges of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidityperformance. Model TP-524D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D). Model TP-524D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, self-adjusting zero and span, and LED indicators for fault and calibration status. A HART communications option is also available. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty Order Guide Specify junction box options (below) PN 965-015420-100 - Model TP-524D in Aluminum Junction Box PN 965-01542B-100 - Model TP-524D-316SS in Stainless Steel Junction Box PN 9H5-015420-100 - Model TP-524D with HART in Aluminum Junction Box PN 9H5-01542B-100 - Model TP-524D-316SS with HART in Stainless Steel Junction Box Note above part numbers are for 0-100 ppm range. For 0-20 ppm or 0-50 ppm range replace -100 with -020 or -050 respectively APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S Sensors dating back 20 years Simple menu driven calibration - less than 3 minutes LED display and LED indicators for FAULT and CAL status Plug-in field-replaceable transmitter Response similar to electrochemical sensors: T-50 <30 sec., T-90 <60 sec. 10 year conditional sensor warranty Direct response constant temperature control Withstands exposure to high range concentrations of H2S and other acid gases Impervious to high moisture environments in both powered and non-powered mode Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of ) Response/Clearing Time T50 <30 seconds; T90 <60 seconds Outputs Linear 4-20 mA DC HART (optional) Electrical Classification Explosion proof CSAus Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C) ) Class I, Zone 1, Group IIB+H2 cCSA Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB+H2 FM Class I, Division 1, Groups B, C, D (Tamb = -40°C to +60°C) Complies with ANSI/ISA 92.00.01-2010 ATEX Ex d IIB+H2 T4 (Tamb = -40°C to +60°C) Ingress Protection NEMA 4X, IP66 Warranty Plug-in detector - 10 year conditional Transmitter - 2 year ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -35°C to +55°C; -13°F to +131°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) RFI/EMI Protection Complies with EN 50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting LEDs for Fault and Calibration Faults Monitored Heater, Loop, Input Voltage Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon TP-624D Hydrogen Sulfide Sensor
Model TP-624D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the ranges of of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidity performance. Model TP-624D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D). Model TP-624D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, one-man remote calibration, self-adjusting zero and span, and LED indicators for 2 alarm relays and 1 fault relay and calibration status. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty. Order Guide Specify junction box options (below) PN 966-014520-100 - TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet PN 966-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-014520-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart PN 9H6-01452B-100 - TP-624D-HRT Solid State MOS H2S Sensor Assembly 316SS condulet with Hart Note above part numbers are for 0-100 ppm range. For 0-20 ppm or 0-50 ppm range replace -100 with -020 or -050 respectively. APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S sensors dating back 20 years Compatible with PLCs, SCADA, DCS, via 0-20 mA, and /or RS-485, and/ or alarm relays Sensor status ad parameters accessible via RS-485 (Modbus) Menu programmable relays standard (two alarms plus fault) Simple menu driven calibration- less than 3 minutes LED display and LED indicators for FAULT and CAL ststus Plug-in field-replaceable transmitter Response similar to electrochemical sensor:T50 <30sec., T80 <60 sec. 10 year conditional sensor warranty Direct response constant temperature control Withstands exposure to high range concentrations of H2S and other acid gases Impervious to high moisture environments in both powered and non-powered mode Extensive Fault diagnostics SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of ) Response/Clearing Time T50 <30 seconds; T80 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Electrical Classification Explosion proof CSAus Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C) ) Class I, Zone 1, Group IIB+H2 cCSA Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB+H2 ATEX Ex d IIB+H2 T4 (Tamb = -40°C to +60°C) Safety Approvals cCSAus ATEX CE Marking SIL2 FMEDA Rating Ingress Protection IP66 Warranty Plug-in detector - 10 year conditional Transmitter - 2 year warranty ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) Storage Temperature Range -35°C to +55°C; -13°F to +131°F Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center Weight 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 12-28 VDC* * 12 VDC available by special order Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) RFI/EMI Protection Complies with EN 50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration Relay Outputs Alarm 1, Alarm 2, and Fault 5A @ 250VAC 5A @ 30VDC Faults Monitored Heater, Loop, Input Voltage Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity Product Data Sheet -
Teledyne Detcon TP-700 Hydrogen Sulfide Sensor
Model TP-700 is a non-intrusive “Smart” sensor designed to detect and monitor H2S in air over the range of 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The TP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model TP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model TP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s solid state MOS H2S gas sensor has an infinite shelf life and is supported by a 10-year conditional warranty. Order Guide Specify junction box options (below) PN 967-015520-100 - TP-700 Sensor Assembly (no junction box) PN 967-011520-100 - TP-700 Sensor Assembly with Aluminum Junction Box PN 967-014520-100 - TP-700 Sensor Assembly with 316 SS Junction Box PN 9H7-011520-100 - TP-700 with HART in Aluminum Junction Box PN 9R7-011520-100 - TP-700 with RAM in Aluminum Junction Box APPLICATIONS: Oil and Gas Drilling Rigs Oil and Gas Production Sites Refining and Petrochemical Pulp and Paper Mills Waste Water Treatment Plants FEATURES: Failsafe User-Friendly Interface LED Display (With Antiglare Cover) Full Text Display Method Non-intrusive Interface Auto Zero/Auto Span Pre-emptive Fault Diagnostics Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bulletproof I/O Protection Water-Proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Modular Design Plug and Play Components Quick Thread Release (For Sensor Replacement) Integral Calibration Port SYSTEM SPECIFICATIONS: Sensor Type Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor Plug-in field replaceable Sensor Life 5 to 10 years typical Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of) Response/Clearing Time T50 <30 seconds; T80 <60 seconds Outputs Linear 4-20 mA DC RS-485 MODBUS-RTU Electrical Classification Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) Ingress Protection NEMA 4X, IP66 Safety Approvals cCSAus Complies with ISA 92.01 Part 1-1998; Performance Requirements for H2S ATEX CE Marking SIL2 Certified to IEC 61508 Warranty Plug-in detector - 10 year conditional Transmitter - 2 Years ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -40°F to +167°F; -40°C to +75°C Storage Temperature Range -31°F to +131°F; -35°C to +55°C Operating Humidity Range 5-100% RH non-condensing Operating Pressure Range Atmospheric ±10% MECHANICAL SPECIFICATIONS: Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box) Mounting holes (J-box) 5.5”; 140mm center to center Weight 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) ELECTRICAL SPECIFICATIONS: Power Input 11-30 VDC Power Consumption Normal operation = 68mA (<1.7 watt) Maximum = 85mA (2 watts) Inrush Current 1.0A @ 24V RFI/EMI Protection Complies with EN50270 Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition Serial RS-485 Output RS-485 Modbus™ RTU Baud Rate 9600 BPS (9600,N,8,1 Half Duplex) Status Indicators 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting Faults Monitored Heater, Loop, Input Voltage, Sensor, Processor, Memory, Calibration Cable Requirements Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity INTEGRATION OPTIONS Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault) Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered) Product Data Sheet -
Teledyne Freedom 5000 Toxic Gas Detector
Making installation and everyday operation easy The Freedom Series 5000 are full-featured 4-20mA, loop powered transmitters designed to reliably detect oxygen and any of a number of toxic gases. Its universal electronics and flexible, user-friendly features drive down gas detection costs for almost any facility. Advanced Gas Sensors and Universal Electronics The Freedom series advanced GasPlus sensor technology combines with the Freedom’s universal electronics to simplify use and minimize maintenance requirements of your gas detection system. Every Teledyne Gas & Flame Detection instruments “smart” sensor provides data such as gas type, range, and calibration data to the universal electronics for automatic transmitter configuration. A built-in lithium battery keeps the sensor “hot,” which eliminates the need for sensor warm-up time. On board electronics enables users to easily zero and calibrate the sensor.. An E-connector eliminates pin alignments and makes sensor replacement quick and easy. Easy Installation, Operation and Maintenance The unique electrical design of the Freedom transmitter and sensor virtually eliminate false alarms due to RFI/EMI sources. The transmitter can be mounted directly to rigid conduit and is available with several optional adapters including wall/surface mount and a special “L” shaped bracket to allow mounting on top of flat surfaces such as gas cabinets. Freedom series transmitters are also available with quick connect 1/4 turn sample draw and (flat or round) duct mount adapters. The sensor can be ordered integral to the transmitter or remote on three feet of cable, perfect for mounting the sensor near ground level while keeping the display at eye level. Operating Freedom transmitters is simple and intuitive. After start-up, the transmitter automatically configures to the sensor's parameters. The “missing sensor indicator” alerts operators that the sensor is either missing or the sensor transmitter connection has been broken. Calibration is non-intrusive, performed by touching a magnet to the "Z" (zero), "S" (span), and up and down arrow markings on the enclosure. A programmable local inhibit feature and standard local display allows true one person calibration. Advanced features and smart sensor technology Standard Features of the Freedom 5000 Freedom from stocking additional electronics. Universal transmitter electronics for all gas models. Freedom from intrusive operation/calibration. A simple magnetic interface and local inhibit eliminates special tools or expensive IR remote controls. Freedom from sensor pins or wires. E-connector makes for quick easy installation. Freedom from field maintenance and calibration. Smart sensor technology permits sensor removal for remote calibration. Freedom from zero drift and interfering gases. Rock Solid Sensor Technology offers superior stability and selectivity. Freedom from sensor failure without warning. Built-in calibration factor notifies user of remaining sensor life. Freedom from RFI/EMI induced alarms. Design concept eliminates interference through electronic design versus shielding. Freedom from sensor warm-up times. An internal battery keeps the sensor “warm” for immediate start up. Freedom from corrosion. All plastic construction with conformal coated internal circuitry. Redundancy of Safety Features – gives confidence in the life-saving equipment and allows workers to focus on the critical job at hand. Ease of Use – provides users a simple-to-use gas detector that requires minimal training, increases operational efficiencies and reduces training costs. Low Cost of Ownership – lowers costs after initial sale through its rugged design, assembly and warranty policy enabling you to direct valuable funding to training and other equipment cost. We Make Sensors that Make a Difference Our team of research and development scientists work every day to advance sensor technologies and improve manufacturing techniques. The result – reliable, stable, and gas specific sensors including our Rock Solid series of high performance sensors. High Performance Gas Sensors Rock Solid high performance sensors use our proprietary technology that significantly enhances sensor performance. Rock Solid sensors can detect gas concentrations lower than other electrochemical gas sensor. Rock Solid sensors provide: Highest stability Lowest zero drift Greatest sensitivity Greatest specificity to the target gas Fastest speed of response and recovery time Rock solid Sensor technology Our advanced electrochemical, high performance Rock Solid sensors for the Freedom 5000 are available to detect many toxic gases. Chlorine Chlorine Dioxide Fluorine Hydrogen Bromide Hydrogen Chloride Hydrogen Fluoride Nitrogen Trifluoride Ozone Sulfur Dioxide Freedom 5000 Gas and sensor list: Ammonia (NH3) Arsine (AsH3) Carbon Monoxide (CO) Chlorine (Cl2) Rock Solid Chlorine Dioxide (ClO2) Rock Solid Fluorine (F2) Rock Solid Ethylene Oxide (ETO) Hydrogen Bromide (HBr) Rock Solid Hydrogen Chloride (HCl) Rock Solid Hydrogen Cyanide (HCN) Hydrogen Fluoride (HF) Rock Solid Hydrogen Sulfide (H2S) Nitrogen Dioxide (NO2) Nitrogen Trifluoride (NF3) Rock Solid Oxygen (O2) Ozone (O3) Rock Solid Silane (SiH4) Sulfur Dioxide (SO2) Rock Solid Sulfur Dioxide (SO2) Freedom 5000 sensor connections available Integral Sensor with Transmitter Separated Sensor with 3 ft of cable available with remote sensor, flowcell or duct mount configurations Freedom 5000 adapters available Rain Shield Flat Duct Adapter Round Duct Adapter (6 to 8 in diameter typical) Flow Cell Freedom 5000 transmitter mounting adapter Wall/Surface Mount “L” Bracket used for mounting horizontal surfaces Specifications and ordering information Freedom 5000 specifications Transmitter Enlosure NEMA-4X Noryl plastic with stainless steel screws and hinge 2 each 1/2 in FNPT Weight 1.0 lbs (0.45kg) without accessories Approvals CSA Ex ia IIC T4, AEx ia IIC T4 2002 1280868x Zone 0, Class 1, Division 1, Groups A, B, C and D (with conforming I.S. barrier) Class 1, Division 2, Groups A, B, C and D (without the need for an I.S. barrier) Common specifications CSA Class 1 Division 2 Groups A, B, C and D Self-Diagnostics Weak sensor indication; Electronic faults; Missing sensor; Sensor configuration (range and type) Repeatability +- 2% FS Linearity +- 2% FS Output 4-20mA Max Loop Road 2-Wire; 700 ohms at 24 VDC (22 mA based) Power 10 to 28 VDC 2-wire loop power, 0.5 Watts at 24 VDC Separated Sensor Up to 3 ft (0.9M) Display 3.5 digit LCD; 0 to 100% concentration bargraph; Inhibit Indication (IHB); Overrange Indication (OR); Low Cal Factor Indication – below 150 (SEN) Local Inhibit Programmable: 3.0 to 20mA Temperature Sensor: See Capabilities Chart Transmitter: -40° to 140°F (-40° to 60°C)* Note: at temperatures below 22°F display may not be visible Humidity Up to 99% RH, non-condensing (up to 100% R.H. with optional humi-shield) Not recommended for continuous extreme high/low humidity applications Product Data Sheet -
Teledyne Meridian Universal Gas Detector
Designed with safety and reliability in mind, the Meridian universal gas detector is suitable for use in SIL-2 and SIL-3-rated systems under the IEC 61508 standards, certified by TUV-Rheinland, an independent third-party agency. Third party SIL certification validates that the product meets the most rigorous standards for reliability and performance and confirms its ability to reduce your potential for downtime and increase your safety factor. (*SIL renewal pending) Features Minimal drift High specificity Digital ID Broader toxic gas detection The term “universal” is frequently used in the industry to characterize gas detectors that address both toxic and combustible gases, but it is rare to find instruments that truly live up to that claim. Upon close inspection, you will find that often the only characteristic that can be called “universal” is their user interface. In other words, the instrument provides a common user interface for both combustible and toxic gas detection. At Teledyne Gas & Flame Detection, we believe “universal” should be much more than a common user interface, and we applied this thinking to every aspect of the design of the Meridian universal gas detector. You will find that the Meridian universal gas detector is the industry’s first truly universal gas detection platform. Single detector head for all applications Whether you need an infrared or catalytic bead sensor to detect combustible gases or an electrochemical sensor for a toxic environment, the Meridian universal gas detector utilizes a single detector head to easily accept all sensor types. There is no requirement for distinct personality boards in the gas detector or different detector heads to make the instrument behave as a combustible or toxic gas detector. The Meridian gas detector accepts all sensor types in one detector. Simply attach the specific toxic or combustible sensor to the universal detector head and the Meridian gas detector will automatically determine the type of gas to be detected. Installation of the sensor is a simple plug-and-play action. At Teledyne Gas & Flame Detection, we are always looking to anticipate your future needs. We designed the Meridian gas detection platform to be future proof, allowing you to take advantage of new sensing technologies from Teledyne Gas & Flame Detection while maintaining ease of use and peace of mind. Single of accessories The Meridian gas detector has a single set of accessories for your application needs—another merit of a truly universal gas detection platform. Because all accessories for the Meridian gas detector are designed for the universal detector head, there is no need for purchasing separate accessories for toxic and combustible applications. The following accessories are available for the Meridian Transmitter: CALIBRATION ADAPTER: Easily attaches to the sensor housing to deliver calibration gases to the detector head. FLOW CELL: Allows customers to bring a gas sample to the sensor. DELUGE GUARD: Protects the sensor from heavy rain and water spray from plant wash down routines. DUCT MOUNT KIT: Allows you to remote mount sensors onto ventilation ducts to verify. SENSOR SIMULATOR: A useful commissioning and trouble-shooting tool to locally simulate gas concentration and trigger a response from the detector. UNIVERSAL MOUNTING KIT: With predefined cut outs, you can easily replace older gas detectors with the Meridian detector, making it an ideal choice for retrofit applications. SUN SHIELD: Deflects direct sunlight from the Meridian reducing glare on the display. It also helps reduce the internal temperature of the transmitter. One detector with global approvals and a plug-and-play design Safety integrity level: Designed with safety and reliability in mind, the Meridian universal gas detector is suitable for use in SIL-2 and SIL-3-rated systems under the IEC 61508 standards, certified by TUV-Rheinland, an independent third-party agency. Third party SIL certification validates that the product meets the most rigorous standards for reliability and performance and confirms its ability to reduce your potential for downtime and increase your safety factor. Key regulatory approvals: CCSAUS ATEX IECEx INMETRO SIL-2 certified by TUV-Rheinland (*SIL2 renewal pending) Global certifications and approvals The Meridian gas detector is certified using the highest international standards for global use. Our goal is to offer customers one instrument that can be used across regions. So whether you procure the instrument for use in a chemical plant in North America, on an FPSO in Latin America or in an oil refinery in Europe or Asia, the instrument will have the necessary approvals required for use in that region. Unlike industry standard offerings, the Meridian gas detector is not a collection of gas detectors, each certified for use in a particular region. What makes it truly universal is that it is a single detector that has all the required approvals for global use. Advancement in Sensor Technology At Teledyne Gas & Flame Detection, we believe in innovation with a purpose. To that end, we made a number of advancements in our sensor technology with the Meridian universal gas detector to deliver additional value to our customers and reduce their overall cost of ownership. Sensor replacement without declassifying the area The Meridian gas detector’s intrinsically safe, plug-and-play sensor design allows you to perform sensor replacements without powering down the instrument. You no longer need to declassify an area during sensor replacement. This allows you to maintain your plant production uptime and maintain a safe working environment for workers at the same time. Toxic sensors offer range invariant calibration Sensor calibration, while absolutely necessary, can be a very challenging and timeconsuming activity. To help our customers reduce operational hazard and maintenance cost, we have designed a toxic sensor technology that is linear throughout and range agnostic. With the Meridian gas detector, you can calibrate a toxic sensor to a particular gas level and then make adjustment to the range later without having to re-calibrate the sensor to the new range. For example, to optimize maintenance workload, you can calibrate sensors in a batch in the lab and set them to a default range. Upon installation, the range on the sensors can be adjusted to the requirements of the specific location. The range on the sensor can be readjusted anytime to the set of pre-defined ranges by the end user. This sensor design also provides flexibility in easily calibrating sensors where a specific gas range is inaccessible or unavailable. Simply calibrate the sensor with an available surrogate gas range and then readjust the sensor range to the set of predefined ranges available for that sensor. Automantic sensor voltage detection and adjustment To minimize installation and commissioning time, the Meridian automatically detects current voltage and makes the required voltage adjustments for catalytic bead sensors without intervention from the installer. This reduces installation time and also the required tooling expertise necessary for sensor installation. Complete sensor range & Best-in-class sensor performance Full-range detection The Universal Gas Detection System detects a full range of combustible and toxic gases. Multiple Sensors The Meridian gas detector allows up to three sensors to be attached to a single instrument. Use the multi-sensor detector to: Monitor for toxic and combustible gases from the same detector. Accurately detect gases particularly difficult to detect due to cross interference from other gases. Reduce your overall cost per point of detection while increasing overall safety. Remotely mount sensors up to 100 feet from the gas detector to meet requirements of specific applications. Combustible gases Acetaldehyde Decane Isobutane Pentane Acetone Diethyl Ether Isobutylene Propane Acetylene Ethane Isopentane Propylene Ammonia Ethanol Isopropanol Propylene Oxide Benzene Ethyl Acetate Methane Styrene Butadiene Ethylbenzene Methanol Tetrahydrofuran Butane Ethylene Methyl Chloride Toluene Butanol Ethylene Oxide Methylene Chloride Vinyl Chloride Butyl Acetate Heptane Methyl Ethyl Ketone (MEK) Xylene Chlorobenzene Hexane Octane Cyclohexane Hydrogen Octamethyl Trisiloxane Toxic Gases Ammonia Hydrogen Cyanide Bromine Hydrogen Fluoride Carbon Monoxide Hydrogen Sulfide Chlorine Nitrogen Dioxide Chlorine Dioxide Oxygen Fluorine Ozone Hydrogen* Silane Hydrogen Chloride Sulfur Dioxide Rock Solid Sensor available for toxic gases highlighted in bold. The Rock Solid Advantage: More Reliable, Accurate Detection Minimal drift: Performs reliably in harsh real-world environments by significantly reducing effects of temperature and humidity. High specificity: Allows for much lower interference from other gases than conventional gas sensors, reducing cross interference from other gases present and reduces the likelihood of a false alarm. Digital ID: Provides automatic recognition when sensors are replaced, reducing the likelihood of user error during maintenance in the field. Broader toxic gas detection: Several ranges are available for each gas to optimize the sensor’s response in the environment. The right choice for your Gas Detection application Making the best decision for today One product for toxic and combustible applications with global approvals Reduces inventory costs Reduces training costs Simplifies installation Easy to install, commission and train your instrumentation workers Reduces start-up time Reduces labor associated with initial installation Reduces risk for installer error Rock Solid sensing technology offers accurate and reliable detection Reduces the impact of environmental factors Improves safety factor of the facility Advanced communication protocols offer detailed diagnostics data allowing for proactive maintenance and a safer environment Offers flexibility in developing your gas detection system through industry standard communication protocols Increases safety by allowing improved access to real-time information on the detector status and environment Incorporation of a SIL-2-rated device into your facilities’ operation for industry validated best-in-class performance (*SIL2 renewal pending) Making the best decision for tomorrow Ability to incorporate new sensing technology in the future Future proof plug-and-play design allows all future sensing technologies from Teledyne to easily integrate into the Meridian gas detector Ability to seamlessly incorporate new communication protocols Stay current on industry trends and take advantage of new industry standard communications protocols as they become available on the Meridian gas detection platform—another example of future proof design Reduce maintenance time and cost associated with sensor calibration Innovative sensor design allows for bench calibration and range invariant calibration for toxic sensor, which optimize ongoing maintenance workloads and offer significant cost savings Teledyne gas & Flame Detection Global Service Network and warranty system Reduce cost, waste and environmental impact with an environment-friendly sensor design Commit to green technology initiatives and environmental stewardship Communication Protocols: Designed for global use, the Meridian universal gas detector supports industry standard protocols for integration into any industrial network. Support for digital protocols allows for advanced diagnostics data to be available, making it possible to take proactive measures to maintain a safe environment and lowering your overall cost of ownership. Standard, wired protocols 4–20 mA Modbus Optional protocols WiredHART Product specification Certifications Global Approvals IECEx, cCSAus, ATEX, INMETRO INDUSTRY CANADA, CE, SIL-2 (Third Party Certification by TUV-Rheinland) Area Classification Class I Div. 1 Group ABCD, Class II Div. 1 Group EFG, Class III Equipment Group I/II, Zone 0/20 & Zone 1/21, IIC Environmental Operating Temperature -40° to 75° Celsius Humidity 5–95% RH (non condensing) Storage Temperature -55° to 75° Celsius Specifications Power 2 wire, 3 wire, 4 wire Operating Voltage 3/4 wire 10-30 VDC (24 VDC nominal) Operating Voltage 2 wire 18-30 VDC (24 VDC nominal) Power Consumption 2.2 - 3.2 Watts based on sensor configuration Add 2.6 Watts to any configuration if heated display is used Enclosure Material Copper-free aluminum, 316 stainless steel Enclosure Ingress Protection NEMA 4X, IP66 Terminal Junction Box Material Copper-free aluminum, 316 stainless steel Terminal Junction Box Conduit Connection 3/4" NPT (M20 adapter available) Communication 4–20 mA, MODBUS; Optional HART Maximum 4–20 loop load, OHMS (@24 VDC) 680 Ohms current source 680 Ohms current sink Alarms 3 programmable alarms with set and reset (adjustable deadband); 1 fail safe system fault Relays 4 Form C relays, rated 5 Amp at 30 VDC/240 VAC, resistive loads Display Graphical LCD display visible in bright sunlight. Display indicates Sensor Name, Gas Name, Full Scale of Range, Gas Concentration, Fault, Alarm Status, Trend Graph with selectable time scale showing current reading, set points and full scale. Display provides simple, intuitive calibration instructions and guides user through the calibration process. Languages English, Portuguese, French, Spanish, Chinese, Russian User Configuration Control Transmitter GUI, HART hand-held Communicator, MODBUS User Interface Access Control Transmitter provides controlled access to sensor range, alarm settings and other safety functions; password protection for secure configuration control Memory Non-volatile memory ensures configuration parameters are retained in the event of power loss Sensor specifications Sensor Types Combustible: Catalytic bead Electrochemical: Standard and Rock Solid sensors Number of Sensors Supports up to 3 sensors per detector Installation Weight Aluminum enclosure: 6.5 lbs (3 kg); Stainless steel enclosure: 11 lbs (5 kg) Wiring Detector accepts industry standard 2-wire, 3-wire or 4-wire inputs Product Data Sheet -
Teledyne SafEye Open Path Combustible Gas Detector
The SafEye Open Path Detector is an innovative, next generation solution to open path combustible gas detection. It can replace multiple point detectors, detects multiple gases at once, and is durable, proving to be a smart, cost efficient choice for combustible gas detection. Features Three color LED gives a quick visual of unit status Intrinsically Safe communication port can be used with HART® Hand-Held in non-safe areas for setup and diagnostics Heated optics provide unfettered Detection in most environments Long range, up to 200 meters, reduces number of units required Fast response (< 3 seconds) gives quick alert to hazards Low maintenance requirements saves time and money Multiple regulatory approvals Connects easily to existing systems User programmable functions allow customization Event recorder keeps track of all alerts and warnings High reliability and a three-year warranty provide peace of mind Reliable open path gas detection Long range, fast detection and lower cost of ownership Save costs in line-of-sight applications One SafEye Open Path Detector can replace up to 20 point combustible gas detectors in line-of-sight applications, saving installation and ongoing maintenance costs. With the SafEye there are only two units to service and the maintenance requirements are minimized compared with point detectors. Additionally, there is only one consumable to replace periodically; SafEye Xenon Flash Bulb has a 10 year warranty. Detect multiple combustible gases simultaneously The SafEye IR sensor can detect multiple combustible hydrocarbon gases at the same time - perfect for facilities with multiple hydrocarbon gases to monitor, such as C1-C8 hydrocarbons (Methane, Ethane, Ethylene, Propane, Propylene, n-butane, Isobutane, 1, 3-butadiene, Isobutylene, Alkanes, Alkenes, Naphthenes, Benzenes). Handle tough environments with confidence, longer Robustly designed to handle the toughest work environments and maintain a long operating life, the SafEye Open Path Gas Detector is equipped with 316L stainless steel casings and mounts, coated circuit boards for protection, and is SIL-2 approved per IEC61508. Additionally, the SafEye detector meets MIL-C-810C standards for humidity, salt, fog, vibration, mechanical shock and temperature extremes, while the housings meet IP66, IP68 and NEMA 250 6P water and dust egress standards. Accessories Commissioning Kit PN 8000449 USB/RS485 Harness PN 8000453 HART® Hand-Held Communicator Kit PN 8000451 Commissioning kit includes: Alignment Telescope, Magnetic Mode Selector, Function Check Filters and socket keys. Connect to your PC to adjust detector settings. Only for use in Safe Areas. Tool to connect to the detector to view, change and maintain settings. While we may be more well-known for its long history in the fire safety industry, it has also proudly served the gas detection and protection industry for over 50 years. The SafEye Open Path Detector is part of the newest generation of gas detection equipment, proving to be yet another smart solution innovatively designed with customer needs and safety as first priority, always. Specifications and ordering information Product Specifications Detector /Source with Tilt Mount Dimensions (each) 10.5 x 11.4 x 5.1 inch (267 x 288 x 130 mm) Detector/Source with Tilt Mount Weight (each) 15.2 lbs (6.9 kg) Enclosure and Tilt Mount Material 316L Stainless Steel Operating Temperature Range / Humidity -67oF to 149oF -55oC to 65oC 0 – 95% RH (non condensing) Minimal Detectable Gas Level 0.15 LEL.m Communication 4-20 mA, MODBUS®, HART® Enclosure Ingress Protection NEMA 250 6P type, IP66/IP68 Electrical Connections 3 or 4 wire connections 10 – 32 VDC 6 Watts Max per unit Electromagnetic Compatibility EMI/RFI protected per EN50270 Approvals ATEX/IECEx: II 2(2)G D, Ex db eb [ib Gb] IIB+H2 T4 Gb, Ex tb IIIC T135oC Db, Ta = -55oC to +65oC FM/FMC: Class I Div. 1 Groupe B, C et D Class II/III Div. 1 Group E, F et G DNV: Type Approval Certification Certificate No. A-13607 SafEye Open Path Detector Kits OPGD-901-C-111 SafEye Model 20 (7-20 m Range), ATEX, M25 OPGD-901-C-112 SafEye Model 20 (7-20 m Range), ATEX, 3/4" NPT OPGD-901-F-111 SafEye Model 20 (7-20 m Range), FM, M25 OPGD-901-F-112 SafEye Model 20 (7-20 m Range), FM, 3/4" NPT OPGD-902-C-211 SafEye Model 40 (15-40 m Range), ATEX, M25 OPGD-902-C-212 SafEye Model 40 (15-40 m Range), ATEX, 3/4" NPT OPGD-902-F-211 SafEye Model 40 (15-40 m Range), FM, M25 OPGD-902-F-212 SafEye Model 40 (15-40 m Range), FM, 3/4" NPT OPGD-903-C-311 SafEye Model 100 (35-100 m Range), ATEX, M25 OPGD-903-C-312 SafEye Model 100 (35-100 m Range), ATEX, 3/4" NPT OPGD-903-F-311 SafEye Model 100 (35-100 m Range), FM, M25 OPGD-903-F-312 SafEye Model 100 (35-100 m Range), FM, 3/4" NPT OPGD-904-C-411 SafEye Model 200 (80-200 m Range), ATEX, M25 OPGD-904-C-412 SafEye Model 200 (80-200 m Range), ATEX, 3/4" NPT OPGD-904-F-411 SafEye Model 200 (80-200 m Range), FM, M25 OPGD-904-F-412 SafEye Model 200 (80-200 m Range), FM, 3/4"NPT Each kit contains source, detector and two Tilt Mounts. SafEye Accessories OPGD-888270 Tilt Mount OPGD-799225 Pole Mount (U-Bolt 5 inch) OPGD-888247-1 Commissioning, alignment and optical verification kit - Methane OPGD-888247-2 Commissioning, alignment and optical verification kit - Propane OPGD888247-3 Commissioning, alignment and optical verification kit - Ethylene OPGD-888815 HART Hand-Held Harness Kit OPGD-794079 USB/RS485 Harness Converter Kit OPGD-888263 Sunshade, Stainless Steel OPGD-888260-3 Function Check Filter Warning Level - Methane OPGD-888260-4 Function Check Filter Alarm Level - Methane OPGD-888260-1 Function Check Filter Warning Level - Propane OPGD-888260-2 Function Check Filter Alarm Level - Propane OPGD-790285 Magnetic Mode Selector Product Data Sheet