Oldham Simtronics
Showing 1261–1305 of 2140 results
-

Oldham Simtronics CTX300-513 CTX 300 without display R507 0-2000 ppm
$1,030.00CTX 300 without display R507 0-2000 ppm. Part number CTX300-513 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-514 CTX 300 without display R410A 0-1000 ppm
$1,030.00CTX 300 without display R410A 0-1000 ppm. Part number CTX300-514 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-515 CTX 300 without display R32 0-1000 ppm
$1,030.00CTX 300 without display R32 0-1000 ppm. Part number CTX300-515 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-517 CTX 300 without display R407C 0-1000 ppm
$1,030.00CTX 300 without display R407C 0-1000 ppm. Part number CTX300-517 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-518 CTX 300 without display R408A 0-4000 ppm
$1,030.00CTX 300 without display R408A 0-4000 ppm. Part number CTX300-518 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-519 CTX 300 without display R407F 0-1000 ppm
$1,030.00CTX 300 without display R407F 0-1000 ppm. Part number CTX300-519 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-520 CTX 300 without display R434A (RS45) 0-4000 ppm
$1,030.00CTX 300 without display R434A (RS45) 0-4000 ppm. Part number CTX300-520 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-521 CTX 300 without display R245FA 0-1000 ppm
$1,030.00CTX 300 without display R245FA 0-1000 ppm. Part number CTX300-521 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-524 CTX 300 without display R422D 0-4000 ppm
$1,030.00CTX 300 without display R422D 0-4000 ppm. Part number CTX300-524 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-525 CTX 300 without display HFO-1234ze 0-1,000 ppm
$1,030.00CTX 300 without display HFO-1234ze 0-1,000 ppm. Part number CTX300-525 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-656 CTX 300 without display Ethanol 0-500 ppm
$1,030.00CTX 300 without display Ethanol 0-500 ppm. Part number CTX300-656 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-657 CTX 300 without display Toluene 0-500 ppm
$1,030.00CTX 300 without display Toluene 0-500 ppm. Part number CTX300-657 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-658 CTX 300 without display Isopropanol 0-500 ppm
$1,030.00CTX 300 without display Isopropanol 0-500 ppm. Part number CTX300-658 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-659 CTX 300 without display 2-Butanone 0-500 ppm
$1,030.00CTX 300 without display 2-Butanone 0-500 ppm. Part number CTX300-659 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-660 CTX 300 without display Xylene 0-500 ppm
$1,030.00CTX 300 without display Xylene 0-500 ppm. Part number CTX300-660 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics CTX300-662 CTX 300 without display HFO-1234yf 0-1,000 ppm
$1,030.00CTX 300 without display HFO-1234yf 0-1,000 ppm. Part number CTX300-662 belongs to the Teledyne Gas and Flame Detection (Oldham) CTX 300 product line. List price $1,030.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics CTX 300 Fixed Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DF-RV7-XTA0-0XL-00 3IR DF-TV7, Standard range, LON protocol
$4,865.00What is the Oldham Simtronics DF-RV7-XTA0-0XL-00?The Oldham Simtronics DF-RV7-XTA0-0XL-00 is: 3IR DF-TV7, Standard range, LON protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-RV7-XTA0-0XL-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-RV7-XTA0-0XL-0N 3IR DF-TV7, Standard range, LON protocol
$4,865.00What is the Oldham Simtronics DF-RV7-XTA0-0XL-0N?The Oldham Simtronics DF-RV7-XTA0-0XL-0N is: 3IR DF-TV7, Standard range, LON protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-RV7-XTA0-0XL-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-RV7-XTB0-0XL-00 3IR DF-TV7, Long range, LON protocol
$4,865.00What is the Oldham Simtronics DF-RV7-XTB0-0XL-00?The Oldham Simtronics DF-RV7-XTB0-0XL-00 is: 3IR DF-TV7, Long range, LON protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-RV7-XTB0-0XL-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-RV7-XTB0-0XL-0N 3IR DF-TV7, Long range, LON protocol
$4,865.00What is the Oldham Simtronics DF-RV7-XTB0-0XL-0N?The Oldham Simtronics DF-RV7-XTB0-0XL-0N is: 3IR DF-TV7, Long range, LON protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-RV7-XTB0-0XL-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-RV7-XVA0-0XL-00 UV2IR DF-TV7, Standard range, LON protocol
$5,590.00What is the Oldham Simtronics DF-RV7-XVA0-0XL-00?The Oldham Simtronics DF-RV7-XVA0-0XL-00 is: UV2IR DF-TV7, Standard range, LON protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-RV7-XVA0-0XL-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-RV7-XVA0-0XL-0N UV2IR DF-TV7, Standard range, LON protocol
$5,590.00What is the Oldham Simtronics DF-RV7-XVA0-0XL-0N?The Oldham Simtronics DF-RV7-XVA0-0XL-0N is: UV2IR DF-TV7, Standard range, LON protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-RV7-XVA0-0XL-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTA0-0XC-00 3IR DF-TV7, Standard range, Configurable output
$4,330.00What is the Oldham Simtronics DF-TV7-XTA0-0XC-00?The Oldham Simtronics DF-TV7-XTA0-0XC-00 is: 3IR DF-TV7, Standard range, Configurable output. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTA0-0XC-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTA0-0XC-0N 3IR DF-TV7, Standard range, Configurable output
$4,330.00What is the Oldham Simtronics DF-TV7-XTA0-0XC-0N?The Oldham Simtronics DF-TV7-XTA0-0XC-0N is: 3IR DF-TV7, Standard range, Configurable output. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTA0-0XC-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTA0-0XH-00 3IR DF-TV7, Standard range, HART protocol
$4,540.00What is the Oldham Simtronics DF-TV7-XTA0-0XH-00?The Oldham Simtronics DF-TV7-XTA0-0XH-00 is: 3IR DF-TV7, Standard range, HART protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTA0-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTA0-0XH-0N 3IR DF-TV7, Standard range, HART protocol
$4,540.00What is the Oldham Simtronics DF-TV7-XTA0-0XH-0N?The Oldham Simtronics DF-TV7-XTA0-0XH-0N is: 3IR DF-TV7, Standard range, HART protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTA0-0XH-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTB0-0XC-00 3IR DF-TV7, Long range, Configurable output
$4,330.00What is the Oldham Simtronics DF-TV7-XTB0-0XC-00?The Oldham Simtronics DF-TV7-XTB0-0XC-00 is: 3IR DF-TV7, Long range, Configurable output. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTB0-0XC-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTB0-0XC-0N 3IR DF-TV7, Long range, Configurable output
$4,330.00What is the Oldham Simtronics DF-TV7-XTB0-0XC-0N?The Oldham Simtronics DF-TV7-XTB0-0XC-0N is: 3IR DF-TV7, Long range, Configurable output. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTB0-0XC-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTB0-0XH-00 3IR DF-TV7, Long range, HART protocol
$4,540.00What is the Oldham Simtronics DF-TV7-XTB0-0XH-00?The Oldham Simtronics DF-TV7-XTB0-0XH-00 is: 3IR DF-TV7, Long range, HART protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTB0-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XTB0-0XH-0N 3IR DF-TV7, Long range, HART protocol
$4,540.00What is the Oldham Simtronics DF-TV7-XTB0-0XH-0N?The Oldham Simtronics DF-TV7-XTB0-0XH-0N is: 3IR DF-TV7, Long range, HART protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XTB0-0XH-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XVA0-0XC-00 UV2IR DF-TV7, Standard range, Configurable output
$5,045.00What is the Oldham Simtronics DF-TV7-XVA0-0XC-00?The Oldham Simtronics DF-TV7-XVA0-0XC-00 is: UV2IR DF-TV7, Standard range, Configurable output. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XVA0-0XC-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XVA0-0XC-0N UV2IR DF-TV7, Standard range, Configurable output
$5,045.00What is the Oldham Simtronics DF-TV7-XVA0-0XC-0N?The Oldham Simtronics DF-TV7-XVA0-0XC-0N is: UV2IR DF-TV7, Standard range, Configurable output. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XVA0-0XC-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XVA0-0XH-00 UV2IR DF-TV7, Standard range, HART protocol
$5,255.00What is the Oldham Simtronics DF-TV7-XVA0-0XH-00?The Oldham Simtronics DF-TV7-XVA0-0XH-00 is: UV2IR DF-TV7, Standard range, HART protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XVA0-0XH-00 on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DF-TV7-XVA0-0XH-0N UV2IR DF-TV7, Standard range, HART protocol
$5,255.00What is the Oldham Simtronics DF-TV7-XVA0-0XH-0N?The Oldham Simtronics DF-TV7-XVA0-0XH-0N is: UV2IR DF-TV7, Standard range, HART protocol. The MultiFlame DF-TV7 is an optical flame detector for hydrocarbon fires, designed around minimising false alarms and fitted with an intelligent optical self-test. The family has two detection technologies: the DF-TV7-T reads three separate infrared wavelengths and detects hydrocarbon fires up to 80 metres away, and the DF-TV7-V combines ultraviolet with double infrared for higher immunity to false alarms and a shorter response time, detecting hydrocarbon fires up to 45 metres away. The detector connects directly to conventional fire controllers or to a PLC, and a DF-RV7 variant exists for the addressable SYNTEL network. Configuration, including time delay, sensitivity and output behaviour, is done with the TLU600 hazardous area remote terminal or over HART with a TLH710 or TLH720.What are the specifications of the MultiFlame DF-TV7 Flame Detectors?Detection technologies: triple infrared (DF-TV7-T) and ultraviolet with double infrared (DF-TV7-V)Detection distance: up to 80 m for the triple IR version, up to 45 m for the UV/2IR versionField of view up to 120 degrees, per the vendor product overviewOutputs: 4-20 mA, relays, HART as an option, and LonWorks for the SYNTEL systemPower supply 24 V DC (18 to 35 V DC on DF-T#7 versions, 18 to 30 V DC on DF-R#7)Typical power consumption 1.4 W for IR3 and 1.5 W for UV2IR, 5 W maximumOperating and storage temperature: -40 C to +65 CHumidity 95% RH non condensing, protection rating IP66Explosion proof housing in 316 L stainless steel, weight 5.1 kgPerformance certified to EN 54-10/A1, RFI and EMI to EN 50130-4, SIL 2 capableWhat should you check before ordering?The two technologies in this family are not interchangeable and the difference is measurable rather than a matter of preference: the triple IR version reaches 80 metres and is aimed at smoky hydrocarbon fires that are hard to see optically, while the UV/2IR version trades reach for speed and false alarm immunity and reaches 45 metres. Published MTBF also separates them, at 172,000 hours for the DF-TV7-T against 115,000 hours for the DF-TV7-V. One exception is worth catching at specification time: the manual states that reference DF-V7-XT0-0-0-0---1 is neither EN 54-10 compliant nor SIL compliant, so a site with an EN 54-10 requirement cannot take that particular reference.How do the part numbers differ?Part numbers separate the detection technology (XT for triple infrared, XV for ultraviolet with double infrared), the range (A standard, B long), the output (C configurable, H HART, L LON for the SYNTEL network), and the DF-RV7 prefix marks the addressable SYNTEL variant. Published detection distances are test figures: sensitivity in the field also depends on fuel type, fire size, atmospheric conditions such as wind, rain and fog, and the angle between the fire and the detector.Where is it used?Typical service: Refineries and chemical plants; Drilling and production platforms, and FPSO vessels; Fuel loading facilities and compressor stations; LNG and LPG processing and storage; Gas turbines and aircraft hangars; Stadia and gymnasia.How do I order or get a quote?PE Energy supplies the Oldham Simtronics DF-TV7-XVA0-0XH-0N on a quote basis: send the part number with your application details and we return pricing and lead time. Fixed gas and flame detection is quoted rather than listed because most references ship configured for target gas, range, approval scope and cable entry, and those choices are fixed at the part number. This part belongs to the same product line as the MultiFlame DF-TV7 optical flame detector line already in our catalogue. -

Oldham Simtronics DG-RT7-30BC-KXL-K0 DG-RT7 H2, Hydrogen 0-5% Vol., LON protocol
$4,435.00DG-RT7 H2, Hydrogen 0-5% Vol., LON protocol. Part number DG-RT7-30BC-KXL-K0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiTox product line. List price $4,435.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DGi-TT7-E Electrochemical Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RT7-30BG-KXL-K0 DG-RT7 H2, Hydrogen 0-100% Vol., LON protocol
$4,435.00DG-RT7 H2, Hydrogen 0-100% Vol., LON protocol. Part number DG-RT7-30BG-KXL-K0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiTox product line. List price $4,435.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DGi-TT7-E Electrochemical Toxic Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-02DG-XXL-X0 DG-RX7 C2H2, Acetylene 0-100% LEL, LON protocol
$2,685.00DG-RX7 C2H2, Acetylene 0-100% LEL, LON protocol. Part number DG-RX7-02DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-03DG-XXL-X0 DG-RX7 C2H4, Ethylène 0-100% LEL, LON protocol
$2,685.00DG-RX7 C2H4, Ethylène 0-100% LEL, LON protocol. Part number DG-RX7-03DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-04DG-XXL-X0 DG-RX7 C2H4O, Ethylene Oxide 0-100% LEL, LON protocol
$2,685.00DG-RX7 C2H4O, Ethylene Oxide 0-100% LEL, LON protocol. Part number DG-RX7-04DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-05DG-XXL-X0 DG-RX7 C2H6O, Ethanol 0-100% LEL, LON protocol
$2,685.00DG-RX7 C2H6O, Ethanol 0-100% LEL, LON protocol. Part number DG-RX7-05DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-07DG-XXL-X0 DG-RX7 C3H6, Propene 0-100% LEL, LON protocol
$2,685.00DG-RX7 C3H6, Propene 0-100% LEL, LON protocol. Part number DG-RX7-07DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-09DG-XXL-X0 DG-RX7 C3H8, Propane 0-100% LEL, LON protocol
$2,685.00DG-RX7 C3H8, Propane 0-100% LEL, LON protocol. Part number DG-RX7-09DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-10DG-XXL-X0 DG-RX7 i-C4H10, i-Butane 0-100% LEL, LON protocol
$2,685.00DG-RX7 i-C4H10, i-Butane 0-100% LEL, LON protocol. Part number DG-RX7-10DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-11DG-XXL-X0 DG-RX7 C5H12, Pentane 0-100% LEL, LON protocol
$2,685.00DG-RX7 C5H12, Pentane 0-100% LEL, LON protocol. Part number DG-RX7-11DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page. -

Oldham Simtronics DG-RX7-12DG-XXL-X0 DG-RX7 C6H14, Hexane 0-100% LEL, LON protocol
$2,685.00DG-RX7 C6H14, Hexane 0-100% LEL, LON protocol. Part number DG-RX7-12DG-XXL-X0 belongs to the Teledyne Gas and Flame Detection (Oldham) MultiXplo product line. List price $2,685.00 USD per each. Supplied by PE Energy Industrial Supply, Houston, TX. Request a quote for volume pricing, lead time or help choosing the right configuration. Product overview: Oldham Simtronics DG-TX7 Intelligent Flammable Gas Detector on PE Energy. Browse all Oldham Simtronics products on the Oldham Simtronics brand page.