  • 4 FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR T-3B CLASS I, GROUP C & D, DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2.
  • Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain flammable gases, vapors, powdered metals or dust
  • Permanently sealed, liquid to air, finned tube heat exchanger core
  • Ethylene Glycol to water mixture used as a heat transfer fluid in the heater core, providing -45° C. (-49° F) freeze damage protection
  • High-performance electric motor driven fan blows air across finned tubes to effect uniform heat transfer and area heat distribution
  • Manual Reset capillary type limit provides high temperature regulation and is rated for 6,000 cycles of service
  • Stainless steel and aluminum pressure relief valve for overpressure
  • A back-up contactor is included for additional protection
  • 14 gauge steel cabinet powder coated epoxy paint finish contains heater core, motor, and fan assembly
  • Narrow gap safety fan guard shields all moving parts
  • Adjustable louvers allow directional control of air
  • Copper conductor wires enclosed in rigid metal conduits carry all electrical power
  • Box lugs furnished for field connections within approved enclosure
  • Made in U.S.A.
  • California residents see Prop 65 Warnings

Catalog Number

Model Number

BTU

KW

Voltage

Weight (lbs)

07340002

HLA 12-208360-3.0-24

10240

3

208

167

07340102

HLA 12-240160-3.0-24

10240

3

240

167

07340202

HLA 12-240360-3.0-24

10240

3

240

167

07340302

HLA 12-480360-3.0-24

10240

3

480

167

07340502

HLA 12-208360-5.0-24

17100

5

208

167

07340602

HLA 12-240160-5.0-24

17100

5

240

167

07340702

HLA 12-240360-5.0-24

17100

5

240

167

07340802

HLA 12-480360-5.0-24

17100

5

480

167

07341002

HLA 12-208360-7.5-24

25600

7.5

208

167

07341102

HLA 12-240160-7.5-24

25600

7.5

240

167

07341202

HLA 12-240360-7.5-24

25600

7.5

240

167

07341302

HLA 12-480360-7.5-24

25600

7.5

480

167

07341502

HLA 16-208360-10.0-24

34150

10

208

193

07341602

HLA 16-240160-10.0-24

34150

10

240

193

07341702

HLA 16-240360-10.0-24

34150

10

240

193

07341802

HLA 16-480360-10.0-24

34150

10

480

193

07342002

HLA 20-208360-15.0-24

51200

15

208

193

07342102

HLA 20-240360-15.0-24

51200

15

240

193

07342202

HLA 20-480360-15.0-24

51200

15

480

193

07342302

HLA 20-600360-15.0-24

51200

15

600

193

07342402

HLA 20-480360-20.0-24

68300

20

480

225

07342502

HLA 20-600360-20.0-24

68300

20

600

225

07342602

HLA 20-480360-25.0-24

85400

25

480

225

07342702

HLA 20-600360-25.0-24

85400

25

600

225

07343502

HLA 12-208160-3.0-24

10240

3

208

167

07343602

HLA 12-208160-5.0-24

17100

5

208

167

07343702

HLA 12-208160-7.5-24

25600

7.5

208

167

Dimensional Data

TPI HLA Series Hazardous Location Fan Forced Unit Heater dimension data

MFG Model

A

B

C

D

E

F

G

Cell
Cell
Cell

3 PHASE

1 PHASE

Cell
Cell
Cell
Cell

HLA 12

17 3/4

22 3/8

19 3/4

20 5/8

16 1/4

10 1/2

14

3

HLA 16

20 3/4

26 3/8

20 3/4

21 5/8

20 1/4

11 1/2

18

4

HLA 20

24 3/4

30 3/8

22 1/2

Cell

21 1/4

12 1/2

22

4 1/2

*All dimensional data given in inches.