Teledyne 8864 Controller – Multichannel Gas And Flame Monitoring System

SKU: Teledyne-8864
Manufacturer:
Teledyne

Bulk Orders

Competitive Pricing
Short Lead Times
Consolidated Shipping
Prompt Response
Request a Quote

The 8864 controller provides simultaneous display and alarm functions for up to 64 input variables. 16, 32, 48, and 64 channel display modes, and I/O modules arranged in groups of 16 channels, allow economical configuration of systems. This easy-to-configure, user friendly controller is ideal for centralizing display and alarm functions in critical multipoint monitoring applications. The similarity in function and user interface between the 8864 and the 16 channel 8800 makes usage of this family of controllers straightforward where both are used.

Features

  • 16, 32, 48, & 64 channel display modes accept inputs from many sensor types and signal ranges. Input types include 4-20mA, Modbus, and wireless options.
  • Ethernet with Modbus TCP serves/client and web server for configuration and monitoring
  • RS-485 serial ports allow simultaneous Modbus Master/ Slave operation. Two standard ports and two optional isolated ports
  • Three independent alarm levels per channel. “Relay Acknowledge” feature allows silencing of external audible devices during alarm conditions
  • QVGA Color LCD displays monitored data as trends, bar graphs and engineering units. Readouts change colors to indicate alarms
  • CSA certified for Division 2 potentially hazardous areas
  • Five standard SPDT 5-amp alarm relays. HORN, FAULT and three programmable alarm relays
  • Options cards such as 4-20mA inputs, 4-20mA outputs, discrete and programmable alarm relays and bridge sensor inputs
  • Cal Mode offers push-button zero/span calibration for remote sensor applications
  • Authorization Mode allows locking of critical settings
  • Data Logger onto SD card allows recording of minimum, maximum, and average values for one year
  • Power supply options include both 150 and 600 Watt
  • Magnetic keypad standard for non-intrusive operation in potentially hazardous locations
  • Enclosures include wall mount NEMA 4X – Non- Metallic, 316 SS, XP and Rack/Panel Mount

8864 Controller

Input 12 bit 4-20mA into 150 ohms input impedance; includes +power supply terminals for each channel for routing power to two or three wire transmitters
Serial Ports Modbus Master and Slave RS485 ports equipped with Tx / Rx LEDs
Ethernet Port Modbus TCP Master/Slave port with web server (Gateway for Ethernet IP, Bacnet, and other protocols available)
Alarm Relays 5 amp 30VDC or 250VAC resistive Form C
Analog Outputs (Optional) 16 bit 4-20mA output. Max load 800 ohms with nominal 24VDC power supply
Bridge Inputs
(Optional)
12 bit, 16 channel bridge input
Display QVGA 320 x 240 pixel TFT graphic LCD with LED backlight5 LEDs show standard relay alarm status
Ambient Temperature Range -25 – +60 degrees C
Power Supply 10 – 30VDC (24VDC nominal)
12 Watts max required
10-0172 option = 150 Watt
10-0307 option = 600 Watt
Approvals CSA C22.2 No 1010.1 and C22.2 No.152
for combustibles and ISA S82.02 UL 1604 / C22.2
No 213 (NEMA 4X = Division 2 Groups A,B,C,D,)
EN55011 and EN61000 (CE Mark)

 

MAIN DATA SCREEN MAIN DATA SCREEN
Displays all active channels on the same screen.
Channel configurations include 16, active channels. Cells indicate
alarm status by color.
BAR GRAPH SCREEN BAR GRAPH SCREEN
Displays 16 channels at a time. Bar graphs change colors to indicate alarm status.
24 HOUR TREND SCREEN 24 HOUR TREND SCREEN
Displays 1 channel at a time as most recent 24 hour trend. Top data fields include current reading, max – min – average readings over the 24 hours, range, channel ID and engineering units.
COMBINATION SCREEN COMBINATION SCREEN
Displays 1 channel at a time as most recent 30-minute trend, bar
graph and large engineering units. Top data fields include current
reading, max – min -average readings for trouble shooting, range,
channel ID, and engineering units. Readings change color and flash on alarms. Flashing color becomes steady after acknowledge.
ZONE SCREEN ZONE SCREEN
Displays all eight possible active zones. Alarm cells change colors
and name field flashes indicating alarms. Allows user direct access
to screen that shows which channels belong to each zone.

 

Teledyne 8864 Controller - Multichannel Gas And Flame Monitoring System

Product Data Sheet