Ventilation
Showing 226–238 of 238 results
-
Sale!

Ramfan UB20 M.E.D. Manhole Entry System
$1,303.40 – $1,447.80Price range: $1,303.40 through $1,447.808'' Electric Blowers - AC Ramfan UB20 M.E.D. Manhole Entry System - 115V 115V powered blower System includes: 1 ea ED7002 - 8'' 1/3HP Blower-Exhauster - 115V/240v 50/60 Hz Ships as 115V 1 ea ED7004CL/DS - Quick-Couple Long Canister, 2 pcs (8'') duct - (5ft and 15ft) and duct coupler 1 ea MED5100 - M-E-D, Manhole Entry Device, Includes: MED Vent, Elbow, Mount (No Blower) Ramfan UB20 M.E.D. Manhole Entry System - 12VDC 12VDC powered blower System includes: 1 ea ED7004CL/DS - Quick-Couple Long Canister, 2 pcs (8'') duct - (5ft and 15ft) and duct coupler 1 ea ED9002 - 8'' 1/3HP Blower-Exhauster - Battery Clips (ED-SMHBC15) - 12VDC 1 ea MED5100 - M-E-D, Manhole Entry Device, Includes: MED Vent, Elbow, Mount (No Blower Part Numbers: ED7015-MED - Ramfan UB20 M.E.D. Manhole Entry System - 115V ED9015-MED - Ramfan UB20 M.E.D. Manhole Entry System - 12VDC -

RamFan WA0411 10″ (25cm) Duct Adapter
10″ (25cm) with Snap-Lock-2 required/blower Individual products may have different appearances. -

RamFan WA0511 12″ (30cm) Duct Adapter
12″ (30cm), for use with belted duct-2 required/blower Individual products may have different appearances. -

RamFan WA5001BSP 8″/20 cm WF20 Portable Ventilator
No portable blower in the world compares with the smoke removal rates of the WF20 connected to ducting from 10" to 12". Warships at general quarters require powerful suction to remove smoke from interior spaces. The WF20 suctions the smoke from the affected areas through long lengths of ducting to the outside air. The WF20 blower uses the water pressure energy of a fire hose and a patented turbine, coupled to a high-efficiency fan blade, to generate high-velocity, high-pressure airflow. The modular construction, choice of corrosion-resistant materials and simplicity assures infrequent and simple maintenance. Specifications Model WF20 Part Number WA5001BSP Ducted Airflow 1,835 cfm @ 150 psi 3,120 m3/hr @ 1.0 MPa PPV Airflow (with Multiplier) 13,125 cfm @ 150 psi (22,313 m3/hr @ 1.0 MPa) 16,511 cfm @ 250 psi (28,069 m3/hr @ 1.7 MPa) Weight 35 lbs / 15.9 kg Dimensions (h/w/d) 16 x 12 x 12 in / 40 x 31 x 31 cm Pressure/Flow Nominal: 40 psi/29 gpm (0.3 MPa/109 lpm) Max: 250 psi/94 gpm (1.75 MPa/355 lpm) Power 4.6Hp @ 150 psi (3.4 kW @ 1.0 MPa) 8Hp @ 250 psi (6kw @ 1.7 MPa) Connections 1.5" (3.8 cm) NST (NH), NPSH, or BSP male connections Certifications AMCA CE Air Flow (Single Door) 10,600 Cfm (18,000 M³/Hr) Ducted 1,835 Cfm (3,520 M³/Hr) -

RamFan WA5001N 8″/20 cm WF20 Portable Ventilator
No portable blower in the world compares with the smoke removal rates of the WF20 connected to ducting from 10" to 12". Warships at general quarters require powerful suction to remove smoke from interior spaces. The WF20 suctions the smoke from the affected areas through long lengths of ducting to the outside air. The WF20 blower uses the water pressure energy of a fire hose and a patented turbine, coupled to a high-efficiency fan blade, to generate high-velocity, high-pressure airflow. The modular construction, choice of corrosion-resistant materials and simplicity assures infrequent and simple maintenance. Specifications Model WF20 Part Number WA5001N Ducted Airflow 1,835 cfm @ 150 psi 3,120 m3/hr @ 1.0 MPa PPV Airflow (with Multiplier) 13,125 cfm @ 150 psi (22,313 m3/hr @ 1.0 MPa) 16,511 cfm @ 250 psi (28,069 m3/hr @ 1.7 MPa) Weight 35 lbs / 15.9 kg Dimensions (h/w/d) 16 x 12 x 12 in / 40 x 31 x 31 cm Pressure/Flow Nominal: 40 psi/29 gpm (0.3 MPa/109 lpm) Max: 250 psi/94 gpm (1.75 MPa/355 lpm) Power 4.6Hp @ 150 psi (3.4 kW @ 1.0 MPa) 8Hp @ 250 psi (6kw @ 1.7 MPa) Connections 1.5" (3.8 cm) NST (NH), NPSH, or BSP male connections Certifications AMCA CE Air Flow (Single Door) 10,600 Cfm (18,000 M³/Hr) Ducted 1,835 Cfm (3,520 M³/Hr) -

RamFan WA5001NH 8″/20 cm WF20 Portable Ventilator
No portable blower in the world compares with the smoke removal rates of the WF20 connected to ducting from 10" to 12". Warships at general quarters require powerful suction to remove smoke from interior spaces. The WF20 suctions the smoke from the affected areas through long lengths of ducting to the outside air. The WF20 blower uses the water pressure energy of a fire hose and a patented turbine, coupled to a high-efficiency fan blade, to generate high-velocity, high-pressure airflow. The modular construction, choice of corrosion-resistant materials and simplicity assures infrequent and simple maintenance. Specifications Model WF20 Part Number WA5001NH Ducted Airflow 1,835 cfm @ 150 psi 3,120 m3/hr @ 1.0 MPa PPV Airflow (with Multiplier) 13,125 cfm @ 150 psi (22,313 m3/hr @ 1.0 MPa) 16,511 cfm @ 250 psi (28,069 m3/hr @ 1.7 MPa) Weight 35 lbs / 15.9 kg Dimensions (h/w/d) 16 x 12 x 12 in / 40 x 31 x 31 cm Pressure/Flow Nominal: 40 psi/29 gpm (0.3 MPa/109 lpm) Max: 250 psi/94 gpm (1.75 MPa/355 lpm) Power 4.6Hp @ 150 psi (3.4 kW @ 1.0 MPa) 8Hp @ 250 psi (6kw @ 1.7 MPa) Connections 1.5" (3.8 cm) NST (NH), NPSH, or BSP male connections Certifications AMCA CE Air Flow (Single Door) 10,600 Cfm (18,000 M³/Hr) Ducted 1,835 Cfm (3,520 M³/Hr) -
Sale!

RamFan WB5001LB Water-powered Ventilator
$3,275.00Original price was: $3,275.00.$3,111.25Current price is: $3,111.25.Water PoweredPositive Pressure Ventilators1.5" BSP inlet/outlet -

RamFan WB5001LNH Water-powered Ventilator
$2,248.25Water PoweredPositive Pressure Ventilators1.5" NST/NH inlet -
Sale!

RamFan WD5010 WF540 Water-powered Ventilator
$5,452.00Original price was: $5,452.00.$5,179.40Current price is: $5,179.40.Water PoweredPositive Pressure Ventilatorswith 1.5" BSP Inlet, 2.5" Outlet -
Sale!

RamFan WK5001 WX500 Water-powered Ventilator
$4,270.00Original price was: $4,270.00.$4,056.50Current price is: $4,056.50.Water Powered WX500 Water-powered Ventilator - 1.5" BSP in/2.5" BSP out, Integrated Mister -

RamFan ZAGAY-2 Multiplier/Mister
WF20 Multiplier/Mister ZAG Adapter-AFNOR DN 300 Type M (French Norm) -

THE BULLDOG MFH Portable Fan Heater T3 Model
EXHEAT Industrial’s MFH ‘The Bulldog’® Portable Fan Heater is the world’s first truly portable hazardous area fan assisted heater. It combines efficient design with simple functionality to provide a portable heating solution for use in Zone 1 or 2 (IIA, IIB and H2) hazardous environments. Certified to the new EN 80079-36 and EN 80079-37 standards for constructional safety, The Bulldog comes ready to ‘plug and play’ with the option of fitting a plug, or hard wiring to an isolator unit. Robust Design: Compact and rigid housing suitable for onshore and offshore usage. Approved for the North Sea: For applications Onshore and Offshore including the Rental market Portable and Lightweight: Suitable for single user operation, with the addition of anti-static castors. Can be supplied on a long flying lead to get heat where you need it. Up to 6kW: Heat can be directed to target a single individual or warm a mid-sized room to comfortable operating temperatures. Direct Efficiency: Provides warm flow of air for operators at up to 5m. Cold Resistant: Suitable for ambient temperatures as low as -40°C and up to +40°C. Temperature-Specific Options: Available in T3 and T4 temperature classes. Specifications Certification ATEX II 2 G D Ex h Ex db eb IIB + H2 T3 to T4 Gb Ex tb IIIC T200°C to T135°C Db IECEx Ex db eb IIB + H2 T3 to T4 Gb Ex tb IIIC T200°C to T135°C Db Zones Zones 1 & 2 for Gas and Zones 21 & 22 for Dust Main Materials Casing: PA66 30% with EMI shielding Impeller: PA66 30% with EMI shielding with epoxy coated aluminium hub Ex d Enclosure: Anodised extruded aluminium Ex e Enclosure: Stainless steel Motor Housing: Epoxy coated aluminium Mounting Adjustable feet at each corner allow for a stable standing on uneven surfaces Voltage Single phase 220V, 230V, 240V, 254V & 277V, three phase 380V, 400V, 415V, 440V, 480V & 690V 50/60Hz Element Finned stainless steel tubular elements Dimensions Length 475mm, width 470mm, height 530mm Ingress Protection IP65 Weight 30kg, excluding cable and any optional components Trademark EU IPO trademark registration number 06118069 Model Voltage (V) Phase T Class Nominal Output (kW) Air Flow approx. (m³/hr) Air Temp. Delta approx (°C) Max Current (A) 50Hz 60Hz 50Hz 60Hz MFH-6-230 230/220 1 T3 6/5.5 1050 1260 17.7 14.7 26.7 MFH-6-254 254/240 1 T3 6/5.5 1050 1260 17.7 14.7 24.2 MFH-6-277 277 1 T3 6 1050 1260 17.7 14.7 22.3 MFH-6-400 400/380 3 T3 6/5.5 1050 1260 17.7 14.7 9.3 MFH-6-440 440/415 3 T3 6/5.5 1050 1260 17.7 14.7 8.5 MFH-6-480 480 3 T3 6 1050 1260 17.7 14.7 7.8 MFH-6-600 600 3 T3 6 1050 1260 18.9 15.9 6.4 MFH-6-690 690 3 T3 6 1050 1260 18.9 15.9 5.6 Brochure: Fan Heaters IECEx ITS 17.0012X Certificate ITS17 ATEX 101743X Certificate Installation Manual: MFH Installation Manual: MFH Ducting CU TR Certificate Datasheet: MFH -

THE BULLDOG MFH Portable Fan Heater T4 Model
EXHEAT Industrial’s MFH ‘The Bulldog’® Portable Fan Heater is the world’s first truly portable hazardous area fan assisted heater. It combines efficient design with simple functionality to provide a portable heating solution for use in Zone 1 or 2 (IIA, IIB and H2) hazardous environments. Certified to the new EN 80079-36 and EN 80079-37 standards for constructional safety, The Bulldog comes ready to ‘plug and play’ with the option of fitting a plug, or hard wiring to an isolator unit. Robust Design: Compact and rigid housing suitable for onshore and offshore usage. Approved for the North Sea: For applications Onshore and Offshore including the Rental market Portable and Lightweight: Suitable for single user operation, with the addition of anti-static castors. Can be supplied on a long flying lead to get heat where you need it. Up to 6kW: Heat can be directed to target a single individual or warm a mid-sized room to comfortable operating temperatures. Direct Efficiency: Provides warm flow of air for operators at up to 5m. Cold Resistant: Suitable for ambient temperatures as low as -40°C and up to +40°C. Temperature-Specific Options: Available in T3 and T4 temperature classes. Specifications Certification ATEX II 2 G D Ex h Ex db eb IIB + H2 T3 to T4 Gb Ex tb IIIC T200°C to T135°C Db IECEx Ex db eb IIB + H2 T3 to T4 Gb Ex tb IIIC T200°C to T135°C Db Zones Zones 1 & 2 for Gas and Zones 21 & 22 for Dust Main Materials Casing: PA66 30% with EMI shielding Impeller: PA66 30% with EMI shielding with epoxy coated aluminium hub Ex d Enclosure: Anodised extruded aluminium Ex e Enclosure: Stainless steel Motor Housing: Epoxy coated aluminium Mounting Adjustable feet at each corner allow for a stable standing on uneven surfaces Voltage Single phase 220V, 230V, 240V, 254V & 277V, three phase 380V, 400V, 415V, 440V, 480V & 690V 50/60Hz Element Finned stainless steel tubular elements Dimensions Length 475mm, width 470mm, height 530mm Ingress Protection IP65 Weight 30kg, excluding cable and any optional components Trademark EU IPO trademark registration number 06118069 Model Voltage (V) Phase T Class Nominal Output (kW) Air Flow approx. (m³/hr) Air Temp. Delta approx (°C) Max Current (A) 50Hz 60Hz 50Hz 60Hz MFH-3-230 230/220 1 T4 3/2.75 1050 1260 8.8 7.4 13.6 MFH-3-254 254/240 1 T4 3/2.75 1050 1260 8.8 7.4 12.4 MFH-3-277 277 1 T4 3 1050 1260 8.8 7.4 11.4 MFH-3-400 400/380 3 T4 3/2.75 1050 1260 8.8 7.4 4.9 MFH-3-440 440/415 3 T4 3/2.75 1050 1260 8.8 7.4 4.6 MFH-3-480 480 3 T4 3 1050 1260 8.8 7.4 4.3 MFH-3.7-600 600 3 T4 3.7 1050 1260 10.9 9.1 4.2 MFH-3.7-690 690 3 T4 3.7 1050 1260 10.9 9.1 3.7 Brochure: Fan Heaters IECEx ITS 17.0012X Certificate ITS17 ATEX 101743X Certificate Installation Manual: MFH Installation Manual: MFH Ducting CU TR Certificate Datasheet: MFH