Moisture Content Sensor
Showing all 4 results
-
Des-Case MCC-2-B-030 Moisture Content Sensor
$88.33Moisture Content Sensor Power Data Cable, 8-pins connection, 10ft / 3m The moisture content sensor (MCS) is suitable for most hydraulic and lubricating fluids. The high accuracy of the measurement and excellent long-term stability make the MCS ideal for online monitoring of moisture in transformer, lubricating and hydraulic fluid, as well as diesel fuel. The MCS is perfectly suitable for long-term usage in moisture levels, higher than 90% RH. Making it the perfect solution for gearboxes, thrusters and other applications where free water is a threat. By combining the MCS with other Des-Case products like a Condition Monitoring Center and Vacuum Dehydration Unit, we offer you the optimal solution for your water contamination problems. Specifications MEASUREMENT PERFORMANCE Measurement Range: 0-1 aw, 0 -100% RHMoisture Accuracy (including non-linearity, hysteresis, and repeatability): 0 – 0.9 aw ± 0.02 aw, 0.9 – 1.0 aw ± 0.03 awResponse time in oil flow (typical): < 1 min (dry-wet)Temperature Accuracy at +68°F (+20°C): ± 0.36°F (0.2°C) OPERATING ENVIRONMENT Electromagnetic compatibility: EN61326-1Ambient temperature: -40…60 °C (-40…140 °F)Storage temperature: -40…80 °C (-40…176 °F)Oil temperature: -40…100 °C (-40…212 °F)Oil flow: Some flow recommendedPressure Rating: 0…200 bar (0…2900 psi)Fluid compatibility¹: Petroleum based and synthetic fluids INPUTS & OUTPUTS Analog current output: 0 – 20 mA, 4 – 20 mAAnalog voltage output: 0 – 5 V, 0 – 10 VDigital output: RS-485, MODBUS RTU MECHANICAL SPECIFICATIONS Electrical connection: M12 8-pin plugConnection: G1/2’’ BSPSupply voltage: 21-28 VDCSupply current: 20 mA + load currentHousing / protection rating: Stainless steel (AISI 316L) / IP66 TDS -
Des-Case MCC-2-B-100 Moisture Content Sensor
$165.63Moisture Content Sensor Power Data Cable, 8-pin connection, 33ft / 10m The moisture content sensor (MCS) is suitable for most hydraulic and lubricating fluids. The high accuracy of the measurement and excellent long-term stability make the MCS ideal for online monitoring of moisture in transformer, lubricating and hydraulic fluid, as well as diesel fuel. The MCS is perfectly suitable for long-term usage in moisture levels, higher than 90% RH. Making it the perfect solution for gearboxes, thrusters and other applications where free water is a threat. By combining the MCS with other Des-Case products like a Condition Monitoring Center and Vacuum Dehydration Unit, we offer you the optimal solution for your water contamination problems. Specifications MEASUREMENT PERFORMANCE Measurement Range: 0-1 aw, 0 -100% RHMoisture Accuracy (including non-linearity, hysteresis, and repeatability): 0 – 0.9 aw ± 0.02 aw, 0.9 – 1.0 aw ± 0.03 awResponse time in oil flow (typical): < 1 min (dry-wet)Temperature Accuracy at +68°F (+20°C): ± 0.36°F (0.2°C) OPERATING ENVIRONMENT Electromagnetic compatibility: EN61326-1Ambient temperature: -40…60 °C (-40…140 °F)Storage temperature: -40…80 °C (-40…176 °F)Oil temperature: -40…100 °C (-40…212 °F)Oil flow: Some flow recommendedPressure Rating: 0…200 bar (0…2900 psi)Fluid compatibility¹: Petroleum based and synthetic fluids INPUTS & OUTPUTS Analog current output: 0 – 20 mA, 4 – 20 mAAnalog voltage output: 0 – 5 V, 0 – 10 VDigital output: RS-485, MODBUS RTU MECHANICAL SPECIFICATIONS Electrical connection: M12 8-pin plugConnection: G1/2’’ BSPSupply voltage: 21-28 VDCSupply current: 20 mA + load currentHousing / protection rating: Stainless steel (AISI 316L) / IP66 TDS -
Des-Case MCD-S-1 Moisture Content Sensor
$794.76Moisture Content Sensor Display The moisture content sensor (MCS) is suitable for most hydraulic and lubricating fluids. The high accuracy of the measurement and excellent long-term stability make the MCS ideal for online monitoring of moisture in transformer, lubricating and hydraulic fluid, as well as diesel fuel. The MCS is perfectly suitable for long-term usage in moisture levels, higher than 90% RH. Making it the perfect solution for gearboxes, thrusters and other applications where free water is a threat. By combining the MCS with other Des-Case products like a Condition Monitoring Center and Vacuum Dehydration Unit, we offer you the optimal solution for your water contamination problems. Specifications MEASUREMENT PERFORMANCE Measurement Range: 0-1 aw, 0 -100% RHMoisture Accuracy (including non-linearity, hysteresis, and repeatability): 0 – 0.9 aw ± 0.02 aw, 0.9 – 1.0 aw ± 0.03 awResponse time in oil flow (typical): < 1 min (dry-wet)Temperature Accuracy at +68°F (+20°C): ± 0.36°F (0.2°C) OPERATING ENVIRONMENT Electromagnetic compatibility: EN61326-1Ambient temperature: -40…60 °C (-40…140 °F)Storage temperature: -40…80 °C (-40…176 °F)Oil temperature: -40…100 °C (-40…212 °F)Oil flow: Some flow recommendedPressure Rating: 0…200 bar (0…2900 psi)Fluid compatibility¹: Petroleum based and synthetic fluids INPUTS & OUTPUTS Analog current output: 0 – 20 mA, 4 – 20 mAAnalog voltage output: 0 – 5 V, 0 – 10 VDigital output: RS-485, MODBUS RTU MECHANICAL SPECIFICATIONS Electrical connection: M12 8-pin plugConnection: G1/2’’ BSPSupply voltage: 21-28 VDCSupply current: 20 mA + load currentHousing / protection rating: Stainless steel (AISI 316L) / IP66 TDS -
Des-Case MCS-01-0-B Moisture Content Sensor
$1,587.30The moisture content sensor (MCS) is suitable for most hydraulic and lubricating fluids. The high accuracy of the measurement and excellent long-term stability make the MCS ideal for online monitoring of moisture in transformer, lubricating and hydraulic fluid, as well as diesel fuel. The MCS is perfectly suitable for long-term usage in moisture levels, higher than 90% RH. Making it the perfect solution for gearboxes, thrusters and other applications where free water is a threat. By combining the MCS with other Des-Case products like a Condition Monitoring Center and Vacuum Dehydration Unit, we offer you the optimal solution for your water contamination problems. Specifications MEASUREMENT PERFORMANCE Measurement Range: 0-1 aw, 0 -100% RHMoisture Accuracy (including non-linearity, hysteresis, and repeatability): 0 – 0.9 aw ± 0.02 aw, 0.9 – 1.0 aw ± 0.03 awResponse time in oil flow (typical): < 1 min (dry-wet)Temperature Accuracy at +68°F (+20°C): ± 0.36°F (0.2°C) OPERATING ENVIRONMENT Electromagnetic compatibility: EN61326-1Ambient temperature: -40…60 °C (-40…140 °F)Storage temperature: -40…80 °C (-40…176 °F)Oil temperature: -40…100 °C (-40…212 °F)Oil flow: Some flow recommendedPressure Rating: 0…200 bar (0…2900 psi)Fluid compatibility¹: Petroleum based and synthetic fluids INPUTS & OUTPUTS Analog current output: 0 – 20 mA, 4 – 20 mAAnalog voltage output: 0 – 5 V, 0 – 10 VDigital output: RS-485, MODBUS RTU MECHANICAL SPECIFICATIONS Electrical connection: M12 8-pin plugConnection: G1/2’’ BSPSupply voltage: 21-28 VDCSupply current: 20 mA + load currentHousing / protection rating: Stainless steel (AISI 316L) / IP66 TDS