PE Energy supplies Det-Tronics optical flame detectors and gas detection controllers for oil & gas and industrial fire-and-gas systems — the X3301 multispectrum IR (IR3), the X5200 UV/IR, the X9800 single-frequency IR, the X2200 UV detector, and the Eagle Quantum Premier / EQ-series controllers and modules. See the flame detection systems selection guide to choose a detector by sensing technology, then request a quote.
Showing 1–45 of 88 results
-

Det-Tronics Duct-Mounting Kits for PointWatch Eclipse Model PIRECL
The Direct Duct Mount Assembly (p/n 007525-XXX series) (Spec Sheet: 90-1151) is FM approved for use with PointWatch Eclipse model PIRECL to be installed directly within air handling ductwork. The assembly is mounted on the duct wall, with the PIRECL sensing chamber exposed directly to duct airflow, ensuring fast response to Methane. A built-in calibration gas nozzle with an external, self-sealing fitting enables testing and calibration without removal of the detector from the duct. Not recommended for applications where duct air temperatures can exceed 167 °F (75 °C). Price includes all necessary hardware for proper operation, but does not include the PointWatch Eclipse PIRECL gas detector. A factory pre-assembled Direct Duct Mount Kit is available (p/n 007529-XXX series) that provides a PIRECL detector prefit into the Direct Duct Mount kit assembly. Pricing for the 007529-XXX assembly includes the PIRECL gas detector. The Direct Duct Mount Assembly complies to the ANSI/ISA-12.13.01-2000 performance standards. Direct Duct Mount Kits (PIRECL not included) Part Number Mount Material Ship Weight 007525-003 Vertical 316 SS 3.5 lb (1.6 kg) 007525-004 Vertical Aluminum 1 lb (0.46 kg) 007525-005 Horizontal 316 SS 3.5 lb (1.6 kg) 007525-006 Horizontal Aluminum 1 lb (0.46 kg) *Use PIRECL with standard baffle. Direct Duct Mount Assemblies Part Number Mount PIRECL Model PIRECL Output Hart Port Material 014101-410 Vertical PIRECLA11D3T1 4-20 mA X 316 SS 014101-440 Vertical PIRECLB11D3T1 4-20 mA X 316 SS 014101-416 Vertical PIRECLA14D3T1 EQP X 316 SS 014101-417 Vertical PIRECLB14D3T1 EQP X 316 SS 007529-903 Vertical PIRECLA4A3R1 EQP X 316 SS 007529-908 Horizontal PIRECLA4A3R1 EQP X 316 SS 007529-909 Vertical PIRECLB1A3R1 4-20mA X 316 SS Ship Weight 15 lb (6.8 kg) -

Det-Tronics Eagle Quantum Premier Controller EQ30XX
Eagle Quantum Premier Controller EQ30XX (Spec Sheet: 90-1148) The Eagle Quantum Premier Controller is a microprocessor-based module that performs all the communication and control functions for the system. The controller can be configured in a simplex or redundant mode of operation. It includes all the required operator interface controls for a fire alarm and releasing system. Fire detection and alarm Fire suppression control Gas detection and alarm Available in certified enclosures Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to FM 6310/6320 Performance certified to ATEX/IEC 60079-29-1 Simplex or redundant operation Models with SIL 2 certification Programmable logic Optional Dual Ethernet Ports (Modbus TCP/IP) Multiple serial ports (three RS-232 and two RS-485) Transformer isolation of network ports Utilizes Modbus RTU, Modbus TCP/IP, or Allen Bradley protocols ControlNet Interface (Optional DRL Device level ring EtherNet DLR) Eight Programmable Relay Outputs Dedicated Fault Output Eight Digital Inputs Four-line, 20-character alphanumeric display LED status indicators Fault-tolerant communication loop Extensive built-in diagnostics Real-time clock Compact design US Coast Guard type approval. Lloyd’s Register Type Approval. EQ30XX Model Matrix MODEL DESCRIPTION EQ3001 Eagle Quantum Premier Controller - 246 Nodes EQ3016 Eagle Quantum Premier Controller - 16 Nodes TYPE MOUNTING OPTION D Din Rail P Panel TYPE COM BOARD 1 N None C ControlNet D EtherNet DLR TYPE COM BOARD 2 N None D Ethernet IP with DLR E Ethernet IP S Serial Port Expansion TYPE APPROVALS* R VNIIPO/VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/IECEx *Type Approvals can use one or more letters to designate the approvals of the product. EQ3001 Controller - SIL 2 Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port SIL/FM/CSA/ ATEX/IECEx EQ3001PNNT 007609-072 Panel X EQ3001DNNT 007609-073 DIN X EQ3001PCNT 007609-075 Panel X X EQ3001DCNT 007609-076 DIN X X EQ3001PNET 007609-086 Panel X X X EQ3001DNET 007609-087 DIN X X X EQ3001PCET 007609-088 Panel X X X X EQ3001DCET 007609-089 DIN X X X X EQ3001PNST 007609-077 Panel X X EQ3001DNST 007609-078 DIN X X EQ3001PCST 007609-079 Panel X X X EQ3001DCST 007609-080 DIN X X X EQ3001DDET 007609-189 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) EQ3016 Controller - SIL 2 Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port SIL/FM/CSA/ ATEX/IECEx EQ3016PNNT 007609-472 Panel EQ3016DNNT 007609-473 DIN EQ3016PCNT 007609-475 Panel X EQ3016DCNT 007609-476 DIN X X EQ3016PNET 007609-486 Panel X X X EQ3016DNET 007609-487 DIN X X X EQ3016PCET 007609-488 Panel X X X X EQ3016DCET 007609-489 DIN X X X X EQ3016PNST 007609-477 Panel X X EQ3016DNST 007609-478 DIN X X EQ3016PCST 007609-479 Panel X X X EQ3016DCST 007609-480 DIN X X X EQ3016DDET 007609-689 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) EQ3001 Controller Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port FM/CSA/ ATEX/IECEx EQ3001PNNW 007609-062 Panel X EQ3001DNNW 007609-063 DIN X EQ3001PCNW 007609-065 Panel X X EQ3001DCNW 007609-066 DIN X X EQ3001PNEW 007609-082 Panel X X X EQ3001DNEW 007609-083 DIN X X X EQ3001PCEW 007609-084 Panel X X X X EQ3001DCEW 007609-085 DIN X X X X EQ3001PNSW 007609-067 Panel X X EQ3001DNSW 007609-068 DIN X X EQ3001PCSW 007609-069 Panel X X X EQ3001DCSW 007609-070 DIN X X X EQ3001PCSW-C* 007609-269 Panel X X X EQ3001DDEW 007609-185 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) *US Coast Guard type approval under 46 CFR 161.002. For use with USCG approved system only. EQ3016 Controller Model Part Number Mounting ControlNet Ethernet Ethernet/ IP DLR Serial Port Expansion/ Redundancy Port FM/CSA/ ATEX/IECEx EQ3016PNNW 007609-462 Panel X EQ3016DNNW 007609-463 DIN X EQ3016PCNW 007609-465 Panel X X EQ3016DCNW 007609-466 DIN X X EQ3016PNEW 007609-482 Panel X X X EQ3016DNEW 007609-483 DIN X X X EQ3016PCEW 007609-484 Panel X X X X EQ3016DCEW 007609-485 DIN X X X X EQ3016PNSW 007609-467 Panel X X EQ3016DNSW 007609-468 DIN X X EQ3016PCSW 007609-469 Panel X X X EQ3016DCSW 007609-470 DIN X X X EQ3016PNNW-C* 007609-282 Panel X EQ3016DDEW 007609-685 DIN X X X X Ship Weight: 5.0 lb (2.3 kg) *US Coast Guard type approval under 46 CFR 161.002. For use with USCG approved system only. Redundancy Parts Part Number* Description Ship Weight 008981-001 Controller to Controller High Speed Serial Cable (4 ft) 1.0 lb (0.45 kg) 008982-001 EQ3LTM LON Termination Module (2 required per LON) 1.0 lb (0.45 kg) *Parts can only be used with EQP Controllers with serial port expansion option. Controller Communication Cables Part Number Description Length Ship Weight 15 ft. (4.57 m) 30 ft. (9.14m) 50 ft. (15.24m) 007633-001 Controller RS-232 Cable (DB9 Female PC Connection) X 1.0 lb (0.45 kg) 007633-002 Controller RS-232 Cable (DB9 Female PC Connection) X 1.0 lb (0.45 kg) 007633-003 Controller RS-232 Cable (DB9 Female PC Connection) X 1.6 lb (0.7 kg) Typical Order for a Redundant System Qty Part Number Description 2 007609-078 EQ3001DNST Controller 1 008981-001 Controller to Controller redundancy High Speed Serial Cable (4 ft) 2 008982-001 EQ3LTM LON Termination Module (2 required per LON) Interface Hardware RS 485 and Hart Part Number Description Ship Weight 014008-001 EQ2230RSP Surge Protector RS485 1.0 lb (.45 kg) 008056-001 HIM, HART Interface Module, EQP 1.0 lb (.45 kg) Which other Eagle Quantum Premier Controller EQ30XX part numbers can PE Energy supply?The 8 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description007609-184EQ3001PDEW EQP CONTROLLER007609-262EQ3001PNNW-C EQP CONTROLLER007609-277EQ3001PNST-C EQP CTRL,SIL007609-783EQ3016DNEK EQP CONTROLLER007609-784EQ3001DNEK EQP CONTROLLER007609-909EQ3001DDER EQP CONTROLLER007609-950EQ3016DCSSR,EQP CONTROLLER,SIL007609-963EQ3001DNNR, EQP CONTROLLER -

Det-Tronics EQ3760 Addressable Smoke Module
The EQP Addressable Smoke Module (Spec Sheet: 90-1226) is designed to expand the input and output capability of the Det-Tronics EQP system. The ASM is an interface device designed to provide continuous and automated fire protection. It ensures system operation through continuous supervision of system inputs/outputs and Local Operating Network/Signaling Line Circuit (LON/SLC) monitoring in the controller. The ASM is located directly on the LON of the EQP system, with a loop of up to 100 addressable devices tied into the ASM. This allows the EQP controller to annunciate a fire alarm from either its own LON based I/O or from the ASM connected addressable smoke and heat detection loops. System status can be determined using the troubleshooting procedures, Eagle Quantum Safety System Software (S3), and the status indicators on the module. Expands the capabilities of the Det-Tronics EQP system Class 1 Div. 2 locations combined with Zone 2 rated devices Type N SIL 2 Capable certification Provides power and communications to 100 addressable devices Uses Apollo Discovery and XP95 smoke and heat detectors ASM alarm and fault status are logged in the EQP controller LEDs for easy annunciation of power, faults and an active device on the loop Monitors single addressable devices Provides remote I/O capabilities via LON/SLC DIN rail or panel mounting Plug-in wiring connectors RFI and EMI hardened Smoke detectors are globally approved (see product data sheets) Option Intrinsically Safe detectors EQ3760 ASM Model Matrix MODEL DESCRIPTION EQ3760 Addressable Smoke Module (ASM) TYPE MOUNTING OPTION D DIN Rail P Panel TYPE APPROVALS T FM/CSA/ATEX/IECEx EQ3760 ASM Module Model Part Number Material FM/CSA/ATEX/IECEx Ship Weight EQ3760DT 014050-001 AL X 3 lb (1.4 kg) EQ3760PT 014050-002 AL X 3 lb (1.4 kg) Devices for EQ3760 ASM Module Model Part Number Material APOLLO IONIZATION SMOKE, EU 000515-501 58000-500 APOLLO OPTICAL SMOKE, EU 000515-502 58000-600 APOLLO HEAT DETECTOR, EU 000515-503 58000-400 APOLLO MULTISENSOR, EU 000515-504 58000-700 APOLLO CO DETECTOR, EU 000515-505 58000-300 APOLLO INTELLIGENT MNT BASE,EU 000515-506 45681-210 APOLLO ISOLATING BASE 000515-507 45681-284 APOLLO INTELLIGENT ISOLATOR 000515-508 55000-720 APOLLO I/O UNIT W/ ISOLATOR 000515-509 55000-847 APOLLO SOUNDER CONTROL UNIT 000515-510 55000-852 APOLLO SWITCH MONITOR PLUS 000515-511 55000-841 APOLLO MANUAL CALL W/ISOLATOR 000515-512 58100-908 APOLLO MANUAL CALL, W/ISO,IP66 000515-513 58100-951 APOLLO MANUAL CALL COVER 000515-514 26729-152 APOLLO SOUNDER, 100DB, RED 000515-515 55000-278 APOLLO SOUNDER,100DB,RED,IP66 000515-516 55000-274 APOLLO BEACON,RED 000515-517 55000-877 APOLLO SOUNDER/BEACON, W/ISO 000515-518 55000-293 APOLLO INTELLIGENT ISOLATOR BA 000515-519 45681-211 APOLLO BLANK ADDRESS CARD 000515-521 38531-771 APOLLO IONIZATION SMOKE, NA 000515-551 58000-550 APOLLO OPTICAL SMOKE, NA 000515-552 58000-650 APOLLO HEAT DETECTOR, NA 000515-553 58000-450 APOLLO MULTISENSOR, NA 000515-554 58000-750 APOLLO MOUNTING BASE 4",NA 000515-555 45681-210USA APOLLO MOUNTING BASE 6",NA 000515-556 45681-225USA APOLLO ISOLATOR, NA 000515-557 55000-750 APOLLO ISOLATOR BASE, NA 000515-558 45681-211USA APOLLO PRIORITY SWITCH MONITOR 000515-559 55000-806 APOLLO SOUNDER CONTROL MOD,NA 000515-560 55000-825 APOLLO I/O MODULE, NA 000515-561 55000-820 APOLLO MINI MONITOR MOD, NA 000515-562 55000-765 APOLLO INTELLIGENT DEEP BASE 000515-563 45681-209 EU = European Approvals NA = North American Approvals NOTE: Average lead time is 4 weeks. For additional options please consult the factory. Compatibility list of products for ASM Description Part Number Apollo Part # Apollo Heat Detector 000515-XXX 5800-400 Apollo Heat Detector, EU Marine 000515-611 58000-400MAR Apollo Heat, IS ** 000515-585 55000-440 Apollo Heat Detector, SIL2 000515-XXX 58000-400SIL Apollo Heat Detector, FM 000515-553 58000-450 Apollo Ionization Smoke, EU 000515-501 58000-500 Apollo Ionization Smoke, Marine 000515-XXX 58000-500MAR Apollo Smoke, EU Marine Optical 000515-XXX 58000-600MAR Apollo Smoke, SIL2 Optical 000515-645 58000-600SIL Apollo Ionization Smoke, IS ** 000515-XXX 58000-540 Apollo Smoke, IS Optical ** 000515-XXX 58000-640 Apollo Ionization Smoke, FM 000515-551 58000-550 Apollo Optical Smoke Detector, FM 000515-552 58000-650 Apollo Duct Smoke Det. Base EU 000515-550 53546-022 Apollo Multisensor, EU Marine 000515-XXX 58000-700MAR Apollo Multisensor, EU 000515-504 58000-700 Apollo Multisensor, SIL2 000515-637 58000-700SIL Apollo Multisensor, FM 000515-554 58000-750 Apollo Carbon Monoxide Detector, EU 000515-505 58000-300 Apollo Input / Output Unit, with Isolator 000515-509 55000-847 Apollo Manual Call, with Isolator 000515-512 58100-908 Apollo Manual Call, with Isolator, IP66 000515-513 58100-951 Apollo Beacon, Red 000515-517 55000-877 Apollo Isolator, FM 000515-557 55000-750 Apollo XP95A Priority Switch Monitor, FM 000515-559 55000-806 Apollo XP95A Sounder Control Module, FM 000515-560 55000-825 Apollo XP95A Input / Output Module, FM 000515-561 55000-820 Apollo Mounting Base, Marine 000515-XXX 45681-210MAR Apollo Mounting Base, IS 000515-586 45681-215 Apollo Isolator Base, Marine 000515-XXX 45681-211MAR Apollo Relay Base, EU 000515-XXX 45681-242 Apollo Manual Call Point, Standard, Non-Isolated, Waterproof, IS ** 000515-581 55000-940 Apollo Manual Call Point, Break Glass, Non-Isolated, Waterproof IS ** 000515-677 55000-960 Apollo Manual Call Point, Push Button, Non-Isolated, Waterproof, IS ** 000515-617 55000-970 Apollo Manual Call, Standard, Non-Isolated, Non-Waterproof, EU 000515-XXX 55200-910 Apollo Manual Call, Standard, Non-Isolated, Waterproof, EU 000515-XXX 55200-950 Apollo Manual Call, Standard, Isolated, Waterproof, Marine 000515-XXX 58200-971MAR Apollo Manual Call, Standard, Isolated, Non-Waterproof, SIL2 000515-XXX 58200-908SIL Apollo Remote Led 1 Gang Red 000116-180 53832-070 Apollo Sounder Control Unit 000515-510 55000-852 Apollo Sounder, 100dB, Red 000515-515 55000-278 Apollo Sounder / Beacon, with Isolator 000515-518 55000-293 Apollo Sounder, 100dB, Red, IP66 000515-516 55000-274 Apollo Sounder XP95a, Isolated, Non-Weatherproof, UL 000515-XXX 55000-041 Apollo Sounder Beacon Discovery, Non-Isolated, Non-Weatherproof, EU 000515-XXX 58000-005 Apollo Sounder Beacon XP95, Isolated, Waterproof, EU 000515-520 55000-298 Apollo Sounder Beacon Discovery, Non-Isolated, Weatherproof, Marine 000515-XXX 55000-374MAR Apollo Sounder Beacon Discovery, Non-Isolated, Weatherproof, UL 000515-XXX 58000-011 Apollo Sounder Beacon Discovery, Isolated, Weatherproof, Marine 000515-XXX 55000-398MAR Apollo Sounder Control, Din Rail, EU 000515-XXX 55000-182 Apollo Sounder Control, Din Rail, Marine 000515-XXX 55000-181MAR Apollo I/O, Din Rail, EU 000515-576 55000-803 Apollo I/O, Din Rail, Marine 000515-XXX 55000-774MAR Apollo 3 Channel I/O, Standard, EU 000515-XXX 55000-588 Apollo I/O, Standard, SIL2 000515-XXX 55000-847SIL Apollo Relay Output, Din Rail, EU 000515-XXX 55000-804 Apollo Relay Output, Din Rail, Marine 000515-XXX 55000-771MAR Apollo Switch Monitor Plus 000515-511 55000-841 Apollo Switch Monitor, Din Rail, EU 000515-675 55000-822 Apollo Switch Monitor Plus, Din Rail, Marine 000515-XXX 55000-772MAR Apollo Mini Switch Monitor, Mini, Marine 000515-XXX 55000-775MAR Apollo Zone Monitor, Standard, Eu 000515-XXX 55000-845 Apollo Zone Monitor, Din Rail, Eu 000515-575 55000-812 Apollo Zone Monitor, Din Rail, Marine 000515-XXX 55000-773MAR Apollo Vac I/O, Standard, FM 000515-XXX 55000-859 Apollo Is Protocol Translator, Sgl ** 000515-582 55000-855 Apollo Is Protocol Translator, Dbl ** 000515-583 55000-856 Apollo Is Galvanic Barrier ** 000515-XXX 29600-098 Apollo Isolator, Marine 000515-XXX 55000-721MAR Apollo Mini Monitor Module, NA or Apollo Priority Mini Switch Monitor, FM 000515-562 55000-765* The device type depends on the priority switch setting on the device. ** Not FM approved as non-interfering FM = FM Approved EU = European Approvals -

Det-Tronics Flame Detector Mounting Hardware
Q9001B (Manual: 95-8338) Aluminum swivel for positioning the C7050 and X7050. Q9001H (Manual: 95-8338) Stainless steel swivel for positioning the C7050 and X7050. Q9033A Aluminum Mounting Arm for all aluminum X-Series flame detectors. NOTE: For use with aluminum detectors only. Q9033B Stainless steel Mounting Arm for all X-Series flame detectors (DNV approved with X3301). NOTE: For use with stainless steel and aluminum detectors. Q9033 Collar Attachment (Manual: 95-8686) for all X-Series flame detectors . Used in conjunction with the Q9033A/B Mounting Arm. The Collar Attachment adds versatility to the mounted detector by allowing a wider (3-dimensional) range of motion and improved viewing angles (DNV approved with X3301). Q1130 (Manual: 95-8662) Flange mount assembly for X3301 and X3302, allows the detector to be mounted externally to monitor storage or process areas. Not suitable for Zone 0 defined locations. Flame Detector Mounting Hardware Model Part Number For Use With Ship Weight Q9001B1175 002099-003 AL C7050 and X7050 0.5 lb (0.23 kg) Q9001H8001 004404-002 SS C7050 and X7050 1 lb (0.45 kg) Q9033A1000 007290-002 AL X2200, X5200, X9800, X3301, X3302 6 lb (2.75 kg) Q9033B1000 007290-001 SS X2200, X5200, X9800, X3301, X3302 14 lb (6.4 kg) Q9033 Collar Attachment* 011385-001 Q9033A, Q9033B 2.05 lb (0.9 kg) Q9033 Collar Attachment† 011385-002 Q9033A, Q9033B 2.05 lb (0.9 kg) Q9033 Spare Lock Washer 103019-002 Q9033A, Q9033B 0.04lb (0.02 kg) Q9033A Spare M16 Top Screw 400525-018 Q9033A 0.2 lb (0.1 kg) Q1130A1001 010857-001 X3301, X3302 2.8 lb (1.3 kg) *Note: Screws that connect collar halves enter from the top †Note: Screws that connect collar halves enter from the bottom 4-Inch Pipe Mount Bracket and U-Bolt Kit (Specification Sheet 90-1227) This kit is used to install an X-Series flame detector and Q9033 mounting arm to a 4-inch pipe. This kit includes a pipe mount plate, all hardware for installing mounting arm to plate, and U-Bolts and hardware for attaching the pipe mount plate to a 4-Inch pipe. All materials are 316 Stainless Steel. 4-Inch Pipe Mount Bracket and U-Bolt Kit Model Part Number Ship Weight 4” Pipe Mnt Kit, SS, w/ Hardware 000609-026 2.5 lb (1.3 kg) 2-Inch U-Bolt Kit (Specification Sheet 90-1228) This kit is used to install an X-Series flame detector and Q9033 mounting arm to a 2-inch pipe. This kit includes two U-bolts, washers, lock washers, and hex nuts. All materials are 316 Stainless Steel 2-Inch Pipe Mount Bracket and U-Bolt Kit Model Part Number Ship Weight 2” Pipe Mt. U Bolt Kit 000609-035 0.75 lb (0.3 kg) Sun shade for X-Series Flame Detectors (Specification Sheet 90-1229)The sun shade installs between the wall, pole surface, or pole mount bracket and the Q9033 mounting arm providing the flame detector with protection from the sun and precipitation. Material is 316 Stainless Steel. Detector in photo below is shown installed on a 4-inch pole using the 4-Inch Pipe Mount Bracket and U-Bolt Kit (Part number 000609-026) which is not included with the Sun Shade. Sun shade for X-Series Flame Detectors Model Part Number Ship Weight Stainless Steel Sun Shade for X-Series Flame Detector 000003-067 5 lbs. (2.27 kg) -

Det-Tronics PM-5MPX Dual Spectrum Flame Detector
PM-5MPX Dual Spectrum Flame Detector (Spec Sheet: 90-1182) is optimized for the rigorous semiconductor fabrication industry, which is beset with many hazards that result in stringent and application-specific requirements for fire protection safety systems. Additionally, the PM-5MPX is well-suited for the detection of cutting oil fires within CNC machine grinding applications. Complies to FM wet bench performance standards Approved to FM3260: 2000 Dual spectrum IR design Compact size LED indicator for operational status Built-in mounting plate Typical response of <0.5 sec Fast response–-as fast as 25 milliseconds Polypropylene housing: excellent resistance to corrosion and contamination effects FM approved for intrinsic safety CE marked Highly resistant to false alarms May qualify for RoHS machine guarding exception PM-5MPX Dual Spectrum IR Flame Detector MODEL Part Number Encl Material Cable Length FM Ship Weight PM-5MPX 421132-001 Polypropylene 50 ft X 0.5 lb (0.23 kg) PM-5MPX Accessories Part Number Description Ship Weight 007351-001 PSS-ML Test Lamp <1 lb (<0.45 kg) -

Det-Tronics X2200 UV Flame Detector
X2200 UV Flame Detector (Spec Sheet: 90-1157) meets the most stringent requirements worldwide with advanced signal processing and immunity to extraneous sources, combined with Ultra-high speed capability. The detector is equipped with both automatic and manual oi (optical integrity). The detector has Division and Zone explosion-proof ratings and is suitable for use in a variety of applications. The standard output configuration includes fire, fault, and auxiliary relays with RS-485 Modbus. Optional 0-20 mA, Pulse, Eagle Quantum Premier, or HART outputs are also available. A model with pulse output is available for easy retrofitting into existing Det-Tronics R74XX controller based systems. The X2200 housing is available in aluminum or stainless steel, with NEMA/Type 4X and IP66/IP67 rating. Typical applications include: HVDC converter stations, munitions, sulfur production, and silane storage. Models available with SIL 2 certification ARC rejection - Advanced signal processing Unequaled false alarm rejection - Solar blind Responds to a fire in the presence of modulated blackbody radiation without false alarm Ultra-High speed capability Optional HART output and AMS aware Automatic, manual, or magnetic oi (optical integrity) testing Pulse output for compatibility with Det-Tronics R74XX controller-based systems (optional) FM, CSA, ATEX, CE, and IECEx EN 54 part 10 certified by BRE, LPCB Tricolor LED indicates normal operation, fire, and fault conditions Mounting arm allows easy sighting Integral wiring compartment for ease of installation Terminal block allows for Class X Pathway Designation per NFPA 72 EMI, RFI, EMC Directive Compliant Built-in data logging / event monitoring Models available with integral Explosion-proof camera option (xWatch) Molybdenum Model available for applications that require increased spectral sensitivity X2200 Model Matrix MODEL DESCRIPTION X2200 UV Flame Detector X2200G UV Flame Detector with Kr85 free Source Tube X2200M* UV Flame Detector with Molybdenum Tube X2200GM* UV Flame Detector with Molybdenum Tube, Kr85 free TYPE MATERIAL A Aluminum (AL) S Stainless Steel (SS) TYPE THREAD TYPE 3M 3 Port, M25† 3N 3 Port, 3/4" NPT† 4M 4 Port, M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 11 Relay 13 Relay and 0-20 mA 14 Eagle Quantum Premier 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23‡ HART, Relay, and 0-20 mA 24 Eagle Quantum 33 Relay and 0-20 mA / NTSC (xWatch) 34 Eagle Quantum Premier / NTSC (xWatch) 43 Relay and 0-20 mA / PAL (xWatch) 44 Eagle Quantum Premier / PAL (xWatch) TYPE APPROVALS§ A FM/CSA B INMETRO (BRAZIL) E ATEX/IECEx/EN 54-10 R VNIIPO/VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx U TCCExEE/UKRCEPRO (UKRAINE) W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION 1 Division/Zone Ex d e 2 Division/Zone Ex d *Special Application - consult factory before ordering. †3 port models are only available with output types 33, 34, 43, and 44 (xWatch) ‡Type 23 Output - When HART output chosen detector does not have RS-485 communication available. §Type Approvals can use one or more letters to designate the approvals of the product Table D1 - X2200 Software Part Number Configuration Matrix Dash UV Sensitivity Arc Rejection Alarm Relay Aux Output Function Aux Relay Fault Relay -001 High High De-Energized Non-latching Follows Alarm Energized Non-latching Energized Non-latching -002 High Very High De-Energized Non-latching Follows Alarm Energized Non-latching Energized Non-latching -003 High Off De-Energized Non-latching Pre-Alarm Energized Non-latching Energized Non-latching -005 Medium High De-Energized Non-latching Follows Alarm Energized Non-latching Energized Non-latching -006 High High De-Energized Non-latching Pre-Alarm Energized Non-latching Energized Non-latching -007 High High De-Energized Latching Follows Alarm De-energized Latching Energized Non-latching -008 High Very High De-Energized Latching Follows Alarm De-energized Latching Energized Non-latching -009 High Off De-Energized Latching Pre-Alarm De-energized Latching Energized Non-latching -010 Medium High De-Energized Latching Follows Alarm De-energized Latching Energized Non-latching -011 High High De-Energized Latching Pre-Alarm De-energized Latching Energized Non-latching -013* High Off De-Energized Non-latching Follows Alarm Energized Non-latching Energized Non-latching -014* High Off De-Energized Latching Follows Alarm De-Energized Non-latching Energized Non-latching -015 Very High Low De-Energized Non-latching Follows Alarm Energized Non-latching Energized Non-latching -016 Very High Low De-Energized Latching Follows Alarm De-Energized Non-latching Energized Non-latching -017 Very High Off De-Energized Non-latching Pre-Alarm Energized Non-latching Energized Non-latching -018 Very High Off De-Energized Non-latching Follows Alarm Energized Non-latching Energized Non-latching -019 Very High Off De-Energized Non-latching Pre-Alarm De-Energized Non-latching Energized Non-latching *Available only on the X2200M model ARC = Arc Rejection. An algorithm that prevents false alarms from transient UV sources Application Guidelines The following criteria should be considered when choosing a sensitivity level for the intended application: Speed of response based on fuel type and fire size Distance between the hazard and the flame detector These are typical industry application settings. They may not be applicable to all installations. Contact factory for additional application guidance. HVDC 019 Compressor 002 High Speed 003 Automotive 005 Turbine 006 Munitions 013/019 NOTE: Latching relays cannot be used in voted systems. X2200 UV Flame Detector - SIL 2 Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone SIL/FM/CSA/ ATEX/IECEx X2200A4N13T1 008430-XXX AL 3/4 NPT Relay/0-20 mA X X X2200A4M13T1 008431-XXX AL M25 Relay/0-20 mA X X X2200S4N13T1 008432-XXX SS 3/4 NPT Relay/0-20 mA X X X2200S4M13T1 008433-XXX SS M25 Relay/0-20 mA X X X2200A4N13T2 008434-XXX AL 3/4 NPT Relay/0-20 mA X X X2200A4M13T2 008435-XXX AL M25 Relay/0-20 mA X X X2200S4N13T2 008436-XXX SS 3/4 NPT Relay/0-20 mA X X X2200S4M13T2 008437-XXX SS M25 Relay/0-20 mA X X X2200A4N23T1 008438-XXX AL 3/4 NPT Rly/0-20/HART X X X2200A4M23T1 008439-XXX AL M25 Rly/0-20/HART X X X2200S4N23T1 008440-XXX SS 3/4 NPT Rly/0-20/HART X X X2200S4M23T1 008441-XXX SS M25 Rly/0-20/HART X X X2200A4N23T2 008442-XXX AL 3/4 NPT Rly/0-20/HART X X X2200A4M23T2 008443-XXX AL M25 Rly/0-20/HART X X X2200S4N23T2 008444-XXX SS 3/4 NPT Rly/0-20/HART X X X2200S4M23T2 008445-XXX SS M25 Rly/0-20/HART X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table D1 to choose the correct option. X2200 UV Flame Detector - Moly - SIL 2 The X2200M UV detector utilizes a molybdenum (moly) sensing element. Moly-based sensors have an increased spectral range of 1850 to 2650 angstroms, which is better suited for detecting substances with unusual chemistry, sulfur fires, and some black powders. Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d SIL/FM/CSA/ ATEX/IECEx X2200MA4N23T1 008446-XXX AL 3/4 NPT Rly/0-20/HART X X X2200MA4M23T1 008447-XXX AL M25 Rly/0-20/HART X X X2200MS4N23T1 008448-XXX SS 3/4 NPT Rly/0-20/HART X X X2200MS4M23T1 008449-XXX SS M25 Rly/0-20/HART X X X2200MA4N23T2 008450-XXX AL 3/4 NPT Rly/0-20/HART X X X2200MA4M23T2 008451-XXX AL M25 Rly/0-20/HART X X X2200MS4N23T2 008452-XXX SS 3/4 NPT Rly/0-20/HART X X X2200MS4M23T2 008453-XXX SS M25 Rly/0-20/HART X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) X2200 UV Flame Detector Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA/ ATEX/IECEx X2200A4N11W1 008300-XXX AL 3/4 NPT Relay X X X2200A4M11W1 008301-XXX AL M25 Relay X X X2200S4N11W1 008302-XXX SS 3/4 NPT Relay X X X2200S4M11W1 008303-XXX SS M25 Relay X X X2200A4N11W2 008304-XXX AL 3/4 NPT Relay X X X2200A4M11W2 008305-XXX AL M25 Relay X X X2200S4N11W2 008306-XXX SS 3/4 NPT Relay X X X2200S4M11W2 008307-XXX SS M25 Relay X X X2200A4N14W1 008316-001 AL 3/4 NPT EQP X X X2200A4M14W1 008317-001 AL M25 EQP X X X2200S4N14W1 008318-001 SS 3/4 NPT EQP X X X2200S4M14W1 008319-001 SS M25 EQP X X X2200A4N14W2 008320-001 AL 3/4 NPT EQP X X X2200A4M14W2 008321-001 AL M25 EQP X X X2200S4N14W2 008322-001 SS 3/4 NPT EQP X X X2200S4M14W2 008323-001 SS M25 EQP X X X2200A4N15W1 008324-XXX AL 3/4 NPT Pulse/Relay X X X2200A4M15W1 008325-XXX AL M25 Pulse/Relay X X X2200S4N15W1 008326-XXX SS 3/4 NPT Pulse/Relay X X X2200S4M15W1 008327-XXX SS M25 Pulse/Relay X X X2200A4N15W2 008328-XXX AL 3/4 NPT Pulse/Relay X X X2200A4M15W2 008329-XXX AL M25 Pulse/Relay X X X2200S4N15W2 008330-XXX SS 3/4 NPT Pulse/Relay X X X2200S4M15W2 008331-XXX SS M25 Pulse/Relay X X X2200A4N24W1 008356-001 AL 3/4 NPT Eagle Quantum X X X2200A4M24W1 008357-001 AL M25 Eagle Quantum X X X2200S4N24W1 008358-001 SS 3/4 NPT Eagle Quantum X X X2200S4M24W1 008359-001 SS M25 Eagle Quantum X X X2200A4N24W2 008360-001 AL 3/4 NPT Eagle Quantum X X X2200A4M24W2 008361-001 AL M25 Eagle Quantum X X X2200S4N24W2 008362-001 SS 3/4 NPT Eagle Quantum X X X2200S4M24W2 008363-001 SS M25 Eagle Quantum X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table D1 to choose the correct option. The EQ and EQP detectors are completely configurable using the configuration software and are shipped defaulted to the -001 setting. X2200M UV Flame Detector - Moly The X2200M UV detector utilizes a molybdenum (moly) sensing element. Moly-based sensors have an increased spectral range of 1850 to 2650 angstroms, which is better suited for detecting substances with unusual chemistry, sulfur fires, and some black powders. Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA/ ATEX/IECEx X2200MA4N13W1 008340-013 AL 3/4 NPT Relay/0-20 mA X X X2200MA4M13W1 008341-013 AL M25 Relay/0-20 mA X X X2200MS4N13W1 008342-013 SS 3/4 NPT Relay/0-20 mA X X X2200MS4M13W1 008343-013 SS M25 Relay/0-20 mA X X X2200MA4N13W2 008344-013 AL 3/4 NPT Relay/0-20 mA X X X2200MA4M13W2 008345-013 AL M25 Relay/0-20 mA X X X2200MS4N13W2 008346-013 SS 3/4 NPT Relay/0-20 mA X X X2200MS4M13W2 008347-013 SS M25 Relay/0-20 mA X X X2200MA4N14W1 008372-001 AL 3/4 NPT EQP X X X2200MA4M14W1 008373-001 AL M25 EQP X X X2200MS4N14W1 008374-001 SS 3/4 NPT EQP X X X2200MS4M14W1 008375-001 SS M25 EQP X X X2200MA4N14W2 008376-001 AL 3/4 NPT EQP X X X2200MA4M14W2 008377-001 AL M25 EQP X X X2200MS4N14W2 008378-001 SS 3/4 NPT EQP X X X2200MS4M14W2 008379-001 SS M25 EQP X X X2200MA4N15W1 008348-013 AL 3/4 NPT Pulse/Relay X X X2200MA4M15W1 008349-013 AL M25 Pulse/Relay X X X2200MS4N15W1 008350-013 SS 3/4 NPT Pulse/Relay X X X2200MS4M15W1 008351-013 SS M25 Pulse/Relay X X X2200MA4N15W2 008352-013 AL 3/4 NPT Pulse/Relay X X X2200MA4M15W2 008353-013 AL M25 Pulse/Relay X X X2200MS4N15W2 008354-013 SS 3/4 NPT Pulse/Relay X X X2200MS4M15W2 008355-013 SS M25 Pulse/Relay X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table D1 to choose the correct option. The EQP detectors are completely configurable using the S3 configuration software and are shipped defaulted to the -001 setting. X2200G UV Flame Detector - ATEX/IECEx/EN 54-10 The X2200G UV Flame Detector contains a Kr-85 free source tube. There are no differences in detection performance when compared to an X2200. Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d ATEX/IECEx/ EN 54-10 X2200GA4N11E1 013010-XXX AL 3/4 NPT Relay X X X2200GA4M11E1 013011-XXX AL M25 Relay X X X2200GS4N11E1 013012-XXX SS 3/4 NPT Relay X X X2200GS4M11E1 013013-XXX SS M25 Relay X X X2200GA4N11E2 013014-XXX AL 3/4 NPT Relay X X X2200GA4M11E2 013015-XXX AL M25 Relay X X X2200GS4N11E2 013016-XXX SS 3/4 NPT Relay X X X2200GS4M11E2 013017-XXX SS M25 Relay X X X2200GA4N13E1 013018-XXX AL 3/4 NPT Relay/0-20 mA X X X2200GA4M13E1 013019-XXX AL M25 Relay/0-20 mA X X X2200GS4N13E1 013020-XXX SS 3/4 NPT Relay/0-20 mA X X X2200GS4M13E1 013021-XXX SS M25 Relay/0-20 mA X X X2200GA4N13E2 013022-XXX AL 3/4 NPT Relay/0-20 mA X X X2200GA4M13E2 013023-XXX AL M25 Relay/0-20 mA X X X2200GS4N13E2 013024-XXX SS 3/4 NPT Relay/0-20 mA X X X2200GS4M13E2 013025-XXX SS M25 Relay/0-20 mA X X X2200GA4N23E1 013026-XXX AL 3/4 NPT Rly/0-20/HART X X X2200GA4M23E1 013027-XXX AL M25 Rly/0-20/HART X X X2200GS4N23E1 013028-XXX SS 3/4 NPT Rly/0-20/HART X X X2200GS4M23E1 013029-XXX SS M25 Rly/0-20/HART X X X2200GA4N23E2 013030-XXX AL 3/4 NPT Rly/0-20/HART X X X2200GA4M23E2 013031-XXX AL M25 Rly/0-20/HART X X X2200GS4N23E2 013032-XXX SS 3/4 NPT Rly/0-20/HART X X X2200GS4M23E2 013033-XXX SS M25 Rly/0-20/HART X X X2200GA4N14E1 013034-XXX AL 3/4 NPT EQP X X X2200GA4M14E1 013035-XXX AL M25 EQP X X X2200GS4N14E1 013036-XXX SS 3/4 NPT EQP X X X2200GS4M14E1 013037-XXX SS M25 EQP X X X2200GA4N14E2 013038-XXX AL 3/4 NPT EQP X X X2200GA4M14E2 013039-XXX AL M25 EQP X X X2200GS4N14E2 013040-XXX SS 3/4 NPT EQP X X X2200GS4M14E2 013041-XXX SS M25 EQP X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table D1 to choose the correct option. The EQP detectors are completely configurable using the configuration software and are shipped defaulted to the -001 setting. X2200G UV Flame Detector - CSA Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d CSA X2200GA4N13C1 013098-001 AL 3/4 NPT Relay and 0-20 mA X X X2200GA4N13C2 013102-001 AL 3/4 NPT Relay and 0-20 mA X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) X2200GM UV Flame Detector - Moly In addition to having a Kr-85 free source tube, the X2200GM UV Flame Detector utilizes a molybdenum (moly) sensing element. Moly-based sensors have an increased spectral range of 1850 to 2650 angstroms, which is better suited for detecting substances with unusual chemistry, sulfur fires, and some black powders. Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA/ ATEX/IECEx X2200GMA4N11E2 013042-003 AL 3/4 NPT Relay/0-20 mA X X2200GMA4N11E2 013042-013 AL 3/4 NPT Relay/0-20 mA X X2200GMA4M11E2 013043-003 AL M25 Relay/0-20 mA X X2200GMA4M11E2 013043-013 AL M25 Relay/0-20 mA X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table D1 to choose the correct option. The EQP detectors are completely configurable using the S3 configuration software and are shipped defaulted to the -001 setting. X2200 UV Flame Detector / xWatch Camera Model Part Number * Material Threads Output Video FM/CSA X2200A3N33A2 009564-XXX AL 3/4 NPT Relay/0-20 NTSC X X2200A3M33A2 009565-XXX AL M25 Relay/0-20 NTSC X X2200S3N33A2 009566-XXX SS 3/4 NPT Relay/0-20 NTSC X X2200S3M33A2 009567-XXX SS M25 Relay/0-20 NTSC X X2200A3N43A2 009568-XXX AL 3/4 NPT Relay/0-20 PAL X X2200A3M43A2 009569-XXX AL M25 Relay/0-20 PAL X X2200S3N43A2 009570-XXX SS 3/4 NPT Relay/0-20 PAL X X2200S3M43A2 009571-XXX SS M25 Relay/0-20 PAL X X2200A3N34A2 009572-001 AL 3/4 NPT EQP NTSC X X2200A3M34A2 009573-001 AL M25 EQP NTSC X X2200S3N34A2 009574-001 SS 3/4 NPT EQP NTSC X X2200S3M34A2 009575-001 SS M25 EQP NTSC X X2200A3N44A2 009576-001 AL 3/4 NPT EQP PAL X X2200A3M44A2 009577-001 AL M25 EQP PAL X X2200S3N44A2 009578-001 SS 3/4 NPT EQP PAL X X2200S3M44A2 009579-001 SS M25 EQP PAL X Ship Weight: Aluminum = 9lb (4.1kg) Stainless Steel = 17.6lb (7.9kg) *The last 3 digits of the part number identify the software configuration. Please see table D1 to choose the correct option. The standard EQP detectors are completely configurable using the S3 software and are defaulted to the -001 setting. NOTES: 3 year warranty excludes xWatch camera. Models listed above come with a 2.3 mm lens on the camera, which emulates the 90° field of view of the flame detector. See section Flame F for additional lens options. Which other X2200 UV Flame Detector part numbers can PE Energy supply?The 53 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description007706-013X2200M,HEAD,AL,EX D E,MOLY008426-001X2200A4N23B2 FLAME DETECTOR013000-001X2200GA4M11R2 FLAME DETECTOR013001-001X2200GS4M11R2 FLAME DETECTOR013010-001X2200GA4N11SE1 FLAME DETECTOR013012-001X2200GS4N11SE1 FLAME DETECTOR013013-001X2200GS4M11SE1 FLAME DETECTOR013014-001X2200GA4N11SE2 FLAME DETECTOR013016-001X2200GS4N11SE2 FLAME DETECTOR013019-001X2200GA4M13SE1 FLAME DETECTOR013020-001X2200GS4N13SE1 FLAME DETECTOR013021-001X2200GS4M13SE1 FLAME DETECTOR013022-001X2200GA4N13SE2 FLAME DETECTOR013024-001X2200GS4N13SE2 FLAME DETECTOR013025-001X2200GS4M13SE2 FLAME DETECTOR013026-001X2200GA4N23SE1 FLAME DETECTOR013027-001X2200GA4M23SE1 FLAME DETECTOR013028-001X2200GS4N23SE1 FLAME DETECTOR013029-001X2200GS4M23SE1 FLAME DETECTOR013030-001X2200GA4N23SE2 FLAME DETECTOR013032-001X2200GS4N23SE2 FLAME DETECTOR013033-001X2200GS4M23SE2 FLAME DETECTOR013034-001X2200GA4N14E1 FLAME DETECTOR013035-001X2200GA4M14E1 FLAME DETECTOR013036-001X2200GS4N14E1 FLAME DETECTOR013037-001X2200GS4M14E1 FLAME DETECTOR013038-001X2200GA4N14E2 FLAME DETECTOR013039-001X2200GA4M14E2 FLAME DETECTOR013040-001X2200GS4N14E2 FLAME DETECTOR013041-001X2200GS4M14E2 FLAME DETECTOR013050-006X2200GA4N15E1 FLAME DETECTOR013053-006X2200GA4N24E1 FLAME DETECTOR013054-006X2200GS4N24E1 FLAME DETECTOR013062-019X2200GA4M13T1 FLAME DETECTOR013070-001X2200G,HEAD,AL,EX D E,ATEX/SIL013071-001X2200G,HEAD,AL,EX D,ATEX/SIL013072-001X2200G,HEAD,SS,EX D E,ATEX/SIL013073-001X2200G,HEAD,SS,EX D,ATEX/SIL013080-001X2200G, HEAD, AL, EX D E013082-001X2200G, HEAD, SS, EX D E013083-001X2200G, HEAD, SS, EX D013084-001X2200GM,MOLY,HEAD, AL, EX D E013086-001X2200GM,MOLY, HEAD,SS, EX D E013087-001X2200GM,MOLY, HEAD, SS,EX D013088-001X2200GA4M11U1 FLAME DETECTOR013089-001X2200GS4M11U1 FLAME DETECTOR013090-001X2200GA4M11U2 FLAME DETECTOR013091-001X2200GS4M11U2 FLAME DETECTOR013092-001X2200GA4M13U1 FLAME DETECTOR013093-001X2200GS4M13U1 FLAME DETECTOR013094-001X2200GA4M13U2 FLAME DETECTOR013095-001X2200GS4M13U2 FLAME DETECTOR013096-001X2200GA4M15R2 FLAME DETECTOR -

Det-Tronics X3302 Multispectrum Infrared Flame Detector
X3302 Multispectrum Infrared Flame Detector (Spec Sheet: 90-1232) provides a large field of view for hydrogen fire detection coupled with superior false alarm rejection. The detector utilizes advanced signal processing algorithms supported by an embedded 32-bit microprocessor to provide continuous protection in the presence of false alarm sources and environments with infrared radiation present. When configured for Very High Sensitivity, the X3302 has a detection range of 125 feet on axis and 100 feet off axis to a hydrogen fire and is recommended for any indoor/outdoor application. The detector is available in aluminum or stainless steel. Standard outputs include fire alarm, auxiliary alarm and fault relays, with RS 485 Modbus. Optional 0-20 mA, HART, Pulse, or Eagle Quantum Premier outputs are also available. Pulse output is available for easy retrofitting into Det-Tronics R74XX controller based systems. Ideal applications include hydrogen storage, aerospace, battery rooms, and filling stations. Eagle Quantum Premier model Models available with SIL 2 certification Multiple sensitivities and certified performance to Hydrogen and Methanol Terminal block allows for Class X Pathway Designation per NFPA 72 125 feet on axis and 100 feet off axis detection range for hydrogen fire Microprocessor controlled heated optics, enable optimal performance in adverse environments Data logger for event time and date stamping Optional HART output, AMS aware, and FDT/DTM capable Automatic oi (optical integrity) continuously verifies each sensors ability to detect fire Calibrated manual testing/magnetic oi, no test lamp required Four conduit entries for easy installation Division Approval Ratings: FM and CSA Zone Approval Ratings: FM, CSA, ATEX, and IECEx Models available with integral Explosion-proof camera option (xWatch) Tricolor LED on detector faceplate indicates detector status condition X3302 Model Matrix MODEL DESCRIPTION X3302 Multispectrum IR Flame Detector TYPE MATERIAL A Aluminum (AL) S Stainless Steel (SS) TYPE THREAD TYPE 3M 3 Port, M25* 3N 3 Port, 3/4" NPT* 4M 4 Port, M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 13 Relay and 0-20 mA 14 Eagle Quantum Premier (EQP) 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23† HART, Relay, and 0-20 mA 33 Relay and 0-20 mA/ NTSC (xWatch) 34 Eagle Quantum Premier / NTSC (xWatch) 43 Relay and 0-20 mA / PAL (xWatch) 44 Eagle Quantum Premier / PAL (xWatch) TYPE APPROVALS‡ A FM/CSA B INMETRO (BRAZIL) R VNIIPO/VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION 1 Division/Zone Ex d e 2 Division/Zone Ex d *3-port models only available with output types 33, 34, 43, and 44 (xWatch) † Type 23 Output - When HART output chosen detector does not have RS-485 communication available. ‡Type Approvals can use one or more letters to designate the approvals of the product. Table A2 - X3302 Software Part Number Configuration Matrix Dash Sensitivity Alarm Relay Aux Relay Fault Relay Special -001 Medium De-energized Non-latching Energized Non-latching Energized Non-latching None -002 Very High De-energized Non-latching Energized Non-latching Energized Non-latching None -004 Low De-energized Non-latching Energized Non-latching Energized Non-latching 3 min oi 10 fails to fault -006 Medium De-energized Non-latching De-energized Non-latching Energized Non-latching None -007 Very High De-energized Non-latching De-energized Non-latching Energized Non-latching None -009 Low De-energized Non-Latching De-energized Non-Latching Energized Non-latching 3 min oi 10 fails to fault -050 High De-energized Non-Latching Energized Non-latching Energized Non-latching None -051 High De-energized Non-Latching Energized Non-latching Energized Non-latching None NOTE: The X3302 window heaters are set to 100% as a default but can be configured from 0-100% with the Enhanced Flame Inspector. Please refer to section E.3 for more details. Application Guidelines The following criteria should be considered when choosing a sensitivity level for the intended application: Speed of response based on fuel type and fire size Distance between the hazard and the flame detector These are typical industry application settings. They may not be applicable to all installations. Contact factory for additional application guidance. NOTE: Latching relays cannot be used in voted systems. Fertilizer (Outdoor), Ammonia, Refrigerants 001 Aerospace, Hydrogen Storage 002 Filling Stations, Turbines 004 Fertilizer (Indoor), Refrigerants, Compressors, Battery Manufacturing 050 X3302 Multispectrum Infrared Flame Detector - SIL 2 Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA/ ATEX/IECEx SIL 2 X3302A4N13T1 029008-XXX AL 3/4 NPT Relay/0-20mA X X X X3302A4M13T1 029009-XXX AL M25 Relay/0-20mA X X X X3302S4N13T1 029010-XXX SS 3/4 NPT Relay/0-20mA X X X X3302S4M13T1 029011-XXX SS M25 Relay/0-20mA X X X X3302A4N13T2 029012-XXX AL 3/4 NPT Relay/0-20mA X X X X3302A4M13T2 029013-XXX AL M25 Relay/0-20mA X X X X3302S4N13T2 029014-XXX SS 3/4 NPT Relay/0-20mA X X X X3302S4M13T2 029015-XXX SS M25 Relay/0-20mA X X X X3302A4N23T1 029032-XXX AL 3/4 NPT Relay/0-20mA/HART X X X X3302A4M23T1 029033-XXX AL M25 Relay/0-20mA/HART X X X X3302S4N23T1 029034-XXX SS 3/4 NPT Relay/0-20mA/HART X X X X3302S4M23T1 029035-XXX SS M25 Relay/0-20mA/HART X X X X3302A4N23T2 029036-XXX AL 3/4 NPT Relay/0-20mA/HART X X X X3302A4M23T2 029037-XXX AL M25 Relay/0-20mA/HART X X X X3302S4N23T2 029038-XXX SS 3/4 NPT Relay/0-20mA/HART X X X X3302S4M23T2 029039-XXX SS M25 Relay/0-20mA/HART X X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 13.8lb (6.3kg) X3302 Multispectrum Infrared Flame Detector Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA ATEX/IECEx X3302A4N13W1 029000-XXX AL 3/4 NPT Relay/0-20mA X X X3302A4M13W1 029001-XXX AL M25 Relay/0-20mA X X X3302S4N13W1 029002-XXX SS 3/4 NPT Relay/0-20mA X X X3302S4M13W1 029003-XXX SS M25 Relay/0-20mA X X X3302A4N13W2 029004-XXX AL 3/4 NPT Relay/0-20mA X X X3302A4M13W2 029005-XXX AL M25 Relay/0-20mA X X X3302S4N13W2 029006-XXX SS 3/4 NPT Relay/0-20mA X X X3302S4M13W2 029007-XXX SS M25 Relay/0-20mA X X X3302A4N15W1 029016-XXX AL 3/4 NPT Pulse/Relay X X X3302A4M15W1 029017-XXX AL M25 Pulse/Relay X X X3302S4N15W1 029018-XXX SS 3/4 NPT Pulse/Relay X X X3302S4M15W1 029019-XXX SS M25 Pulse/Relay X X X3302A4N15W2 029020-XXX AL 3/4 NPT Pulse/Relay X X X3302A4M15W2 029021-XXX AL M25 Pulse/Relay X X X3302S4N15W2 029022-XXX SS 3/4 NPT Pulse/Relay X X X3302S4M15W2 029023-XXX SS M25 Pulse/Relay X X X3302A4N14W1 029024-001 AL 3/4 NPT EQP X X X3302A4M14W1 029025-001 AL M25 EQP X X X3302S4N14W1 029026-001 SS 3/4 NPT EQP X X X3302S4M14W1 029027-001 SS M25 EQP X X X3302A4N14W2 029028-001 AL 3/4 NPT EQP X X X3302A4M14W2 029029-001 AL M25 EQP X X X3302S4N14W2 029030-001 SS 3/4 NPT EQP X X X3302S4M14W2 029031-001 SS M25 EQP X X X3302A4N23W1 029090-XXX AL 3/4 NPT Relay/0-20mA/HART X X X3302A4M23W1 029091-XXX AL M25 Relay/0-20mA/HART X X X3302S4N23W1 029092-XXX SS 3/4 NPT Relay/0-20mA/HART X X X3302S4M23W1 029093-XXX SS M25 Relay/0-20mA/HART X X X3302A4N23W2 029094-XXX AL 3/4 NPT Relay/0-20mA/HART X X X3302A4M23W2 029095-XXX AL M25 Relay/0-20mA/HART X X X3302S4N23W2 029096-XXX SS 3/4 NPT Relay/0-20mA/HART X X X3302S4M23W2 029097-XXX SS M25 Relay/0-20mA/HART X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 13.8lb (6.3kg) *The last 3 digits of the part number identify the software configuration. Please see table A2 to choose the correct option. The standard EQP detectors are completely configurable using the S3 software and are shipped defaulted to the -001 setting Which other X3302 Multispectrum Infrared Flame Detector part numbers can PE Energy supply?The 2 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description029085-001X3302A4N23SB2 FLAME DETECTOR029088-001X3302S4N23SB2 FLAME DETECTOR -

Det-Tronics X5200 UVIR Flame Detector
X5200 UVIR Flame Detector (Spec Sheet: 90-1156) meets the most stringent requirements worldwide with advanced ultra high speed detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The combination of Arc Rejection on the UV sensor and TDSA/Quick Fire on the IR sensor make this detector the highest false alarm immune UVIR available. The mounting arrangement allows the UV and IR sensors to monitor the same hazardous location with a 90-degree field of view. When both sensors simultaneously detect the presence of a flame, an alarm signal is generated. The standard output configuration includes fire, fault, and auxiliary relays with RS-485 Modbus. Optional 0-20 mA, Eagle Quantum Premier, or HART outputs are also available. Auxiliary relay offers the flexibility to customize detection, using UV, IR, or both. A model with pulse output is available for easy retrofitting into existing Det-Tronics controller based systems. The X5200 housing is available in aluminum or stainless steel, with NEMA/Type 4X and IP66/IP67 rating. Typical applications include paper machines, munitions, petrochemical applications, and aerosol filling. Eagle Quantum Premier and Eagle Quantum compatible models available Models available with SIL 2 certification Responds to a fire in the presence of modulated blackbody radiation (i.e., heaters, ovens, turbines) without false alarm Ultra high speed capability Optional HART output, AMS aware, and FDT/DTM capable Heated optics for increased resistance to moisture and ice Automatic, manual, or magnetic oi (optical integrity) FM, CSA, ATEX, and IECEx EN 54 part 10 certified by BRE, LPCB Meets Construction Product Directive Configurable auxiliary relay allows independent alarm signaling Terminal block allows for Class X Pathway Designation per NFPA 72 EMI, RFI, EMC Directive Compliant Built-in data logging / event monitoring Models available with integral Explosion-proof camera option (xWatch) Tricolor LED on detector faceplate indicates detector status condition X5200 Model Matrix MODEL DESCRIPTION X5200 UVIR Flame Detector X5200G UVIR Flame Detector with Kr85 free Source Tube X5200M* UVIR Flame Detector with Molybdenum Tube TYPE MATERIAL A Aluminum (AL) S Stainless Steel (SS) TYPE THREAD TYPE 3M 3 Port, M25† 3N 3 Port, 3/4" NPT† 4M 4 Port, M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 11 Relay 13 Relay and 0-20 mA 14 Eagle Quantum Premier 24 Eagle Quantum 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23‡ HART, Relay, and 0-20 mA 33 Relay and 0-20 mA / NTSC (xWatch) 34 Eagle Quantum Premier / NTSC (xWatch) 43 Relay and 0-20 mA / PAL (xWatch) 44 Eagle Quantum Premier / PAL (xWatch) TYPE APPROVALS§ A FM/CSA B INMETRO (BRAZIL) E ATEX/IECEx/EN 54-10 R VNIIPO/VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx U TCCExEE/UKRCEPRO (UKRAINE) W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION 1 Division/Zone Ex d e 2 Division/Zone Ex d *Special Application - consult factory before ordering. †3-port models only available with output types 33, 34, 43, and 44 (xWatch) ‡Type 23 Output - When HART output chosen detector does not have RS-485 communication available. §Type Approvals can use one or more letters to designate the approvals of the product Table B1 - X5200 Software Part Number Configuration Matrix Dash UV Sensitivity Arc Rejection IR Sensitivity Alarm Output IR Qualifications Alarm Relay Aux Output Function ARC Rejection Aux Output IR Qualifications Aux Relay Alarm Relay -001 High High High TDSA Only De-Energized Non-latching Follows Alarm High TDSA Energized Non-latching Energized Non-latching -002 High Very High High TDSA or Quick De-Energized Non-latching Follows Alarm Very High TDSA or Quick Energized Non-latching Energized Non-latching -003 High Off Very High TDSA or Quick De-Energized Non-latching UV or IR Off TDSA Energized Non-latching Energized Non-latching -004 High High Very High TDSA Only De-Energized Non-latching Pre-Alarm High TDSA Energized Non-latching Energized Non-latching -005 Medium High High TDSA or Quick De-Energized Non-latching UV or IR High TDSA Energized Non-latching Energized Non-latching -006 High High Low TDSA Only De-Energized Non-latching Pre-Alarm High TDSA Energized Non-latching Energized Non-latching -007 High High High TDSA Only De-Energized Latching Follows Alarm High TDSA De-energized Latching Energized Non-latching -008 High Very High High TDSA or Quick De-Energized Latching Follows Alarm Very High TDSA or Quick De-energized Latching Energized Non-latching -009 High Off Very High TDSA or Quick De-Energized Latching UV or IR Off TDSA De-energized Latching Energized Non-latching -010 High High Very High TDSA Only De-Energized Latching Pre-Alarm High TDSA De-energized Latching Energized Non-latching -011 Medium High High TDSA or Quick De-Energized Latching UV or IR High TDSA De-energized Latching Energized Non-latching -012 High High Low TDSA Only De-Energized Latching Pre-Alarm High TDSA De-energized Latching Energized Non-latching -013* High Off High TDSA or Quick De-Energized Non-Latching Follows Alarm Off TDSA or Quick Energized Non-Latching Energized Non-latching -014* High Off High TDSA or Quick De-Energized Latching Follows Alarm Off TDSA or Quick De-energized Latching Energized Non-latching -015 Very High Low Very High TDSA or Quick De-Energized Non-Latching Follows Alarm Off TDSA or Quick Energized Non-Latching Energized Non-latching -016 Very High Low Very High TDSA or Quick De-Energized Latching Follows Alarm Off TDSA or Quick De-energized Latching Energized Non-latching -019 Very High Off Very High TDSA or Quick De-Energized Non-Latching UV or IR Off TDSA Energized Non-Latching Energized Non-latching -021 Very High Off Very High TDSA or Quick De-Energized Latching Follows Alarm Off TDSA or Quick Energized Latching Energized Non-latching -022 Very High Off Very High TDSA or Quick De-Energized Non-Latching UV or IR Off TDSA or Quick De-Energized Non-latching Energized Non-latching *Available only on the X5200M model ARC = Arc Rejection. An algorithm that prevents false alarms from transient UV sources TDSA = "Time Domain Signal Analysis" proprietary signal processing algorithm for superior IR false alarm rejection Quick = Signal processing for explosive IR events Application Guidelines The following criteria should be considered when choosing a sensitivity level for the intended application: Speed of response based on fuel type and fire size Distance between the hazard and the flame detector These are typical industry application settings. They may not be applicable to all installations. Contact factory for additional application guidance. Offshore 001 Compressor 002 Paper Machine 003 Engine Test Cells 001 Aerosol Fill 013/022 Munitions 013/022 High Speed 013/022 NOTE: Latching relays cannot be used in voted systems. X5200 UVIR Flame Detector - SIL 2 Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone SIL/FM/CSA/ ATEX/IECEx X5200A4N13T1 008650-XXX AL 3/4 NPT Relay/0-20 mA X X X5200A4M13T1 008651-XXX AL M25 Relay/0-20 mA X X X5200S4N13T1 008652-XXX SS 3/4 NPT Relay/0-20 mA X X X5200S4M13T1 008653-XXX SS M25 Relay/0-20 mA X X X5200A4N13T2 008654-XXX AL 3/4 NPT Relay/0-20 mA X X X5200A4M13T2 008655-XXX AL M25 Relay/0-20 mA X X X5200S4N13T2 008656-XXX SS 3/4 NPT Relay/0-20 mA X X X5200S4M13T2 008657-XXX SS M25 Relay/0-20 mA X X X5200A4N23T1 008658-XXX AL 3/4 NPT Rly/0-20/HART X X X5200A4M23T1 008659-XXX AL M25 Rly/0-20/HART X X X5200S4N23T1 008660-XXX SS 3/4 NPT Rly/0-20/HART X X X5200S4M23T1 008661-XXX SS M25 Rly/0-20/HART X X X5200A4N23T2 008662-XXX AL 3/4 NPT Rly/0-20/HART X X X5200A4M23T2 008663-XXX AL M25 Rly/0-20/HART X X X5200S4N23T2 008664-XXX SS 3/4 NPT Rly/0-20/HART X X X5200S4M23T2 008665-XXX SS M25 Rly/0-20/HART X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) X5200 UVIR Flame Detector - Moly - SIL 2 Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d SIL/FM/CSA/ ATEX/IECEx X5200MA4N23T1 008666-XXX AL 3/4 NPT Rly/0-20/HART X X X5200MA4M23T1 008667-XXX AL M25 Rly/0-20/HART X X X5200MS4N23T1 008668-XXX SS 3/4 NPT Rly/0-20/HART X X X5200MS4M23T1 008669-XXX SS M25 Rly/0-20/HART X X X5200MA4N23T2 008670-XXX AL 3/4 NPT Rly/0-20/HART X X X5200MA4M23T2 008671-XXX AL M25 Rly/0-20/HART X X X5200MS4N23T2 008672-XXX SS 3/4 NPT Rly/0-20/HART X X X5200MS4M23T2 008673-XXX SS M25 Rly/0-20/HART X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table B1 to choose the correct option. X5200 UVIR Flame Detector Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA/ ATEX/IECEx X5200A4N11W1 008500-XXX AL 3/4 NPT Relay X X X5200A4M11W1 008501-XXX AL M25 Relay X X X5200S4N11W1 008502-XXX SS 3/4 NPT Relay X X X5200S4M11W1 008503-XXX SS M25 Relay X X X5200A4N11W2 008504-XXX AL 3/4 NPT Relay X X X5200A4M11W2 008505-XXX AL M25 Relay X X X5200S4N11W2 008506-XXX SS 3/4 NPT Relay X X X5200S4M11W2 008507-XXX SS M25 Relay X X X5200A4N14W1 008516-001 AL 3/4 NPT EQP X X X5200A4M14W1 008517-001 AL M25 EQP X X X5200S4N14W1 008518-001 SS 3/4 NPT EQP X X X5200S4M14W1 008519-001 SS M25 EQP X X X5200A4N14W2 008520-001 AL 3/4 NPT EQP X X X5200A4M14W2 008521-001 AL M25 EQP X X X5200S4N14W2 008522-001 SS 3/4 NPT EQP X X X5200S4M14W2 008523-001 SS M25 EQP X X X5200A4N15W1 008524-XXX AL 3/4 NPT Pulse/Relay X X X5200A4M15W1 008525-XXX AL M25 Pulse/Relay X X X5200S4N15W1 008526-XXX SS 3/4 NPT Pulse/Relay X X X5200S4M15W1 008527-XXX SS M25 Pulse/Relay X X X5200A4N15W2 008528-XXX AL 3/4 NPT Pulse/Relay X X X5200A4M15W2 008529-XXX AL M25 Pulse/Relay X X X5200S4N15W2 008530-XXX SS 3/4 NPT Pulse/Relay X X X5200S4M15W2 008531-XXX SS M25 Pulse/Relay X X X5200A4N24W1 008556-XXX AL 3/4 NPT Eagle Quantum X X X5200A4M24W1 008557-001 AL M25 Eagle Quantum X X X5200S4N24W1 008558-001 SS 3/4 NPT Eagle Quantum X X X5200S4M24W1 008559-001 SS M25 Eagle Quantum X X X5200A4N24W2 008560-001 AL 3/4 NPT Eagle Quantum X X X5200A4M24W2 008561-001 AL M25 Eagle Quantum X X X5200S4N24W2 008562-001 SS 3/4 NPT Eagle Quantum X X X5200S4M24W2 008563-001 SS M25 Eagle Quantum X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) X5200G UVIR Flame Detector - ATEX/IECEx/EN 54-10 The X5200G UVIR Flame Detector contains a Kr-85 free source tube. There are no differences in detection performance when compared to an X5200. Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA/ ATEX/IECEx X5200GA4N11E1 013244-XXX AL 3/4 NPT Relay X X X5200GA4M11E1 013245-XXX AL M25 Relay X X X5200GS4N11E1 013246-XXX SS 3/4 NPT Relay X X X5200GS4M11E1 013247-XXX SS M25 Relay X X X5200GA4N11E2 013248-XXX AL 3/4 NPT Relay X X X5200GA4M11E2 013249-XXX AL M25 Relay X X X5200GS4N11E2 013250-XXX SS 3/4 NPT Relay X X X5200GS4M11E2 013251-XXX SS M25 Relay X X X5200GA4N13E1 013252-XXX AL 3/4 NPT Relay/0-20 mA X X X5200GA4M13E1 013253-XXX AL M25 Relay/0-20 mA X X X5200GS4N13E1 013254-XXX SS 3/4 NPT Relay/0-20 mA X X X5200GS4M13E1 013255-XXX SS M25 Relay/0-20 mA X X X5200GA4N13E2 013256-XXX AL 3/4 NPT Relay/0-20 mA X X X5200GA4M13E2 013257-XXX AL M25 Relay/0-20 mA X X X5200GS4N13E2 013258-XXX SS 3/4 NPT Relay/0-20 mA X X X5200GS4M13E2 013259-XXX SS M25 Relay/0-20 mA X X X5200GA4N23E1 013260-XXX AL 3/4 NPT Rly/0-20/HART X X X5200GA4M23E1 013261-XXX AL M25 Rly/0-20/HART X X X5200GS4N23E1 013262-XXX SS 3/4 NPT Rly/0-20/HART X X X5200GS4M23E1 013263-XXX SS M25 Rly/0-20/HART X X X5200GA4N23E2 013264-XXX AL 3/4 NPT Rly/0-20/HART X X X5200GA4M23E2 013265-XXX AL M25 Rly/0-20/HART X X X5200GS4N23E2 013266-XXX SS 3/4 NPT Rly/0-20/HART X X X5200GS4M23E2 013267-XXX SS M25 Rly/0-20/HART X X X5200GA4N14E1 013268-001 AL 3/4 NPT EQP X X X5200GA4M14E1 013269-001 AL M25 EQP X X X5200GS4N14E1 013270-001 SS 3/4 NPT EQP X X X5200GS4M14E1 013271-001 SS M25 EQP X X X5200GA4N14E2 013272-001 AL 3/4 NPT EQP X X X5200GA4M14E2 013273-001 AL M25 EQP X X X5200GS4N14E2 013274-001 SS 3/4 NPT EQP X X X5200GS4M14E2 013275-001 SS M25 EQP X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table B1 to choose the correct option. The EQ and EQP detectors are completely configurable using the S3 configuration software and are shipped defaulted to the -001 setting. X5200G UVIR Flame Detector - CSA Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d CSA X5200GA4N13C1 013308-XXX AL 3/4 NPT Relay/0-20 mA X X X5200GA4N13C2 013312-XXX AL 3/4 NPT Relay/0-20 mA X X *The last 3 digits of the part number identify the software configuration. Please see table B1 to choose the correct option. The EQ and EQP detectors are completely configurable using the S3 configuration software and are shipped defaulted to the -001 setting. X5200M UVIR Flame Detector - Moly The X5200M UV/IR detector utilizes a molybdenum (moly) sensing element. Moly-based sensors have an increased spectral range of 1850 to 2650 angstroms, which is better suited for detecting substances with unusual chemistry and some black powders. Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d CSA X5200MA4N13W1 008540-013 AL 3/4 NPT Relay/0-20 mA X X X5200MA4M13W1 008541-013 AL M25 Relay/0-20 mA X X X5200MS4N13W1 008542-013 SS 3/4 NPT Relay/0-20 mA X X X5200MS4M13W1 008543-013 SS M25 Relay/0-20 mA X X X5200MA4N13W2 008544-013 AL 3/4 NPT Relay/0-20 mA X X X5200MA4M13W2 008545-013 AL M25 Relay/0-20 mA X X X5200MS4N13W2 008546-013 SS 3/4 NPT Relay/0-20 mA X X X5200MS4M13W2 008547-013 SS M25 Relay/0-20 mA X X X5200MA4N15W1 008548-013 AL 3/4 NPT Pulse/Relay X X X5200MA4M15W1 008549-013 AL M25 Pulse/Relay X X X5200MS4N15W1 008550-013 SS 3/4 NPT Pulse/Relay X X X5200MS4M15W1 008551-013 SS M25 Pulse/Relay X X X5200MA4N15W2 008552-013 AL 3/4 NPT Pulse/Relay X X X5200MA4M15W2 008553-013 AL M25 Pulse/Relay X X X5200MS4N15W2 008554-013 SS 3/4 NPT Pulse/Relay X X X5200MS4M15W2 008555-013 SS M25 Pulse/Relay X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table B1 to choose the correct option. X5200 UVIR Flame Detector / xWatch Camera Model Part Number * Material Threads Output Video FM/CSA X5200A3N33A2 009532-XXX AL 3/4 NPT Relay/0-20 NTSC X X5200A3M33A2 009533-XXX AL M25 Relay/0-20 NTSC X X5200S3N33A2 009534-XXX SS 3/4 NPT Relay/0-20 NTSC X X5200S3M33A2 009535-XXX SS M25 Relay/0-20 NTSC X X5200A3N43A2 009536-XXX AL 3/4 NPT Relay/0-20 PAL X X5200A3M43A2 009537-XXX AL M25 Relay/0-20 PAL X X5200S3N43A2 009538-XXX SS 3/4 NPT Relay/0-20 PAL X X5200S3M43A2 009539-XXX SS M25 Relay/0-20 PAL X X5200A3N34A2 009540-001 AL 3/4 NPT EQP NTSC X X5200A3M34A2 009541-001 AL M25 EQP NTSC X X5200S3N34A2 009542-001 SS 3/4 NPT EQP NTSC X X5200S3M34A2 009543-001 SS M25 EQP NTSC X X5200A3N44A2 009544-001 AL 3/4 NPT EQP PAL X X5200A3M44A2 009545-001 AL M25 EQP PAL X X5200S3N44A2 009546-001 SS 3/4 NPT EQP PAL X X5200S3M44A2 009547-001 SS M25 EQP PAL X Ship Weight: Aluminum = 9lb (4.1kg) Stainless Steel = 17.6lb (7.9kg) *The last 3 digits of the part number identify the software configuration. Please see table B1 to choose the correct option. The standard EQP detectors are completely configurable using the S3 software and are defaulted to the -001 setting. NOTES: 3 year warranty excludes xWatch camera. Models listed above come with a 2.3 mm lens on the camera, which emulates the 90° field of view of the flame detector. See section Flame F for additional lens options. Which other X5200 UVIR Flame Detector part numbers can PE Energy supply?The 53 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description008506-001X5200S4N11W2 FLAME DETECTOR013200-001X5200GA4M11R1 FLAME DETECTOR013202-001X5200GS4M11R2 FLAME DETECTOR013203-001X5200GA4M13R1 FLAME DETECTOR013204-001X5200GS4M13R1 FLAME DETECTOR013205-001X5200GA4M13R2 FLAME DETECTOR013206-001X5200GS4M11R1 FLAME DETECTOR013207-001X5200GS4M13R2 FLAME DETECTOR013208-001X5200GA4M14R1 FLAME DETECTOR013209-001X5200GS4M14R1 FLAME DETECTOR013210-001X5200GA4M14R2 FLAME DETECTOR013211-001X5200GS4M14R2 FLAME DETECTOR013220-001X5200GA4N15K2 FLAME DETECTOR013221-001X5200GS4M23R2 FLAME DETECTOR013246-001X5200GS4N11SE1 FLAME DETECTOR013248-001X5200GA4N11SE2 FLAME DETECTOR013253-001X5200GA4M13SE1 FLAME DETECTOR013254-001X5200GS4N13SE1 FLAME DETECTOR013255-001X5200GS4M13SE1 FLAME DETECTOR013256-001X5200GA4N13SE2 FLAME DETECTOR013258-001X5200GS4N13SE2 FLAME DETECTOR013259-001X5200GS4M13SE2 FLAME DETECTOR013260-001X5200GA4N23SE1 FLAME DETECTOR013262-001X5200GS4N23SE1 FLAME DETECTOR013263-001X5200GS4M23SE1 FLAME DETECTOR013264-001X5200GA4N23SE2 FLAME DETECTOR013265-001X5200GA4M23SE2 FLAME DETECTOR013266-001X5200GS4N23SE2 FLAME DETECTOR013276-001X5200GA4M15E1 FLAME DETECTOR013277-001X5200GA4N15E1 FLAME DETECTOR013277-006X5200GA4N15SE1 FLAME DETECTOR013280-006X5200GA4N24E1 FLAME DETECTOR013281-006X5200GS4N24E1 FLAME DETECTOR013288-001X5200G, HEAD, AL, EX D E013290-001X5200G, HEAD, SS, EX D E013292-001X5200GA4M11U1 FLAME DETECTOR013293-001X5200GS4M11U1 FLAME DETECTOR013295-001X5200GS4M11U2 FLAME DETECTOR013296-001X5200GA4M13U1 FLAME DETECTOR013297-001X5200GS4M13U1 FLAME DETECTOR013298-001X5200GA4M13U2 FLAME DETECTOR013299-001X5200GS4M13U2 FLAME DETECTOR013308-001X5200GA4N13C1 FLAME DETECTOR013312-001X5200GA4N13C2 FLAME DETECTOR013320-022X5200GA4N13T1 FLAME DETECTOR013322-022X5200GA4M13T1 FLAME DETECTOR013323-022X5200GA4M13T2 FLAME DETECTOR013370-001X5200G,HEAD,AL,EX D E,ATEX/SIL013371-001X5200G,HEAD,AL,EX D,ATEX/SIL013372-001X5200G,HEAD,SS,EX D E,ATEX/SIL013373-001X5200G,HEAD,SS,EX D,ATEX/SIL013374-022X5200G,HEAD,AL,EXD,FM/ATEX/SIL013375-022X5200G,HD,AL,EXDE,FM/ATEX/SIL -

Det-Tronics X7050 xWatch Explosion-Proof Surveillance Camera
X7050 xWatch Explosion-Proof Surveillance Camera (Spec Sheet 90-1193) An explosion proof surveillance camera providing high-resolution color images of activity in the monitored area, which allows the capture and recording of fires and other activities on video. When a detector goes into alarm, the operator can immediately view the monitored area in real time and accurately assess the risk and location of the fire. The camera can be used with any video switcher or server for a live video feed and the output can be directed to a DVR or computer monitor. xWatch camera features: Easy connection to a video switcher using twisted pair wiring Existing wiring can be used in most applications FM, CSA, ATEX, and IECEx Three lens choices for field of view requirements Retrofit into a standard C7050 housing by simply replacing the tube module with the DE2020 camera module Three configurations are available: As a stand-alone device to perform typical CCTV functions Retrofitted into a C7050 Detector, replacing the UV tube module with the camera module Ordered as a combined unit with any of the X-Series Flame Detectors (see flame detector sections for specific models) - FM/CSA. X7050 Model Matrix MODEL DESCRIPTION X7050 xWatch Explosion-Proof Camera TYPE MATERIAL A Aluminum (AL) S Stainless Steel (SS) TYPE THREAD TYPE 1E 1/2" NPT 1F M20 TYPE VIDEO OUTPUT 50 NTSC 51 PAL TYPE FIELD OF VIEW 1 Wide FOV (90°), 2.3mm Lens* 2 Normal FOV (50°), 4.3mm Lens 3 Narrow FOV (30°), 8.0mm Lens TYPE APPROVALS W FM/CSA/ATEX/IECEx TYPE CLASSIFICATION 1 Division/Zone Ex d *This lens emulates the 90° field of view to match the X-Series Flame Detectors. X7050 xWatch Camera Model Part Number Material Threads FOV Output Ship Weight X7050A1E501W2 009580-001 AL 1/2 NPT 2.3mm NTSC 1.5 lb (0.7 kg) X7050A1E502W2 009580-002 AL 1/2 NPT 4.3mm NTSC 1.5 lb (0.7 kg) X7050A1E503W2 009580-003 AL 1/2 NPT 8.0mm NTSC 1.5 lb (0.7 kg) X7050A1F501W2 009581-001 AL M20 2.3mm NTSC 1.5 lb (0.7 kg) X7050A1F502W2 009581-002 AL M20 4.3mm NTSC 1.5 lb (0.7 kg) X7050A1F503W2 009581-003 AL M20 8.0mm NTSC 1.5 lb (0.7 kg) X7050S1E501W2 009582-001 SS 1/2 NPT 2.3mm NTSC 2.5 lb (1.2 kg) X7050S1E502W2 009582-002 SS 1/2 NPT 4.3mm NTSC 2.5 lb (1.2 kg) X7050S1E503W2 009582-003 SS 1/2 NPT 8.0mm NTSC 2.5 lb (1.2 kg) X7050S1F501W2 009583-001 SS M20 2.3mm NTSC 2.5 lb (1.2 kg) X7050S1F502W2 009583-002 SS M20 4.3mm NTSC 2.5 lb (1.2 kg) X7050S1F503W2 009583-003 SS M20 8.0mm NTSC 2.5 lb (1.2 kg) X7050A1E511W2 009584-001 AL 1/2 NPT 2.3mm PAL 1.5 lb (0.7 kg) X7050A1E512W2 009584-002 AL 1/2 NPT 4.3mm PAL 1.5 lb (0.7 kg) X7050A1E513W2 009584-003 AL 1/2 NPT 8.0mm PAL 1.5 lb (0.7 kg) X7050A1F511W2 009585-001 AL M20 2.3mm PAL 1.5 lb (0.7 kg) X7050A1F512W2 009585-002 AL M20 4.3mm PAL 1.5 lb (0.7 kg) X7050A1F513W2 009585-003 AL M20 8.0mm PAL 1.5 lb (0.7 kg) X7050S1E511W2 009586-001 SS 1/2 NPT 2.3mm PAL 2.5 lb (1.2 kg) X7050S1E512W2 009586-002 SS 1/2 NPT 4.3mm PAL 2.5 lb (1.2 kg) X7050S1E513W2 009586-003 SS 1/2 NPT 8.0mm PAL 2.5 lb (1.2 kg) X7050S1F511W2 009587-001 SS M20 2.3mm PAL 2.5 lb (1.2 kg) X7050S1F512W2 009587-002 SS M20 4.3mm PAL 2.5 lb (1.2 kg) X7050S1F513W2 009587-003 SS M20 8.0mm PAL 2.5 lb (1.2 kg) X7050 Spare Camera Modules Model Part Number FOV Output Ship Weight DE2020N 009448-003 2.3mm NTSC 5 oz. (0.14 kg) DE2020P 009448-004 2.3mm PAL 5 oz. (0.14 kg) DE2022N 009448-005 4.3mm NTSC 5 oz. (0.14 kg) DE2022P 009448-006 4.3mm PAL 5 oz. (0.14 kg) DE2023N 009448-007 8.0mm NTSC 5 oz. (0.14 kg) DE2023P 009448-008 8.0mm PAL 5 oz. (0.14 kg) X7050 Mounting Hardware Model Part Number Material Ship Weight Q9001B1175 002099-003 AL 0.5 lb (0.23 kg) Q9001H8001 004404-002 SS 1 lb (0.45 kg) X7050 Accessories Part Number Description Ship Weight 000499-132 Screw Terminal Balun, Active, converts single composite CCTV video signal from CAT-5 twisted pair wiring to BNC coaxial connector on DVR or video multiplexer, active type, suitable for distances over 750 ft (0.23 km) <1 lb (<0.45 kg) 000499-073 Screw Terminal Balun, Passive, converts single composite CCTV video signal from CAT-5 twisted pair wiring to BNC coaxial connector on DVR or video multiplexer, passive type, suitable for distances up to 750 ft (0.23 km) <1 lb (<0.45 kg) -

Det-Tronics X9800 Single Frequency IR Flame Detector
The X9800 IR Flame Detector (Spec Sheet: 90-1160) meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector is equipped with dual signal processing (Quick Fire high speed operation and Time Domain Signal Analysis) and automatic/magnetic manual oi (optical integrity) test capability. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications. The standard output configuration includes fire, fault, and auxiliary relays with RS-485 Modbus. Optional 0-20 mA, Pulse, Eagle Quantum Premier, or HART outputs are also available. A model with pulse output is available for easy retrofitting into existing Det-Tronics R74XX controller-based systems. The X9800 housing is available in aluminum or stainless steel, with NEMA/Type 4X and IP66/IP67 rating. Typical applications include: printing, petrochemical, automotive, and dirty environments. Models available with SIL 2 certification Unequaled false alarm rejection, TDSA Tricolor LED on detector faceplate indicates detector status condition Ultra High speed capability Heated optics for increased resistance to moisture and ice Automatic, manual, or magnetic oi testing Optional HART output and AMS aware Tricolor LED indicates normal operation, fire, and fault conditions FM, CSA, ATEX, and IECEx EN 54 part 10 certified by BRE, LPCB Mounting arm allows easy sighting Integral wiring compartment for ease of installation Terminal block allows for Class X Pathway Designation per NFPA 72 Meets NFPA 33 response requirement for under 0.5 seconds (available when model selected) Built-in data logging / event monitoring Models available with integral Explosion-proof camera option (xWatch) X9800 Model Matrix MODEL DESCRIPTION X9800 Single Frequency IR Flame Detector TYPE MATERIAL A Aluminum (AL) S Stainless Steel (SS) TYPE THREAD TYPE 3M 3 Port, M25* 3N 3 Port, 3/4" NPT* 4M 4 Port, M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 11 Relay 13 Relay and 0-20 mA 14 Eagle Quantum Premier 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23† HART, Relay, and 0-20 mA 33 Relay and 0-20 mA / NTSC (xWatch) 34 Eagle Quantum Premier / NTSC (xWatch) 43 Relay and 0-20 mA / PAL (xWatch) 44 Eagle Quantum Premier / PAL (xWatch) TYPE APPROVALS‡ A FM/CSA R VNIIPO/VNIIFTRI (RUSSIA) S SIL T SIL/FM/CSA/ATEX/IECEx U TCCEX EE/UKRCEPRO (UKRAINE) W FM/CSA/ATEX/IECEx/ Y CHINA TYPE CLASSIFICATION 1 Division/Zone Ex d e 2 Division/Zone Ex d *3-port models only available with output types 33, 34, 43, and 44 (xWatch) † Type 23 Output - When HART output chosen detector does not have RS-485 communication available. ‡Type Approvals can use one or more letters to designate the approvals of the product. Table C1 - X9800 Software Part Number Configuration Matrix Dash IR Sensitivity Alarm Output IR Qualifications Alarm Relay Aux Output Function Aux Output IR Qualifications Aux Relay Alarm Relay -001 High TDSA De-Energized Non-latching Follows Alarm TDSA Energized Non-latching Energized Non-latching -002 High TDSA or Quick De-Energized Non-latching Follows Alarm TDSA or Quick Energized Non-latching Energized Non-latching -003 Very High TDSA or Quick De-Energized Non-latching Follows Alarm TDSA or Quick Energized Non-latching Energized Non-latching -004 Very High TDSA De-Energized Non-latching Follows Alarm TDSA Energized Non-latching Energized Non-latching -005 High TDSA or Quick De-Energized Non-latching Independent Quick Energized Non-latching Energized Non-latching -006 Low TDSA De-Energized Non-latching Follows Alarm TDSA Energized Non-latching Energized Non-latching -007 High TDSA De-Energized Latching Follows Alarm TDSA De-energized Latching Energized Non-latching -008 High TDSA or Quick De-Energized Latching Follows Alarm TDSA or Quick De-energized Latching Energized Non-latching -009 Very High TDSA or Quick De-Energized Latching Follows Alarm TDSA or Quick De-energized Latching Energized Non-latching -010 Very High TDSA De-Energized Latching Follows Alarm TDSA De-energized Latching Energized Non-latching -011 High TDSA or Quick De-Energized Latching Independent Quick De-energized Latching Energized Non-latching -012 Low TDSA De-Energized Latching Follows Alarm TDSA De-energized Latching Energized Non-latching -013 High Quick De-Energized Non-Latching Pre-Alarm None Energized Non-Latching Energized Non-latching TDSA = "Time Domain Signal Analysis" proprietary signal processing algorithm for superior IR false alarm rejection Quick = Signal processing for explosive IR events Application Guidelines The following criteria should be considered when choosing a sensitivity level for the intended application: Speed of response based on fuel type and fire size Distance between the hazard and the flame detector These are typical industry application settings. They may not be applicable to all installations. Contact factory for additional application guidance. Offshore 001 Compressor 002 High Speed 003 Powder Coating 013 Automotive 005 Printing 001 NOTE: Latching relays cannot be used in voted systems. X9800 Single Frequency IR Flame Detector - SIL 2 Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone FM/CSA/ ATEX/IECEx X9800A4N13T1 008800-XXX AL 3/4 NPT Relay/0-20 mA X X X9800A4M13T1 008801-XXX AL M25 Relay/0-20 mA X X X9800S4N13T1 008802-XXX SS 3/4 NPT Relay/0-20 mA X X X9800S4M13T1 008803-XXX SS M25 Relay/0-20 mA X X X9800A4N13T2 008804-XXX AL 3/4 NPT Relay/0-20 mA X X X9800A4M13T2 008805-XXX AL M25 Relay/0-20 mA X X X9800S4N13T2 008806-XXX SS 3/4 NPT Relay/0-20 mA X X X9800S4M13T2 008807-XXX SS M25 Relay/0-20 mA X X X9800A4N23T1 008808-XXX AL 3/4 NPT Rly/0-20/HART X X X9800A4M23T1 008809-XXX AL M25 Rly/0-20/HART X X X9800S4N23T1 008810-XXX SS 3/4 NPT Rly/0-20/HART X X X9800S4M23T1 008811-XXX SS M25 Rly/0-20/HART X X X9800A4N23T2 008812-XXX AL 3/4 NPT Rly/0-20/HART X X X9800A4M23T2 008813-XXX AL M25 Rly/0-20/HART X X X9800S4N23T2 008814-XXX SS 3/4 NPT Rly/0-20/HART X X X9800S4M23T2 008815-XXX SS M25 Rly/0-20/HART X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table C1 to choose the correct option. The EQP detectors are completely configurable using the S3 configuration software and are shipped defaulted to the -001 setting. X9800 Single Frequency IR Flame Detector Model Part Number * Material Threads Output Div/Zone Ex d e Div/Zone Ex d FM/CSA/ ATEX/IECEx X9800A4N11W1 008700-XXX AL 3/4 NPT Relay X X X9800A4M11W1 008701-XXX AL M25 Relay X X X9800S4N11W1 008702-XXX SS 3/4 NPT Relay X X X9800S4M11W1 008703-XXX SS M25 Relay X X X9800A4N11W2 008704-XXX AL 3/4 NPT Relay X X X9800A4M11W2 008705-XXX AL M25 Relay X X X9800S4N11W2 008706-XXX SS 3/4 NPT Relay X X X9800S4M11W2 008707-XXX SS M25 Relay X X X9800A4N14W1 008716-001 AL 3/4 NPT EQP X X X9800A4M14W1 008717-001 AL M25 EQP X X X9800S4N14W1 008718-001 SS 3/4 NPT EQP X X X9800S4M14W1 008719-001 SS M25 EQP X X X9800A4N14W2 008720-001 AL 3/4 NPT EQP X X X9800A4M14W2 008721-001 AL M25 EQP X X X9800S4N14W2 008722-001 SS 3/4 NPT EQP X X X9800S4M14W2 008723-001 SS M25 EQP X X X9800A4N15W1 008724-XXX AL 3/4 NPT Pulse/Relay X X X9800A4M15W1 008725-XXX AL M25 Pulse/Relay X X X9800S4N15W1 008726-XXX SS 3/4 NPT Pulse/Relay X X X9800S4M15W1 008727-XXX SS M25 Pulse/Relay X X X9800A4N15W2 008728-XXX AL 3/4 NPT Pulse/Relay X X X9800A4M15W2 008729-XXX AL M25 Pulse/Relay X X X9800S4N15W2 008730-XXX SS 3/4 NPT Pulse/Relay X X X9800S4M15W2 008731-XXX SS M25 Pulse/Relay X X Ship Weight: Aluminum = 7lb (3.2kg) Stainless Steel = 14.6lb (6.7kg) *The last 3 digits of the part number identify the software configuration. Please see table C1 to choose the correct option. The EQP detectors are completely configurable using the S3 configuration software and are shipped defaulted to the -001 setting. X9800 Single Frequency IR Flame Detector / xWatch Camera Model Part Number * Material Threads Output Video FM/CSA X9800A3N33A2 009548-XXX AL 3/4 NPT Relay/0-20 NTSC X X9800A3M33A2 009549-XXX AL M25 Relay/0-20 NTSC X X9800S3N33A2 009550-XXX SS 3/4 NPT Relay/0-20 NTSC X X9800S3M33A2 009551-XXX SS M25 Relay/0-20 NTSC X X9800A3N43A2 009552-XXX AL 3/4 NPT Relay/0-20 PAL X X9800A3M43A2 009553-XXX AL M25 Relay/0-20 PAL X X9800S3N43A2 009554-XXX SS 3/4 NPT Relay/0-20 PAL X X9800S3M43A2 009555-XXX SS M25 Relay/0-20 PAL X X9800A3N34A2 009556-001 AL 3/4 NPT EQP NTSC X X9800A3M34A2 009557-001 AL M25 EQP NTSC X X9800S3N34A2 009558-001 SS 3/4 NPT EQP NTSC X X9800S3M34A2 009559-001 SS M25 EQP NTSC X X9800A3N44A2 009560-001 AL 3/4 NPT EQP PAL X X9800A3M44A2 009561-001 AL M25 EQP PAL X X9800S3N44A2 009562-001 SS 3/4 NPT EQP PAL X X9800S3M44A2 009563-001 SS M25 EQP PAL X Ship Weight: Aluminum = 9lb (4.1kg) Stainless Steel = 17.6lb (7.9kg) *The last 3 digits of the part number identify the software configuration. Please see table C1 to choose the correct option. The standard EQP detectors are completely configurable using the S3 software and are defaulted to the -001 setting. NOTES: 3 year warranty excludes xWatch camera. Models listed above come with a 2.3 mm lens on the camera, which emulates the 90° field of view of the flame detector. See section Flame F for additional lens options. Which other X9800 Single Frequency IR Flame Detector part numbers can PE Energy supply?The 44 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description007762-001X9800,HEAD, SS, EX D E007763-001X9800,HEAD, SS, EX D008702-001X9800S4N11W1 FLAME DETECTOR008703-001X9800S4M11W1 FLAME DETECTOR008706-001X9800S4N11W2 FLAME DETECTOR008715-001X9800S4M13W2 FLAME DETECTOR008726-001X9800S4N15W1 FLAME DETECTOR008727-001X9800S4M15W1 FLAME DETECTOR008728-001X9800A4N15W2 FLAME DETECTOR008730-001X9800S4N15W2 FLAME DETECTOR008731-001X9800S4M15W2 FLAME DETECTOR008740-001X9800A4M11R1 FLAME DETECTOR008744-001X9800A4M13R1 FLAME DETECTOR008745-001X9800S4M13R1 FLAME DETECTOR008746-001X9800A4M13R2 FLAME DETECTOR008747-001X9800S4M13R2 FLAME DETECTOR008766-001X9800A4M13U1 FLAME DETECTOR008767-001X9800S4M13U1 FLAME DETECTOR008768-001X9800A4M13U2 FLAME DETECTOR008769-001X9800S4M13U2 FLAME DETECTOR008770-001X9800A4M14R1 FLAME DETECTOR008772-001X9800A4M14R2 FLAME DETECTOR008774-001X9800A4N23W1 FLAME DETECTOR008777-001X9800S4M23W1 FLAME DETECTOR008778-001X9800A4N23W2 FLAME DETECTOR008794-001X9800A4M23R1 FLAME DETECTOR008796-001X9800A4M23R2 FLAME DETECTOR008798-001X9800A4N14R1 FLAME DETECTOR008802-001X9800S4N13T1 FLAME DETECTOR008803-001X9800S4M13T1 FLAME DETECTOR008806-001X9800S4N13T2 FLAME DETECTOR008807-001X9800S4M13T2 FLAME DETECTOR008808-001X9800A4N23T1 FLAME DETECTOR008809-001X9800A4M23T1 FLAME DETECTOR008810-001X9800S4N23T1 FLAME DETECTOR008811-001X9800S4M23T1 FLAME DETECTOR008812-001X9800A4N23T2 FLAME DETECTOR008813-001X9800A4M23T2 FLAME DETECTOR008814-001X9800S4N23T2 FLAME DETECTOR008815-001X9800S4M23T2 FLAME DETECTOR012138-001X9800, HEAD, AL, EX D E, SIL012139-001X9800, HEAD, SS, EX D E, SIL012140-001X9800, HEAD, AL, EX D, SIL012141-001X9800, HEAD, SS, EX D, SIL -

Det-Tronics 000003-107 SUN Shade, FOR Eclipse
SUN Shade, FOR Eclipse. Det-Tronics part number 000003-107 is part of the Det-Tronics flame and gas detection range. Part number 000003-107 is also written 000003107. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 001680-001 K1003A1006 6PK Window Cleaner
K1003A1006 6PK Window Cleaner. Det-Tronics part number 001680-001, model code K1003A1006, is part of the Det-Tronics flame and gas detection range. Part number 001680-001 is also written 001680001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 004083-202 C7093E9010 High Speed IR DET
C7093E9010 High Speed IR DET. Det-Tronics part number 004083-202, model code C7093E9010, is part of the Det-Tronics flame and gas detection range. Part number 004083-202 is also written 004083202. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 007168-014 PIRECLA4A2W1 GAS Detector – PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector
PIRECLA4A2W1 GAS Detector. Det-Tronics part number 007168-014, model code PIRECLA4A2W1, is part of the Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector product line. Part number 007168-014 is also written 007168014. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 007168-912 PIRECLA4A1R1 GAS Detector – PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector
PIRECLA4A1R1 GAS Detector. Det-Tronics part number 007168-912, model code PIRECLA4A1R1, is part of the Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector product line. Part number 007168-912 is also written 007168912. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 007819-002 W6300B1003, Inspector Connector
W6300B1003, Inspector Connector. Det-Tronics part number 007819-002, model code W6300B1003, is part of the Det-Tronics flame and gas detection range. Part number 007819-002 is also written 007819002. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 008512-001 X5200A4N13W2 Flame Detector – X5200 UVIR Flame Detector
X5200A4N13W2 Flame Detector. Det-Tronics part number 008512-001, model code X5200A4N13W2, is part of the Det-Tronics X5200 UVIR Flame Detector product line. Part number 008512-001 is also written 008512001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics X5200 UVIR Flame Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 009640-001 GTS Sensor MOD., Filter – GTS Toxic Gas Sensor Module (GT3000 Series)
GTS Sensor MOD., Filter. Det-Tronics part number 009640-001 is part of the Det-Tronics GTS Toxic Gas Sensor Module (GT3000 Series) product line. Part number 009640-001 is also written 009640001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics GTS Toxic Gas Sensor Module (GT3000 Series) on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 010210-001 EQ3750DW, ASH
EQ3750DW, ASH. Det-Tronics part number 010210-001, model code EQ3750DW, is part of the Det-Tronics flame and gas detection range. Part number 010210-001 is also written 010210001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 010254-081 UD10A5M25B2C Display, RLY/4-20 – FlexVu UD10 Universal Display
UD10A5M25B2C Display, RLY/4-20. Det-Tronics part number 010254-081, model code UD10A5M25B2C, is part of the Det-Tronics FlexVu UD10 Universal Display product line. Part number 010254-081 is also written 010254081. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexVu UD10 Universal Display on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 010274-903 GT3000 CAL KIT, H2S 50 PPM, Russ – GT3000 Certified Calibration Kits
GT3000 CAL KIT, H2S 50 PPM, Russ. Det-Tronics part number 010274-903, model code GT3000, is part of the Det-Tronics GT3000 Certified Calibration Kits product line. Part number 010274-903 is also written 010274903. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics GT3000 Certified Calibration Kits on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 011784-001 LS2000 Mounting Adapter 6″ – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000 Mounting Adapter 6". Det-Tronics part number 011784-001, model code LS2000, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 011784-001 is also written 011784001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 012731-803 LS2000SM18SMSK1S Line OF Sight – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000SM18SMSK1S Line OF Sight. Det-Tronics part number 012731-803, model code LS2000SM18SMSK1S, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 012731-803 is also written 012731803. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 013321-022 X5200GA4N13T2 Flame Detector – X5200 UVIR Flame Detector
X5200GA4N13T2 Flame Detector. Det-Tronics part number 013321-022, model code X5200GA4N13T2, is part of the Det-Tronics X5200 UVIR Flame Detector product line. Part number 013321-022 is also written 013321022. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics X5200 UVIR Flame Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 014023-011 UD30A3N12SA2
UD30A3N12SA2. Det-Tronics part number 014023-011, model code UD30A3N12SA2, is part of the Det-Tronics flame and gas detection range. Part number 014023-011 is also written 014023011. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 014031-002 EQ3780DT, Hsdm
EQ3780DT, Hsdm. Det-Tronics part number 014031-002, model code EQ3780DT, is part of the Det-Tronics flame and gas detection range. Part number 014031-002 is also written 014031002. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 014191-002 UD30A3N12SE2C
UD30A3N12SE2C. Det-Tronics part number 014191-002, model code UD30A3N12SE2C, is part of the Det-Tronics flame and gas detection range. Part number 014191-002 is also written 014191002. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 014255-001 LS2000 Laser Aligner Assembly – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000 Laser Aligner Assembly. Det-Tronics part number 014255-001, model code LS2000, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 014255-001 is also written 014255001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 014256-001 LS2000 Laser Aligner Target – FlexSight LS2000 Line-of-Sight Infrared Gas Detector
LS2000 Laser Aligner Target. Det-Tronics part number 014256-001, model code LS2000, is part of the Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector product line. Part number 014256-001 is also written 014256001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics FlexSight LS2000 Line-of-Sight Infrared Gas Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 014394-001 CTX10A3N2T
CTX10A3N2T. Det-Tronics part number 014394-001, model code CTX10A3N2T, is part of the Det-Tronics flame and gas detection range. Part number 014394-001 is also written 014394001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 014394-002 CTX10A3F2T
CTX10A3F2T. Det-Tronics part number 014394-002, model code CTX10A3F2T, is part of the Det-Tronics flame and gas detection range. Part number 014394-002 is also written 014394002. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics 028109-001 X3301A4M13W1 Flame Detector – X3301 Multispectrum Infrared Flame Detector
X3301A4M13W1 Flame Detector. Det-Tronics part number 028109-001, model code X3301A4M13W1, is part of the Det-Tronics X3301 Multispectrum Infrared Flame Detector product line. Part number 028109-001 is also written 028109001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics X3301 Multispectrum Infrared Flame Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 028250-001 X3301S4N23T2 Flame Detector – X3301 Multispectrum Infrared Flame Detector
X3301S4N23T2 Flame Detector. Det-Tronics part number 028250-001, model code X3301S4N23T2, is part of the Det-Tronics X3301 Multispectrum Infrared Flame Detector product line. Part number 028250-001 is also written 028250001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Product overview: Det-Tronics X3301 Multispectrum Infrared Flame Detector on PE Energy. Browse all Det-Tronics products on the Det-Tronics brand page. -

Det-Tronics 103363-001 Wrench, HEX, Metric 14, Long ARM
Wrench, HEX, Metric 14, Long ARM. Det-Tronics part number 103363-001 is part of the Det-Tronics flame and gas detection range. Part number 103363-001 is also written 103363001. PE Energy Industrial Supply, Houston, TX, supplies it on request: ask for a quote with price and lead time, or for help confirming the right configuration for your system. Browse all Det-Tronics products on the PE Energy Det-Tronics brand page. -

Det-Tronics C7050B UV Flame Detector
C7050B UV Flame Detector (Manual: 95-8214) combined with the EQ2200UVHT (95-8570) on an Eagle Quantum Premier system (or as a replacement on legacy Eagle Quantum provides fast, reliable flame detection in a wide variety of applications. The detector has the Automatic oi (optical integrity) feature, providing a continuous check of detector optical surfaces, detector sensitivity, and electronic circuitry of the detector/controller system. Not recommended for applications where welding or lightning may be present. Replaceable tube module Automatic oi High temperature, 125°C continuous duty Variable sensitivities configurable via S3 FM, CSA, ATEX, and IECEx C7050B Model Matrix MODEL DESCRIPTION C7050B Controller Based UV Flame Detector TYPE MATERIAL A Aluminum (AL) S Stainless Steel (SS) TYPE THREAD TYPE 6 1 Port TYPE THREAD TYPE E 1/2" NPT F M20 TYPE OUTPUTS 4 Pulse (Standard) TYPE TUBE MODULE OPTION E DE1888K3 (High Temperature for UVHT) TYPE OPTIONS 1H Operating Temperature 125° C TYPE APPROVAL TYPE 1 Explosion-Proof TYPE APPROVALS E ATEX/IECEx A FM/CSA C7050B Ultraviolet Flame Detectors (ATEX/IECEx) Model Part Number Material Conduit Entry Tube Module ATEX/IECEx Ship Weight C7050BS6F4E1H1E 006899-040 SS M20 DE1888K3 X 2.2 lb (1.0 kg) C7050 LENS CAP/BODY 008054-001 SS N/A N/A X 1 lb (0.45 kg) C7050B Ultraviolet Flame Detectors (FM/CSA) Model Part Number Material Conduit Entry Tube Module FM/CSA Ship Weight C7050BA6E4E1H1A 006899-037 AL 1/2 NPT DE1888K3 X 1.2 lb (0.6 kg) C7050BS6E4E1H1A 006899-038 SS 1/2 NPT DE1888K3 X 2.2 lb (1.0 kg) C7050BA6F4E1H1A 006899-039 AL M20 DE1888K3 X 1.2 lb (0.6 kg) C7050 LENS CAP/BODY 004907-021 AL N/A N/A X <1 lb (<0.45 kg) C7050 LENS CAP/BODY 004907-022 SS N/A N/A X 1 lb (0.45 kg) High temperature rating - continuous duty at 125° Celsius, for environments that normally exceed 75° Celsius operation. EQP UVHT Electronic Module* Model Part Number Enclosure Material Conduit Entry Tube Module FM/CSA/ ATEX/ IECEx Ship Weight EQ2253UVHT* 007082-001 AL 3/4" NPT N/A X 4.0 lb (1.8 kg) EQ2207UVHT* 007082-002 AL M25/M20 N/A X 4.0 lb (1.8 kg) EQ2263UVHT* 007082-003 SS 3/4" NPT N/A X 9.5 lb (4.3 kg) EQ2217UVHT* 007082-004 SS M25/M20 N/A X 9.5 lb (4.3 kg) *One (1) Electronic Module (EQxxxxUVHT) is required for use with each C7050B Detector -

Det-Tronics C7064E Sensor/Transmitter
C7064E Sensor/Transmitter (Spec Sheet: 90-1079) housing. Two-wire, stainless steel or aluminum toxic gas detector with 3/4” NPT or 20 mm threads. Purchase EC cell separately for monitoring H2S toxic gases. 4-20 mA output is proportional to EC cell measurement range Electrochemical cell sold separately For use with: - FlexVu UD10 Universal Display - U9500 Infiniti Transmitter - STB Sensor Termination Box - DCU Digital Communication Unit - R8471X Toxic Controller Optional measurement ranges available for H2S versions Hydrophobic filter provided on C7064E housings –40°C to 75°C hazardous location temperature rating C7064E H2S Electrochemical Sensor Housings (sensor sold separately) Model Part Number Toxic Gas Enclosure Threads Enclosure Material Measurement Range Approvals Other C7064E4012 004539-009 Hydrogen Sulfide 3/4 NPT SS All FM/CSA Groups C, D C7064E5012 004539-102 Hydrogen Sulfide M20 SS All FM/CSA Groups C, D C7064E6031 004539-103 Hydrogen Sulfide M20 SS All CSA Groups C, D C7064E5014 004539-105 Hydrogen Sulfide 3/4 NPT SS All FM/CSA Groups B, C, D Note: All C7064E housings above require an electrochemical sensor cell (not included) for proper operation. Shipping weight of all C7064E gas detector housings is 2.5 lbs (1.28 kg) -

Det-Tronics CGS Accessories: Rain Shields, Splash Guards, Dust Covers, Remote Calibration Cups
Rain Shields (Spec Sheet: 90-1046) protect combustible sensors from rain and snow. Splash Guards (Spec Sheet: 90-1046) protect combustible sensors from ingress due to rain or splashing water. Dust Covers (Spec Sheet: 90-1046) are recommended to protect sensors in windy, dusty, and oily environments. Porex and stainless steel filters available. Remote Calibration cups provide the means to apply calibration to a CGS gas sensor from a remote location. Tubing not included. Options include barbed fitting or ¼” compression fitting. NOTE: Only one accessory recommended to be fitted per catalytic sensor. Rain Shields Part Number Material Ship Weight 226349-001 AL 6 oz (0.17 kg) Splash Guard Part Number Material Ship Weight 006491-001 AL 2 lb (0.95 kg) Dust Covers Part Number Material Ship Weight 225312-001 SS 2 oz (0.06 kg) 226190-001 Porex* 2 oz (0.06 kg) *Porex not recommended for outdoors or temperatures above 75°C Remote Calibration Cups Part Number Use Filter Material Tube Fitting Type Ship Weight 225777-001 Indoor Porex* Barbed 0.5 lb (0.14 kg) 004996-001 Indoor Porex* Compression 0.5 lb (0.14 kg) 006618-001 Outdoor SS Screen Barbed 0.5 lb (0.14 kg) 006618-002 Outdoor SS Screen Compression 0.5 lb (0.14 kg) *Porex not recommended for outdoors or temperatures above 75°C. -

Det-Tronics CGS Combustible Gas Certified Calibration Kits
Combustible Gas Certified Calibration Kits (Spec Sheet: 90-1059) for combustible gas sensors. Kits include sturdy plastic carrying case containing: Two 3.6 ft3 (103 liters) cylinders of Class 2.2 non-flammable, non-toxic compressed gas Regulator/shutoff valve with gauge, 3-foot tubing and stainless steel CGS calibration cup Regulator provides fixed flow rate of 1 liter per minute designed for CGS sensors 3-foot tube Sturdy plastic carrying case Calibration Kits for CGS Catalytic Sensor Part Number Gas LFL % Vol Standard Balance Ship Weight 225130-002 Ethane 50% 1.5 ISO Air 11.5 lb (5.23 kg) 225130-902* Ethane 50% 1.5 ISO Air 11.5 lb (5.23 kg) 225130-003 Ethylene 50% 1.35 ISO Air 11.5 lb (5.23 kg) 225130-005 Hydrogen 50% 2.0 ISO Air 11.5 lb (5.23 kg) 225130-905* Hydrogen 50% 2.0 ISO Air 11.5 lb (5.23 kg) 225130-006 Methane 20% 1.0 ISO Air 11.5 lb (5.23 kg) 225130-007 Methane 25% 1.25 ISO Air 11.5 lb (5.23 kg) 225130-008 Methane 35% 1.75 ISO Air 11.5 lb (5.23 kg) 225130-014 Methane 50% 2.2 IEC Air 11.5 lb (5.23 kg) 225130-914* Methane 50% 2.2 IEC Air 11.5 lb (5.23 kg) 225130-001 Methane 50% 2.5 ISO Air 11.5 lb (5.23 kg) 225130-901* Methane 50% 2.5 ISO Air 11.5 lb (5.23 kg) 225130-015 Propane 50% 0.85 IEC Air 11.5 lb (5.23 kg) 225130-915* Propane 50% 0.85 IEC Air 11.5 lb (5.23 kg) 225130-004 Propane 50% 1.1 ISO Air 11.5 lb (5.23 kg) 225130-009 Empty kit–no cal gas 10 lb (4.6 kg) *These items are certified for Russian projects. NOTE: Average lead time is 2-3 weeks Replacement Gas Cylinders for Combustible Gas Calibration Kits Part Number Gas %LFL % Vol Standard Balance Ship Weight 226166-006 Zero Air N/A 20.9 N/A Nitrogen 1.5 lb (0.7 kg) 226166-002 Ethane 50% 1.5 ISO Air 1.5 lb (0.7 kg) 226166-902* Ethane 50% 1.5 ISO Air 1.5 lb (0.7 kg) 226166-003 Ethylene 50% 1.35 ISO Air 1.5 lb (0.7 kg) 226166-005 Hydrogen 50% 2.0 ISO Air 1.5 lb (0.7 kg) 226166-905* Hydrogen 50% 2.0 ISO Air 1.5 lb (0.7 kg) 226166-007 Methane 20% 1.0 ISO Air 1.5 lb (0.7 kg) 226166-008 Methane 25% 1.25 ISO Air 1.5 lb (0.7 kg) 226166-009 Methane 35% 1.75 ISO Air 1.5 lb (0.7 kg) 226166-014 Methane 50% 2.2 IEC Air 1.5 lb (0.7 kg) 226166-914* Methane 50% 2.2 IEC Air 1.5 lb (0.7 kg) 226166-001 Methane 50% 2.5 ISO Air 1.5 lb (0.7 kg) 226166-901* Methane 50% 2.5 ISO Air 1.5 lb (0.7 kg) 226166-015 Propane 50% 0.85 IEC Air 1.5 lb (0.7 kg) 226166-915* Propane 50% 0.85 IEC Air 1.5 lb (0.7 kg) 226166-004 Propane 50% 1.1 ISO Air 1.5 lb (0.7 kg) 226166-010 Propylene 50% 1.2 ISO Air 1.5 lb (0.7 kg) *These items are certified for Russian projects. Replacement Kit Replacement Parts Part Number Description Ship Weight 004976-001 Standard calibration cup, SS 8 oz (0.23 kg) 101678-007 Tubing, 3 ft. 8 oz (0.23 kg) 101678-013 Tubing, 100 ft. spool 8 oz (0.23 kg) 162552-001 1 LPM Regulator for CGS sensors 8 oz (0.23 kg) 162553-001 Carrying Case 8 oz (0.23 kg) -

Det-Tronics CGS Combustible Gas Sensor
CGS Combustible Gas Sensor (Spec Sheet: 90-1041). Stainless steel catalytic sensor that provides an accurate measurement of combustible gas concentration in the % LFL range. Requires FlexVu UD10, Model 505, U9500A or DCUEX transmitter. Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to FM 6310/6320, CSA 22.2 #154, and ATEX EN60079-29-1 Performance certified to IEC60079-29-1 when connected to the FlexVu UD10, UD10-DCU Detects hydrogen and hydrocarbon gases Constant current or constant voltage options available Poison resistant construction 3/4” NPT or 20 mm thread option Wire lead options of 6” or 30” Sensor Separation Termination Box (STB) option available Variety of special accessories available FlexVu UD10 universal display provides full digital readout, calibration and user interface Performance approved from –40°C to 75°C for life safety applications Hazardous Location approved from –55°C to 125°C for process control applications SIL2 certified when used with FlexVu UD10 Universal Display Combustible Gas Sensor for Models 505, 500, and K-Series Transmitters Model Part Number Replaces old catalytic sensor p/n Threads Lead Length FM/CSA/ATEX/IECEx Russia CGSS1A6V2R1X 006824-002 225006-002, 225957-001, 226530-001, 226531-001, 226931-001, 226931-002, 226999-002, 226999-004,223106-002 3/4 NPT 6 in X CGSS1A3V2R1X 006824-006 225006-005, 226530-004, 226531-002, 226931-003, 226931-004 3/4 NPT 30 in X CGSS1C3V2R1X 006824-008 M20 30 in X CGSS1C6V2R1X 006824-004 226999-010, 226999-013, 226999-018, 226999-019 M20 6 in X CGSS1C6V2R1R 006824-904 M20 6 in X Shipping Weight = 1 lb. (0.45 kg) NOTES: CGS sensors always require a transmitter (sold separately). Constant voltage Combustible Gas Sensor for UD10, DCUEX, U9500A, U8700, 400, 405, 810, 820, and 880 Transmitters Model Part Number Replaces old catalytic sensor p/n Threads Lead Length FM/CSA/ATEX/IECEx Russia Brazil CGSS1A6C2R1X 006824-001 225006-004, 225957-002, 226530-003, 226531-003, 226931-005, 226931-006, 226999-011, 226999-012 3/4 NPT 6 in X CGSS1A6C2R1B 006824-101 225006-003, 226530-005, 226531-004, 226931-007, 226931-008 3/4 NPT 6 in X CGSS1A3C2R1X 006824-005 3/4 NPT 30 in X CGSS1C3C2R1X 006824-007 225006-003, 226530-005, 226531-004, 226931-007, 226931-008 M20 30 in X CGSS1C6C2R1X 006824-003 226999-008, 226999-020, 226999-014, 226999-021 M20 6 in X CGSS1C6C2R1R 006824-903 M20 6 in X Shipping Weight = 1 lb. (0.45 kg) NOTES: CGS sensors always require a transmitter (sold separately). Constant current Which other CGS Combustible Gas Sensor part numbers can PE Energy supply?The 4 Det-Tronics part numbers below belong to this product line and are supplied by PE Energy Industrial Supply on request. Each row shows the factory part number and the manufacturer description as printed in the price list; ask for a quote with price and lead time, or for help matching a configuration.Part numberManufacturer description006824-011CGSS1C5C2R1X M20,FERRULES,CC006824-020CGSS1A6C2H1X, 3/4, 6LW, CC,H2006824-021CGSS1C3C2H1X, M20, 30LW, CC,H2006824-853CGSS1C6C2R1K,HOLD MCO100846 -

Det-Tronics Duct Mount and Sample Draw Assemblies for CGS
Direct Duct Mount Assembly (Spec Sheet: 90-1046). For mounting combustible sensors to air handling duct work. The Direct Duct Mount CGS assembly enables combustible gas detection in air handling, heating, ventilating, and air conditioning ducts. Designed for flat surface mounting only. Seal gaskets provided to prevent leakage Circular duct wall cutout required Positive pressure ducts only Calibration gas inlet enables in-situ calibration Flexible conduit/cabling recommended to enable sensor removal from assembly Model Q811 Duct Mount Enclosure (Manual: 95-8459) The Q811 provides combustible gas detection in air handling, heating, ventilating, and air conditioning ducts. Designed for flat surface mounting only Stainless steel NEMA 4X enclosure 316 Stainless steel enclosure and sample inlet tube spans the duct’s cross section 1 foot outlet tube returns the sample Requires a 600–4000 fpm velocity Sample Draw Cup Assembly for CGS. The Sample Draw cup assembly for CGS provides a sealed enclosure with compression fittings to enable the CGS to be used as part of an extractive gas sampling system. Aluminum enclosure with seals provides airtight flow chamber Brass compression fittings accept 1/4” OD tubing Threaded cover enables sensor removal Sampling system hardware required for proper operation Direct Duct Mount Assemblies for CGS Part Number Material Ship Weight 226846-001 AL 6 oz (0.17 kg) 226846-008 SS 1 lb (0.46 kg) Model Q811 CGS Duct Mount Enclosure Part Number Material Ship Weight Thread 000811-106 SS 10 lb (4.5 kg) M20 000811-105 SS 1 lb (0.46 kg) 3/4" NOTE: 1 inlet and 1 outlet tube included at no extra cost. Specify length of inlet tube at time of order (1, 3, 6, 10 or 13 ft). Q811 Spare Parts Part Number Description Length Material Ship Weight 000214-281 Inlet Tube 1 ft (0.3 m) 316 SS 8 oz (0.23 kg) 000214-282 Inlet Tube 3 ft (0.9 m) 316 SS 1 lb (0.45 kg) 000214-283 Inlet Tube 6 ft (1.8 m) 316 SS 3 lb (1.35 kg) 000214-284 Inlet Tube 10 ft (3.1 m) 316 SS 6 lb (2.4 kg) 000214-285 Inlet Tube 13 ft (4 m) 316 SS 9 lb (4.0 kg) 000214-419 Inlet Tube 15 ft (4.6 m) 316 SS 11 lb (5.0 kg) 000214-280 Outlet Tube 1 ft (0.3 m) 316 SS 8 oz (0.23 kg) 102359-001 Stopper Plug N/A Rubber <1 lb (<0.45 kg) Sample Draw Cup Assembly for CGS Part Number Material Ship Weight 009171-001 AL 1 lb (0.45 kg) -

Det-Tronics Electrochemical Sensor Cells for use with Model C7064E housings
Electrochemical sensor cells are provided for use with the C7064E (Spec Sheet: 90-1079) gas detector housings. All sensors are shipped in a sealed bag. Store in a cool, dry place until installation/commissioning is required. H2S Electrochemical Sensor Cell Part Number Toxic Gas Measurement Range (PPM) 005434-003 Hydrogen Sulfide 0-20 005434-004 Hydrogen Sulfide 0-50 005434-002 Hydrogen Sulfide 0-100 Shipping weight for sensor cells is 2 oz. (.1 kg) C7064E Calibration Gas Kits Part Number Concentration Gas Balance Ship Weight 227115-001 50 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-002 20 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-014 10 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-015 25 ppm Hydrogen Sulfide Nitrogen 11.5 lb (5.23 kg) 227115-008 Empty kit - no cal gas 8.5 lb (3.9 kg) C7064E Calibration Gas Kit Replacement Cylinders Part Number Concentration Gas Balance Ship Weight 227117-001 50 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-002 20 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-011 10 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) 227117-012 25 ppm Hydrogen Sulfide Nitrogen 1.5 lb (0.7 kg) C7064E Calibration Kit Replacement Parts Part Number Description Ship Weight 005964-001 C7064E Calibration cup 8 oz (0.23 kg) 101678-007 Tubing, 3 ft. 8 oz (0.23 kg) 101678-013 Tubing 100 ft. spool 8 oz (0.23 kg) 107427-084 C7064E Calibration cup O-ring 8 oz (0.23 kg) 162552-001 Regulator, 1 LPM 8 oz (0.23 kg) 162553-001 Carrying Case 8 oz (0.23 kg) -

Det-Tronics EQ2200UVHT and C7050 Detector
EQ2200UVHT (Manual: 95-8570) combined with the C7050 Detector (Manual: 95-8214) on an EQP (or as a replacement on an older EQ system) provides fast, reliable flame detection in a wide variety of applications. The detector has the Automatic oi (optical integrity) feature, providing a continuous check of detector optical surfaces, detector sensitivity, and electronic circuitry of the detector/controller system. Not recommended for applications where welding or lightning may be present. For large fixed installations only. Replaceable tube module External Automatic oi Internal Automatic oi Standard temperature option High temperature option, 125°C continuous duty Variable sensitivities available to match hazard FM, CSA, ATEX, CE C7050 Model Matrix MODEL DESCRIPTION C7050B Controller Based UV Flame Detector TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE 6 1 Port TYPE THREAD TYPE E 1/2" NPT F M20 TYPE OUTPUTS 4 Pulse (Standard) TYPE TUBE MODULE OPTION E DE1888K3 (High Temperature for UVHT) TYPE OPTIONS 1H Operating Temperature 125° C TYPE APPROVAL TYPE 1 Explosion-Proof TYPE APPROVALS E ATEX/IECEx A FM/CSA C7050B Ultraviolet Flame Detectors (ATEX/IECEx) Model Part Number Enclosure Material Conduit Entry Tube Module ATEX/ IECEx Ship Weight C7050BS6F4E1H1E 006899-040 SS M20 DE1888K3 X 2.2 lb (1.0 kg) C7050 LENS CAP/BODY 008054-001 SS N/A N/A X 1 lb (0.45 kg) High temperature rating - continuous duty at 125° Celsius, for environments that normally exceed 75° Celsius operation. C7050B Ultraviolet Flame Detectors (FM/CSA) Model Part Number Enclosure Material Conduit Entry Tube Module FM/CSA Ship Weight C7050BA6E4E1H1A 006899-037 AL 1/2" NPT DE1888K3 X 1.2 lb (0.6 kg) C7050BS6E4E1H1A 006899-038 SS 1/2" NPT DE1888K3 X 2.2 lb (1.0 kg) C7050BA6F4E1H1A 006899-039 AL M20 DE1888K3 X 1.2 lb (0.6 kg) C7050 LENS CAP/BODY 004907-021 AL N/A N/A X <1 lb (<0.45 kg) C7050 LENS CAP/BODY 004907-022 SS N/A N/A X 1 lb (0.45 kg) High temperature rating - continuous duty at 125° Celsius, for environments that normally exceed 75° Celsius operation. EQP UVHT Electronic Module* Model Part Number Enclosure Material Conduit Entry Tube Module FM/CSA/ ATEX/ IECEx Ship Weight EQ2253UVHT* 007082-001 AL 3/4" NPT N/A X 4.0 lb (1.8 kg) EQ2207UVHT* 007082-002 AL M25/M20 N/A X 4.0 lb (1.8 kg) EQ2263UVHT* 007082-003 SS 3/4" NPT N/A X 9.5 lb (4.3 kg) EQ2217UVHT* 007082-004 SS M25/M20 N/A X 9.5 lb (4.3 kg) DE6598-002 006598-002 Module only 2.5 lb (1.2 kg) *One (1) Electronic Module (EQxxxxUVHT) is required for use with each C7050B Detector -

Det-Tronics EQ2400NE Network Extender
EQ2400NE Network Extender (Spec Sheet: 90-1132) expands the capabilities of the Eagle Quantum Premier system by allowing additional nodes as well as additional wiring to be added to the LON communication loop. Without a network extender, the communication network is limited to 60 nodes on a 2,000 meter loop. Each network extender increases the capacity of the loop by 40 nodes and an additional 2,000 meters of wiring. The maximum system size is 246 field nodes and 10,000 meters of wiring. To ensure optimum performance, it is important to distribute the network extenders along the loop so that no more than 40 nodes or 2,000 meters of wiring are on either side of a network extender. Network extender circuitry supports communication in both directions. If a network fault should occur, uninterrupted communication can continue in the opposite direction. Increases network capacity by 40 nodes per unit (system maximum = 246) Each extender increases wiring length by 2,000 meters Visual indication of network traffic Up to 6 extenders can be added per system EQ24xxNE - Network Extender Model Part Number Material Thread Ports FM/CSA/ATEX Ship Weight EQ2453NE 006941-009 AL 3/4 NPT 5 X 6 lb (2.7 kg) EQ2408NE 006941-007 AL 3/4 NPT 6 X 6 lb (2.7 kg) EQ2407NE 006941-003 AL M25/M20 5 X 6 lb (2.7 kg) EQ2409NE 006941-008 AL M25/M20 6 X 6 lb (2.7 kg) EQ2463NE 006941-010 SS 3/4 NPT 5 X 10 lb (4.5 kg) EQ2417NE 006941-006 SS M25/M20 5 X 10 lb (4.5 kg) -

Det-Tronics EQ2400PLR Physical Layer Repeater
EQ2400PLR Physical Layer Repeater (spec sheet 90-XXXX) is a repeater module that is connected between two network segments. A network segment is defined as the segment between two network extenders or the segment between an EQP controller and a network extender. The purpose of the physical layer repeater is to eliminate communication interference resulting from network wiring opens caused by a break in the wire or a bad connection. An open wire will result in the reflection of the network signal back along the network wiring segment. This interference has the potential to cause a network device to fault isolate. This will occur at a device located at a certain distance from the network open. Typically the distance lies between 350 and 500 meters and is dependent upon the electrical characteristics of the network cable. Suppresses reflection Amplifies signal EQ24XX PLR Physical Layer Repeater Model Part Number Material Thread Ports FM/CSA/ATEX Ship Weight EQ2453PLR 009183-001 AL 3/4 NPT 5 X 6 lb (2.7 kg) EQ2457PLR 009183-002 AL M25/M20 6 X 6 lb (2.7 kg) EQ2463PLR 009183-003 SS 3/4 NPT 5 X 10 lb (4.5 kg) EQ2467PLR 009183-004 SS M25/M20 5 X 10 lb (4.5 kg) EQ24EMPLR 009183-005 1 lb (0.46 kg) -

Det-Tronics EQ3700 DCIO Discrete Input/Output Module
EQ3700 DCIO Input/Output Module (Spec Sheet: 90-1149) The 8 Channel DC I/O Module is specially designed to expand the Input and Output (I/O) capability of the Det-Tronics Eagle Quantum Premier System. The unit is designed to provide continuous and automated fire/gas protection while ensuring system operation through continuous supervision of system I/O and signaling line circuit (SLC). The DCIO module provides eight channels of configurable I/O points that can be programmed for supervised or unsupervised operation. Each input point can accept fire detection devices such as heat, smoke, or unitized flame detectors. Each output point can be configured for signaling or releasing output operation. Each channel on the module is provided with individual indicators for active and fault conditions. Monitors eight independent I/O channels IDC Class B wiring Class 1 Div. 2 locations combined with Zone 2 rated devices Type N Individual channels are configurable as an Input or Output Individual point Style is configurable as a supervised or an unsupervised point Individual point Type is configurable for alarm/supervisory/other input styles, notification/releasing/dry contact output Meets the requirements of NFPA 72 Panel or DIN rail mounting EQ3700 DCIO Model Matrix MODEL DESCRIPTION EQ3700 8 Channel Discrete Input/Output Module (DCIO) TYPE MOUNTING OPTION D Din Rail P Panel TYPE APPROVALS R VNIIPO/VNIIFTRI (RUSSIA) W FM/CSA/ATEX/IECEx EQ3700 DCIO Module Model Part Number Material FM/CSA/ ATEX/IECEx Ship Weight EQ3700PW 007371-002 AL X 1.0 lb (0.45 kg) EQ3700DW 007371-003 AL X 2.0 lb (0.90 kg)