Contamination Monitoring Sensor
Showing all 9 results
-
Des-Case CMS-RDU2 Contamination Monitoring Sensor
$1,809.99Contamination Monitor Sensor Remote Display Unit with Keypad. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case CMS-USBi Contamination Monitoring Sensor
$699.38Contamination Monitor Sensor without Moisture sensor, for offshore and selected water based fluids, display, customizable relay, M16x2 connection, with 10 meter cable. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case CMS0M0RG1-2 Contamination Monitoring Sensor
$3,165.32Contamination Monitor Sensor without Moisture sensor, for mineral fluid, no display, customizable relay, M16x2 connection, with 10 meter cable. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case CMS0MKRG1-2 Contamination Monitoring Sensor
$3,741.61Contamination Monitor Sensor without Moisture sensor, for mineral fluid, display, customizable relay, M16x2 connection, with 10 meter cable The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case CMS0NKRG1-2 Contamination Monitoring Sensor
$4,210.34Contamination Monitor Sensor without Moisture sensor, for offshore and selected water based fluids, display, customizable relay, M16x2 connection, with 10 meter cable. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case CMS0SKRG1-2 Contamination Monitoring Sensor
$4,895.67Contamination Monitor Sensor without Moisture sensor, for offshore and selected water based fluids, display, customizable relay, M16x2 connection, with 10 meter cable. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case CMSWM0RG1-2 Contamination Monitoring Sensor
$3,659.08Contamination Monitor Sensor with Moisture sensor, for mineral fluid, no display, customizable relay, M16x2 connection, with 10 meter cable. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case CMSWMKRG1-2 Contamination Monitoring Sensor
$4,233.93Contamination Monitor Sensor with Moisture sensor, for mineral fluid, display, customizable relay, M16x2 connection, with 10 meter cable. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS -
Des-Case FCV-A Contamination Monitoring Sensor
$253.40Flow Control Assembly for CMS: 0,20 l/min, 1/4”BSP m inlet, M16x2 outlet, HEX body, 14-420 bar. The CMS in-line contamination monitor automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and cost are limited. Formats: ISO 4406:1999, NAS 1638, ES4059E Table 2, AS4059E Table 1, ISO 11218Accuracy: ± 1/2 code for 4, 6, 14 μm (c), ± 1 code for larger sizesCalibration: Each unit individually calibrated with ISO Medium Test Dust (MTD) based on ISO 11171 (1999) on equipment certified by IFTS.Hydraulic Fluid Compatibility: Mineral oil & petroleum based fluids (consult RMF Systems for other fluids)Flow Rate: 20-400 ml/minuteViscosity Range: max. 1000 cStFluid Temperature: -25° C to +80° CMax Working Pressure: 420 barElectrical Supply: Voltage 9 – 36V DCSeal Material: FPM (Viton) – Contact Des-Case regarding any fluids that are incompatible with FPM sealsTest Time: Adjustable 10 – 3600 seconds, factory set to 120 secondsMoisture Sensing: % RH (Relative Humidity) ±3%Temperature Measurement: ±3° CFlow Rate Measurement: Indication onlyData Storage: 4000 testsCommunication Options: RS 485, MODBUS, CANBUS, 4-20 mAAmbient Temperature: -25° C -to +80° C or -25° C to +55° C for K versionIP Rating: IP 65/67 versatile IK04 Impact protectionPhysical Dimensions: 123(H) x 142(W) x 65(D) mmWeight: 1,15 kg Sensors: Water and Temperature Sensor The water sensor option measures water content using a capacitive RH (relative humidity) sensor. The results is expressed as percentage saturation. 100% RH corresponds to the point at which free water exists in the fluid, i.e. the fluid is no longer able to hold the water in a dissolved solution. Software All CMS units are supplied with software to download automatically new results as they are generated, provided the test is done while being directly controlled by the software. Or alternatively historical results can be downloaded form the CMS’s inbuilt memory. The CMS memory has space for around 4000 log entries, when full, the oldest log entry is overwritten. Which test are logged, and when, are determined by the log settingsEach log entry is time-stamped and contains the CMS serial number, so that it can be identified later. Accessories CMS “USB-I” ConnectorThis is a ready-made solution for easily connecting a PC/ Laptop to the CMS. CMS-FC1A pressure compensated flow control valve specifically designed to fit the CMS. This may be needed if the application produces an oil flow greater than 400ml/min. TDS