pesales@pe-energy.com +1 ( 281 ) 310 – 0628

Valve Sealant Selection Guide — How to Choose Valve Sealants, Valve Lubricants & Valve Flush (Val-Tex 80, 972, 750, 2000) | PE Energy

Choosing the right valve sealant or valve lubricant comes down
to three things: the service media (dry gas, liquids, sour gas, CO2), the operating
temperature, and whether you are maintaining a healthy valve or sealing a leaking one in an
emergency. This guide matches each Val-Tex (Valtex) valve lube sealant family to its
intended service so you can specify the correct product the first time.

Browse the full ranges: valve sealants ·
valve lube sealants · valve fittings and adapters ·
all Val-Tex products.

Valve sealant selection table by service

Product Service / application Temperature range Why choose it
Val-Tex 80 Dry gas service (general purpose) -20°F to 500°F The most requested, cost-effective lube sealant for dry gas; amber, biodegradable, free of fillers.
Val-Tex 80-HM Well service units, high-pressure plug valves -20°F to 500°F Very heavy body for extreme pressures; Moly-Disulfide reduces operating torque.
Val-Tex 85 Storage valves at extreme high pressure -20°F to 500°F Extra-heavy lube sealant; amber, biodegradable, free of fillers.
Val-Tex 972 High-pressure / high-temperature plug valves, oil & gas high-temperature service The lube sealant most recommended by high-pressure plug valve manufacturers globally; contains Moly-Disulfide.
Val-Tex 750 Extreme LOW temperature; natural gas, LPG, sour gas, sour crude, CO2 -50°F to 375°F Formulated for extreme cold; also suits hydrocarbons, gasoline and water service.
Val-Tex 700 Liquids: hydrocarbons, LPG, sour gas, sour crude, CO2, gasoline, water liquid service Synthetic sealant with excellent resistance to liquids; contains Moly-Disulfide.
Val-Tex 75 Extreme HIGH temperature; heavy crude systems -20°F to 750°F Highest temperature rating in the line; black; contains Moly-Disulfide.
Val-Tex 80+FTFE EMERGENCY leak sealing, dry gas -20°F to 500°F PTFE particles help seal leaking valves with worn surfaces or soft-seal damage; not for repeated use.
Val-Tex 700+FTFE EMERGENCY leak sealing, hydrocarbon / sour / CO2 liquid service PTFE-filled emergency sealant for leaking valves; not for repeated use.
Val-Tex 2000 New ball valve commissioning (lubricant ONLY) liquid-resistant Pure lubricant, not a sealant; excellent resistance to liquids across gas and liquid service.
Val-Tex PL-1000 API-6A gate valve body fill bulk only Non-petroleum-oil body fill protecting wellheads from corrosion, wear and washout.
Val-Tex Valve Flush Cleaning out hardened sealants before re-lubrication Pressure-and-penetration cleaner; no acid, caustic, solvent or solids.
Sure Seal 1502 Plug valve ASSEMBLY grease Assembly-only grease for maximum sealing and washout resistance during hydrostatic testing.

Which valve sealant should I use for dry gas service?

Val-Tex 80 is the standard choice for dry gas
service: it is the oldest, most requested and most cost-effective lube sealant in the line, rated
-20°F to 500°F, biodegradable and free of fillers. For storage valves at extreme high
pressure step up to Val-Tex 85, and for emergency
sealing of a leaking valve in dry gas use
80+FTFE (PTFE-filled, not for repeated use).

What valve sealant do plug valve manufacturers recommend for high pressure?

Val-Tex 972 is the lube sealant most recommended
by high-pressure plug valve manufacturers globally, formulated for high-pressure and
high-temperature oil and gas service with Moly-Disulfide to reduce operating torque. On well
service units where extreme pressures are encountered, the heavier-bodied
80-HM is the purpose-built alternative.

What is the difference between a valve lubricant and a valve sealant?

A valve lube sealant both lubricates the valve and seals the seat/sealing surfaces,
while a pure valve lubricant only reduces friction and torque.
Val-Tex 2000 is a lubricant ONLY, developed for
commissioning new ball valves, with excellent resistance to liquids across natural gas,
hydrocarbon, LPG, sour and CO2 service. Every other family in the table above is a
combined lube sealant.

How do you clean hardened valve sealant out of a valve?

Val-Tex Valve Flush works on the principle of
pressure and penetration, cleaning out hardened sealants and lubricants left by filler-containing
products. It contains no acid, caustic, solvent or solids, so it cleans the valve without adding
contaminants. Flush first, then re-lubricate with the correct sealant from the table above.

What equipment injects valve sealant sticks and bulk sealant?

Stick and bulk sealants are injected with a lube gun through a grease/sealant fitting. PE Energy
supplies the Val-Tex injection line, from the
Mini Air/Hyd lube gun (5 lb) and
hydraulic gun with hose and gauge to
Quick Stick hydraulic/air and electric/hydraulic guns, plus the
Valve Specialist field kit and a full
range of valve fittings, adapters and body vents.

Request a quote

PE Energy supplies the complete Val-Tex valve maintenance line to oil & gas, pipeline and
industrial operators. Send us your part numbers, sealant family and quantities and
request a quote — our team responds with availability and pricing.