Controllers And Alarms
Showing 496–535 of 535 results
-

Teledyne Detcon 10-0639 Analog Output Option Board
$869.00What is the Teledyne Detcon 10-0639?The Teledyne Detcon 10-0639 is: Analog Output Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0639 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0640 Programmable Relay Option Board
$1,341.00What is the Teledyne Detcon 10-0640?The Teledyne Detcon 10-0640 is: Programmable Relay Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0640 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 10-0641 Discrete Relay Option Board
$1,015.00What is the Teledyne Detcon 10-0641?The Teledyne Detcon 10-0641 is: Discrete Relay Option Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 10-0641 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-1906 Dual light/Piezo
$1,182.00What is the Teledyne Detcon 1000-1906?The Teledyne Detcon 1000-1906 is: Dual light/Piezo. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-1906 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-2259 50W AC to DC Power Supply – Not Available on Compact or NEMA7
$695.00What is the Teledyne Detcon 1000-2259?The Teledyne Detcon 1000-2259 is: 50W AC to DC Power Supply - Not Available on Compact or NEMA7. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-2259 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-2373 120W AC to DC Power Supply – Not Available on Compact or NEMA7
$1,045.00What is the Teledyne Detcon 1000-2373?The Teledyne Detcon 1000-2373 is: 120W AC to DC Power Supply - Not Available on Compact or NEMA7. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-2373 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 1000-2810 GP Red Strobe Local
$366.00What is the Teledyne Detcon 1000-2810?The Teledyne Detcon 1000-2810 is: GP Red Strobe Local. Local visual alarm devices offered with Teledyne Detcon gas detection controllers and Model 1000 series analyzer systems. The group covers red alarm strobes in general purpose and Class I Division 2 versions for local alarm annunciation at the monitored equipment. Detcon also documents relay-based alarm signaling through its controller and remote alarm module products, which these strobes connect to.About the Teledyne Detcon Alarm Stations & Signals lineRed strobe signals in general purpose (GP) and Division 2 rated versionsOffered as local alarm options and spares for Detcon Model 1000 series analyzer and controller packagesDriven by alarm relay outputs of Detcon controllers and alarm modulesWhere is it used?Typical service: Local visual alarm annunciation at the analyzer or controller location; Alarm signaling in Class I Division 2 classified areas using the Div 2 rated strobe.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 1000-2810 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 360-3S6PFP-ASM Flat Battery Pack
$810.00What is the Teledyne Detcon 360-3S6PFP-ASM?The Teledyne Detcon 360-3S6PFP-ASM is: Flat Battery Pack. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 360-3S6PFP-ASM on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 360-DLP075-024 Power supply for X08 N4X
$454.00What is the Teledyne Detcon 360-DLP075-024?The Teledyne Detcon 360-DLP075-024 is: Power supply for X08 N4X. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 360-DLP075-024 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005194-000 Sensor Input Board
$779.00What is the Teledyne Detcon 500-005194-000?The Teledyne Detcon 500-005194-000 is: Sensor Input Board. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005194-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005221-100 Main control board w/display X40 N7X
$1,035.00What is the Teledyne Detcon 500-005221-100?The Teledyne Detcon 500-005221-100 is: Main control board w/display X40 N7X. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005221-100 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 500-005221-200 Main control board w/display X40 N4X
$1,035.00What is the Teledyne Detcon 500-005221-200?The Teledyne Detcon 500-005221-200 is: Main control board w/display X40 N4X. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 500-005221-200 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 7200 Plus Two Channel Gas Controller
What is the Teledyne Detcon 7200-Plus?The Teledyne Detcon 7200-Plus is: Two channel gas detection controller, configured to order (housing, power supply, input, output, relay, and alarm options). The Teledyne Detcon 7200 Plus is a two-channel fixed gas controller that provides simultaneous display and alarm functions for its monitored variables. A graphic LCD presents monitored data as bar graphs and engineering units, with three adjustable alarm levels per channel and nonvolatile memory that retains all configuration data indefinitely. Relay outputs drive beacons, horns, and other alarm events, and an optional RS-485 Modbus slave port allows up to 128 controllers to be multidropped onto a single data highway.Key specificationsTwo monitored channels with graphic LCD showing bar graphs, trends, and engineering unitsThree adjustable alarm levels per channel; nonvolatile configuration memoryTwo standard 5 A Form C relays, expandable with a six-relay discrete alarm board (dedicated Alarm 1, Alarm 2, and Fault relays per channel) or solid-state relay optionsInput power 100-240 VAC or 10-30 VDC with automatic backup switchover; base unit consumes about 1.5 WOption boards: dual 4-20mA analog input, dual bridge sensor input, dual 4-20mA output, RS-232/RS-485 Modbus RTU interface, Ethernet Modbus TCP, and 100 dB piezo audible alarmHousing options: NEMA 4X wall mount (polycarbonate or stainless steel), NEMA 4 painted steel wall mount, and NEMA 7 explosion-proof wall mount for Division 1 and 2 Groups B, C, DApprovals: CSA C22.2 No 1010.1 and ISA S82.02, CSA C22.2 No 152 for combustibles, UL 1604 / C22.2 No 213 (Division 2 Groups A, B, C, D), EN55011 and EN61000 (CE Mark)Where is it used?Typical service: Centralized display and alarming for one or two fixed gas detection points; Combustible and toxic gas monitoring in Class I Division 2 areas; Driving beacons, horns, and other alarm event devices; Multidrop Modbus integration with plant monitoring systems.How is it configured?The 7200 Plus is configured to order. Verified option groups include housing (NEMA 4X polycarbonate, NEMA 4 painted steel, NEMA 4X stainless steel, or NEMA 7 explosion-proof wall mount), power supply (AC, DC, and external 50 W Division 1 or Division 2 supplies), input boards, output and communication boards, relay boards, and audible and visual alarm options such as the 100 dB piezo alarm and light stacks.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 7200-Plus on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 7400 Plus Four Channel Gas Controller
What is the Teledyne Detcon 7400-Plus?The Teledyne Detcon 7400-Plus is: Four channel gas detection controller, configured to order (housing, power supply, input, output, relay, and alarm options). The Teledyne Detcon 7400 Plus is a four-channel fixed gas controller that provides simultaneous display and alarm functions for up to four monitored variables. A graphic LCD displays monitored data as bar graphs and engineering units, with three adjustable alarm levels per channel and nonvolatile memory that retains configuration data indefinitely. Relay outputs control beacons, horns, and other alarm events, and an optional RS-485 Modbus slave port allows up to 128 controllers on a single data highway.Key specificationsFour monitored channels with graphic LCD showing bar graphs and engineering unitsThree adjustable alarm levels per channel; nonvolatile configuration memoryStandard 5 A Form C dry contact relays, expandable with a six-relay discrete alarm board (10-0222) or solid-state relay optionsOption boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), and RS-232/RS-485 Modbus interface (10-0253)Power supply options include 50 W NEMA 4X Division 2 (10-0315) and 50 W NEMA 7 Division 1 (10-0314) suppliesHousing options: NEMA 4X polycarbonate, NEMA 4 painted steel, NEMA 4X stainless steel, and NEMA 7 explosion-proof wall mount enclosuresApprovals: CSA C22.2 No 1010.1 and ISA S82.02, CSA C22.2 No 152 for combustibles, UL 1604 / C22.2 No 213 (Division 2 Groups A, B, C, D), EN55011 and EN61000 (CE Mark)Where is it used?Typical service: Centralized display and alarming for up to four fixed gas detection points; Combustible and toxic gas monitoring in Class I Division 2 areas; Driving beacons, horns, and other alarm event devices; Multidrop Modbus integration with plant monitoring systems.How is it configured?The 7400 Plus is configured to order. Verified option groups include housing (NEMA 4X polycarbonate, NEMA 4 painted steel, NEMA 4X stainless steel, or NEMA 7 explosion-proof wall mount), power supply (AC, DC, and 50 W Division 1 or Division 2 supplies), input boards, output and communication boards, relay boards, and optional alarm devices such as light stacks.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 7400-Plus on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 8800 Multi-Channel Gas Controller
What is the Teledyne Detcon Model-8800?The Teledyne Detcon Model-8800 is: Multi-channel gas detection controller, CSA Class 1 Div 2, NEMA 4X housing, configured to order. The Teledyne 8800 controller provides simultaneous display and alarm functions for up to 16 input variables, combining the proven 7800 controller platform with advanced upgrades in one low-cost package. It offers 8 or 16 channel display modes with I/O modules arranged in groups of 8 channels, so systems can be configured economically. A QVGA color LCD displays monitored data as trends, bar graphs, and engineering units, with readouts that change color to indicate alarms, and a magnetic keypad allows non-intrusive operation in potentially hazardous locations.Key specificationsUp to 16 input channels; inputs include 12-bit 4-20mA (150 ohm impedance) and Modbus, with power supply terminals per channel for 2- or 3-wire transmittersThree independent alarm levels per channel with Relay Acknowledge silencing of external audible devicesFive standard SPDT 5 A alarm relays: HORN, FAULT, and three programmable alarm relaysEthernet Modbus TCP master/slave port with web server; two standard RS-485 ports plus two optional isolated ports for simultaneous Modbus master/slave operationOption cards: 16-bit 4-20mA outputs, 4-20mA inputs, discrete and programmable alarm relaysQVGA 320 x 240 TFT color LCD with LED backlight; SD card data logger records input values and events for more than 10 yearsPower 10-30 VDC (24 VDC nominal), 12 W max; power supply options include 150 W (10-0172) and 600 W (10-0307)Enclosures: wall mount NEMA 4X non-metallic, 316 stainless steel, explosion-proof (XP), and rack/panel mount; approvals CE, CSA C22.2 No 1010.1, C22.2 No 152 for combustibles, ISA S82.02, CSA Class I Div 2 Groups A, B, C, DWhere is it used?Typical service: Centralized display and alarming in critical multipoint gas monitoring; Gas and flame detection systems in Division 2 potentially hazardous areas; Plant integration via Modbus TCP, Ethernet gateway protocols, and RS-485; Remote sensor installations using push-button zero/span Cal Mode.How is it configured?The 8800 is configured to order. Verified option groups include enclosure (NEMA 4X non-metallic, 316 stainless steel, explosion-proof, or rack/panel mount), power supply (150 W or 600 W options), input option cards, 4-20mA output cards, and discrete and programmable alarm relay cards; its HORN relay and Relay Acknowledge feature support external audible alarm devices.How do I order or get a quote?PE Energy supplies the Teledyne Detcon Model-8800 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 8864 Multi-Channel Gas Controller
What is the Teledyne Detcon Model-8864?The Teledyne Detcon Model-8864 is: Multi-channel gas detection controller, configured to order. The Teledyne 8864 controller provides simultaneous display and alarm functions for up to 64 input variables, with 16, 32, 48, and 64 channel display modes and I/O modules arranged in groups of 16 channels for economical system configuration. It shares its user interface with the 16-channel 8800 controller, making mixed installations straightforward. A QVGA color LCD presents trends, bar graphs, zone screens, and engineering units with alarm color coding, and a standard magnetic keypad allows non-intrusive operation in potentially hazardous locations.Key specificationsUp to 64 input channels; input types include 12-bit 4-20mA (150 ohm impedance), Modbus, and wireless optionsThree independent alarm levels per channel with Relay Acknowledge silencing of external audible devicesFive standard SPDT 5 A alarm relays: HORN, FAULT, and three programmable alarm relaysEthernet Modbus TCP master/slave port with web server; RS-485 serial ports for simultaneous Modbus master/slave operation (two standard, two optional isolated)Option cards: 16-bit 4-20mA outputs, 4-20mA inputs, discrete and programmable alarm relays, and 12-bit 16-channel bridge sensor inputsQVGA 320 x 240 TFT color LCD; SD card data logger records minimum, maximum, and average values for one yearPower 10-30 VDC (24 VDC nominal), 12 W max; power supply options include 150 W (10-0172) and 600 W (10-0307)Enclosures: wall mount NEMA 4X non-metallic, 316 stainless steel, explosion-proof (XP), and rack/panel mount; approvals CSA C22.2 No 1010.1, C22.2 No 152 for combustibles, ISA S82.02, UL 1604 / C22.2 No 213 (NEMA 4X = Division 2 Groups A, B, C, D), EN55011 and EN61000 (CE Mark)Where is it used?Typical service: Large multipoint gas and flame monitoring systems up to 64 channels; Centralized alarm and display functions across up to eight zones; Gas detection in Division 2 potentially hazardous areas; Plant integration via Modbus TCP, Ethernet gateways, RS-485, and wireless inputs.How is it configured?The 8864 is configured to order. Verified option groups include enclosure (NEMA 4X non-metallic, 316 stainless steel, explosion-proof, or rack/panel mount), power supply (150 W or 600 W options), input option cards including bridge sensor inputs, 4-20mA output cards, and discrete and programmable alarm relay cards; its HORN relay and Relay Acknowledge feature support external audible alarm devices.How do I order or get a quote?PE Energy supplies the Teledyne Detcon Model-8864 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 949-005142-200 Drop-in X40 Control Assembly with bezel
$1,540.00What is the Teledyne Detcon 949-005142-200?The Teledyne Detcon 949-005142-200 is: Drop-in X40 Control Assembly with bezel. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.Key specificationsX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Power supplies: 150 W 24 VDC option (10-0172) and 600 W option offered for the 8800 and 8864 controllers; 50 W NEMA 4X Division 2 (10-0315) and NEMA 7 Division 1 (10-0314) supplies for the 7000-series controllersDiscrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 949-005142-200 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 954-R20260-000 NEMA 4X Remote I/O Module Enclosure includes 75 watt power supply, for use with up to 8
$2,185.00What is the Teledyne Detcon 954-R20260-000?The Teledyne Detcon 954-R20260-000 is: NEMA 4X Remote I/O Module Enclosure includes 75 watt power supply, for use with up to 8. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.About the Teledyne Detcon Model X40 Controller line8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterStackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 954-R20260-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 954-X32020-000 Model X40-32-N4X, integrated alarm and control system in wall mount weatherproof Stainless Steel enclosure w/
$6,675.00Model X40-32-N4X, integrated alarm and control system in wall mount weatherproof Stainless Steel enclosure w/ 110/220 VAC 24 VDC pwr supply for 32 sensors. Does not include optional I/O modules (Accepts a maximum of 15). Part number 954-X32020-000 belongs to the Teledyne Gas and Flame Detection (Detcon) X40 Controller product line. List price $6,675.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon 954-X32020-001-401 Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays, 320 series radio
$10,005.00Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays, 320 series radio, 10 meter antenna separation. Part number 954-X32020-001-401 belongs to the Teledyne Gas and Flame Detection (Detcon) SmartWireless X40 product line. List price $10,005.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon 954-X32020-001-501 Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays
$11,145.00Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays, Qty 2 320 series radios (one radio for remote display communication). Part number 954-X32020-001-501 belongs to the Teledyne Gas and Flame Detection (Detcon) SmartWireless X40 product line. List price $11,145.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon 954-X32030-000 Model X40-32-N4X, integrated alarm and control system in wall mount BBU
$7,675.00Model X40-32-N4X, integrated alarm and control system in wall mount BBU, Stainless Steel weatherproof enclosure w/ 110/220 VAC 24 VDC pwr supply for 32 sensors, with Battery Back Up. Does not include optional I/O modules (Accepts a maximum of 15). Part number 954-X32030-000 belongs to the Teledyne Gas and Flame Detection (Detcon) X40 Controller product line. List price $7,675.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon 954-X32030-001-401 Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays, 320 series radio
$11,005.00Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays, 320 series radio, 10 meter antenna separation, with battery backup. Part number 954-X32030-001-401 belongs to the Teledyne Gas and Flame Detection (Detcon) SmartWireless X40 product line. List price $11,005.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon 954-X32030-001-501 Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays
$12,155.00Model SW-X40 Controller N4X Stainless Steel Enclosure with 3 relays, Qty 2 320 series radios (one radio for remote display communication), with battery backup. Part number 954-X32030-001-501 belongs to the Teledyne Gas and Flame Detection (Detcon) SmartWireless X40 product line. List price $12,155.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon 95P-X32000-000 Model X40-32-N1P, general purpose panel mount hardware assembly, 110/220 VAC, 24 VDC power
$4,705.00What is the Teledyne Detcon 95P-X32000-000?The Teledyne Detcon 95P-X32000-000 is: Model X40-32-N1P, general purpose panel mount hardware assembly, 110/220 VAC, 24 VDC power supply (up to 32 active channels). The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 95P-X32000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 95R-X32000-000 110/220 VAC 24 VDC pwr supply for 32 sensors Does not include optional I/O
$5,240.00What is the Teledyne Detcon 95R-X32000-000?The Teledyne Detcon 95R-X32000-000 is: 110/220 VAC 24 VDC pwr supply for 32 sensors Does not include optional I/O. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 95R-X32000-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 975-041400-000 Detcon Model RL-4 four relay alarm module
$545.00What is the Teledyne Detcon 975-041400-000?The Teledyne Detcon 975-041400-000 is: Detcon Model RL-4 four relay alarm module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-041400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 975-041401-000 Detcon Model AO-4 four channel analog output module
$545.00What is the Teledyne Detcon 975-041401-000?The Teledyne Detcon 975-041401-000 is: Detcon Model AO-4 four channel analog output module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-041401-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 975-041402-000 Detcon Model DI-4 four channel dry contact input module
$545.00What is the Teledyne Detcon 975-041402-000?The Teledyne Detcon 975-041402-000 is: Detcon Model DI-4 four channel dry contact input module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-041402-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 975-424408-110 Nema 4X weatherproof 24 VDC 17 amp hour battery supply with line charger
$3,059.00What is the Teledyne Detcon 975-424408-110?The Teledyne Detcon 975-424408-110 is: Nema 4X weatherproof 24 VDC 17 amp hour battery supply with line charger. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-424408-110 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 975-424600-110 Nema 4X weatherproof 24 VDC 25 amp hour battery supply with line charger
$4,213.00What is the Teledyne Detcon 975-424600-110?The Teledyne Detcon 975-424600-110 is: Nema 4X weatherproof 24 VDC 25 amp hour battery supply with line charger. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 975-424600-110 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-0003BC-00T Battery Charger / Cord
$510.00What is the Teledyne Detcon 976-0003BC-00T?The Teledyne Detcon 976-0003BC-00T is: Battery Charger / Cord. Genuine Teledyne Detcon input, output, relay, alarm, and power supply modules for the Detcon controller lines, including the 7200 Plus, 7400 Plus, 8800, 8864, and Model X40 alarm and control systems. The range covers plug-in option boards such as 4-20mA analog input, Wheatstone bridge sensor input, 4-20mA output, and discrete relay boards, along with DIN-rail I/O modules, audible and visual alarm devices, and AC-to-DC power supplies. These factory parts allow controllers to be expanded, reconfigured, or repaired in the field.About the Teledyne Detcon Controller Modules & Spares lineX40 I/O modules: DA-4 four-channel 4-20mA input, RL-4 four-relay alarm output, AO-4 four-channel 4-20mA output, DI-4 four-channel dry contact input, all individually addressable on 11.5-30 VDC7200 Plus option boards: dual 4-20mA input (10-0221/Dual), dual bridge sensor input (10-0219), six-relay discrete alarm board with 5 A Form C relays (10-0222), dual 4-20mA output (10-0223)7400 Plus option boards: quad 4-20mA analog input (10-0221/Quad), bridge sensor / 4-20mA input (10-0309), 4-20mA output (10-0308), discrete relay board (10-0222)Communication options: RS-232 / RS-485 Modbus RTU addressable interface (10-0253) and 10-baseT Ethernet with Modbus TCP (10-0224)Alarm devices: 100 dB piezo audible alarm (10-0337)Discrete relay contacts rated 5 A at 28 VDC or 250 VAC resistiveWhere is it used?Typical service: Field expansion of Detcon controller channel counts and I/O; Replacement of failed input, output, relay, or power supply boards; Adding Modbus serial or Ethernet communication to installed controllers; Adding local audible and visual alarm annunciation.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-0003BC-00T on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. -

Teledyne Detcon 976-041400-000 Detcon Model DA-4 four channel 4-20 maDC input module
$545.00What is the Teledyne Detcon 976-041400-000?The Teledyne Detcon 976-041400-000 is: Detcon Model DA-4 four channel 4-20 maDC input module. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-041400-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon 976-485485-000 RS-485 Isolated Repeater, 9-30VDC
$680.00What is the Teledyne Detcon 976-485485-000?The Teledyne Detcon 976-485485-000 is: RS-485 Isolated Repeater, 9-30VDC. The Teledyne Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and other field devices using 4-20mA DC or serial RS-485 Modbus inputs. It is available in two packages: the X40-8, which powers up to 8 field devices and houses up to six 4-channel I/O modules, and the X40-32, which powers up to 32 field devices and houses up to twelve 4-channel I/O modules. The system is completely field programmable with a hand-held magnet, displays real-time readings and status for up to eight devices at a time on a backlit LCD, and supports a wireless option using RXT-320 SmartWireless transceivers.Key specifications8 to 32 channel capacity, analog 4-20mA or RS-485 Modbus inputs, functions as Modbus MasterEnclosure options: NEMA 4X corrosion-resistant weatherproof wall mount, NEMA 1 panel mount, and NEMA 7 (Class I, Division 1, Group C, D)Stackable DIN-rail I/O modules: DA-4 4-channel 4-20mA input, RL-4 4-alarm relay output, AO-4 4-channel 4-20mA output, DI-4 4-relay contact inputOutput options: 4-20mA DC, RS-485 Modbus, and relay contacts1 1/8 in x 5 3/4 in backlit LCD with alarm status LEDs, display accuracy plus or minus 1% of full scalePower input 115-230 VAC or 11.5-30 VDC; controller consumption under 0.25 W excluding modules and field devicesOperating temperature -20 C to +70 C, 0-99% RH non-condensingSmartWireless capable with RXT-320 transceivers; extensive event data logging; CE Marking on X40-N4X and X40-SS modelsWhere is it used?Typical service: Oil and gas drilling rigs, production sites, and offshore platforms; Refining and petrochemical plants; Wastewater treatment plants; Food and beverage processing, pulp and paper mills.How do I order or get a quote?PE Energy supplies the Teledyne Detcon 976-485485-000 on a quote basis: submit a request with your part number and application details and our team returns pricing and lead time. Detcon fixed gas detection is quoted rather than sold at list price because most items ship configured for gas type, range, and area classification. This part belongs to the same product line as the Model X40 alarm and control system we carry. -

Teledyne Detcon DET-975-041400-000 Model RL4 relay module
$545.00Model RL4 relay module. Part number DET-975-041400-000 belongs to the Teledyne Gas and Flame Detection (Detcon) Spare parts product line. List price $545.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon DET-975-041401-000 Model AO-4 four channel analog output module
$545.00Model AO-4 four channel analog output module. Part number DET-975-041401-000 belongs to the Teledyne Gas and Flame Detection (Detcon) Spare parts product line. List price $545.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon DET-975-041402-000 Model DI-4 four channel dry contact input module
$545.00Model DI-4 four channel dry contact input module. Part number DET-975-041402-000 belongs to the Teledyne Gas and Flame Detection (Detcon) Spare parts product line. List price $545.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon DET-976-041400-000 Model DA-4 four channel 4-20 maDC input module
$545.00Model DA-4 four channel 4-20 maDC input module. Part number DET-976-041400-000 belongs to the Teledyne Gas and Flame Detection (Detcon) Spare parts product line. List price $545.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon DET-980-NTNT40-030 10 meter Antenna cable for X40 controller
$590.0010 meter Antenna cable for X40 controller. Part number DET-980-NTNT40-030 belongs to the Teledyne Gas and Flame Detection (Detcon) Spare parts product line. List price $590.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Browse all Detcon products on the PE Energy Detcon brand page. -

Teledyne Detcon Model X40 Integrated Alarm And Control System
Model X40 is a low power alarm and control system designed to monitor multiple gas detection sensors and/or a wide range of other field devices. The versatile control system is designed to receive and supervise inputs using either 4-20mA DC or Serial RS-485 Modbus™ and is available in two packages: Model X40-8 and Model X40-32. Both packages function as a Modbus™ Master and can be customized and expanded based on individual application needs using the stackable din-rail mounted I/O modules. All I/O modules are individually addressable and operate on 11.5-30VDC. The X40-8 provides power for up to eight field devices and can house up to six 4-channel I/O modules. The Model X40-32 provides power for up to 32 field devices and can house up to 12 4-channel I/O modules. The I/O modules available for use with the Model X40 include a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). The modules can be mounted within the main system enclosure or installed remotely to simplify field wiring. The Model X40 is completely field programmable using a small handheld magnet and offers advanced technology with intuitive, embedded intelligence. The control system displays real-time readings and field device status on a backlit LCD screen. During normal operation, the screen displays the alarm status and current reading (i.e., channel number, gas type, and gas concentration) for up to eight field devices simultaneously. The display is sequential and during normal operation it auto cycles through each of the active channel screens. Among the system’s unique features is a wireless option that can be used with RXT-320 SmartWireless® transceivers. Enclosure options include: NEMA 4X, NEMA 1 panel mount, and NEMA 7. Features 8 to 32 channel capacity Backlit LCD screen display Analog or RS-485 input options Easy intuitive field configuration Wire or distributed I/O Extensive event data logging SmartWireless® capable Applications Oil and gas drilling rigs Oil and gas production sites Offshore production platforms Wastewater treatment plants Food and beverage processing Pulp and paper mills Refining and petrochemical SYSTEM SPECIFICATIONS System Capacity Model X40-32-N1P: Up to 32 field devices Model X40-8-N4X: Up to 8 field devices Model X40-32-N4X: Up to 32 field devices Model X40-32-N7: Up to 32 field devices (analog or serial) Indicators 1 1/8” by 5 3/4” backlit LCD Alarm status LEDs Display Accuracy ±1% of full scale value Input Options Analog 4-20 mA DC RS-485 Modbus™ *(Only compatible with other Detcon products) Relay Contacts Output Options 4-20 mA DC RS-485 Modbus™ Relay Contacts Safety Approvals CE Marking (Models X40-N4X & X40-SS) Warranty One Year ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range -4ºF to + 158ºF, -20ºC to + 70ºC Storage Temperature Range -40ºF to + 185ºF, -40ºC to + 85ºC Operating Humidity Range 0-99% RH non-condensing MECHANICAL SPECIFICATIONS Dimensions Model X40-32-N1P: 10.5”W x 8”H x 12”D Model X40-8-N4X: 12”W x 14”H x 7.75”D Model X40-32-N4X: 16”W x 17.85”H x 9.5”D Model X40-32-N7: 11”W x 9.15”H x 2.75”D Weight Model X40-32-N1P: 10 lbs Model X40-8-N4X: 10 lbs Model X40-32-N4X: 20 lbs Model X40-32-N7: 10 lbs ELECTRICAL OPTIONS Power Input 115-230 VAC* or 11.5-30 VDC * Option for Model X40-32-N7 Power Consumption <0.25 Watt (I/O module power consumption not included) (Field device power consumption not included) Electrical Classification Model X40-32-N1P: NEMA 1 Panel Mount Model X40-8-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N4X: NEMA 4X Corrosion resistant weatherproof Model X40-32-N7: NEMA 7 Class I; Division 1, Group C, D Order Guide PN 95P-X32000-000 Model X40-32-N1P, General purpose panel mount hardware assembly 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 954-X08000-000 Model X40-8-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 8 active channels). PN 954-X32000-000 Model X40-32-N4X, Wall mount ABS weatherproof enclosure 110/220 VAC, 24 VDC power supply (up to 32 active channels). PN 957-X32000-000 Model X40-32-N7, Div 1 weatherproof enclosure 24 VDC power* for use in distributed I/O installations only (up to 32 active channels). Product Data Sheet